Owner’s Manual
Manuel de l’utilisateur
Bedienungsanleitung
Manual de Instrucciones
Manuale di istruzioni
Instruktionsbok
Инструкция пользователя
2
A B
Important Safety Instructions
RA‑1592 Stereo Integrated Amplier
Notice
The RS232 connection should be handled by authorized persons only.
WARNING: There are no user serviceable parts inside. Refer all servicing
to qualified service personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose the
unit to moisture or water. Do not expose the unit to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the unit. Do
not allow foreign objects to get into the enclosure. If the unit is exposed
to moisture, or a foreign object gets into the enclosure, immediately
disconnect the power cord from the wall. Take the unit to a qualified
service person for inspection and necessary repairs.
Read all the instructions before connecting or operating the component.
Keep this manual so you can refer to these safety instructions.
Heed all warnings and safety information in these instructions and on
the product itself. Follow all operating instructions.
Clean the enclosure only with a dry cloth or a vacuum cleaner.
Do not use this unit near water.
You must allow a minimum 10 cm or 4 inches of unobstructed
clearance around the unit.
Do not place the unit on a bed, sofa, rug, or similar surface that could
block the ventilation openings. If the unit is placed in a bookcase or
cabinet, there must be ventilation of the cabinet to allow proper cooling.
Keep the component away from radiators, heat registers, stoves, or any
other appliance that produces heat.
WARNING:
The rear panel power cord connector is the mains power
disconnect device. The device must be located in an open area that
allows access to the cord connector.
The unit must be connected to a power supply only of the type and
voltage specified on the rear panel. (USA: 120 V/60Hz, EC: 230V/50Hz)
Connect the component to the power outlet only with the supplied
power supply cable or an exact equivalent. Do not modify the supplied
cable. A polarized plug has two blades, with one wider than the other. A
grounding plug has two blades plus a third grounding prong. These are
provided for your safety. Do not defeat grounding and/or polarization
safety provisions. If the supplied plug does not fit your outlet, please
consult an electrician for replacement of the obsolete outlet. Do not
use extension cords.
The mains plug is the disconnect of the unit. In order to completely
disconnect the unit from the supply mains, remove the main plug from
the unit and the AC power outlet. This is the only way to completely
remove mains power from the unit.
Do not route the power cord where it will be crushed, pinched, bent,
exposed to heat, or damaged in any way. Pay particular attention to the
power cord at the plug and where the cord exits the back of the unit.
The power cord should be unplugged from the wall outlet during a
lightning storm or if the unit is to be left unused for a long period of time.
Use only accessories specified by the manufacturer.
Use only with a cart, stand, rack, bracket or shelf system strong
enough to support the unit. Use caution when moving the unit in a
stand or rack to avoid injury or damage to the unit.
Use Class 2 wiring for speaker connections to ensure proper installation
and minimize the risk of electrical shock.
Immediately stop using the component and have it inspected and/or
serviced by a qualified service agency if:
• The power supply cord or plug has been damaged.
• Objects have fallen or liquid has been spilled into the unit.
• The unit has been exposed to rain.
• The unit shows signs of improper operation.
• The unit has been dropped or damaged in any way.
The batteries in the remote control should not be exposed to excessive
temperature such as sunshine, fire or other heat sources.
Rotel products are designed to comply with
international directives on the Restriction of
Hazardous Substances (RoHS) in electrical and
electronic equipment and the disposal of Waste
Electrical and Electronic Equipment (WEEE). The
crossed wheelie bin symbol indicates compliance and
that the products must be appropriately recycled
or processed in accordance with these directives.
This symbol means that this unit is double insulated.
An earth connection is not required.
Place the unit on a on a fixed, level surface strong
enough to support its weight. Do not place it on a
moveable cart that could tip over.
Pin Assignments
Balanced Audio (3 pole XLR):
Pin 1: Ground / Screen
2
1
3
Pin 2: In phase / +ve / Hot
Pin 3: Out of phase / ‑ve / Cold
Figure 1: Controls and Connections
3
12
5
AB
76
8
43
9
w
q=-0
e rt
i
o[]
uyp
4
Figure 2: RR‑AX150 Remote Control
RA‑1592 Stereo Integrated Amplier
A
K
L
M
N
SPKR BSPKR A
B
C
D
E
F
MENU
G
H
I
RR-AX150
J
Figure 3: Analog Input and Speaker Output Connections
5
ROTEL RA-1592
GND R L
PH0N
O
ROTEL RCD-1570
SPEAKERSPEAKER
6
Figure 4: Digital Input and 12 Volt Trigger Out Connections
RA‑1592 Stereo Integrated Amplier
Computer
CD PLAYER
DIGITAL AUDIO OUTPUT
COAXIAL
OPTICAL
(Supplied)
ROTEL RA-1592
ROTEL RCD-1570
Figure 5: Balanced (XLR) Inputs
7
ROTEL RA-1592
ROTEL RCD-1570
Figure 6: Front USB Input
AB
iPhone
8
RA‑1592 Stereo Integrated Amplier
Important Notes
When making connections be sure to:
Turn off all the components in the system before hooking up any components, including loudspeakers.
Turn off all components in the system before changing any of the connections to the system.
It is also recommended that you:
Turn the volume control of the amplifi er all the way down before the amplifi er is turned on or off.
Remarques importantes
Pendant les branchements, assurez-vous que :
Tous les maillons sont éteints avant leur branchement, quels qu’ils soient, y compris les enceintes acoustiques.
Éteignez tous les maillons avant de modifi er quoi que ce soit au niveau de leurs branchements, quels qu’ils soient.
Il est également recommandé de :
Toujours baissez le niveau sonore via le contrôle de volume, avant d’allumer ou d’éteindre l’amplifi cateur.
Wichtige Hinweise
Achten Sie beim Herstellen der Verbindungen auf Folgendes:
Schalten Sie alle Komponenten im System ab, bevor Sie Geräte (einschließlich Lautsprecher) anschließen.
Schalten Sie alle Komponenten im System ab, bevor Sie Anschlüsse im System verändern.
Ferner empfehlen wir, dass
Sie die Lautstärke herunterdrehen, bevor Sie die Endstufe ein- oder abschalten.
Notas Importantes
Cuando realice las conexiones, asegúrese de que:
Desactiva todos los componentes del equipo, cajas acústicas incluidas, antes de conectar cualquier nuevo componente en el mismo.
Desactiva todos los componentes del equipo antes de cambiar cualquier conexión del mismo.
También le recomendamos que:
Reduzca el nivel de volumen de su amplifi cador a cero antes de activarlo o desactivarlo.
Héél belangrijk:
Bij het maken van de verbindingen:
Zorg dat niet alleen de RA-1592, maar de gehele installatie uitstaat, als nog niet alle verbindingen gemaakt zijn.
Zorg dat niet alleen de RA-1592, maar de gehele installatie ook uitstaat, als u verbindingen gaat wijzigen.
Wij raden u ook aan om
de volumeregelaar van de voorversterker geheel dicht te draaien (volkomen naar links) wanneer u uw eindversterker aan- of uitzet.
Note importanti
Quando effettuate i collegamenti assicuratevi di:
Spegnere tutti i componenti del sistema prima di collegare qualsiasi componente, inclusi i diffusori.
Spegnere tutti i componenti del sistema prima di modifi care qualsiasi connessione nel sistema.
Vi raccomandiamo inoltre di:
Portare il volume a zero prima di accendere o spegnere l’amplifi catore.
Viktigt
Tänk på följande när du gör anslutningar:
Stäng av alla komponenter i anläggningen innan du ansluter nya komponenter, inklusive högtalare.
Stäng av alla komponenter i anläggningen innan du ändrar någon anslutning i anläggningen.
Vi rekommenderar också att du
Vrider ner volymen på förstärkaren helt och hållet innan förstärkaren stängs av eller sätts på.
Important Safety Instructions ..........................................2
Figure 1: Controls and Connections 3
Figure 2: RR‑AX150 Remote Control 4
Figure 3: Analog Inputs and Speaker Output Connections 5
Figure 4: Digital Input and 12 Volt Trigger out Connections 6
Figure 5: Balanced (XLR) Inputs 7
Figure 6: Front USB Input 7
Important notes 8
About Rotel .......................................................9
A Word About Watts ................................................9
Getting Started ...................................................10
A Few Precautions 10
Placement 10
Cables 10
The RR-AX150 Remote Control ........................................10
Second Amplier Remote Code 10
Remote Control Batteries 10
AC Power and Control ..............................................11
AC Power Input [ 11
POWER Switch and Power Indicator 1 11
12V TRIGGER Connection r 11
Input Signal Connections
Phono Input u and Ground Connection (GND) 11
Line Level Inputs u 11
Balanced (XLR) Inputs p 11
Digital Signal Inputs - 11
Our story began over 50 years ago. Over the decades, we have received
hundreds of awards for our products and satised hundreds of thousands
of people who take their entertainment seriously - like you!
Rotel was founded by a family whose passionate interest in music led them
to manufacture high-delity components of uncompromising quality. Through
the years, that passion has remained undiminished and the family goal of
providing exceptional value for audiophiles and music lovers, regardless
of their budget, is shared by all Rotel employees.
Rotel’s engineers work as a close team, listening to, and ne tuning, each
new product until it reaches their exacting musical standards. They are
free to choose components from around the world in order to make that
product the best they can. You are likely to nd capacitors from the United
Kingdom and Germany, semiconductors from Japan or the United States,
while toroidal power transformers are manufactured in Rotel’s own factory.
We all have concerns about our environment. And, as more and more
electronics are produced it is especially important for a manufacturer to do all
it can to engineer products that have a minimum impact on the environment.
At Rotel, we are proud to do our part. We have reduced the lead content
in our products by using special lead-free ROHS solder and components.
Our engineers continually strive to improve power supply efciency without
compromise to quality. When in standby mode Rotel products use minimal
power to meet global Standby Power Consumption requirements.
The Rotel factory is also doing their part to help the environment through
constant improvements to product assembly methods for a cleaner and
greener manufacturing processes.
All of us at Rotel thank you for buying this product. We are sure it will bring
you many years of enjoyment.
A Word About Watts
This amplier’s power output is rated as 200 watts for each channel, when
both channels are operating together at full power. Rotel has chosen to
specify the power output in this way because, in Rotel’s experience, it gives
the truest value of the receiver or amplier’s power capability.
When comparing specications for different products, you should be
aware that power output is often specied in other ways, so you may not
be comparing like with like. For example, the power output may be quoted
with only one channel operating, giving a higher maximum gure.
