Rohde&Schwarz FSV3004, FSV3007, FSV3013, FSV3030, FSV3044 Getting started

...
®
R&S R&S
FSVA3000/
®
FSV3000 Signal and Spectrum Analyzer Getting Started
(=NÞ×2)
This manual applies to the following R&S®FSV3000 and R&S®FSVA3000 models with firmware version 1.90 and higher:
R&S®FSV3004 (1330.5000K04) / R&S®FSVA3004 (1330.5000K05)
R&S®FSV3007 (1330.5000K07) / R&S®FSVA3007 (1330.5000K08)
R&S®FSV3013 (1330.5000K13) / R&S®FSVA3013 (1330.5000K14)
R&S®FSV3030 (1330.5000K30) / R&S®FSVA3030 (1330.5000K31)
R&S®FSV3044 (1330.5000K43) / R&S®FSVA3044 (1330.5000K44)
R&S®FSV3050 (1330.5000K50) / R&S®FSVA3050 (1330.5000K51)
© 2022 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Muenchen, Germany Phone: +49 89 41 29 - 0 Email: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Subject to change – data without tolerance limits is not binding. R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG. The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries. All other trademarks are the properties of their respective owners.
1330.8073.02 | Version 11 | R&S®FSVA3000/R&S®FSV3000
The following abbreviations are used throughout this manual: R&S®FSVA3000 is abbreviated as R&S FSVA3000. R&S®FSV3000 is abbreviated as R&S FSV3000. R&S®FSV/A refers to both the R&S FSV3000 and the R&S FSVA3000.
R&S®FSVA3000/R&S®FSV3000

