Rotary Inbay SL210i, 800, Inbay SL212i Installation Instruction

Page 1
I
IMPORTANT
N
N
S
S
T
T
I
SL210i/SL212i
Compact Inbay Control
(800 Series) (1Ø & 3Ø 208V-240V) (3Ø 480V)
SL210i Moveable Pad Capacity 8,000 lbs.
SL210i Capacity 10,000 lbs. SL212i Capacity 12,000 lbs.
A
A
L
L
L
L
A
A
T
T
I
O
O
N
N
I
I
I
Attention!!!
These Instructions Contain General Data. Any Deviation From Customers Prints Or Specifications Should Be Clarified Before Proceeding With Lift Installation.
Check the containment tube for holes due to shipping damage. Do not install a damaged containment tube. Contact Rotary Lift Customer Service. If the lift has a chance to be exposed to the elements, protect the lift.
*PLP20447 *
IN20481
© February 2010 by Rotary Lift. All rights reserved. CO7473.1
LP20447
N
N
S
S
T
T
R
R
U
U
C
C
T
T
I
O
O
N
N
S
S
I
Page 2
IMPORTANT
Owner: Your Installer Is Responsible For
The Concrete Floor Being Finished To
Grade Angle, NOT
To The Top Of The Lift.
Failure To Comply Will Void Warranty
Failure To Comply Will Void Warranty
Edge Of
Grade
Indicator
Concrete MUST BE Finished To Edge Of Grade Indicator, NOT The Top Of The Lift. Finished Floor Level Must Be 1/4” Below Top Of Lift On All Sides.
Concrete
Grade Indicator
IMPORTANT
Contact with the electrical heating coils could cause electrolysis and damage the lift and/or its components. Make sure the lift frame concrete anchors do not contact electrical heating coils, or re-bar that may be in contact with other embedded electrical sources. The lift being physically connected to any source which promotes electrolysis will void the warranty.
2
Page 3
Power Unit
&
Master Control Panel
Mounted On Optional Pedestal
PVC Conduit for Air and Hydraulic Hose (by Installing Contractor)
Hydraulic Hose to Lift (by Installing Contractor)
Lift (by Rotary)
Wheel Spotting Dish (by Rotary)
1/4" Air Line to Locking Latch And LDS Sensor (by Rotary)
1/4" Air Line to LDS Sensor (by Rotary)
Electrical Power Supply (by Instaliing Contractor)
Power Unit (by Rotary)
Master Control Panel (by Rotary)
In-line Air Filter (by Rotary)
1/2" Air Line to Compressor or Air Main (by Installing Contractor)
Shut Off Valve And Female Fitting (by Installing Contractor)
In-Line Pressure Regulator/Water
Separator (by Installing Contractor)
1/4" Airline To In-line Regulator (Inside Master Control Panel)
IMPORTANT!!!: After Routing The Air Lines & Hydraulic Hose Do Not Cap Either End Of Pipe Chase. Air Must Vent Out In Order For LDS To Work Properly.
IMPORTANT
IMPORTANT
Please follow these instructions to ensure a good installation and satisfactory operation of the lift. Check your shipment
against the product load list and shipping papers. Enter claims for damage or shortage with the delivering carrier at once.
• Afterinstallation,pleasereturnthisbooklettotheliterature
package and give to lift owner/operator.
• Literaturepackageshouldbekeptattachedtopowerunitfor
easy access.
• Reviewentireinstallationinstructionsbeforebeginning
excavation.
The center cover is designed for foot traffic
only.
Restrict all unauthorized persons from going near excavation. OSHA standard restricts anyone from getting in excavated hole, unless OSHA guidelines are followed. See OSHA Excavating Standard CFR 1926.