A loudspeaker’s impedance rating indicates the electrical resistance or
load it offers when connected to the amplier, usually 8 ohms or 4 ohms.
The lower the impedance, the more power the speaker will need. In effect,
a 4 ohm speaker will require twice as much power as an 8 ohm speaker.
However, Rotel ampliers are designed to work into any speaker impedance
between 8 and 4 ohms, and with all the channels working up to their full
power. Because Rotel designs are optimized for use with all channels operating
together, Rotel is able to specify the true power output for both channels.
10
RA‑1592 Stereo Integrated Amplier
Getting Started
Thank you for purchasing the Rotel RA-1592 Stereo Integrated Amplier.
When used in a high-quality music audio system, your Rotel product will
provide years of musical enjoyment.
The RA-1592 is a full featured, high performance component. All aspects
of the design have been optimized to retain the full dynamic range and
subtle nuances of your music. The RA-1592 has a highly regulated power
supply incorporating a Rotel custom-designed toroidal power transformer
and custom-made slit foil capacitors. This low impedance power supply has
ample power reserves, which enables the RA-1592 to easily reproduce the
most demanding audio signals. This type of design is more expensive to
manufacture, but it is better for the music.
The printed circuit boards (PCB) are designed with Symmetrical Circuit Traces.
This insures that the precise timing of the music is maintained and faithfully
recreated. The RA-1592 circuitry uses metal lm resistors and polystyrene
or polypropylene capacitors in important signal paths. All aspects of this
design have been examined to ensure the most faithful music reproduction.
The main functions of the RA-1592 are easy to install and use. If you have
experience with other stereo systems, you shouldn’t nd anything perplexing.
Simply plug in the associated components and enjoy.
A Few Precautions
WARNING: To avoid potential damage to your system, turn off ALL
the components in the system when connecting or disconnecting the
loudspeakers or any associated components. Do not turn the system
components back on until you are sure all the connections are correct
and secure. Pay particular attention to the speaker wires. There must
be no loose strands that could contact the other speaker wires, or the
chassis of the amplifier.
Please read this manual carefully. In addition to basic installation and
operating instructions, it provides valuable information on various RA-1592
system congurations as well as general information that will help you get
optimum performance from your system. Please contact your authorized
Rotel dealer for answers to any questions you might have. In addition, all
of us at Rotel welcome your questions and comments.
10 cm (4 inches) of clearance around the chassis, and reasonable airow
through the installation location, to prevent the amplier from overheating.
Remember the weight of the amplier when you select an installation location.
Make sure that the shelf or cabinet can support it. We recommend installing
the RA-1592 in furniture designed to house audio components. Such furniture
is designed to reduce or suppress vibration which can adversely affect
sound quality. Ask your authorized Rotel dealer for advice about component
furniture and proper installation of audio components.
The RA-1592 is supplied with an RR-AX150 remote control and must be
placed where the infrared signal from the remote can reach the front panel
Remote Sensor.
Cables
Be sure to keep the power cords, digital signal cables and regular audio
signal cables in your installation away from each other. This will minimize
the chance of the regular audio signal cables picking up noise or interference
from the power cords or digital cables. Using only high quality, shielded
cables will also help to prevent noise or interference from degrading the
sound quality of your system. If you have any questions see your authorized
Rotel dealer for advice about the best cable to use with your system.
The RR‑AX150 Remote Control
Some functions can be done with either the front panel controls, or the
supplied RR-AX150 remote control. When these operations are described,
the square call out numbers refer to the main unit, while the encircled letters
refer to the remote control.
Second Amplier Remote Code
The factory setting is remote code 1. If you nd that the remote is conicting
with other Rotel ampliers, you can change to remote code 2 with the
following steps.
1. From the remote control press Tuner J and 2 L at the same time to set
the remote control to send Audio Code 2.
2. Point the remote at the unit and press 2 L button for 8 seconds. The unit
will show “Audio Custom Code 1 -> 2”.
Save the shipping carton and all enclosed packing material for future use.
Shipping or moving the RA-1592 in anything other than the original packing
material may result in severe damage to your amplier.
If included in the box please ll out and send in the owner’s registration
card. Also be sure to keep the original sales receipt. It is your best record
of the date of purchase, which you will need in the event warranty service
is ever required.
Placement
Like all audio components that handle low-level signals, the RA-1592 can
be affected by its environment. Avoid placing the RA-1592 on top of other
components. Also avoid routing audio signal cables near power cords. This
will minimize the chance it will pick up hum or interference.
The RA-1592 generates heat as part of its normal operation. The heat sinks
and ventilation openings in the amplier are designed to dissipate this
heat. The ventilation slots in the top cover must be open. There should be
3. Repeat the above procedure and press “1” button instead of “2” to change
the unit back to Code 1.
NOTE: The remote control can be used to operate the basic functions of
Rotel tuners and CD players. Remote control buttons labeled HILN
can be used to operate CD or Tuner functions in your system. For the
remote to operate properly, make sure both the remote and the CD or
Tuner are both in same remote code, either Code 1 or 2.
Remote Control Batteries
Two AA size batteries (supplied) must be installed before the remote control
can be used. To install the batteries, remove the cover on the back of the
RR-AX150. Install the batteries as shown in the illustration in the battery
well. Test the control for proper operation, then replace the cover. When
the batteries become weak the remote control won’t operate the RA-1592
consistently. Installing fresh batteries should eliminate the problem.
11
AC Power and Control
AC Power Input [
Your RA-1592 is congured at the factory for the proper AC line voltage in
the country where you purchased it (either 120 volts AC or 230 volts AC
with a line frequency of either 50 Hz or 60 Hz). The AC line conguration
is noted on a decal on the back panel.
NOTE: Should you move your RA‑1592 to another country, it is possible
to reconfigure your amplifier for use on a different line voltage. Do not
attempt to perform this conversion yourself. Opening the enclosure of
the RA‑1592 exposes you to dangerous voltages. Consult a qualified
service person or the Rotel factory service department for information.
NOTE: Some products are intended for sale in more than one country
and as such are supplied with more than one AC cord. Please only use
the one appropriate for your country/region.
Because of its relatively high power rating, the RA-1592 can draw considerable
current. Therefore, it should be plugged directly into a 2-pin polarized wall
outlet. Do not use an extension cord. A heavy duty multi-tap power outlet
strip may be used if it (and the wall outlet) is rated to handle the current
demanded by the RA-1592 and all the other components connected to it.
If you are going to be away from home for an extended period of time
such as a month-long vacation, it is a sensible precaution to unplug your
amplier (as well as other audio and video components) while you are away.
POWER Switch and Power Indicator 1
Press the front panel Power Switch button, to turn the unit on. The Power
Indicator light is illuminated when the unit is on. Press Power Switch button
again to turn the unit off.
Phono Input u and Ground Connection (GND)
See Figure 3
Plug the cable from the turntable into the appropriate left and right phono
inputs. If the turntable has a “ground” wire, connect it to the screw terminal
to the left of the Phono inputs. It will help prevent hum and noise.
Line Level Inputs u
See Figure 3
The CD, Tuner, and Aux inputs of the amplier are analog “line level” inputs.
These inputs are for connecting components such as CD players or other
audio playback devices with an analog audio output.
The left and right channels are clearly labeled and should be connected to
the corresponding channels of the source component. The Left connectors
are white, the Right connectors are red. Use high quality RCA cables for
connecting input source components to the RA-1592. Ask your authorized
Rotel dealer for advice about cables.
Balanced (XLR) Inputs p
See Figure 5
A pair of balanced XLR inputs accept audio signals from CD player, Blu-ray
player or other source components with XLR outputs.
NOTE: You should choose only one method of analog connection from
a source component to RA‑1592. Do not connect both the RCA and
XLR outputs of a source component to the RA‑1592 at the same time.
When the power switch is in the ON position, the remote control ON and
OFF buttons may be used to activate the RA-1592. In Standby mode the
power LED remains lit, but the display is turned off.
NOTE: Place the self adhesive ring over the light surrounding the Power
switch if the blue light is too bright.
12V TRIGGER Connection r
Some audio components can be turned on automatically when they receive a
12V turn on “signal”. The two 12V Trigger Outputs of the RA-1592 provide
the required signal. Connect compatible components to the RA-1592 with
a conventional 3.5mm mini plug cable. When the RA-1592 is in turn off
mode, the trigger signal is interrupted, so the components controlled by it
are turned off.
NOTE: If you are using other units in the series with Rotel link, please
use the Rotel Link connection to turn the units on or off. Do not connect
both the Rotel Link and 12V trigger cables. The 12V trigger’s power
on or off features will override the Rotel Link features.
Input Signal Connections
See Figure 3,4,5
NOTE: To prevent loud noises that neither you nor your speakers will
appreciate, make sure the system is turned off when you make any
signal connections.
-up
Digital Signal Inputs -
See Figure 4
There are three sets of digital inputs labeled 1, 2 and 3, for COAXIAL and
OPTICAL respectively. Connect the COAXIAL or OPTICAL PCM outputs of
your source component into these sockets. The digital signals will be decoded
and played by the RA-1592. The unit is capable of decoding PCM signals
up to 24 bit, 192kHz.
Output Connections
MONO SUB Output i
There are 2 connectors for mono subwoofer output to connect to a subwoofer.
These mono outputs are summed with both the left and right audio signal. They
are parallel outputs allowing 2 subwoofers to be connected to the RA-1592.
Preamp Outputs o
The RA-1592 has a set of preamp outputs labeled PRE OUT. The signal
from the source selected with the Function Selector is always available from
these outputs. Typically the PRE OUT output is used to provide a signal to
another integrated amplier or power amplier, which is used to drive
remote speakers.
NOTE: Changes to the settings of the Volume, Balance or Tone controls
affect the signal from the Preamp Outputs.
12
RA‑1592 Stereo Integrated Amplier
Speaker Outputs
See Figure 3
The RA-1592 has two sets of speaker outputs, labeled SPEAKER A and
SPEAKER B. The speaker outputs are controlled by the switch 7on the
front panel and the buttons Kon the remote control.
]
Speaker Selection
If only one set of speakers will be used at any given time, the speakers may
have an impedance as low as 4 ohms. If there are times when both the A
and B speakers will be used, all the speakers should have an impedance
of 8 ohms or more. Speaker impedance ratings are less than precise. In
practice, very few loudspeakers will present any problems for the RA-1592.
See your authorized Rotel dealer if you have any questions.
Speaker Wire Selection
Use insulated two-conductor stranded wire to connect the RA-1592 to the
speakers. The size and quality of the wire can have an audible effect on the
performance of the system. Standard speaker wire will work, but can result in
lower output or diminished bass response, particularly over longer distances.