Contents

1 Safety and regulatory information....................................... 9
1.1 Safety instructions................................................................................9
1.2 Warning messages in the documentation........................................12
1.3 Korea certification class A.................................................................13
2 Documentation overview.................................................... 14
2.1 Getting started manual.......................................................................14
2.2 User manuals and help.......................................................................14
2.3 Service manual....................................................................................15
Contents
2.4 Instrument security procedures........................................................ 15
2.5 Printed safety instructions.................................................................15
2.6 Data sheets and brochures................................................................15
2.7 Release notes and open-source acknowledgment (OSA).............. 16
2.8 Application notes, application cards, white papers, etc................. 16
3 Welcome to the R&S FSV/A................................................ 17
3.1 Key features........................................................................................ 17
3.2 Described options...............................................................................18
4 Key features......................................................................... 19
5 Preparing for use................................................................. 20
5.1 Lifting and carrying............................................................................ 20
5.2 Unpacking and checking....................................................................20
5.3 Choosing the operating site.............................................................. 21
5.4 Setting up the R&S FSV/A..................................................................21
5.4.1 Placing the R&S FSV/A on a bench top................................................22
5.4.2 Mounting the R&S FSV/A in a rack.......................................................23
3Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
5.5 Connecting the AC power.................................................................. 23
5.6 Switching the instrument on and off.................................................24
5.7 Connecting to LAN............................................................................. 26
5.8 Connecting a keyboard...................................................................... 27
5.9 Connecting an external monitor........................................................28
5.10 Windows operating system................................................................29
5.11 Logging on.......................................................................................... 31
5.12 Checking the supplied options..........................................................34
5.13 Performing a self-alignment.............................................................. 34
5.14 Considerations for test setup............................................................ 35
5.15 Protecting data using the secure user mode................................... 36
Contents
6 Instrument tour.................................................................... 39
6.1 Front panel view..................................................................................39
6.1.1 Power key............................................................................................. 40
6.1.2 USB.......................................................................................................40
6.1.3 System keys..........................................................................................40
6.1.4 Touchscreen..........................................................................................41
6.1.5 Function keys........................................................................................43
6.1.6 Removable solid state drive (SSD)....................................................... 45
6.1.7 Navigation controls............................................................................... 45
6.1.7.1 Rotary knob...........................................................................................45
6.1.7.2 Navigation keys.....................................................................................46
6.1.7.3 Undo/redo keys.....................................................................................46
6.1.8 Trigger input / output.............................................................................47
6.1.9 RF input 50 ohm................................................................................... 47
6.1.10 Probe.................................................................................................... 47
6.1.11 Ext mixer connector (optional).............................................................. 48
4Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
6.1.12 Noise source control / power sensor.....................................................48
6.1.13 AF out and volume (R&S FSV3-B3)..................................................... 48
6.1.14 Keypad..................................................................................................48
6.2 Rear panel view...................................................................................49
6.2.1 AC power supply connection and main power switch...........................51
6.2.2 HDMI display port................................................................................. 51
6.2.3 LAN....................................................................................................... 51
6.2.4 USB.......................................................................................................51
6.2.5 GPIB interface.......................................................................................52
6.2.6 Noise source control............................................................................. 52
6.2.7 Trigger 2/3 in/out...................................................................................52
Contents
6.2.8 REF input / REF output.........................................................................52
6.2.9 IF output................................................................................................53
6.2.10 Video output..........................................................................................53
6.2.11 Aux. port................................................................................................53
6.2.12 Aux. control........................................................................................... 54
6.2.13 External generator control option (R&S FSV3-B10)............................. 54
6.2.14 OCXO option (R&S FSV3-B4).............................................................. 54
6.2.15 Labels on R&S FSV/A...........................................................................54
6.2.16 Device ID.............................................................................................. 55
7 Trying out the instrument................................................... 56
7.1 Measuring a basic signal................................................................... 56
7.2 Displaying a spectrogram.................................................................. 59
7.3 Activating additional measurement channels..................................61
7.4 Performing sequential measurements..............................................66
7.5 Setting and moving a marker.............................................................67
7.6 Displaying a marker peak list............................................................ 69
5Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
7.7 Zooming into the display................................................................... 71
7.8 Zooming into the display permanently............................................. 74
7.9 Saving settings................................................................................... 78
7.10 Printing and saving results................................................................80
Contents
8 Operating the instrument....................................................82
8.1 Understanding the display information............................................ 82
8.1.1 Channel bar.......................................................................................... 84
8.1.2 Window title bar.................................................................................... 88
8.1.3 Marker information................................................................................ 89
8.1.4 Frequency and span information in diagram footer.............................. 90
8.1.5 Instrument and status information.........................................................91
8.1.6 Error information................................................................................... 92
8.2 Accessing the functionality............................................................... 93
8.2.1 Toolbar.................................................................................................. 93
8.2.2 Softkeys................................................................................................ 96
8.2.3 Context menus......................................................................................96
8.2.4 On-screen keyboard............................................................................. 98
8.3 Entering data....................................................................................... 98
8.3.1 Entering numeric parameters................................................................99
8.3.2 Entering alphanumeric parameters.....................................................100
8.4 Touchscreen gestures...................................................................... 102
8.5 Displaying results............................................................................. 106
8.5.1 Activating and deactivating channels..................................................106
8.5.2 Laying out the result display with the smartgrid.................................. 108
8.5.2.1 Background information: the smartgrid principle.................................109
8.5.2.2 How to activate smartgrid mode..........................................................110
8.5.2.3 How to add a new result window.........................................................111
6Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
8.5.2.4 How to close a result window.............................................................. 111
8.5.2.5 How to arrange the result windows..................................................... 112
8.5.3 Changing the size of windows.............................................................112
8.5.4 Switching between a split and maximized window display..................113
8.5.5 Changing the display...........................................................................114
8.6 Getting help....................................................................................... 114
Contents
9 Contacting customer support...........................................116
Index....................................................................................117
7Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Contents
8Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Safety and regulatory information
Safety instructions

1 Safety and regulatory information

The product documentation helps you use the product safely and efficiently. Fol­low the instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of elec­tronic components and devices in industrial, administrative, and laboratory envi­ronments. Use the product only for its designated purpose. Observe the operating conditions and performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dangers and gives instructions on how to prevent personal injury or damage caused by dangerous situations. Safety information is provided as follows:
In Chapter 1.1, "Safety instructions", on page 9. The same information is provided in many languages as printed "Safety Instructions". The printed "Safety Instructions" are delivered with the product.
Throughout the documentation, safety instructions are provided when you need to take care during setup or operation.