3
Page 4
Wheel Spotting Dish
2' 5"
APPROACH
PVC Conduit
Entrance for Air
& Hydraulic Hose
NOTE: Adjust Entrance For Pedestal Mounting
Installation See Fig. 8a
4' 9" Swing Arm Lifts 5' 0" Moveable Pad Lifts
WORK BENCH (TYPICAL)
12'-0" Min. to
Nearest
Obstruction
or Per
Section 1c
5'-6" Min. to nearest obstruction
Foot traffic only on center cover
SL210i Series
Wheel Spotting Dish
2' 5"
APPROACH
PVC Conduit
Entrance for Air
& Hydraulic Hose
NOTE: Adjust Entrance For Pedestal Mounting
Installation See Fig. 8a
4' 9"
WORK BENCH (TYPICAL)
13'-0" Min. to
Nearest
Obstruction
or Per
Section 1c
5'-6" Min. to nearest obstruction
SL212i Series
PVC Inlet Into Containment Tube
Foot traffic only on center cover
PVC Inlet Into Containment Tube
1. Lift Location:
IMPORTANT
Recommended Floor Slope 0-1/16" Per Ft.
Drainage Direction
Drainage Directio
n
Drain
Continuous Trench
Lift Location
5'
Concrete Floor
10'
10'
Lift Location
A. Check architect’s layout if available. Lay out lift as shown in Fig. 1. Recommended floor slope is 1/16" per foot.
Fig. 1
3. Concrete Preparation: A. Run 2" PVC from Control Area to Containment Tube. PVC will
enter the Containment Tube 9-1/2" below finished floor grade. Hole is centered horizontally in Containment Tube, Fig. 1.
B. Box out a 5' x 10' area around where lift is to be located. NOTE: For multiple lift installations, boxed out areas will overlap. Dig continuous trench, see illustration below. C. Pour concrete floor ensuring not to get concrete in boxed out
area.
NOTE: By using this installation method, the RAI can more accurately set lift to proper grade relative to finished floor. Reference Page 2.
B. SL210i: The 5' 6" centerline to side and 12' 0" centerline
to front and rear dimensions should be maintained to provide adequate working space. The minimum overhead clearance should be 85" plus height of highest vehicle to be raised. 24' 0" length bay recommended. Other lengths may be used, provided ample clearance is maintained at each end of lift. SL212i: The 5' 6" centerline to side and 13' 0" centerline to front and rear dimensions should be maintained to provide adequate working space. The minimum overhead clearance should be 88" plus height of highest vehicle to be raised. 26' 0" length bay recommended. Other lengths may be used, provided ample clearance is maintained at each end of lift. C. Base Unit Lifts: If you are planning to install roll-on/ wheel alignment runways, locate lift per instructions from superstructure manufacturer. Use superstructure manufacturer's instructions for fore and aft, side to side, and ceiling clearances.
2. Excavation: Excavate hole to dimensions shown in Fig. 2. Dig trench for 2" PVC pipe between lift and power unit location. Trench should be dug 11" below finished floor grade. Air line and hydraulic hose to be contained in this 2" PVC pipe.
4. Lift Setting:
Check the containment tube for holes due to
shipping damage. Do not install a damaged containment tube. Contact Rotary Lift Customer Service. A. Chain hoist must have capacity of 2,500 lbs. with a clear swing of 9' 0". Rig sling for unit, attaching to the shipping strap, Fig. 3, and lower assembly into hole. Center lift and be sure lift containment inlet is located as shown in Fig. 1.
4
Page 5
Frame Anchor
105"
110"
18"
73-5/8"
Frame Width
96"
Clean Pea Gravel Fill
36"
Lift & Containment Tube
7,200 lbs. maximum reaction longitudinal and transverse direction due to eccentric loads 15,000 lbs. maximum vertical loads
23-3/8" Frame
2" PVC Pipe
9-1/2"
56"
Power Unit
Wall Bracket
6"-8"
IMPORTANT
Owner: Your Installer Is Responsible For The
Lift and
Containment Tube
6 x 6's
Blocks
(2) 1/2"-13NC x 18" lg. Threaded Rod,
Flat Washers, & Nuts
60"
X
X
X
X
Shipping
Straps
Concrete Floor Being Finished To The Leading Edge Of The Grade Angle (1/4" Below Top Of Lift), NOT To The Top Of The Lift, Fig. 5. Failure To Comply Will Void Warranty.
