RPI Industries SCAS36R-DI-I Service Manual

RPI Industries, Inc.
AIR SCREEN and SELF-SERVE
OPERATION AND SERVICE MANUAL
WARRANTY INFORMATION
Olympus Drop-In
SCAS36R-DI-I SCAS48R-DI-I SCAS60R-DI-I
SCAS72R-DI-I SCAS36R-DI-II SCAS48R-DI-II SCAS60R-DI-II SCAS72R-DI-II
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
220 Route 70, Medford, NJ 08055
Phone: (609) 714-2330 Fax: (609) 714-2331
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR
FUTURE REFERENCE
RPI Industries, Inc.
Congratulations, you have just purchased the finest air screen/self-serve display case available. RPI Industries, Inc. development of an exclusive humidity and temperature control system insures product shelf life and enticing displays, which leads to a better bottom line. We at RPI Industries, Inc. hope you are satisfied with your case for many years to come.
IMPORTANT IMPORTANT IMPORTANT
Controls are pre-set at our factory. Please consult our refrigeration service department at (609) 714-2330 if setting changes are required.
ADJUSTING CONTROLS WITHOUT PRIOR AUTHORIZATION FROM
RPI INDUSTRIES MAY VOID YOUR WARRANTY
Please consult your operation and service manual for proper care of your case.
For Your Records Enter Model And Serial Number of the Product You Purchased.
Model:____________________________
Serial No.:________________________________
CASES ARE DESIGNED TO OPERATE IN AN ENVIRONMENT OF 75 DEGREES
FAHRENHEIT AMBIENT AND 55% HUMIDITY.
2
RPI Industries, Inc.
REFRIGERATED AIR SCREENS and SELF SERVE CASES
USE & SERVICE MANUAL
1. Temperature of case is controlled by temperature control in storage area. Cases
are pre-set at factory. Settings should not be touched, without first notifying the factory.
2. Condensing unit is COPELAND 115/60 or 208/230V/60 cycle/single phase air-
cooled or equal.
3. Refrigerant: R134A, R22, R404
4. Average case temperature in Air Screens and Self-Serve cases is between 37 and
41 degrees Fahrenheit.
5. Make certain that the drain pan on refrigerated cases is checked weekly. Calcium
deposits may accrue depending on area and water quality. The float on the drain pan should be cleaned weekly for proper operation.
6. Brush out or vacuum condenser (looks like a black radiator) once a month for
efficient operation. (When the condenser is clogged with dirt and dust, the case looses its efficiency, causing the unit to operate without stopping).
7. Do not store packages against blower (evaporator coils) so airflow is not impeded.
8. Do not block airflow inside display area over front and back grill.
9. Keep the flow area around the fixture clean and orderly.
10. Tracks and sliding door fixtures should be cleaned and lubricated periodically.
11. Check inside cooling coil housing to be certain that it is free of ice debris.
12. Replace any malfunctioning parts as soon as possible.
13. It is most important that the interior of the fixture be cleaned periodically. HOW
TO CLEAN: Remove the product load and all shelving. Use only mild soap or detergent to wash the interior panels. Rinse with clean, warm water, and dry with a soft absorbent cloth.
14. Failure to comply with above may void warranty.
3
RPI Industries, Inc.
RECEIVING & INSPECTION PROCEDURE
1. All fixtures have been carefully operation tested and inspected before shipping and
are determined to be in good operating condition before leaving our factory. All units have been run for 24 hours prior to shipment to ensure proper operation.
2. Upon arrival of the fixture the cases should be examined thoroughly for any
damage. If any damage is discovered, it should be noted on the delivery ticket or Bill of Lading and signed to that effect.
3. If you find any hidden damage, notify the carrier at once. Confirm all claims in
writing. RPI Industries, Inc. cannot assume responsibility for filing freight claims, however, the factory will assist if required.
LOCATING THE FIXTURE
1. Locate refrigerator or freezer in a dry, cool and well-ventilated area. When
possible, do not locate any fixture in the direct rays of the sun, near heating ducts, radiators, stoves, doors or any device which will hinder the airflow as designed.
2. There must be at least 24 inches of unobstructed clearance from the condensing
unit compartment.
3. Locate the electrical outlet in such a manner that you may plug in the service cord
(when furnished) direct, without the use of an extension cord, must be 115V/20A or 115/208-230V 20/30-amp circuit (depending upon size of case model). On models not furnished with a service cord, a permanent electrical connection is required. Make sure that no other electrically operated appliances are connected to the circuit operating this fixture, which will cause an overload. Overloaded circuits are extremely hazardous. THE VOLTAGE MUST BE MAINTAINED TO
WITHIN 5% OF VOLTAGE INDICATED ON THE NAMEPLATE FOR PROPER OPERATION.
4. This unit is intended to be sealed to the floor with a NSF approved sealant. Unless
supplied with castors or legs, In addition, Air screen display cases may be installed flush against the rear wall with no clearances.
5. This unit is for use in a max. 75F (24C) room ambient
will effect the operation and warranty of this unit.
.
Higher room temperature
4