1.1 Safety instructions

Products from the Rohde & Schwarz group of companies are manufactured according to the highest technical standards. To use the products safely, follow the instructions provided here and in the product documentation. Keep the prod­uct documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Inten­ded use and limits are described in the product documentation such as the data sheet, manuals and the printed "Safety Instructions". If you are unsure about the appropriate use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users also need sound knowledge of at least one of the languages in which the user interfaces and the product documentation are available.
9Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Never open the casing of the product. Only service personnel authorized by Rohde & Schwarz are allowed to repair the product. If any part of the product is damaged or broken, stop using the product. Contact Rohde & Schwarz customer service at http://www.customersupport.rohde-schwarz.com.
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. To move the product safely, you can use lifting or transporting equipment such as lift trucks and forklifts. Follow the instructions provided by the equipment manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters can electrically connect the casing with live parts, which can lead to elec­tric shock, serious personal injury or death if you touch the casing. If Rohde & Schwarz provides accessories designed for your product, e.g. a carrying bag, you can use the product outdoors.
Safety and regulatory information
Safety instructions
Unless otherwise specified, you can operate the product up to an altitude of 2000 m above sea level. The product is suitable for pollution degree 2 environ­ments where nonconductive contamination can occur. For more information on environmental conditions such as ambient temperature and humidity, see the data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the product facing down. If the product is designed for different positions, secure the product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure stability. The feet can collapse if they are not folded out completely or if the prod­uct is moved without lifting it. The foldable feet are designed to carry the weight of the product, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and stability. Observe the specifications of the rack manufacturer. Always install the products from the bottom shelf to the top shelf so that the rack stands securely. Secure the product so that it cannot fall off the rack.
10Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Connecting to power
The product is an overvoltage category II product. Connect the product to a fixed installation used to supply energy-consuming equipment such as household appliances and similar loads. Keep in mind that electrically powered products have risks, such as electric shock, fire, personal injury or even death.
Take the following measures for your safety:
Before switching on the product, ensure that the voltage and frequency indica­ted on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
Only use the power cable delivered with the product. It complies with country­specific safety requirements. Only insert the plug into an outlet with protective conductor terminal.
Only use intact cables and route them carefully so that they cannot be dam­aged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
Safety and regulatory information
Safety instructions
If the product needs an external power supply, use the power supply that is delivered with the product or that is recommended in the product documenta­tion or a power supply that conforms to the country-specific regulations.
Only connect the product to a power source with a fuse protection of maxi­mum 20 A.
Ensure that you can disconnect the product from the power source at any time. Pull the power plug to disconnect the product. The power plug must be easily accessible. If the product is integrated into a system that does not meet these requirements, provide an easily accessible circuit breaker at the system level.
Using headphones
Take the following measures to prevent hearing damage. Before using head­phones, check the volume and reduce it if necessary. If you monitor varying sig­nal levels, take off the headphones and wait until the signal has settled. Then adjust the volume.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the casing is not waterproof. Do not use liquid cleaning agents.
11Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Safety and regulatory information
Warning messages in the documentation
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard Read the product documentation to avoid personal injury or product damage.
Electrical hazard Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal Connect this terminal to a grounded external conductor or to protective ground. This
connection protects you against electric shock if an electric problem occurs.