B. Bend frame anchors out perpendicular to concrete frame and downward approximately 45° to floor level, Fig. 2. C. Remove and retain (4) 1/2"-13NC HHCS (marked with X, Fig.
3). Insert 1/2" Threaded Rods x 18" lg. into the holes and secure in place using 1/2" flat washers and nuts, Fig. 4. D. Attach 6 x 6’s to support unit on existing floor and secure in place with 1/2" flat washers and nuts, Fig. 4. Remove shipping straps and install guide barrel bolts in open holes and torque to 60 ft-lbs. Remove protective covers from top of jacks. E. Plumb and level by placing machinist level on top of jack. Do Not plumb or level off unit frame. See Fig 5.
F. Shore Lift Securely! G. Connect 2" PVC to containment tube, chamfer PVC entering
containment tube seal and lubricate I.D. of seal with grease or oil to ease entry of PVC into seal. PVC pipe should extend into containment tube 1" maximum.
NOTE: If your PVC pipe and containment inlet do not align, you may have to cut back PVC pipe, and attach 2" Flexible PVC to make connection. All PVC joints MUST be leak proof.
H. Recheck plumb.
Fig. 3
Fig. 2
Fig. 4
5
Page 6
5. Backfill:
CAUTION
IMPORTANT
X
X
XX
X
X
X
X
X
X
Tape Covers Over Plungers
Tape Covers Over Plungers
Center Cover
Grade Indicator
Leading Edge
Concrete Floor
Machinist Level
A. Duct tape joint areas indicated by X, Fig. 6, to protect these areas during backfill and concrete work. Backfill around unit using only pea gravel to within 18" of top of finished floor.
Do not use a mechanical tamper or saturate the backfill material to achieve compaction. This could cause lift containment sides to bend inward, HAND TAMP ONLY.
Do Not fill plunger with any ballast material.
B. Complete backfill and tamp pipe trench. C. After lift is backfilled, make final elevation and plumb checks,
Fig 5.
D. Make sure frame anchors are bent out, Fig. 7.
Fig. 5
Fig. 6
6
Page 7
Lift and
Containment Tube
Bend Out Frame Anchors
Rebar or Stud Anchor
Grade Indicator
Leading Edge
Concrete Floor
6. Concrete Work:
IMPORTANT
IMPORTANT
A. Leave 6 x 6's in place. B. New concrete around the lift must be keyed into existing floor
with rebar or stud anchors, Fig. 7. C. A minimum concrete strength of 3,000 PSI is suggested. DO NOT use calcium chloride as a curing accelerator. If using a curing accelerator, we recommend a non-chloride additive such as High Early* or equivalent. D. Pour concrete floor, being careful not to run concrete in and around top surface of lift unit.
Owner: Your Installer Is Responsible For The Concrete Floor Being Finished To The Leading Edge Of The Grade Angle (1/4" Below Top Of Lift), NOT To The Top Of The Lift, Fig. 7. Failure To Comply Will Void Warranty.
It is imperative that lift be set level regardless of floor slope or other factors. Trowel smooth and allow to harden.
E. After concrete is set-up, remove 6 x 6's and threaded rods. F. Reinstall the guide barrel bolts, use Loctite 242 (blue) on bolts
and torque to 60 ft.-lbs.
G. Do not use lift until concrete has achieved 3,000 PSI.
Fig. 7
7
Page 8
7. Power Unit:
Push nuts hold bolts to brackets
Lowering Valve
Fill Breather Cap
Power Unit Bracket (By Rotary)
Use (4)5/16"-18NC x 1-1/2" lg. HHCS
Use (4)5/16"-18NC Nuts and 5/16" Star Washers
When Required For Installing Tr ansformer Box (Can Be Mounted Left Or Right Side)
*For workbench installations mount transfomer box behind power unit and on the inside side wall at least 18'' above the floor. Use supplied #10 x 3/8'' tapping screws. Drill 0.136'' pilot holes.