In general, heavier wire will improve the sound. For best performance, you
may want to consider special high-quality speaker cables. Your authorized
Rotel dealer can help in the selection of cables for your system.
Polarity and Phasing
The polarity – the positive/negative orientation of the connections – for every
speaker and amplier connection must be consistent so all the speakers will
be in phase. If the polarity of one connection is reversed, bass output will
be very weak and stereo imaging degraded. All wire is marked so you can
identify the two conductors. There may be ribs or a stripe on the insulation
of one conductor. The wire may have clear insulation with different color
conductors (copper and silver). There may be polarity indications printed
on the insulation. Identify the positive and negative conductors and be
consistent with every speaker and amplier connection.
Speaker Connections ]
Turn off all the components in the system before connecting the speakers.
The RA-1592 has color-coded binding post type speaker connectors on the
back panel. These connectors accept bare wire, connector lugs, or dual
banana type connectors. (except in European Community countries where
their use is not permitted.)
Route the wire from the RA-1592 to the speakers. Give yourself enough slack
so you can move the components to allow access to the speaker connectors.
If you are using dual banana plugs, connect them to the wires and then
plug into the backs of the binding posts. The thumbscrews of the binding
posts should be screwed in all the way (clockwise).
If you are using terminal lugs, connect them to the wires. If you are attaching
bare wires directly to the binding posts, separate the wire conductors and
strip the insulation from the end of each conductor. Be careful not to cut into
the wire strands. Unscrew (turn counterclockwise) the binding post. Place
the connector lug or wire around the binding post shaft. Turn the binding
post clockwise to clamp the connector lug or wire rmly in place.
NOTE: Be sure there are no loose wire strands that could touch adjacent
wires or connectors.
Headphone Output 5
The headphone output allows you to connect headphones for private listening.
This output accepts a standard 3.5mm (1/8”) mini stereo headphone
connector. Plugging in a set of headphones does not cut off the signal to
the speakers. Use the Speaker Selector to turn off the speakers. The settings
of the Function Selector determines which source is heard.
NOTE: Because the sensitivity of speakers and headphones can
vary widely, always reduce the volume level before connecting or
disconnecting headphones.
Remote Sensor
This remote sensor window receives IR commands from the remote control.
Please do not block this sensor.
Display
The front panel display shows the source selected, volume level and tone
settings.
3
Front USB Input
See Figure 6
The front USB input can be connected to an iPod or iPhone. With iPod or
iPhone, simply plug the device into the front USB and select USB function
from the source selector. The iPod and iPhone remain active allowing search
and play functions.
APTX Bluetooth Connection
The Bluetooth Antenna 0 on the RA-1592’s back panel is for wireless
streaming via Bluetooth, from your device (i.e. mobile phones). From your
mobile device, look for “Rotel Bluetooth” and connect to it. Connection is
normally automatic, but if prompted for a password, please press “0000”
on your device. The RA-1592’s supports both traditional Bluetooth and APTX
Bluetooth audio streaming.
2
6
0
Audio Controls
VOLUME Control 4D
Turn the knob clockwise to increase the volume, or counter clockwise to
decrease the volume. From the remote control press the volume + or - button
to turn the volume up or down. Press the MUTE E button to completely
mute the volume.
BALANCE Control 9C
The Balance Control adjusts the left-to-right balance of the sound output. The
factory default is the center position or “0”. To change the balance from
the front panel, press the MENU 9button to toggle the front display to
BALANCE SETTING mode. Then press the - or + buttons on the front panel to
change the value to LEFT or RIGHT. The value can change from L15 to R15.
13
NOTE: This setting is saved permanently including after powering off
the RA‑1592.
To make temporary changes not saved after power off, from the remote,
press the BAL C button to access the BALANCE SETTING menu, then press
the up/down/left/right G arrow buttons to adjust. When nished, press
the BAL C button again to exit the menu.
Tone Control Bypass 9C
Bass and Treble Control (Tone Control) circuits are bypassed at factory
default to ensure the purest possible sound. The front display will show TONE
BYPASS. To turn on the tone control from the front panel, press the MENU
button to toggle to the Bypass control then press the - or + buttons on
9
the front panel to turn bypass on or off.
NOTE: This setting is saved permanently including after powering off
the RA‑1592.
To temporarily changes the Tone Control Bypass, press the BYPASS C button
on the remote control to toggle the Bypass mode enabled and disabled.
Bass and Treble Controls 9C
Set the Bass or Treble controls from the front panel by pressing the MENU
9 button to toggle to either the BASS or TREBLE Setting menu. Then press
the - or + button to adjust the value. The Bass and Treble values range from
-10 to +10.
NOTE: These settings are saved permanently including after powering
off the RA‑1592.
To temporarily change the Bass and Treble settings from the remote control,
press the BASS or TREB button C, then press the up/down/left/right G
arrow buttons on the remote to adjust the value.
NOTE: When Tone Bypass is disabled, Bass and Treble settings can
not be changed by the BASS/TREB buttons C.
A properly setup high-performance audio system produces the most natural
sound with little or no adjustment of the tone controls. Use these controls
sparingly. Be particularly careful when turning the controls up as this
increases the power output in the bass or treble range, increasing the load
on the amplier and speakers.
NOTE: Setting the Bass and Treble controls does not automatically turn
on the tone control. To turn on tone control, refer to previous section
Tone Control Bypass.
NOTE: Tone Bypass, Bass, Treble and Balance are only saved
permanently from within the Menu. Adjustments made using the C
buttons are temporary only and not saved after power off.
Dimmer Control
Display Dimmer 9B
To change the brightness of the front display, press the MENU 9 button
to toggle to the Display Settings. Then press the - or + buttons on the front
panel to change the brightness.
NOTE: This setting is saved permanently including after powering off
the RA‑1592.
To temporarily change the display brightness, press the DIM B button on
the remote.
NOTE: Display Dimmer setting is only saved permanently from within
the Menu. Adjustment made using the B button is temporary only and
not saved after power off.
PC‑USB Input q
Connect this input using the supplied USB cable to the USB socket of your
computer.
The RA-1592 supports both USB Audio Class 1.0 and USB Audio Class
2.0 modes. Windows computers do not require installation of a driver for
USB Audio Class 1.0 and support playback of audio up to 96kHz sampling
rates. The Factory Default setting is USB Audio Class 1.0.
To take advantage of USB Audio Class 2.0 audio playback supporting
up to 192kHz sampling rates you will need to install the Windows driver
supplied on the CD included with the RA-1592. You will also need to switch
the RA-1592 to USB Audio Class 2.0 playback mode with the following:
• Press MENU on the front panel until “PC-USB AUDIO CLASS” appears
on the display.
• Select “2.0” using the “-” button then press “ENTER”.
• Power cycle the RA-1592 and reboot your PC after changing the USB
Audio mode to ensure both units are properly congured.
Many audio playback applications do not support 192kHz sampling rate.
Please conrm your audio player supports 192kHz audio and you have
192kHz audio les to properly playback this sample rate. Also, you may
need to congure the audio driver in your PC to output 192kHz or your
computer may “down sample” to a lower audio sample rate. For more
information please refer to your audio player or operating system information.
NOTE: USB Audio Class 2.0 requires installation of the Windows PC
driver on the CD ROM included with the RA‑1592.
Function Control 8J
The Function control selects the input signal source. From the front panel or
remote press the corresponding input button to select the source to listen to.
NOTE: MAC computers do not require a driver to support PC‑USB
1.0 or 2.0 audio.
NOTE: Upon successful installation of the driver, you may need to select
the ROTEL audio driver from the audio/speaker setup of your computer.
NOTE: The RA‑1592 supports both DSD and DOP audio playback
in 1X and 2X formats. Consult your audio player to confirm proper
operation for playback of these audio formats.
14
RA‑1592 Stereo Integrated Amplier
RS232 t
The RA-1592 can be controlled via RS232 for integration with automation
systems. The RS232 input accepts a standard straight DB-9 Male-to-Female
cable.
For additional information on the connections, software, and operating codes
for computer control of the RA-1592, contact your authorized Rotel dealer.
ROTEL LINK w
The ROTEL LINK OUT connection can be made with the stereo 3.5 mm
cable (supplied) to a Rotel integrated amplier and CD player. While the
ROTEL LINK IN can optionally attach to Rotel network enabled products
with ROTEL LINK OUT connections.
These allow the attached Rotel products to communicate with each other
and be controlled via the Rotel Remote App (available for download on
the iTunes® store).
NOTE: Only the Rotel Link cables supplied with this product should be
used. These 3.5 mm cables have WHITE connector ends and should
not be confused with the 12 Volt Trigger cables that have BLACK
connector ends.
Most likely, you will never see this protection circuitry in action. However,
should a faulty condition arise, the amplier will stop playing and will
display “AMP PROTECTION“ on the front panel.
If this happens, turn the amplier off. Let it cool down for several minutes,
and attempt to identify and correct the problem that caused the protection
circuitry to engage. When you turn the amplier back on, the protection
circuit will automatically reset.
In most cases, the protection circuitry activates because of a fault condition
such as shorted speaker wires, or inadequate ventilation leading to an
overheating condition. In very rare cases, highly reactive or extremely low
impedance speaker loads could cause the protection circuit to engage.
If the protection circuitry triggers repeatedly and you are unable to isolate
and correct the faulty condition, contact your authorized Rotel dealer for
assistance in troubleshooting.
Settings Menu
You can access the settings menu from the front panel by pressing the MENU
button or F on the remote. You can change the value of the selected
9
option by pressing the +/- button on the front panel or up/down/left/right
G arrow buttons on the remote. Step through the sub-menus by pressing
the MENU 9 button on the front panel or F on the remote.
EXT REM IN Jack e
This 3.5mm mini-jack receives command codes from industry-standard infrared
receivers via hard-wired connections. This feature could prove useful when
the unit is installed in a cabinet and the front-panel sensor is blocked. Consult
your authorized Rotel dealer for information on these external repeaters and
the proper wiring of a jack to t the mini-jack receptacle.
Network Connection =
The RA-1592 can be attached to a network using the rear panel NETWORK
socket =. The NETWORK congurations allow both STATIC and DHCP
IP addressing. See the Network section of this manual under Setting Menu
for IP address conguration information.
The NETWORK connections allows software updates to be downloaded from
the Internet. The Network connection also allows IP control for integration
with automation systems.
For additional information on the IP connection please contact your
authorized Rotel dealer.