1.2 Warning messages in the documentation

A warning message points out a risk or danger that you need to be aware of. The signal word indicates the severity of the safety hazard and how likely it will occur if you do not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoi­ded.
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other property.
12Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Safety and regulatory information
Korea certification class A

1.3 Korea certification class A

이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하 시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
13Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Documentation overview
User manuals and help

2 Documentation overview

This section provides an overview of the R&S FSV/A user documentation. Unless specified otherwise, you find the documents at:
www.rohde-schwarz.com/manual/FSVA3000
www.rohde-schwarz.com/manual/FSV3000
Further documents are available at:
www.rohde-schwarz.com/product/FSVA3000
www.rohde-schwarz.com/product/FSV3000

2.1 Getting started manual

Introduces the R&S FSV/A and describes how to set up and start working with the product. Includes basic operations, typical measurement examples, and general information, e.g. safety instructions, etc.
A printed version is delivered with the instrument. A PDF version is available for download on the Internet.

2.2 User manuals and help

Separate user manuals are provided for the base unit and the firmware applica­tions:
Base unit manual Contains the description of all instrument modes and functions. It also pro­vides an introduction to remote control, a complete description of the remote control commands with programming examples, and information on mainte­nance, instrument interfaces and error messages. Includes the contents of the getting started manual.
Firmware application manual Contains the description of the specific functions of a firmware application, including remote control commands. Basic information on operating the R&S FSV/A is not included.
14Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
The contents of the user manuals are available as help in the R&S FSV/A. The help offers quick, context-sensitive access to the complete information for the base unit and the firmware applications.
All user manuals are also available for download or for immediate display on the Internet.
Documentation overview
Data sheets and brochures

2.3 Service manual

Describes the performance test for checking the rated specifications, module replacement and repair, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists.
The service manual is available for registered users on the global Rohde & Schwarz information system (GLORIS):
R&S®FSVA3000/FSV3000 Service manual

2.4 Instrument security procedures

Deals with security issues when working with the R&S FSV/A in secure areas. It is available for download on the Internet.

2.5 Printed safety instructions

Provides safety information in many languages. The printed document is deliv­ered with the product.

2.6 Data sheets and brochures

The data sheet contains the technical specifications of the R&S FSV/A. It also lists the firmware applications and their order numbers, and optional accessories.
The brochure provides an overview of the instrument and deals with the specific characteristics.
15Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Application notes, application cards, white papers, etc.
See www.rohde-schwarz.com/brochure-datasheet/FSV3000 /
www.rohde-schwarz.com/brochure-datasheet/FSVA3000
Documentation overview
2.7 Release notes and open-source acknowledg­ment (OSA)
The release notes list new features, improvements and known issues of the cur­rent firmware version, and describe the firmware installation.
The software makes use of several valuable open source software packages. An open-source acknowledgment document provides verbatim license texts of the used open source software.
See www.rohde-schwarz.com/firmware/FSV3000 /
www.rohde-schwarz.com/firmware/FSVA3000

2.8 Application notes, application cards, white papers, etc.

These documents deal with special applications or background information on particular topics.
See www.rohde-schwarz.com/application/FSV3000 /
www.rohde-schwarz.com/application/FSVA3000
16Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Welcome to the R&S FSV/A
Key features

3 Welcome to the R&S FSV/A

3.1 Key features

The R&S FSV3000 Signal and Spectrum Analyzer and the R&S FSVA3000 Sig­nal and Spectrum Analyzer set standards in RF performance and usability. Key features are:
Wide analysis bandwidth (up to 200 MHz for the FSV3000 and up to 1 GHz for the FSVA3000)
Very high measurement speed
Low phase noise
Excellent dynamic range
Smart wizards for fast setup of complex measurement tasks
SCPI recorder
Virtual one box instrument with a Rohde & Schwarz signal generator
Multiple measurement applications can be run and displayed in parallel
Optional measurement applications for demodulation of analog and digital modulated signals
For a detailed specification, refer to the data sheet.
Due to these features, the R&S FSV3000 and the R&S FSVA3000 are ideal for various measurement tasks, for instance:
Functional check and repair in service and maintenance due to the excellent usability
Measurements on 5G NR and other wireless standards with the optional mea­surement applications for cellular and WLAN standards
Production of components due to the high measurement speed
Analysis of wideband modulated signals, short events or the linearization of amplifiers due to the wide analysis bandwidth
Measuring oscillators due to the low phase noise
Identifying and analyzing spurious emissions due to the large spurious-free dynamic range and low DANL
17Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Welcome to the R&S FSV/A

