RODE Microphones Classic II Instruction Manual

Classic II
Instruction Manual
www.rodemic.com
(
EMC, LVD
)
Introduction
This valve microphone represents the finest studio microphone technology currently available. We know that it will serve you well for many years and provide you with a performance you will be extremely proud of.
The Classic II has been developed from the original Classic, both of which are the preferred valve microphone of a huge number of professional engineers and musicians.
The character of the original Classic has been retained, but by utilising a revised edge-terminated diaphragm, and further refining the electronic circuitry, a new level of performance has been
Classic II.
achieved.
Please take the time to visit www.rodemic.com and register your microphone for a full ten year warranty.
While there you can view studio tips and techniques, as well as browse the comprehensive range of accessories for
Peter Freedman
Microphones
Sydney, Australia
microphones.
- 2 -
Specifi cations
Acoustic Principle:
Directional Pattern:
Frequency Range:
Output Impedence:
Sensitivity: -37dB re 1V/Pa
Equivalent Noise: <18 SPL
Maximum Output:
Pressure gradient
Switchable Omnidirectional/ Cardioid / Figure-8 in nine steps (see graph)
20 Hz-20 kHz (see graph)
200Ω
(14mV @ 94dB SPL) +/-2dB
(A - weighted per IEC651)
+2d Bu (@ 1kHz, 1% THD into 1KΩ)
Dynamic Range: >113 dB SPL
(A - weighted per IEC651)
Maximum SPL: 131dB SPL
(@ 1kHz, 1% THD into 1KΩ)
Signal/Noise: > 76dB SPL
(A - weighted per IEC651)
Power Requirement:
Net Weight: 1440gm
Packed Weight: 9kg
Dedicated Power Supply
(110 ~ 120V/220 ~ 240V, 50/60 Hz)
- 3 -
Specifi cations
Frequency Response
20
10
0
-10 dB re 1 V/Pa
-20
-30
20Hz 100 1000 10 000 20 000
Cardioid
20
10
0
-10 dB re 1 V/Pa
-20
-30
20Hz 100 1000 10 000 20 000
Omni
Polar Response
0
-10
-20 300
-30
-40
-50
-60
270
-55
-45
-35
-25
240
-15
-5
5
0
-5
-10 300
-15
-20
-25
270
-30
-25
-20
-15 240
-10
-5
0
330
210
330
210
0
180
Cardioid
0
180
Omni
30
150
30
150
60
120
60
120
250 Hz 1 kHz 4 kHz
90
250 Hz 1 kHz 4 kHz
90
- 4 -
Specifi cations
0
-10
-20
-30
-40
-50
-60
-70 270
-65
-55
-45
-35
-25
-15
-5
5
330
300
240
210
0
180
30
60
120
150
Figure 8
Features
• Custom spec 1” dual diaphragm capsule
• Vintage twin triode GE JAN-6072 valve
250 Hz 1 kHz 4 kHz
90
• Nine polar patterns
• Jensen output transformer
• Variable Pad & Filter
• Machined from solid brass
• Hand-polished body
• Double-shielded oxygen-free 9m (30’) cable
• Heavy-duty plugs and sockets
• Aluminum flight case
• Made in Australia
• 10 Year warranty*
*Online product registration required.
- 5 -
Loading...
+ 11 hidden pages