A. Wall Mounting: For operating convenience, locate Power Unit bracket so top of bracket will be approximately 56" above floor, Fig. 2. B. Locate and mount the power unit bracket, using (4) 3/8" wall anchors, on the wall, Fig. 8. Anchors must be able to hold 20 lbs. of shear force. C. Put (4) 5/16"-18NC x 1-1/2" HHCS through wall bracket using push-nuts to hold in place, Fig. 8. D. Mount power unit, with motor up, to the power unit bracket and install (4) 5/16" nuts and lock washers, Fig.8.
8. Hose And Elbow Attachment (Hose Provided By Installer): A. Hose must meet Dayco EZ Flex 150 or equivalent specs. with
3,000 PSI minimum working pressure, 3/8" I.D. with 9/16-18THD, JIC fitting, female swivel ends.
B. Hose must be free of debris. Inspect all threads for damage. C. Install hose onto elbow adapter on power unit, Fig. 9. D. Do not route hose to lift at this time.
Fig. 8
8
Page 9
E. Pedestal Mounting: Pedestal must be anchored to the floor
Secure Pedestal To Floor With 3/8” Anchor Bolts Before Attaching Power Unit
Use (4)5/16"-18NC x 3/4" lg. HHCS
Use (4)5/16"-18NC Nuts and 5/16" Star Washers
IMPORTANT
30" From Nearest Obstacle
Power Unit Bracket (By Rotary)
with 3/8" anchor bolts before attaching power unit, Fig. 8a. F. Use base for pattern to mark holes for anchoring. Pedestal must be anchored at least 30" away from the any obstacle to allow for wiring and maintenance of the power unit, Fig 8a. G. Mount power unit bracket to pedestal with (4) 5/16"-18NC x 1-1/2" HHCS, (4) 5/16" nuts and lock washers, Fig. 8a. H. Put (4) 5/16"-18NC x 1-1/2" HHCS through power unit bracket using push-nuts to hold in place, Fig. 8b. I. Mount power unit, with motor up, to the power unit bracket and install (4) 5/16" nuts and lock washers, Fig.8b.
Fig. 8a
9
Page 10
ATTENTION
CAUTION
IMPORTANT
Use (4)5/16"-18NC x 1-1/2" lg. HHCS
Use (4)5/16"-18NC Nuts and 5/16" Star Washers
Lowering Valve
Push Nuts Hold Bolts To Bracket
Fill Breather Cap
Crimped Hose Sleeve (Typical)
Elbow Adapter
Power Unit Hose to Lift. Hose must meet Dayco EZ Flex 150 or equiv. Specs. with 3,000 PSI min. working pressure, 3/8" I.D. with 9/16-18THD JIC Fitting, Female Swivel Ends.
When Required For Installing Tr ansformer Box (Can Be Mounted Left Or Right Side)
Fig. 8b
9. Mounting Master Control Panel, Fig. 10: A. Remove front cover of Master Control by unscrewing the (4)
screws and unplugging the harness. B. Remove covering over the front of the capacitor box on the motor of the power unit and find gasket.
C. Place gasket on the front of the capacitor box, Figs. 10, 10a. D. Route (2) motor wires through gasket and the hole in the back
of Master Control Box. Fasten to indicated locations on terminal block, Figs. 10, 10a. E. Route green ground wire through gasket and fasten to the ground screw inside the capacitor box of the motor, Figs. 10, 10a. F. Have a certified electrician run appropriate power supply to the side of the capacitor box of the motor and run the ground wire and power wires through the gasket and the hole in the back of the master control box. Fasten the ground wire to the additional ground screw in back plate and fasten the (2) power wires to the indicated locations on the terminal block.
Fasten spade terminals to the ends of the wires sized for fastening to a #8 screw for 1 phase and #A6 screw for 3 phase, Fig. 10, 10a.
Fig. 9
G. Fasten the Master Control Box with the (4) M5x10 PHMS
included making sure the gasket seats between the capacitor box sides and the back of the Master Control Box, Figs. 10, 10a. H. Push excess ground and power wires into the capacitor box behind the control, Figs. 10, 10a. I. Orient bulkhead for input air to desired position and tighten securely, Figs. 10, 10a. J. Plug harness and reattach cover of the master control box, making sure all wires are inside the box and plug is above the terminal block, Figs.10, 10a.