Protection Circuit
The amplier has both thermal and over-current protection circuitry that
protects the amplier against damage in the event of extreme or faulty
operating conditions. The protection circuits are independent of the audio
signal and have no impact on sonic performance. Instead, the protection
circuits monitor the temperature of the output devices and shut down the
amplier if temperatures exceed safe limits.
• TONE Control: TONE BYPASS ON/OFF, BASS level and TREBLE levels
can be changed to desired settings. Press the ENTER button on the front
panel or on the remote to toggle between the tone setup options. (For
more information on Tone Control refer to the Tone Control Bypass, Bass
and Treble control sections.)
NOTE: These settings are stored permanently even after the RA‑1592
is powered off.
• BALANCE: Change left/right balance (For more information on Balance
sections refer to the Balance Control section).
NOTE: This setting is stored permanently even after the RA‑1592 is
powered off.
• DIMMER: Dims the display.
NOTE: This setting is stored permanently even after the RA‑1592 is
powered off.
• ROTEL LINK RCD: Selects how the CD player is connected to the amplier,
either CD (analog), COAX1, COAX2, or BAL-XLR. CD is the factory default.
• POWER ON MAX VOLUME: This sets the maximum volume level when
the unit is turned ON. “45” is the factory default.
NOTE: Power On Max Volume settings do not apply to sources
configured with Fixed Gain.
• POWER OPTION: Enables the RA-1592 to be controlled via the network
port when attached to an automation system. The power consumption is
higher in Quick Power mode. If network control is not required select the
Normal Power mode. “Normal” is the factory default.
15
• AUTO POWER OFF: The RA-1592 can be congured to automatically
power off if unused for a specied period. If no changes are made to the
unit within the specied “Auto Power Off” time the unit will automatically
go to STANDBY mode. The Auto Power Off timer will be restarted if
changes are made to the volume, source or playback. The default for
Auto Power Off is set to DISABLE.
• FIXED GAIN: Congures a Fixed Volume level for a specied input. To
enable this feature press the +/- buttons to select the desired xed volume
level for Aux 1, USB, PC-USB, Optical 1, Optical 2, Coax 1, Coax 2 or
Bluetooth. When enabled and the input with a Fixed Volume is selected,
the Volume level will immediately be set to the specied level.
• AUX1 VOL: VARIABLE (disabled) is factory default.
• USB VOL: VARIABLE (disabled) is factory default.
• PC-USB VOL: VARIABLE (disabled) is factory default.
• OPT1 VOL: VARIABLE (disabled) is factory default.
• OPT2 VOL: VARIABLE (disabled) is factory default.
• COAX1 VOL: VARIABLE (disabled) is factory default.
If STATIC IP address mode is selected you must congure all settings for the
network including IP Address, Subnet Mask, Gateway and DNS Server. Use
the up/down/left/right or +/- buttons to adjust the values and press ENTER
to move to the next value. When the proper IP information is congured
press MENU to go to the next setting. After entering the STATIC IP address
information the network will be tested and connection status reported.
NOTE: For more information regarding network connection please
contact your authorized Rotel dealer.
NOTE: A network connection is not required for the RA‑1592 to
operate.
• MAIN: This shows the current software version loaded into the RA-1592.
The software can be updated if the RA-1592 is properly connected to
the Internet.
• Press ENTER to check if a new software version is available.
• If a new software version is available press the + button on the front
panel or the up/right button on the remote control to select YES then
press ENTER button to begin the software update process.
• The new software will be downloaded from the Internet. The RA-1592
will power cycle when the software update is complete.
NOTE: Do NOT power off the RA‑1592 during the software update
process.
• COAX2 VOL: VARIABLE (disabled) is factory default.
• BLUETOOTH VOL: VARIABLE (disabled) is factory default.
NOTE: The Volume knob on the front panel and Volume +/‑ buttons on
the IR remote are disabled when the volume is Fixed. To disable this
feature set the Fixed Volume level to “Variable”.
• PC-USB AUDIO CLASS: Change supported PC-USB Audio Class of the
attached device.
NOTE: Some computers attached to the PC‑USB do not support USB
Audio Class 2.0 and do not support 24/192 audio playback. If needed
the PC‑USB can be configured for USB Audio Class 1.0. Please refer
to your computer operating system for details.
• NETWORK: Shows the network connection status and to view/congure
the network settings. If the network is properly congured and attached,
“Connected” will be displayed. To view or modify the network settings,
press the ENTER button.
The RA-1592 supports both DHCP and STATIC IP addressing. Select the
desired IP address method and press ENTER.
If DHCP is selected you can refresh IP address by pressing ENTER or press
MENU to view IP address information. Press the MENU button to toggle
through IP address settings. If the IP address is renewed the network will
be tested and connection status reported.
NOTE: It is recommended to Reset Factory Defaults after the software
update is complete.
• PC-USB: This shows current loaded software version for PC-USB processor.
• SIGNAL SENSE: Check if a digital audio signal is present on the congured
Signal Sense input. When this input is selected as the active listening
source the RA-1592 monitors the digital data stream to determine if
there is audio. If there is no audio detected for 10 minutes, the RA-1592
will enter Signal Sense Standby Mode. When in Signal Sense Standby
Mode and the RA-1592 detects audio on Signal Sense input, the unit
will automatically power on. To disable this function, select the DISABLE
option which is the factory default setting.
NOTE: To use the Signal Sense function the RA‑1592 must be actively
listening to the configured Signal Sense source. If a source other than
the configured Signal Sense source is selected, the automatic power
off and power on functions will not be active. Example if the Signal
Sense source is configured as COAX 1 and the unit is listening to OPT
2, the signal sense functions will not be activated.
NOTE: When the RA‑1592 enters standby mode via the remote
control, the Signal Sense function will not function until the unit detects
the audio has stopped for the minimum 10 minute time‑out period. This
prevents the unit from immediately powering back on if there is still
active audio playing. For example if listening to a streaming player on
OPT 1 and this is configured as the Signal Sense source, when the IR
remote powers off the unit the music must first stop before the Automatic
Power on function would be possible to prevent a conflict with the IR
control and Signal Sense function.
16
RA‑1592 Stereo Integrated Amplier
• FACTORY DEFAULT: This sets the unit back to the original state as when
it left the factory. Press the + button on the front panel or RIGHT arrow
button on the remote control to select <YES> then press the “ENTER”
button on the front panel or on the remote control.
NOTE: All previously configured options will be erased and reset to
the factory default settings.
Troubleshooting
Most difculties in audio systems are the result of incorrect connections,
or improper control settings. If you encounter problems, isolate the area
of the difculty, check the control settings, determine the cause of the fault
and make the necessary changes. If you are unable to get sound from the
RA-1592, refer to the suggestions for the following conditions:
Power Indicator Is Not Illuminated
The Power Indicator ring around the power button and the basic items in the
Display window should be illuminated whenever the RA-1592 is plugged
into the wall power outlet and the POWER switch is pushed in. If it does not
light, test the power outlet with another electrical device, such as a lamp.
Be sure the power outlet being used is not controlled by a switch that has
been turned off.
Fuse Replacement
If another electrical device works when plugged into the power outlet, but
the Power Indicator still will not light when the RA-1592 is plugged into
the wall outlet, it indicates that the internal power fuse may have blown.
If you believe this has happened, contact your authorized Rotel dealer to
get the fuse replaced.
Playable Audio Formats
USB Apple (iPhone, iPod, iPad)
FormatNotes
Any supported le
loaded to Apple
device.
APTX Bluetooth
FormatNotes
Any format supported
by the sending device.
PC-USB
FormatNotes
Format determined
by the Media Player/
Server software that
you use.
Coax/Optical
FormatNotes
SPDIF LPCM
Any supported le loaded to Apple device. Phone
may resample depending on stored format. May
exclude Apps designed to play formats not originally
supported by the sending device.
May exclude Apps designed to play formats not originally
supported by the sending device.
Any supported format by the PC software
PCM Audio: 44.1k, 48k, 88.2k, 96k, 176.4k, 192k
(16 bit and 24 bit)
DSD64 and DSD128
44.1k, 48k, 88.2k, 96k, 176.4k, 192k
16 bit, 24 bit
No Sound
Check the signal source to see if it is functioning properly. Make sure the
cables from the signal source to the RA-1592 inputs are connected properly.
Check the wiring between the RA-1592 and the speakers.
Cannot Connect via Bluetooth
If you cannot pair your Bluetooth enabled device to the RA-1592, delete the
memory of the previous connection on the RA-1592 and on your device. On
your device this is often listed as “Forget this Device”. On the RA-1592 IR
remote PRESS and HOLD the STOP I button for 5 seconds until the front
display shown “Reset BT DB List?” then release the button. Select <Yes> and
press “ENTER”. Then try to make the connection again.
17
Specications
Continuous Power Output 200 watts/channel
(20 ‑ 20k Hz, < 0.03%, 8 ohms)
Total Harmonic Distortion < 0.03%
(20 Hz ‑ 20k Hz, 8 ohms)
Intermodulation Distortion < 0.03%
(60 Hz : 7kHz, 4:1)
Frequency Response:
Phono Input 20 Hz - 20kHz, 0 ± 0.5 dB
Line Level Inputs 10 Hz - 100kHz, 0 ± 0.5 dB
Damping Factor (20 Hz ‑ 20kHz, 8 ohms) 600
Input Sensitivity / Impedance
Phono Input (MM)5.2 mV / 47k ohms
Line Level Inputs (RCA)340 mV / 100k ohms
Line Level Inputs (XLR)540 mV / 100k ohms
Input Overload
Phono Input (MM)52 mV
Line Level Inputs (RCA)3.5 V
Line Level Inputs (XLR)5.5 V
Preamplifier Output Level / Impedance 1.9 V / 100 ohms
Signal to Noise Ratio (A weighted)
Phono Input (MM)80 dB
Line Level Inputs 103 dB
Digital Section
Frequency Response 10 Hz - 90k Hz (0 ± 2dB, Max)
Signal to Noise Ratio (IHF ”A” weighted) 102 dB
Input Sensitivity/Impedance 0 dBfs / 75 ohms
Preamplifier Output Level 1.4 V (at -20 dB Volume Position)
Coaxial/Optical Digital Signals SPDIF LPCM
(up to 192k Hz 24 bit)
PC-USB USB Audio Class 1.0
(up to 96kHz 24bit)
USB Audio Class 2.0
(up to 384kHz 32bit)*
*Driver installation required
DSD and DoP support.