3.2 Described options

In addition to the base unit, the following options are described:
Option Description
Described options
R&S®FSV3-B3 (1330.3765.02)
R&S®FSV3-B4 (1330.3794.02)
R&S®FSV3-B5 (1330.3820.02)
R&S®FSV3-B6 (1330.3913.02)
R&S®FSV3-B10 (1330.3859.02)
R&S®FSV3-B11 (1330.3865.02)
R&S®FSV3-B20 (1330.3971.02)
R&S®FSV3-B21 (1330.4010.26)
R&S®FSV3-B24 (1330.4049.XX)
R&S®FSV3-B25 (1330.4078.02)
R&S®FSV3-B40 (1330.4103.02)
R&S®FSV3-B200 (1330.4132.02)
R&S®FSV3-B400 (1330.7154.02)
R&S®FSV3-B1000 (1346.3699.02)
Audio demodulator
OCXO frequency reference
Additional interfaces
10 Gbit/s LAN interface
External generator control
YIG preselector bypass
Removable hard drive
External mixer
Preamplifier
Electronic attenuator
40 MHz analysis bandwidth extension
200 MHz analysis bandwidth extension
400 MHz analysis bandwidth extension
1 GHz analysis bandwidth extension
R&S®FSV3-B54G (1346.6369.02)
R&S®FSV3-B114 (1330.4910.02)
R&S®FSV3-K3 (1346.3676.02)
R&S®FSV3-K33 (1346.3360.02)
R&S®FSV3-K553 (1346.4889.02)
54 GHz frequency extension
Enhanced computing power
Power sensor support
Security write protection
External frontend support
18Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Key features

4 Key features

The R&S FSV3000 Signal and Spectrum Analyzer and the R&S FSVA3000 Sig­nal and Spectrum Analyzer set standards in RF performance and usability. Key features are:
Wide analysis bandwidth (up to 200 MHz for the FSV3000 and up to 1 GHz for the FSVA3000)
Very high measurement speed
Low phase noise
Excellent dynamic range
Smart wizards for fast setup of complex measurement tasks
SCPI recorder
Virtual one box instrument with a Rohde & Schwarz signal generator
Multiple measurement applications can be run and displayed in parallel
Optional measurement applications for demodulation of analog and digital modulated signals
For a detailed specification, refer to the data sheet.
Due to these features, the R&S FSV3000 and the R&S FSVA3000 are ideal for various measurement tasks, for instance:
Functional check and repair in service and maintenance due to the excellent usability
Measurements on 5G NR and other wireless standards with the optional mea­surement applications for cellular and WLAN standards
Production of components due to the high measurement speed
Analysis of wideband modulated signals, short events or the linearization of amplifiers due to the wide analysis bandwidth
Measuring oscillators due to the low phase noise
Identifying and analyzing spurious emissions due to the large spurious-free dynamic range and low DANL
19Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Unpacking and checking
Preparing for use

5 Preparing for use

Here, you can find basic information about setting up the product for the first time.
Lifting and carrying..........................................................................................20
Unpacking and checking................................................................................. 20
Choosing the operating site............................................................................ 21
Setting up the R&S FSV/A.............................................................................. 21
Connecting the AC power............................................................................... 23
Switching the instrument on and off................................................................ 24
Connecting to LAN.......................................................................................... 26
Connecting a keyboard................................................................................... 27
Connecting an external monitor...................................................................... 28
Windows operating system............................................................................. 29
Logging on...................................................................................................... 31
Checking the supplied options........................................................................ 34
Performing a self-alignment............................................................................ 34
Considerations for test setup.......................................................................... 35
Protecting data using the secure user mode...................................................36

5.1 Lifting and carrying

The carrying handles are designed to lift or carry the instrument. Do not apply excessive external force to the handles.
See "Lifting and carrying the product" on page 10.