208V. Motor damage may occur.
Never operate the motor on line voltage less than
Use separate circuit for each power supply. Protect each circuit with time delay fuse or circuit breaker. For single phase 208-230V, use 20 amp fuse, and three phase use 20 amp fuse. For three phase 460V, use 10 amp fuse. All wiring must comply with NEC and all local electrical codes.
Note: Standard single phase motor CAN NOT be run on 50Hz. line without a physical change in the motor.
Wire motor according to wiring diagram provided.
10
Page 11
Power Cable
And Strain Relief
(Provided By Installer)
Gasket
M5 x 10
Mounting Screws
Spade Te rminals
For #8 Screws
(By Installer)
Green Screw
And Ground Wire
In Motor
Capacitor Box
Orient To Desired
Position And Tighten
Securely
Green Screw
And Ground Wire
For
Power Supply
Motor Wires
Power Supply
Wires
Single Phase Rotary Power Unit
MOTOR OPERATING DATA - SINGLE PHASE
LINE VOLTAGE
208 - 230 Volts 60 HZ
NOTES:
1. Unit not suitable for use in unusual conditions. Contact Rotary for moisture and dust environment duty unit.
2. Verify Coil Rating Matches Supply Voltage
3. Motor rotation is counter clockwise when viewed from top of motor.
RUNNING MOTOR VOLTAGE RANGE
197 - 253 Volts
Fig. 10
11
Page 12
Power Cable
And Strain Relief
(Provided By Installer)
Gasket
M5 x 10
Mounting Screws
Spade Terminals
For #6 Screws
(By Installer)
Power
Supply
Wires
Motor Wires
Green Screw
And Ground Wire
In Motor
Motor Box
Orient To Desired
Position And Tighten
Securely
Green Screw
And Ground Wire
For
Power Supply
Three Phase Rotary Power Unit
MOTOR OPERATING DATA - THREE PHASE
LINE VOLTAGE
208 - 230 Volts 60 HZ
NOTES:
1. Unit not suitable for use in unusual conditions. Contact Rotary for moisture and dust environment duty unit.
2. Verify Coil Rating Matches Supply Voltage
3. Motor rotation is counter clockwise when viewed from top of motor.
RUNNING MOTOR VOLTAGE RANGE
197 - 253 Volts
Fig. 10a
12
Page 13
Power Cable From Tr ansformer
And Strain Relief
(Provided By Installer)
Controls Cable From Transformer
And Strain Relief
(Provided By Installer)
Gasket
M5 x 10
Mounting Screws
To Motor
To Motor Ground
Green Screw
And Ground Wire
In Motor
Motor Box
Orient To Desired
Position And Tighten
Securely
Green Screw
And Ground Wire
For
Power Supply
Power Supply Wire
Power Supply Wire
Control Supply Wire
Control Supply Wire
Motor Wires
Motor Wires
Transformer
For 480V
Bracket
For
Transformer
Three Phase Rotary Power Unit
MOTOR OPERATING DATA - THREE PHASE HIGH VOLTAGE
LINE VOLTAGE
460 Volts 60 HZ
NOTES:
1. Unit not suitable for use in unusual conditions. Contact Rotary for moisture and dust environment duty unit.
2. Verify Coil Rating Matches Supply Voltage
3. Motor rotation is counter clockwise when viewed from top of motor.
RUNNING MOTOR VOLTAGE RANGE
414 - 506 Volts
13
Page 14
U
D
White
White
Orange
White
DIN
Red
Red
Red
Red
Red
White
Black
Red or White
Blue
Orange
Orange
Orange
Black
Orange
Lowering
Valve
Blue
LL
Latch1
Black
Black
Black
Coil
Connector
LDS
Connector
Red
LDS*
LDS*=Liquid Detection System
Terminal Block
Green
Single Phase
208-230V
SmartLift® System Diagram
Label Part # NP839 Rev. -
L1 T1
L2 T2
MV1 TMV1
MV2 TMV2
Green
Motor
Motor Enclosure
Control Enclosure
U
D
White
White
Orange
White
DIN
Red
Red
Red
Red
Red
White
Black
Red or White
Blue
Orange
Orange
Orange
Black
Orange
Lowering
Valve
Blue
LL
Latch1
Black
Black
Black Black
Coil
Connector
LDS
Connector
Red
LDS*
LDS*=Liquid Detection System
Terminal Block
Green
Three Phase
208-230V
SmartLift® System Diagram
Label Part # NP926 Rev. -
L1 T1 L2 T2
L3 T3
MV2 TMV2
MV1 TMV1
MV3 TMV3
Green
Motor
Motor Enclosure
Control Enclosure
Black
Black
Black
14
Page 15
U
D
White
White
Orange
White
DIN
Red
Red
Red
Red
Red
Red
Black
Red or White
Blue
Orange
Orange
Orange
Black
Orange
Lowering
Valve
Blue
LL
Latch1
Black
Black
Black Black
Coil
Connector
LDS
Connector
Red
LDS*
LDS*=Liquid Detection System
Terminal Block
Green
Three Phase
480V
220V
SmartLift® System Diagram
Label Part # NP947 Rev -
L1 T1 X1 CV1
L2
L3
T2
MV2 TMV2
MV1 TMV1
X2 CV2
Green
Motor
Motor Enclosure
Control Enclosure
Black
Black
Black
Black
Black
Black
15
Page 16
NP952 Rev -
Terminal Block
TransformerIncoming
480V
L1
L2
L3
PE
L1L2L3PE
To Control Box
(480V)
To Control Box
(220V)
L1
L2
L3
PE
X1
X2
H1
H2
Power In
Control Voltage Out
Motor Voltage Out
16
Page 17
Lowering Valve Cord From Master Control Panel Plugs Into Lowering Valve Tighten Screw On To p Of Plug After Plugging In
10. Lowering Valve:
Plug Lowering Valve cord from master control panel into lowering valve on power unit, Fig. 11.
12. Adapter Extension Racks (For SL212i only), Fig. 15:
Fig. 11
17
Page 18
PVC Conduit for Air and Hydraulic Hose (by Installing Contractor)
Hydraulic Hose to Lift (by Installing Contractor)
Lift (by Rotary)
Wheel Spotting Dish (by Rotary)
1/4" Air Line to Locking Latch And LDS Sensor (by Rotary)
1/4" Air Line to LDS Sensor (by Rotary)
Electrical Power Supply (by Instaliing Contractor)
Power Unit (by Rotary)
Master Control Panel (by Rotary)
In-line Air Filter (by Rotary)
1/2" Air Line to Compressor or Air Main (by Installing Contractor)
Shut Off Valve And Female Fitting (by Installing Contractor)
In-Line Pressure Regulator/Water
Separator (by Installing Contractor)
1/4" Airline To In-line Regulator (Inside Master Control Panel)
IMPORTANT!!!: After Routing The Air Lines & Hydraulic Hose Do Not Cap Either End Of Pipe Chase. Air Must Vent Out In Order For LDS To Work Properly.
Power Unit
&
Master Control Panel
Mounted On Optional Pedestal
IMPORTANT
*LDS = Liquid Detection System
11. Supply Lines (By Installer): Remove duct tape and center cover. Set Bolts and seal aside, taking care not to damage seal. A. Hose:
1. Push the hose through the 2" PVC pipe chase from power unit to lift unit, Fig 12 & Fig. 14.
2. Install to hydraulic fitting in lift containment inlet.
B. LDS Assembly:
1. Remove sensing tube from inside of lift containment.
2. Install sensing tube into LDS valve assembly as shown, Fig. 12a. Sealant may be required on threads to ensure air tight connection. Connection must be air tight to 90 PSI. Hand tighten tube then turn an additonal 2 turns; maximum engagement is 3/8".
3. Install LDS system onto the channel that the sensing tube was shipped in, making sure to place sensing tube inside wire ties, Fig. 12b.
B. Air Lines:
to 120 psi.
1. Install in-line air filter and female 1/4" pipe to 1/4" tube fitting, Fig. 12.
2. Cut to fit 1/4” air line and attach it to the in-line air filter and inline regulator on master control panel, Fig. 13.