Power Requirements:
USA: 120 volts, 60 Hz
EC: 230 volts, 50 Hz
Power Consumption 500 watts
Standby Power Consumption < 0.5 watts
BTU (4 ohms, 1/8th power)1239 BTU/h
Dimensions (W x H x D)431 x 144 x 425 mm
( 17 x 5 7/8 x 16 ins.)
Front Panel Height 3U (132.6 mm, 5 1/4 ins)
Weight (net) 16.8 kg, 37.04 lbs.
“Made for iPod,” and “Made for iPhone,” means that an electronic accessory
has been designed to connect specically to iPod or iPhone, respectively, and
has been certied by the developer to meet Apple performance standards.
Apple is not responsible for the operation of this device or its compliance with
safety and regulatory standards. Please note that the use of this accessory
with iPod, or iPhone may affect wireless performance.
iPhone, iPod, iPod classic, iPod nano, and iPod touch are trademarks of
Apple Inc., registered in the U.S. and other countries.
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Rotel and the Rotel Hi-Fi logo are registered trademarks of The Rotel Co, Ltd., Tokyo,
Japan.
18
ATTENTION
RISQUE D’ÉLECTROCUTION.
NE PAS OUVRIR
ATTENTION : RISQUE D’ÉLECTROCUTION.
NE PAS OUVRIR
L’éclair dans un triangle équilatéral indique
la présence interne de tensions électriques
élevées susceptibles de présenter des
risques graves d’électrocution.
Le point d’exclamation dans un triangle
équilatéral indique à l’utilisateur la
présence de conseils et d’informations
importantes dans le manuel d’utilisation
accompagnant l’appareil. Leur lecture est
impérative.
A B
Remarques importantes concernant la sécurité
RA‑1592 Amplicateur Stéréo Intégré
Remarque
Le branchement repéré RS232 ne concerne que des techniciens agréés
uniquement.
ATTENTION : Il n’y a à l’intérieur aucune pièce susceptible d’être modifiée
par l’utilisateur. Adressez-vous impérativement à une personne qualifiée.
ATTENTION : Pour réduire tout risque d’électrisation ou d’incendie, ne
pas exposer l’appareil à une source humide, ou à tout type de risque
d’éclaboussure ou de renversement de liquide. Ne pas poser dessus
d’objet contenant un liquide, comme un verre, un vase, etc. Prenez
garde à ce qu’aucun objet ou liquide ne tombe à l’intérieur de l’appareil
par ses orifices de ventilation. Si l’appareil est exposé à l’humidité ou
si un objet tombe à l’intérieur, débranchez-le immédiatement de son
alimentation secteur, et adressez-vous immédiatement et uniquement
à une personne qualifiée et agréée.
Tous les conseils de sécurité et d’installation doivent être lus avant de
faire fonctionner l’appareil.
Conservez soigneusement ce livret pour le consulter à nouveau pour
de futures références.
Tous les conseils de sécurité doivent être soigneusement respectés.
Suivez les instructions. Respectez les procédures d’installation et de
fonctionnement indiquées dans ce manuel.
L’appareil doit être nettoyé uniquement avec un chiffon sec ou un
aspirateur.
Ne pas utiliser cet appareil près d’un point d’eau.
Vous devez réserver un espace libre d’une dizaine de
centimètres minimum autour de l’appareil.
Il ne doit pas être posé sur un fauteuil, un canapé, une couverture ou
toute autre surface susceptible de boucher ses ouïes d’aération ; ou
placé dans un meuble empêchant la bonne circulation d’air autour des
orifices d’aération.
Cet appareil doit être placé loin de toute source de chaleur, tels que
radiateurs, chaudières, bouches de chaleur ou d’autres appareils
produisant de la chaleur.
ATTENTION : La prise d’alimentation située à l’arrière constitue le
principal moyen pour déconnecter l’appareil du secteur. Cet équipement
doit être positionné dans un espace ouvert qui permet de garder l‘accès
au câble d’alimentation.
Cet appareil doit être branché sur une prise d’alimentation secteur, d’une
tension et d’un type conformes à ceux qui sont indiqués sur la face arrière
de l’appareil (USA : 120 V/60 Hz, CE : 230 V/50 Hz).
Brancher l’appareil uniquement grâce au cordon secteur fourni, ou à
un modèle équivalent. Ne pas tenter de modifier ou changer la prise.
Notamment, ne pas tenter de supprimer la prise de terre (troisième
broche de la prise) si celle-ci est présente. Si la prise n’est pas conforme
à celles utilisées dans votre installation électrique, consultez un électricien
agréé. Ne pas utiliser de cordon rallonge.
La prise d’alimentation secteur constitue le moyen radical de déconnexion
de l’appareil. Elle doit donc rester en permanence accessible, car sa
déconnexion constitue la seule assurance que l’appareil n’est plus
alimenté par le secteur.
Prendre garde à ce que ce cordon d’alimentation ne soit pas pincé,
écrasé ou détérioré sur tout son trajet, et à ce qu’il ne soit pas mis en
contact avec une source de chaleur. Vérifiez soigneusement la bonne
qualité des contacts, à l’arrière de l’appareil comme dans la prise murale.
Débranchez le câble d’alimentation en cas d’orage, ou si l’appareil ne
doit pas être utilisé pendant une longue période.
N’utilisez que des accessoires préconisés par le constructeur.
N’utilisez que des meubles, supports, systèmes de transport suffisamment
solide pour supporter l’appareil. Procédez toujours avec la plus extrême
précaution lorsque vous déplacez l’appareil, afin d’éviter tout risque de
blessure ou des dommages à l’appareil.
Utilisez uniquement des câbles de Classe 2 pour réalise les connexions aux
enceintes acoustiques et offrant une isolation suffisante pour minimiser
les risques de chocs électriques.
L’appareil doit être immédiatement éteint, débranché puis retourné au
service après-vente agréé dans les cas suivants :
• Le câble d’alimentation secteur ou sa prise est endommagé.
• Un objet est tombé, ou du liquide a coulé à l’intérieur de l’appareil.
• L’appareil a été exposé à la pluie.
• L’appareil ne fonctionne manifestement pas normalement.
• L’appareil est tombé, ou le coffret est endommagé.
Les piles de la télécommande infra-rouge ne doivent en aucun cas
exposées à une chaleur excessive notamment au feu ou au soleil direct.
Tous les appareils Rotel sont conçus en totale
conformité avec les directives internationales
concernant les restrictions d’utilisation de substances
dangereuses (RoHS) pour l’environnement, dans
les équipements électriques et électroniques, ainsi
que pour le recyclage des matériaux utilisés (WEEE,
pour Waste Electrical and Electronic Equipment). Le
symbole du conteneur à ordures barré par une croix
indique la compatibilité avec ces directives, et le fait
que les appareils peuvent être correctement recyclés
ou traités dans le respect total de ces normes.
Ce symbole signifie que cet appareil bénéficie d’une
double isolation électrique. Le branchement d’une
mise à la masse ou à la terre n’est pas nécessaire.
Mettez en place l’appareil sur un support fixe et
suffisamment solide pour pouvoir supporter son
poids. Ne le posez pas sur un chariot mobile duquel
il risquerait de tomber.
Assignation des connecteurs
Audio Symétrique (prise XLR 3 broches) :
1
3
Pin 2 : Phase/+ve /Point chaud
Pin 1 : Masse/Terre
2
Pin 3 : Hors Phase /-ve / Point froid
Français
19
Sommaire
Figure 1 : Commandes et Branchements 3
Figure 2 : Télécommande infrarouge RR-AX150 4
Figure 3 : Branchements des entrées analogiques et sorties enceintes acoustiques 5
Figure 4 : Entrées numériques et Branchements des sorties trigger 12 V 6
Figure 5 : Entrées symétriques (XLR) 7
Figure 6 : Entrée USB en face avant 7
Remarques importantes 8
Remarques importantes concernant la sécurité ............................18
A propos de Rotel .................................................19
Un mot à propos des « Watts » ........................................19
Mise en route ....................................................20
Quelques précautions préalables 20
Installation 20
Câbles 20
Contrôle de volume 4D 23
Balance 9C 23
Activation/désactivation du contrôle de tonalité 9C23
Ajustements Graves/Aigus 9C23
Commutateur de fonction 8J 24
Contrôle de luminosité de l’affichage ....................................24
Luminosité de l’écran 9B 24
Entrée pour PC-USB q .............................................24
RS232 t .......................................................24
ROTEL LINK w ...................................................24
Prise jack pour télécommande externe e ................................25
L’indicateur de mise sous tension n’est pas allumé 27
Remplacement du fusible 27
Pas de son 27
Pas de connexion Bluetooth 27
Formats de lecture compatibles 27
Notre histoire commence il y a environ 50 ans. Depuis, au l des années,
nous avons reçu des centaines de prix et de récompenses, et satisfait des
centaines de milliers de personnes – comme vous !
Rotel a été fondée par une famille passionnée de musique, qui a décidé
de fabriquer des maillons Haute Fidélité sans compromis aucun. Depuis sa
création, cette passion est restée intacte, et cette famille s’est xée comme
objectif de proposer à tous les audiophiles et mélomanes les meilleurs
appareils possibles, quel que soit leur budget. Une volonté partagée par
tous les employés de Rotel.
Les ingénieurs Rotel travaillent comme une équipe très soudée, écoutant,
peaunant chaque nouveau modèle jusqu’à ce qu’il atteigne exactement
leurs standards – très élevés – de musicalité. Ils sont libres de choisir des
composants en provenance du monde entier, an de concevoir le meilleur
produit possible. C’est ainsi que vous trouverez dans nos appareils des
condensateurs d’origine britannique ou allemande, des transistors japonais
ou américains, tandis que les transformateurs toriques sont toujours fabriqués
dans nos propres usines Rotel.
Nous sommes tous concernés par la qualité de l’environnement. Et, comme de
plus en plus de produits électroniques sont fabriqués puis éliminés quelques
années plus tard, il est désormais essentiel qu’un constructeur fabrique tous
ses produits en veillant à ce qu’ils aient un impact minimum sur la planète.
Chez Rotel, nous sommes très ers d’apporter notre pierre à ce nouvel édice.
Nous avons réduit la teneur en plomb de nos électroniques, en utilisant
notamment des composants et une soudure spéciale ROHS. Nos ingénieurs
travaillent en permanence pour améliorer le rendement des alimentations de
puissance sans compromettre leur qualité. C’est ainsi qu’en mode Standby,
les appareils Rotel consomment moins pour se conformer aux exigences
de la « Standby Power Consumption » qui limite la consommation en veille
des appareils électroniques.
