Rockwell Automation MV SMC Flex OEM Components User Manual

MV SMC Flex OEM Components Interface Board – Instruction Sheet
Handling
A T T E N T I O NA T T E N T I O N
Carefully unpack the item and inspect it for damage that may have
occurred during shipping. Immediately report any damage to the claims office of the carrier. Rockwell Automation will render reasonable assistance in resolving a damage claim.
Do not touch or bend the connectors on the Interface Board when handling it. Damage to the connectors may result in loss of communication signals from the MV SMC Flex to other components.
A T T E N T I O NA T T E N T I O N
Interface BoardInterface Board
To guard against electrostatic damage (ESD) to equipment the following precautions should be observed when handling electrostatic sensitive devices.
1) Use a grounding wrist strap to minimize the build up of static charge on personnel.
2) Handle the module by the edges and avoid touching components or printed circuit paths.
3) Store devices with sensitive components in the conductive packaging that the module is shipped in.
These precautions are the minimum requirements for guarding against ESD. For more information refer to Guarding Against Electrostatic Damage - Publication 8000-4.5.2.
Electrical components may be damaged or destroyed by electrostatic charges that build up in personnel during normal activities. To avoid damage to the equipment, observe the following precautions.
2 Interface Board – Instruction Sheet
Identification Verify the catalog number of the interface board.
Table 1 – Interface Board Catalog Number
System Voltage
800V to 6900V
Note: The following items are supplied with the Interface Board:
• Connectors 80174-014-01 and 80174-014-02
• Ribbon cable assembly 80026-146-53
• Interface cables (6-pin) 80174-201-01 (Qty 2), and (8-pin) 80174-201-02 (Qty 3)
• Mounting bracket, stand-offs and screws
Control Circuit Voltage
and Frequency
110/120 to 220/240 VAC
50/60 Hz
Catalog Number
1503E-INTB
Storage If the interface board will not be installed immediately after receipt,
store it in a clean, dry and dust-free environment. Humidity should not exceed 95%, non-condensing.
Installation Refer to MV SMC Flex OEM Components – Bulletin 1503E,
Installation Instructions (Publication 1503E-IN001_-EN-P) for
complete installation instructions of the Interface Board.
Additional Publications To order additional copies of Instruction Manuals for all Rockwell
Automation medium voltage products, please contact a Rockwell Automation sales office or your local distributor.
Medium Voltage Products, 135 Dundas Street, Cambridge, ON, N1R 5X1 Canada, Tel: (1) 519.740.4100, Fax: (1) 519.623.8930, www.ab.com/mvb
Publication 1503E-IN002C-EN-E – May 2008 Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Printed in Canada.
Supersedes Publication 1503E-IN00 2B-EN-P – January 2006