3. Attach 1/4" polypropylene tubing into (2) elbows on the side of the Master Control Panel, Fig 13.
Shop air supply pressure must be between 90
Fig. 12
18
Page 19
PVC Conduit
Nut And Washer
LDS Valve Assembly
Vertical Hose
Sensing Tube Shipped Inside This Channel
Fig. 12a
Fig. 12b
19
Page 20
4. Push the tubing through the 2” PVC pipe chase to the LDS*
1/4” Air Line To In-Line Air Filter
In-Line Regulator
1/4” Air Line To Air Tee In Containment Tube Attached To Air Line On Vertical Hose
1/4” Air Line To LDS Valve Assembly In Containment Tube
IMPORTANT
IMPORTANT
valve assembly, Fig. 14.
5. Cut to fit 1/4” air line and run it from air line attached to vertical hose using the union tee to the top elbow of the LDS* assembly, Fig.14, inside the lift.
NOTE: All 1/4” polypropylene air line must have a 300 PSI working pressure.
Failure to connect air lines properly will cause a
fault error on the master control panel.
After routing the air lines and hydraulic hose DO NOT cap either end of the PVC conduit. Air must vent out in order for the LDS* to work properly, Figs. 14.
Fig. 13
20
Page 21
CONTAINMENT NOT SHOWN FOR CLARITY OF VIEW
(#2) 1/4" Airline From Air Valve In Master Control Panel (Upper Elbow) Plugs Into Union Te e
PVC Conduit Back To Master Control Panel
1/4" Airline From Pressure Switch In Master Control Panel (Lower Elbow)
Hydraulic Hose Attaches To Hydraulic Fitting In Lift Containment Inlet
Cut To Fit 1/4" Airline From Union Tee to LDS Valve Assembly
LDS
IMPORTANT!!!: After Routing The Air Lines & Hydraulic Hose Do Not Cap Either End Of PVC Conduit. Air Must Vent Out In Order For LDS To Work Properly.
21
Fig. 14
Page 22
Adapter Extension Racks
Insert 4" and 8"
Extensions Into Racks
™
®
Liquid In Containment When Lit
Lower
To Lock
LOWER TO LOCKS
LOWER
RAISE
LDS LIGHT
Fig. 15
22
Page 23
A. Locate and mount adapter extension racks on the wall
IMPOR TAN T
Cylinder Rod Boss
Load Pad
CAUTIO N
convenient to the bay area using (4) 3/8" wall anchors. Anchors must be able to hold 20 lbs. of shear force.
B. Place 4" and 8" extensions into racks.
13. Fluid Filling: A. System capacity is 19 quarts. Use Dexron III ATF, or Hydraulic
Fluid that meets ISO 32 specifications.
B. Remove fill-breather cap, Fig. 8. C. Add fluid to power unit until it reaches the MIN_____ mark
on the tank.
D. Press RAISE button and raise lift to full rise, Fig. 15.
E. Press LOWER button to fully lower lift, Fig. 15. F. Bleed lift by cycling to full rise several times. G. Top off fluid to power unit until it reaches the MIN_____ mark
on the tank.
All lifts must be fully lowered before
changing or adding fluid.
If fill-breather cap is lost or broken, order a
replacement. DO NOT substitute with a solid plug.
14. Locking Latch Test; refer to Fig. 15:
A. Press RAISE button and raise lift in up position, press
LOWER TO LOCKS button and lower lift onto locks.
B. Make sure latch engages and releases.
15. Cylinder/Load Pad Test; refer to Fig. 15:
A. Press RAISE button and raise lift to full rise and press
LOWER TO LOCKS button to lower onto locks.
B. Look into the containment tube to check that the high pressure cylinder rod is in the load pad hole, Fig. 16. C. If not, use a nonmetal object (do not scratch or scar the cylinder rods), try to move the cylinder rod. If it does not move skip step D.