5.2 Unpacking and checking

1. Unpack the R&S FSV/A carefully.
2. Retain the original packing material. Use it when transporting or shipping the
R&S FSV/A later.
3. Using the delivery notes, check the equipment for completeness.
20Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Setting up the R&S FSV/A
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact Rohde & Schwarz.
Preparing for use

5.3 Choosing the operating site

Specific operating conditions ensure proper operation and avoid damage to the product and connected devices. For information on environmental conditions such as ambient temperature and humidity, see the data sheet.
See also "Choosing the operating site" on page 10.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate the product. The EMC class of the product is given in the data sheet.
Class B equipment is suitable for use in: – Residential environments – Environments that are directly connected to a low-voltage supply network
that supplies residential buildings
Class A equipment is intended for use in industrial environments. It can cause radio disturbances in residential environments due to possible conducted and radiated disturbances. It is therefore not suitable for class B environments. If class A equipment causes radio disturbances, take appropriate measures to eliminate them.

5.4 Setting up the R&S FSV/A

The R&S FSV/A is designed for use on a bench top or in a rack.
See also:
"Setting up the product" on page 10
"Intended use" on page 9
21Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Setting up the R&S FSV/A
Preparing for use

5.4.1 Placing the R&S FSV/A on a bench top

To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface
can support the weight of the product. For information on the weight, see the data sheet.
2. CAUTION! Foldable feet can collapse. See "Setting up the product"
on page 10. Always fold the feet completely in or out. With folded-out feet, do not place
anything on top or underneath the product.
3. WARNING! A stack of products can fall over and cause injury. Never stack
more than three products on top of each other. Instead, mount them in a rack. Stack as follows:
It is best if all products have the same dimensions (width and length).
The overall load on the lowest product must not exceed 500 N.
With smaller products on top of the lowest product, the overall load on the lowest product must not exceed 250 N.
4. NOTICE! Overheating can damage the product. Prevent overheating as follows:
Keep a minimum distance of 10 cm between the fan openings of the prod-
uct and any object in the vicinity.
Do not place the product next to heat-generating equipment such as radia-
tors or other products.
22Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Connecting the AC power
Preparing for use

5.4.2 Mounting the R&S FSV/A in a rack

To prepare the rack
1. Observe the requirements and instructions in "Setting up the product" on page 10.
2. NOTICE! Insufficient airflow can cause overheating and damage the product. Design and implement an efficient ventilation concept for the rack.
To mount the R&S FSV/A in a rack
1. Use an adapter kit to prepare the R&S FSV/A for rack mounting. a) Order the rack adapter kit designed for the R&S FSV/A. For the order
number, see the data sheet.
b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Lift the R&S FSV/A to shelf height.
3. Grab the handles and push the R&S FSV/A onto the shelf until the rack brack­ets fit closely to the rack.
4. Tighten all screws in the rack brackets with a tightening torque of 1.2 Nm to secure the R&S FSV/A in the rack.
To unmount the R&S FSV/A from a rack
1. Loosen the screws at the rack brackets.
2. Remove the R&S FSV/A from the rack.
3. If placing the R&S FSV/A on a bench top again, unmount the adapter kit from the R&S FSV/A. Follow the instructions provided with the adapter kit.

5.5 Connecting the AC power

In the standard version, the R&S FSV/A is equipped with an AC power supply connector.
23Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Preparing for use
Switching the instrument on and off
The R&S FSV/A can be used with different AC power voltages and adapts itself automatically to it. Refer to the data sheet for the requirements of voltage and fre­quency.
For safety information, see "Connecting to power" on page 11.
To connect the AC power
1. Plug the AC power cable into the AC power connector on the rear panel of the instrument. Only use the AC power cable delivered with the R&S FSV/A.
2. Plug the AC power cable into a power outlet with ground contact. The required ratings are listed next to the AC power connector and in the data
sheet.
For details on the connector, refer to Chapter 6.2.1, "AC power supply connection
and main power switch", on page 51.