L’usine Rotel participe également de façon active à la protection de
l’environnement au travers d’un processus de fabrication général amélioré
et toujours plus écologique et plus propre.
Tous les membres de l’équipe Rotel vous remercient pour l’achat de cet
appareil. Nous sommes persuadés qu’il vous offrira de nombreuses années
d’intense plaisir musical.
Un mot à propos des « Watts »
La puissance de sortie de cet amplicateur a été mesurée à 200 Watts pour
chacun canal, les deux canaux fonctionnant ensemble et à niveau nominal.
Rotel a choisi de spécier la puissance de sortie de cette façon parce que,
selon l’expérience Rotel, elle correspond à la vraie valeur des possibilités
de puissance de l’ampli-tuner ou de l’amplicateur.
Lorsque vous comparez les caractéristiques de différents produits, vous devez
avoir conscience du fait que les valeurs de puissance sont souvent spéciées
de façon différente, ce qui signie que vous ne pouvez pas vraiment les
comparer les unes avec les autres. Par exemple, la valeur de puissance
maximale peut être donnée avec un seul canal en service, ce qui donne
forcément un chiffre plus élevé.
20
RA‑1592 Amplicateur Stéréo Intégré
La valeur d’impédance d’une enceinte acoustique correspond à la
résistance électrique – ou la charge – qu’elle présente quand elle est reliée
à l’amplicateur. Le plus souvent c’est 8 ohms ou 4 ohms. Plus l’impédance
est basse, et plus l’enceinte aura besoin de puissance. Par exemple, une
enceinte d’impédance 4 ohms nécessitera deux fois plus de puissance
qu’une enceinte de 8 ohms.
Cependant, les amplicateurs Rotel sont conçus pour fonctionner avec
n’importe quelle enceinte acoustique disposant d’une impédance comprise
entre 4 et 8 ohms et avec tous les canaux en service et à puissance nominale.
La conception des produits Rotel étant optimisée pour un usage avec tous
les canaux fonctionnant ensemble, Rotel peut ainsi spécier une vraie valeur
de puissance pour chacun des canaux.
Mise en route
Merci d’avoir acheté cet Amplicateur Stéréo Intégré Rotel RA-1592.
Associé à un ensemble audio de qualité, il vous offrira de nombreuses
années de plaisir musical.
Le RA-1592 est un appareil haute performance, doté de fonctionnalités
avancées. Tous les aspects de sa conception ont été optimisés pour garantir
une dynamique sans faille et restituer les nuances les plus subtiles de votre
musique. Le RA-1592 dispose d’une alimentation hautement régulée intégrant
un transformateur de puissance toroïdal spéciquement conçu par Rotel. Cette
alimentation basse impédance dispose de réserves d’énergie importantes
et permet au RA-1592 de prendre facilement en charge tous les types de
signaux audio, même les plus exigeants. Ce type de composant est certes
plus cher à fabriquer, mais il est d’une qualité supérieure sur le plan musical.
Les cartes électroniques (PCB) sont conçues sur le principe de circuits
symétriques (Symmetrical Circuit Traces), pour garantir une synchronisation
parfaite du signal musical, et donc une restitution optimale. Les circuits
utilisent des résistances à ls métalliques et des condensateurs polystyrènes
ou polypropylènes sur les circuits les plus critiques. Tous les aspects de la
conception de l’appareil ont été rigoureusement étudiés pour garantir une
reproduction musicale la plus dèle possible.
vous pourriez vous poser. En outre, nous sommes toujours heureux, chez
Rotel, de recevoir vos toutes vos remarques et commentaires.
Conservez soigneusement le carton du RA-1592 ainsi que tous les éléments
servant à l’emballage pour un usage futur éventuel. En effet, expédier ou
déménager l’amplicateur dans quoique ce soit d’autre que son carton
d’origine peut avoir pour conséquence d’endommager gravement votre
RA-1592.
Remplissez et renvoyez la carte d’enregistrement du propriétaire qui est jointe
à votre produit, et conservez en lieu sûr la facture originale. Elle constitue
votre meilleure preuve de date d’achat au cas où vous auriez besoin de
faire appliquer la garantie constructeur.
Installation
Comme tous les appareils audio faisant transiter des signaux de faible
intensité, le RA-1592 pourra être affecté par son environnement. Évitez de
disposer l’amplicateur sur d’autres éléments du système. Éviter également
de faire passer les câbles transportant le signal audio à proximité des
cordons secteur. Cela réduira au minimum les problèmes potentiels de
parasites ou de bruit de fond.
Le RA-1592 génère de la chaleur pendant son fonctionnement normal.
Les ouïes de refroidissement et la ventilation interne de l’amplicateur
sont conçues pour dissiper la chaleur. Les ouïes de refroidissement sur le
dessus de l’appareil doivent rester libres. Il doit y avoir environ 10 cm de
dégagement tout autour de lui pour permettre le bon fonctionnement de
sa ventilation et une bonne circulation d’air tout autour du meuble qui le
supporte pour éviter toute surchauffe à l’amplicateur.
Prenez en compte le poids et les dimensions de l’appareil lorsque vous le
disposez sur une étagère, un meuble ou dans un rack, et vériez que ceux
ci sont bien en mesure de supporter son poids. Nous vous conseillons de
disposer le RA-1592 dans un meuble conçu pour intégrer des éléments
audio domestiques. De tels meubles sont spécialement fabriqués pour réduire
ou supprimer les vibrations qui peuvent affecter la qualité sonore. Prenez
conseil auprès de votre revendeur agréé Rotel sur un choix du meuble et
pour une installation correcte de vos éléments audio.
Toutes les fonctions principales du RA-1592 sont faciles à congurer et à
utiliser. Si vous avez déjà l’expérience d’autres systèmes stéréo, vous ne
devriez pas rencontrer de difcultés particulières. Connectez simplement
les composants associés, et protez de votre musique.
Quelques précautions préalables
AVERTISSEMENT : Pour éviter d’endommager potentiellement votre
système, veillez à bien mettre hors tension TOUS les éléments lorsque
vous branchez ou vous débranchez les enceintes acoustiques et les
composants associés. Ne mettez pas les appareils en marche tant vous
n’êtes pas certain que tous les branchements sont corrects et sécurisés.
Prêtez une attention particulière aux câbles des enceintes acoustiques.
Il ne doit y avoir aucun fil qui puisse entrer en contact avec les autres
câbles d’enceintes ou avec le châssis de l’amplificateur.
Merci de lire soigneusement ce manuel. Il vous donne des renseignements
utiles sur la meilleure façon d’intégrer votre RA-1592 au sein de votre
système ainsi que des informations qui vous aideront à en obtenir les
meilleures performances sur le plan sonore. N’hésitez pas à contacter votre
revendeur agréé Rotel pour obtenir les réponses à toutes les questions que
Le RA-1592 est fourni avec une télécommande infrarouge RR-AX150 et
devra être installé de façon à ce que le signal infrarouge puisse atteindre
la diode réceptrice située en face avant.
Câbles
Les cordons secteur, les câbles numériques et les câbles de modulation
transportant le signal audio devront être si possible éloignés les uns des
autres. Cela pour réduire au minimum le risque que le signal audio puisse
être affecté par des interférences ou parasites provenant des câbles secteur
ou numériques. Utilisez uniquement des câbles de haute qualité. Les câbles
blindés sont particulièrement indiqués pour réduire le bruit de fond et les
parasites qui viendraient dégrader la qualité sonore de votre système. Pour
toutes ces questions, consultez votre revendeur agréé Rotel, qui pourra vous
conseiller sur le choix du meilleur câble à utiliser avec votre système audio.
Télécommande infrarouge RR-AX150
Les commandes peuvent être effectuées depuis les boutons de la face avant,
ou via la télécommande RR-AX150 fournie avec votre appareil. Dans ce
manuel, les lettres et nombres entourés d’un carré se réfèrent aux commandes
Français
21
exécutables au niveau de la face avant de l’appareil et, respectivement,
celles qui sont entourés d’un rond par la télécommande infrarouge.
Code secondaire de télécommande
Le code de télécommande usine par défaut est le code 1. Si vous constatez
que la télécommande est en conit avec d’autres amplicateurs Rotel,
vous pouvez changer le code et mettre en place le code 2 en suivant les
instructions ci-dessous :
1. Sur la télécommande appuyez sur « Tuner » J et sur « 2 » L en même
temps pour que la télécommande puisse envoyer le Code Audio 2.
2. Pointer la télécommande vers l’appareil et appuyez sur 2 L pendant
8 secondes. L’appareil va alors afcher « Audio Custom Code 1 -> 2 »
3. Recommencez la procédure et appuyez sur « 1 » au lieu de « 2 » pour
remettre l’appareil sur le Code 1.
REMARQUE : vous pouvez utiliser votre télécommande pour le
pilotage des fonctions de base de tuners et lecteurs de CD Rotel. Les
touches libellées HILN pourront notamment être utilisées pour
piloter les fonctions du lecteur CD ou tuner Rotel de votre système.
Pour un fonctionnement correct de votre système, assurez-vous que la
télécommande, le lecteur de CD et le Tuner, utilisent bien tous le même
code de télécommande.
Piles de la télécommande
Deux piles de type AA (fournies) doivent être insérées dans la télécommande
au préalable à son utilisation. Pour mettre en place les piles, enlevez le
couvercle situé à l’arrière de la RR-AX150. Insérez les piles comme indiqué
sur la Figure. Faites un test de fonctionnement, puis remettez le couvercle
en place. Lorsque les piles deviennent faibles, la télécommande ne pourra
plus piloter correctement le RA-1592. Installez alors des piles neuves pour
éliminer le problème.
Alimentation secteur et commandes
Prise secteur [
Votre RA-1592 est conguré en usine pour fonctionner avec la tension
d’alimentation secteur en vigueur dans le pays où vous l’avez acheté (ÉtatsUnis : 120 volts/60 Hz ou Communauté Européenne : 230 volts/50 Hz).
La conguration est inscrite sur une étiquette à l’arrière de votre RA-1592.
et la prise murale seront capables de supporter la totalité de la puissance
requise par l’amplicateur et celle des autres éléments connectés.
Si vous prévoyez de vous absenter pendant une période de temps assez
longue, c’est une bonne précaution de débrancher votre amplicateur (ainsi
que les autres éléments audio) pendant votre absence.
Interrupteur de mise sous tension/veille Standby et indicateur
Power1
Appuyez sur le bouton Power Switch sur la face avant pour mettre l’appareil
en marche. La diode indicatrice de mise sous tension va s’allumer, indiquant
que l’amplicateur est désormais sous tension. Appuyez de nouveau sur le
bouton pour repasser votre appareil sur arrêt.