Fig. 16
23
Page 24
X
X
XX
X
X
X
X
X
X
Center Cover
Equalizer Beam
Bulkhead Fitting
Hydraulic Hose
Air Hose Fitting
16. Hose Tracking Test:
IMPORTANT
Have someone raise the lift while another watches the tracking of the hose between the bulkhead fitting and equalizer beam, Figs. 17. If the hose does not track between the members of the equalizer beam without rubbing, adjust bulkhead fitting as necessary.
17. Setting Cover; refer to Fig. 21: A. Insert cover seal into lip in opening, making sure all holes
align.
B. Install center cover onto seal. C. Install and tighten cover retaining bolts. Torque to 60 ft-lbs.
Clean areas indicated with X, Fig. 18, and
seal with a premium 25 year silicone.
18. Superstructure:
Sl210i Series:
A. Base Unit Lifts: Install roll-on/wheel alignment runway per instructions from superstructure manufacturer.
B. Swing Arm Superstructures:
1. Install yokes to plungers with 7/8"-9NC x 2-1/2" HHCS and
7/8" external tooth lockwasher. Torque to 150 ft-lbs, Fig. 19.
2. Grease swivel arm pins and arm holes with Lithium grease.
3. Install (4) arm assemblies using the arm pins and snap
rings.
C. Moveable Pad Assemblies:
1. Install pads on lift using 7/8”-9NC x2-1/2” HHCS and 7/8”
external tooth lockwasher and torque to 150 ft.-lbs, Fig. 20.
SL212i series:
A. Base Unit Lifts: Install roll-on/wheel alignment runway per instructions from superstructure manufacturer.
B. Swing Arm Superstructures:
1. Install yokes to plungers with 7/8"-9NC x 3-1/2" HHCS and
7/8" external tooth lockwasher. Torque to 150 ft-lbs., Fig. 21.
2. Grease swivel arm pins and arm holes with Lithium grease.
3. Install (4) arm assemblies using the arm pins and cotter
pins, Fig. 22.
19. Final Touches: A. Lag wheel spotting dish to floor using two 3/8” anchors
provided. Verify model number of lift being installed and refer to Fig. 1 for respective dimensions.
B. Raise lift and clean sand and dirt from plunger and lift area. C. Mount multiple power source label on or next to the power
unit. D. Double check to make sure the guide barrel and center cover are sealed per Step 17.
Fig. 17
Fig. 18
24
Page 25
Arm Pin
Snap Ring
7/8"-9NC x 2-1/2" HHCS
and 7/8" External Tooth
Lockwasher
7/8"-9NC x 2-1/2" HHCS
and 7/8" External Tooth
Lockwasher
7/8"-9NC x 3-1/2" HHCS & 7/8” External Tooth Lockwasher
Arm Pin
Cotter Pin
Fig. 19
Fig. 20
Fig. 22
Fig. 21
Page 26
NOTES
Page 27
NOTES
Page 28
Installer: Please return this booklet to literature
© Rotary®, Printed in U.S.A., All Rights Reserved. Unless otherwise indicated, ROTARY, DOVER and all other trademarks are property of Dover Corporation and its affiliates.
Rotary World Headquarters
2700 Lanier Drive Madison, IN 47250, USA www.rotarylift.com
North America Contact Information
Te ch. Support: p 800.445.5438 f 800.578.5438 e [email protected] Sales: p 800.640.5438 f 800.578.5438 e [email protected]
World Wide Contact Information
World Headquarters/USA: 1.812.273.1622 Canada: 1.905.812.9920 European Headquarters/Germany: +49.771.9233.0 United Kingdom: +44.178.747.7711 Australasia: +60.3.7660.0285 Latin America / Caribbean: +54.3488.431.608 Middle East / Northern Africa: +49.771.9233.0
package, and give to lift owner/ operator.
Thank You
Trained Operators and Regular Maintenance Ensures Satisfactory
Performance of Your Rotary Lift.
Contact Your Nearest Authorized Rotary Parts Distributor for Genuine Rotary Replacement Parts. See
Literature Package for Parts Breakdown.
DATE REV. CHANGE MADE
08-15-07 - New 800 Series. 03-3-09 A Added 3 Phase Control Option 11-11-09 B Added 3 Phase 460 Control Option
Loading...