5.6 Switching the instrument on and off

Table 5-1: Overview of power states
Status LED on Power key Position of main power switch
Off
Standby
Ready
gray
orange
green
To switch on the R&S FSV/A
[0]
[I]
[I]
The R&S FSV/A is off but connected to power.
1. Set the switch on the power supply to position [I]. See Chapter 6.2.1, "AC power supply connection and main power switch", on page 51.
24Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Switching the instrument on and off
The LED of the Power key is orange. See Chapter 6.1.1, "Power key", on page 40. Note: If the R&S FSV/A was disconnected from power before it was switched
off regularly, it automatically switches back on when the power is reconnected. Using a LAN-controlled power switch, you can take advantage of this behavior to switch the device on and off remotely.
2. Press the Power key. See Table 5-1.
The LED changes to green. The R&S FSV/A boots.
After booting, the instrument is ready for operation.
Warm-up time for OCXO
Preparing for use
When the instrument is switched on, the OCXO requires an extended warm­up time (see data sheet).
To shut down the product
The product is in the ready state.
► Press the [Power] key.
The operating system shuts down. The LED changes to orange.
If the instrument temperature exceeds the limit specified in the data sheet, the R&S FSV/A automatically shuts down to protect the instrument from damage.
To disconnect from power
The R&S FSV/A is in the standby state.
1. NOTICE! Risk of data loss. If you disconnect the product from power when it is in the ready state, you can lose settings and data. Shut it down first.
Set the switch on the power supply to position [0]. See Chapter 6.2.1, "AC power supply connection and main power switch", on page 51.
The LED of the standby key is switched off.
25Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
2. Disconnect the R&S FSV/A from the power source.
Preparing for use
Connecting to LAN

5.7 Connecting to LAN

You can connect the instrument to a LAN for remote operation via a PC.
For details on the connector, see Chapter 6.2.3, "LAN", on page 51.
Provided the network administrator has assigned you the appropriate rights and adapted the Windows firewall configuration, you can use the interface, for exam­ple:
To transfer data between a controlling device and the test device, e.g. to run a remote control program
To access or control the measurement from a remote computer using the "Remote Desktop" application (or a similar tool)
To connect external network devices (e.g. printers)
To transfer data from a remote computer and back, e.g. using network folders
Network environment
Before connecting the product to a local area network (LAN), consider the follow­ing:
Install the latest firmware to reduce security risks.
For internet or remote access, use secured connections, if applicable.
Ensure that the network settings comply with the security policies of your com­pany. Contact your local system administrator or IT department before con­necting your product to your company LAN.
When connected to the LAN, the product may potentially be accessed from the internet, which may be a security risk. For example, attackers might mis­use or damage the product. For more information about IT security and how to operate the product in a secure LAN environment, see the Rohde & Schwarz white paper 1EF96: Malware Protection Windows 10.
NOTICE! Risk of network failure.
Consult your network administrator before performing the following tasks:
Connecting the instrument to the network
Configuring the network
Changing IP addresses
26Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Exchanging hardware Errors can affect the entire network. Connect the R&S FSV/A to the LAN via the LAN interface on the rear panel of
the instrument. Windows automatically detects the network connection and activates the
required drivers.
By default, the R&S FSV/A is configured to use DHCP and no static IP address is configured.
The default instrument name is <Type><variant>-<serial_number>, for example, FSV3004-123456. For information on determining the serial num­ber, see Chapter 6.2.16, "Device ID", on page 55.
For more information on LAN configuration, see the R&S FSV/A user manual.
Preparing for use
Connecting a keyboard

5.8 Connecting a keyboard

The keyboard is detected automatically when it is connected. The default input language is English – US.
However, you can also connect foreign language keyboards; currently the follow­ing languages are supported for the R&S FSV/A:
German
Swiss
French
Russian
To configure the keyboard language
1. To access the Windows operating system, press the Windows key on the external keyboard.
2. Select "Start > Settings > Time & language > Region & language > Add a lan­guage" .
27Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Connecting an external monitor
Preparing for use

