Rockwell Automation MPMA User Manual

Installation Instructions
a) Mark needed strip length.
b) Mark strip width centerline.
c) Make two 45º marks to centerline.
d) Use tin snips to cut along 45º marks.
Linear Stage Strip Seal Replacement
Bulletin Numbers
MPAS, MPMA
Strip Seal Replacement
Follow these steps to replace the strip seals.
ATTENTION: Handle strip seal material with care. The strip seal has sharp edges that can cause personal injury if mishandled.
1. Remove power from the linear stage, and lock out and tag the power source.
3. Position the carriage at the midpoint of stage travel.
4. Expose the center metal section of the carriage’s seal strip guide by
loosening the screws securing the end clamps and those at the carriage seal guide.
5. Thread the new strip seal, pointed end first, through the seal guides, the carriage, and then the end clamps.
6. Center and smooth the strip seal against the top cover and the side panel magnetic strips.
7. Using very light pressure, hold the seal guide against the strip seal, and then tighten the seal guide.
8. Tighten one end clamp, but do not tighten the clamp on the other end.
9. Move the carriage by hand through the complete range of travel and make
sure the strip seal seats smoothly against the cover and side panel magnet strips.
Pulling against the tightened end clamp will help to smooth the seal.
10. Once the seal lies flat and smooth against the top cover and side panel,
Strip Seal
Seal Guide
0.8 mm (0.03 in.) Shim
tighten the second end clamp.
11. With the outside edge of the end clamps as a guide, use tin snips to cut and remove excess strip seal material.
12. Position the carriage at the far end of travel.
13. Adjust the seal guide by inserting a 0.8 mm (0.03 in.) shim between the
seal guide and the strip seal.
14. Return the linear stage to service.
Allen-Bradley and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication MPAS-IN002A-EN-P - August 2011 814053