Lorsque le bouton de mise sous tension Power Switch est sur la position
ON, les touches ON et OFF de la télécommande peuvent être utilisés pour
activer le RA-1592. En mode Standby, la diode de mise sous tension reste
allumée, mais l’afcheur reste éteint.
REMARQUE : Mettez en place l’anneau adhésif autour de l’indicateur
lumineux de mise sous tension, si vous trouvez la lumière bleue trop
intense.
Branchement trigger 12 V r
Un certain nombre d’appareils audio peuvent être mis sous tension
automatiquement quand ils reçoivent un signal 12V appelé « signal trigger».
Les deux sorties trigger 12 V du RA-1592 sont à même de délivrer ce signal.
Connectez des appareils compatibles au RA-1592 à l’aide d’un câble
standard de type mini-jack 3.5 mâle. Dès lors que le RA-1592 est mis hors
tension, le signal trigger est coupé, par conséquent les appareils connectés
sont automatiquement mis hors tension.
REMARQUE : Si vous utilisez d’autres éléments de la gamme équipés
de la liaison Rotel-Link, utilisez dans ce cas la liaison Rotel-Link pour
mettre vos appareils sous tension ou hors tension. N’utilisez pas
simultanément la liaison Rotel-Link et les câbles trigger 12V : en effet,
les liaisons marche/arrêt trigger 12 V sont prioritaires par rapport aux
connexions Rotel-Link.
Connexions d’entrée du signal
Voir Figures 3, 4, et 5
-up
REMARQUE : Au cas où vous seriez amené à déménager votre
appareil dans un pays étranger, il sera possible de changer sa tension
d’alimentation en interne. N’essayez pas de faire cette opération
vous-même. En effet, ouvrir le châssis expose à des tensions élevées et
potentiellement dangereuses. Adressez vous un technicien qualifié, ou
au service après-vente Rotel pour plus d’informations.
REMARQUE : Certains produits sont destinés à être commercialisés
dans plusieurs pays et sont par conséquent fournis avec plusieurs
cordons secteur. Choisissez bien le câble secteur qui correspond à
votre pays de résidence.
Du fait de sa puissance de sortie relativement élevée, votre RA-1592 peut
nécessiter des niveaux en courant très importants. Par conséquent, dans
la mesure du possible, il sera préférable de le brancher directement à une
prise murale. N’utilisez pas de rallonge. Vous pouvez toutefois utiliser un
bloc multiprises de qualité, mais en étant sûr qu’à la fois le bloc multiprises
REMARQUE : Pour éviter de forts bruits parasites que vous ou vos
enceintes pourraient de ne pas apprécier, assurez-vous que les éléments
de votre système sont sur arrêt avant de faire les connexions.
Entrée Phono u et connexion à la masse [GND]
Voir Figure 3
Branchez le câble issu de votre platine tourne-disque dans les prises phono
appropriées gauche et droite. Si votre platine tourne-disque dispose d’un
l de « masse », connectez-le à la borne à vis située à gauche des entrées
Phono. Cela permet d’éviter des ronements et parasites éventuels.
22
RA‑1592 Amplicateur Stéréo Intégré
Entrées Lignes u
Voir Figure 3
Les prises CD, Tuner et Aux de l’amplicateur sont des entrées dites « Lignes
». Elles permettent de connecter des éléments comme les lecteurs CD ou
d’autres éléments audio équipés de sorties analogiques.
Les canaux Gauches et Droits sont explicitement libellés et doivent être branchés
aux canaux correspondant des éléments sources. Les canaux Gauches sont
blancs, et les canaux Droits sont rouges. Utilisez des câbles de modulation
de qualité pour relier les éléments sources au RA-1592. Demandez conseil
auprès de votre revendeur Rotel pour le choix de ces câbles.
Entrées symétriques (XLR) p
Voir Figure 5
Une paire d’entrées symétriques sur prises XLR permettra de recevoir les
signaux audio issus d’un lecteur de CD, d’un lecteur Blu-ray, ou d’autres
éléments également équipés de sorties XLR.
REMARQUE : Vous devrez choisir entre l’un ou l’autre type de sorties
analogiques pour relier un appareil source au RA-1592. Ne branchez
pas simultanément les sorties RCA et XLR d’un élément source à votre
amplificateur.
Entrées Numériques -
Sorties pour enceintes acoustiques ]
Voir Figure 3
Le RA-1592 dispose de deux jeux de sorties pour enceintes acoustiques,
libellées « SPEAKER A » et « SPEAKER B ». Ces sorties sont sélectionnables
au moyen d’un commutateur 7, situé sur la face avant, ou de la touche
K de la télécommande.
Choix des enceintes acoustiques
Si une seule paire d’enceintes acoustiques est utilisée, celles-ci doivent avoir
une impédance minimale de 4 Ohms. Si, occasionnellement, deux jeux
d’enceintes A et B sont utilisées de façon simultanée, toutes les enceintes
doivent alors avoir une impédance de 8 Ohms ou plus. En pratique, très
peu d’enceintes acoustiques peuvent présenter un problème de compatibilité
avec le RA-1592. Consultez votre revendeur agréé Rotel pour toute question
sur ce point.
Choix des câbles d’enceintes acoustiques
Utilisez du câble isolé à deux conducteurs pour relier le RA-1592 aux
enceintes acoustiques. Le diamètre et la qualité du câble utilisé peut avoir
un effet audible sur les performances du système. Du câble standard pour
enceintes fonctionnera, mais il pourra en résulter un niveau de sortie plus
faible et une réponse dans le grave diminuée. D’une façon générale, un
plus gros câble donnera de meilleurs résultats sur le plan sonore. Pour
des performances optimales, vous pouvez envisager l’utilisation de câble
d’enceintes de très haute qualité. Votre revendeur agréé Rotel pourra vous
conseiller sur un choix de câbles optimal pour votre système.
Voir Figure 4
Il existe trois jeux d’entrées numériques libellées 1, 2, et 3 pour COAXIAL
et OPTICAL respectivement. Branchez les sorties coaxiales ou optiques PCM
de votre source aux prises correspondantes. Les signaux numériques seront
alors décodés, convertis, et ampliés par votre RA-1592. Votre RA-1592
est capable de prendre en charge et de décoder les signaux PCM jusqu’à
24 bits et 192 kHz.
Connexion des sorties
Sortie MONO SUB i
2 connecteurs pour caisson de graves mono permettent de faire la liaison
vers un caisson de graves. Ces deux sorties mono sont chacune la somme
de la voie gauche et de la voie droite du signal audio. Elles fonctionnent
en parallèle, ce qui permet de relier simultanément deux caissons de graves
au RA-1592.
Sorties Préampli o
Le RA-1592 dispose d’un jeu de sorties préampli libellées PRE OUT. Le
signal issu d’une des sources choisie par le sélecteur de fonction (Function
Selector) sera toujours disponible au niveau de ces sorties. Concrètement,
la sortie PRE OUT sera utilisée pour restituer le signal audio à un autre
amplicateur intégré ou à un amplicateur de puissance, qui sera alors
utilisé pour alimenter des enceintes acoustiques distantes.
REMARQUE : Les changements effectués au niveau des réglages de
volume, de balance ou de contrôle de tonalité affectent le signal de
la sortie préampli.
Polarité et Phase
La polarité – autrement dit, le branchement positif ou négatif des câbles – pour
chacune des connexions aussi bien pour les enceintes que l’amplicateur,
devra être en parfaite cohérence de manière à ce que toutes les enceintes
soient rigoureusement en phase. Si la polarité d’un des branchements est
inversée, le niveau de graves sera faible et l’image stéréo sera dégradée. Les
câbles d’enceintes sont marqués de façon à ce que vous puissiez clairement
identier les deux conducteurs. Le câble peut notamment être transparent
et les conducteurs être de couleurs différentes (cuivre et argent). Il peut
aussi y avoir des indications imprimées directement sur l’isolant. Identiez
soigneusement les conducteurs et connectez les en parfaite cohérence entre
chacune des enceintes, et chaque amplicateur.
Branchement des enceintes ]
Mettez sur arrêt tous les éléments du système avant de brancher les enceintes.
Le RA-1592 dispose de bornes de connexion à vis pour enceintes acoustiques
avec code couleur sur le panneau arrière. Ces connecteurs acceptent du câble
nu, des cosses à fourche, ou des ches de type bananes (excepté dans les
pays de la Communauté européenne, où leur utilisation n’est pas permise).
Déployez les câbles depuis le RA-1592 jusqu’aux enceintes. Donnez-leur
sufsamment de mou pour pouvoir déplacer facilement les éléments, de
manière à accéder sans difculté aux connecteurs d’enceintes.
Si vous utilisez des prises bananes doubles, connectez-les aux câbles et
branchez-les au centre des bornes à vis. Les bornes de connexion devront
être vissées à fond dans tous les cas (dans le sens des aiguilles d’une montre).
Si vous utilisez des cosses à fourches, reliez-les d’abord aux câbles. Enn,
si vous faites le choix de relier directement les câbles nus aux bornes à
vis, séparez les deux conducteurs et dénudez-en chaque extrémité. Faites
attention à ne pas couper les ls constituant le câble. Dévissez (tournez
Français
23
dans le sens contraire des aiguilles d’une montre) les bornes de connexion.
Placez la cosse à fourche ou le câble nu autour de la vis. Vissez à fond
l’extrémité des bornes de connexion dans le sens des aiguilles d’une montre
pour bien sécuriser le branchement de la cosse à fourche ou du câble nu.
REMARQUE : Assurez-vous qu’il n’y ait aucun fil qui puisse toucher
le câble adjacent ou le châssis du RA-1592.
Sortie Casque 5
La sortie casque vous permet de brancher des écouteurs pour proter de
votre système sans déranger votre entourage. Cette sortie est compatible
avec un connecteur casque standard (jack stéréo 3.5 mm- 1/8’’). Le fait
de connecter un casque ne coupe pas le signal de sortie : utilisez si besoin
le commutateur Speaker Selector si vous voulez couper le son destiné aux
enceintes. La position des commutateurs Function Selector détermine quelle
est la source qui est écoutée.
REMARQUE : Dans la mesure où la sensibilité des enceintes et des
casques peuvent varier dans de larges proportions, prenez la précaution
de diminuer le niveau du volume avant de brancher ou de débrancher
votre casque.