5.9 Connecting an external monitor

You can connect an external monitor (or projector) to the "HDMI" connector on the rear panel of the R&S FSV/A (see also Chapter 6.2.2, "HDMI display port", on page 51).
Screen resolution and format
The touchscreen of the R&S FSV/A is calibrated for a 16:10 format. If you connect a monitor or projector using a different format (e.g. 4:3), the calibra­tion is not correct and the screen does not react to your touch actions prop­erly.
The touchscreen has a screen resolution of 1280x800 pixels. Usually, the display of the external monitor is a duplicate of the instrument's monitor.
If you configure the external monitor to be used as the only display in the Windows configuration dialog box ("Show only on 2"), the maximum screen resolution of the monitor is used. In this case, you can maximize the R&S FSV/A application window and see even more details. You cannot change the monitor's screen resolution via the standard Windows configura­tion dialog box.
However, you can restore the default instrument resolution (1280x800) on the monitor using the instrument function "Setup" > "Display" > "Configure Monitor" > "Screen Resolution: Restore to default".
The R&S FSV/A supports a minimum resolution of 1280x768 pixels.
1. Connect the external monitor to the R&S FSV/A.
2. Press the [Setup] key.
3. Press the "Display" softkey.
4. Select the "Configure Monitor" tab in the "Display" dialog box. The standard Windows "Screen Resolution" dialog box is displayed.
28Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Preparing for use
Windows operating system
5. Select the instrument for display:
"Display 1" : internal monitor only
"Display 2" : external monitor only
"Duplicate" : both internal and external monitor
6. Tap "Apply" to try out the settings before they are accepted permanently, then you can easily return to the previous settings, if necessary.
7. Select "OK" if the settings are suitable.

5.10 Windows operating system

The instrument contains the Windows 10 operating system which has been con­figured according to the instrument's features and needs. Changes in the system setup are only required when peripherals like a keyboard or a printer are installed or if the network configuration does not comply with the default settings. After the R&S FSV/A is started, the operating system boots and the instrument firmware is started automatically.
29Getting Started 1330.8073.02 ─ 11
R&S®FSVA3000/R&S®FSV3000
Windows operating system
Tested software
The drivers and programs used on the instrument under Windows 10 are adapted to the instrument. Only install update software released by Rohde & Schwarz to modify existing instrument software.
You can install additional software on the instrument; however, additional soft­ware can impair instrument function. Thus, run only programs that Rohde & Schwarz has tested for compatibility with the instrument software.
The following program packages have been tested:
R&S Power Viewer Plus - virtual power meter for displaying results of the power sensor R&S NRPxx (install only this component!)
Symantec Endpoint Security – virus-protection software
FileShredder - for reliable deletion of files on the hard disk
Service packs and updates
Preparing for use
Microsoft regularly creates security updates and other patches to protect Win­dows-based operating systems. They are released through the Microsoft Update website and associated update server. Update instruments using Windows regu­larly, especially instruments that connect to a network.
Firewall settings
A firewall protects an instrument by preventing unauthorized users from gaining access to it through a network. Rohde & Schwarz highly recommends using the firewall on your instrument. Rohde & Schwarz instruments are shipped with the Windows firewall enabled. All ports and connections for remote control are enabled.
Note that changing firewall settings requires administrator rights.
Virus protection
Take appropriate steps to protect your instruments from infection. Use strong fire­wall settings and scan any removable storage device used with a Rohde & Schwarz instrument regularly. It is also recommended that you install anti-virus software on the instrument. Rohde & Schwarz does NOT recommend running anti-virus software in the background ("on-access" mode) on Windows­based instruments, due to potentially degrading instrument performance. How­ever, Rohde & Schwarz does recommend running it during non-critical hours.
30Getting Started 1330.8073.02 ─ 11
Loading...
+ 91 hidden pages