Series 68 Platinum RTD
January 2015
Rosemount Series 68 Platinum Resistance Temperature Sensors measure from –50 to 400 °C (–58 to 752 °F). Series 68 Class B, Pt100-385 sensors are available in capsule, general purpose, and spring-loaded designs in sensor lengths from 1 to 48 inches.
Table 21 shows the interchangeability of the Series 68 RTD. As
an option, for maximum system accuracy, Emerson Process Management can provide sensor calibration. See Sensor
characterization (calibration) schedules– Option Code V . In
addition, Emerson Process Management offers optional sensor-to-transmitter matching capability obtainable through the use of Callendar-Van Dusen Constants. See Option Code “V”
Callendar-van Dusen Constants .
Table 21. Series 68 Interchangeability
±0.55 °C (±0.99 °F) at -50 °C (-58 °F)
±0.30 °C (±0.54 °F) at 0 °C (32 °F)
±0.80 °C (±1.44 °F) at 100 °C (212 °F)
±1.30 °C (±2.34 °F) at 200 °C (392 °F)
±1.80 °C (±3.24 °F) at 300 °C (572 °F)
±2.30 °C (±4.14 °F) at 400 °C (752 °F)
Construction
Figure 7. Construction of a Platinum Thin Film RTD
Platinum element and lead wire configurations
Single-element temperature sensors have four lead wires and may be used in 2-, 3-, and 4-wire signal conditioning systems.
Specifications
Performance specifications
Temperature range
–50 to 400 °C (–58 to 752 °F)
Effect of temperature cycling
±0.05% (0.13 °C or 0.23 °F) maximum ice-point resistance shift following 10 cycles over the specified temperature range
Stability
±0.11% 0.28 °C or 0.51 °F maximum ice-point resistance shift following 1,000 hours at maximum specified temperature (400 °C)
Maximum hysteresis
±0.1% of operating temperature range
Time constant
A. Connection Seal B. Connection Pads C. Connection Leads D. Passivation with Glass Layers
Design and construction of the Series 68 Platinum Sensors provides the optimum combination of accuracy and durability available for temperature measurements. The construction of the sensor allows for direct immersion in non-corrosive fluids at reasonable static pressures. For corrosive environments or many industrial applications, these sensors are widely used with standard thermowell assemblies.
E. Photolithography Structured
Platinum Thin Film
F. Ce ra mic Su bs trat e
12 seconds maximum required to reach 63.2% sensor response in water flowing at 3 ft/s (0.91 m/s)
Nominal R0 100 Ohm
Nominal alpha 0.00385 Ω/Ω°C
68
www.rosemount.com
January 2015
Sensors and Accessories (Volume 1)
Physical specifications
Material selection
Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser’s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected.
Sheath material
316 SST and 321 SST
Lead wire
PTFE insulated, silver plated, 24-gauge stranded copper wire
Environmental specifications
Humidity limits
Lead seal can withstand 100% relative humidity
Vibration limits
±0.05% maximum ice-point resistance shift due to 30 minutes of 14 g peak vibration from 5 to 350 Hz at 20 °C (68 °F) for unsupported stem length of less than 6 inches
Quality assurance
Each sensor is subjected to a resistance accuracy test at 0 °C and an insulation resistance test
Enclosure ratings
When installed properly, Rosemount Series 68 sensors are suitable for indoor and outdoor NEMA 4X and CSA Enclosure Type 4X installations. See Hazardous area approvals for complete installation information
Insulation resistance
1000 x 10 measured at 500 Vdc at room temperature
6
ohms minimum insulation resistance when
Identification data
The model, serial numbers, and up to six lines of permanent tagging information are etched on each sensor adapter. Stainless steel tags are available upon request.