Récepteur de la télécommande 2
Commandes Audio
Contrôle de volume 4D
Tournez le bouton de volume dans le sens des aiguilles d’une montre pour
augmenter le volume, ou tournez le bouton dans le sens inverse pour diminuer
le volume. Sur la télécommande appuyez sur les touches volume + ou – pour
augmenter ou diminuer le volume. Appuyez sur la touche MUTE E pour
couper le son temporairement.
Balance 9C
Le réglage de balance permet d’ajuster l’équilibre sonore entre les canaux
gauche et droit. La position usine par défaut de ce réglage est la position
neutre « 0 » (centrale). Pour modier le réglage de balance depuis le panneau
avant, appuyez sur la touche MENU 9 pour passer l’écran d’afchage dans
le mode BALANCE SETTING. Puis, appuyez sur les touches LEFT (gauche)
ou RIGHT (droite) de la face avant pour modier l’équilibre sonore vers la
gauche ou vers la droite. La valeur peut aller de L15 à R15.
REMARQUE : Ce ajustement est conservé de manière permanente,
même quand vous mettez le RA-1592 hors tension.
Pour faire des ajustements temporaires, qui ne seront pas sauvegardés
quand vous mettrez l’appareil hors tension, appuyez sur la touche BAL C
pour accéder au menu BALANCE SETTING, puis appuyez sur les touches
LEFT ou RIGHT G pour effectuer les réglages. Lorsque vous avez terminé,
appuyez sur la touche BAL C pour sortir du menu.
La diode qui reçoit les signaux infrarouge émis par la télécommande se
situe à ce niveau. Ne pas masquer son emplacement.
Afcheur 3
L’écran d’afchage du panneau avant indique le nom de la source en cours,
le niveau du volume et les réglages courant de tonalité.
Entrée USB en face avant 6
Voir Figure 6
L’entrée USB de la face avant permet de connecter un iPod ou un iPhone.
Si vous utilisez un iPod ou un iPhone, il vous suft de le brancher à l’entrée
USB et de sélectionner « USB » au niveau du commutateur de sources. L’iPod
ou l’iPhone reste actif, vous permettant notamment d’effectuer la recherche
d’un morceau et d’en effectuer la lecture.
Connexion Bluetooth APTX
L’antenne Bluetooth 0 située à l’arrière de votre RA-1592 est destinée à
la connexion sans l par Bluetooth depuis un appareil portable Bluetooth,
par exemple un téléphone mobile. Au niveau de votre appareil portable,
recherchez le périphérique « Rotel Bluetooth » et connectez-vous. La connexion
est normalement automatique, toutefois, s’il vous était demandé de saisir un
mot de passe, entrez « 0000 » au niveau de votre appareil. Le RA-1592
est compatible à la fois avec les ux audio diffusés en Bluetooth traditionnel
et les ux audio Bluetooth APTX.
0
Activation/désactivation du contrôle de tonalité 9C
Les réglages de graves et d’aigus (contrôle de tonalité) sont inhibés par
défaut pour garantir un son le plus pur possible. Par conséquent, l’écran
de la face avant afche TONE BYPASS. Pour activer le réglage de tonalité,
depuis la face avant, appuyez sur la touche MENU 9 pour accéder au
menu BYPASS du réglage de tonalité, puis appuyez sur les touches LEFT et
RIGHT pour changer le mode BYPASS en on ou off.
REMARQUE : Ce ajustement est conservé de manière permanente,
même quand vous mettez le RA-1592 hors tension.
Pour réaliser un réglage temporaire du contrôle de tonalité, appuyez sur
la touche BYPASS C de la télécommande pour passer successivement en
mode activé/désactivé du contrôle de tonalité.
Ajustements Graves/Aigus 9C
Réglez le niveau de graves ou d’aigus depuis le panneau avant, en appuyant
sur la touche MENU 9 pour pouvoir entrer dans le menu d’ajustement
des graves et des aigus. Puis, utilisez les touches « + » et « – » pour faire
les réglages. Les valeurs de graves et d’aigus peuvent prendre les valeurs
-10 à +10.
REMARQUE : Ces ajustements sont conservés de manière permanente,
même quand vous mettez le RA-1592 hors tension.
Pour effectuer des ajustements temporaires des réglages de graves ou
d’aigus à partir de la télécommande, appuyez sur la touche BASS ou TREB
C, puis sur les boutons haut/bas/gauche/droite G sur la télécommande
pour ajuster le réglage à la valeur désiré.
REMARQUE : Quand le réglage TONE BYPASS est désactivé, les
réglages de graves et d’aigus ne peuvent pas être ajustés par les
touches Graves/Aigus C.
24
RA‑1592 Amplicateur Stéréo Intégré
Un système audio de bonne qualité et convenablement mis en œuvre délivrera
d’emblée un son pur et naturel qui ne nécessitera pas – ou très peu – de
réglages de tonalité. Utilisez par conséquent ces ajustements avec modération.
Soyez particulièrement prudent quand vous les augmentez. Cela à pour effet
de renforcer la demande de puissance dans le grave et dans l’aigu, et donc
la charge au niveau de l’amplicateur et des enceintes acoustiques.
REMARQUE : L’ajustement des graves et des aigus n’active pas
automatiquement le contrôle de tonalité. Pour activer le contrôle
de tonalité, reportez-vous au paragraphe précédent « Activation/
désactivation du contrôle de tonalité ».
REMARQUE : Les réglages TONE BYPASS, BASS, TREBLE et BALANCE
ne peuvent être sauvegardés de façon permanente que via le Menu.
Les ajustement réalisés avec les boutons C sont temporaires et ne sont
pas conservés quand l’appareil est mis hors tension.
Commutateur de fonction 8J
Le commutateur de fonction (Function Control) permet de choisir la source
effective de signal. Depuis le panneau avant ou avec la télécommande,
appuyez sur la touche correspondante pour choisir la source que vous
voulez écouter.
Contrôle de luminosité de l’afchage
Luminosité de l’écran 9B
Pour modier la luminosité de l’écran de face avant, appuyez sur le bouton
MENU 9 pour accéder au réglage de luminosité (Display Settings). Puis,
appuyez sur les touches « + » et « – » pour changer la luminosité.
REMARQUE : Ce ajustement est conservé de manière permanente,
même quand vous mettez le RA-1592 hors tension.
Pour effectuer des changements temporaires de luminosité de l’écran
d’afchage, appuyez sur la touche DIM B de la télécommande.
• Appuyez sur la touche MENU du panneau avant, jusqu’à ce le message
« PC-USB AUDIO CLASS » s’afche sur l’écran.
• Sélectionnez « 2.0 » en utilisant la touche « – » et appuyez sur la touche
« ENTER »
• Faites faire un Marche/Arrêt, à la fois au RA-1592 et à votre PC après
avoir changé le mode USB Audio, pour être sûr que les deux appareils
soient correctement congurés.
Beaucoup d’applications de lecture audio ne sont pas compatibles avec la
fréquence d’échantillonnage à 192 kHz. Assurez-vous d’utiliser un lecteur
audio qui prenne en charge le format 192 kHz, et que vous utilisez bien des
chiers échantillonnés à la fréquence de 192 kHz. En outre, vous devrez
congurer le programme qui gère les sorties audio de votre PC (également
appelé « driver audio ») pour qu’il délivre la fréquence de 192kHz.
Sinon, la fréquence de sortie risque d’être réduite (« down sampling »)
à une fréquence d’échantillonnage inférieure. Pour plus d’informations,
reportez-vous au paramétrage de votre lecteur audio, ou à celui de votre
système d’exploitation.
REMARQUE : Les ordinateurs de type PC fonctionnant sous Windows
requièrent l’installation du « driver » contenu sur le CD-ROM fourni avec
le RA-1592 pour exploiter le mode USB Audio Class 2.0.
REMARQUE : Les ordinateurs de type MAC ne nécessitent pas de «
driver » pour être compatible avec le mode USB Audio Class 2.0 ou 1.0.
REMARQUE : Après avoir installé le programme sur votre ordinateur,
vous serez amené, le cas échéant, à sélectionner le driver audio ROTEL
au niveau de la configuration audio/haut-parleurs de votre ordinateur.
REMARQUE : Le RA-1592 est compatible avec la lecture audio DSD
et DOP en modes 1X et 2X. Vérifiez la configuration de votre lecteur
audio pour confirmer la lecture correcte de ces formats audio.
REMARQUE : Le réglage de luminosité de l’écran n’est sauvegardé
de façon permanente que via la touche Menu. Les ajustements réalisés
par le bouton Bsont temporaires et ne sont pas sauvegardés quand
l’appareil est mis hors tension.
Entrée pour PC-USB q
Branchez à cette entrée le câble USB qui vous est fourni et reliez l’autre
extrémité à l’une des prises USB de votre ordinateur.
Le RA-1592 est compatible avec les modes USB Audio Class 1.0 et USB
Audio 2.0. Les ordinateurs fonctionnant sous Windows ne requièrent pas
l’installation d’un programme spécique (driver) pour le format USB Audio
Class 1.0 qui est compatible avec les formats audio jusqu’à 96 kHz de
fréquence d’échantillonnage. Par défaut, le format usine est USB Audio
Class 1.0.
Pour exploiter le mode USB Audio Class 2.0 – qui supporte la lecture jusqu’à
la fréquence d’échantillonnage de 192 KHz – il est nécessaire d’installer
sur votre ordinateur un programme (appelé également « driver ») qui se
trouve sur le CD fourni avec le RA-1592. Vous devez en outre basculer le
RA-1592 en mode de lecture USB Audio Class 2.0 en procédant de la
façon suivante :
RS232 t
Le RA-1592 peut le cas échéant être piloté via RS232 pour une intégration
au sein d’un système domotique. La prise RS232 est compatible avec un
connecteur DB-9 droit standard mâle-femelle.
Pour des informations complémentaires sur ces connexions, les aspects
logiciels et les codes de commandes compatibles avec votre RA-1592,
veuillez-vous rapprocher de votre revendeur agréé Rotel.
ROTEL LINK w
Votre appareil dispose de la possibilité d’être connecté par un câble mini-jack
stéréo 3.5 mm branché à l’entrée ROTEL LINK OUT à un amplicateur intégré
ou un lecteur de CD Rotel. Parallèlement, la prise ROTEL LINK IN permet la
connexion au réseau d’appareils Rotel équipés d’entrées ROTEL LINK OUT.
Cette fonction vous permet de faire communiquer entre eux les divers
éléments Rotel connectés, et de les piloter avec l’application Rotel Remote
App (application disponible en téléchargement depuis l’iTunes Store®).
Loading...
+ 56 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.