Important User Information

Because of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. In no event will Allen-Bradley be responsible or liable for indirect or consequential damage resulting from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited.
Throughout this publication, notes may be used to make you aware of safety considerations. The following annotations and their accompanying statements help you to identify a potential hazard, avoid a potential hazard, and recognize the consequences of a potential hazard:
WARNING
!
ATTENTION
!
IMPORTANT
Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.
Identifies information that is critical for successful application and understanding of the product.
Using This Manual
RAC6185 Industrial Flat Panel Monitor (6185-F) Features
Installation

Table of Contents

Preface
Who Should Use This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1
Purpose of This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1
Contents of This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-2
Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-3
Allen-Bradley Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-3
Chapter 1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Chapter 2
Chapter Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Before Unpacking the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Mounting Cutouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Installing your Monitor
in a Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Installing Your Monitor
in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Making Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Configuring the Video Setup
Performing Routine Maintenance
System Troubleshooting
Chapter 3
Chapter Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Setting the Monitor Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Checking and Changing
the Display Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Installing Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Adjusting Your Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Chapter 4
Chapter Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Replacing a Line Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Other Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Chapter 5
Chapter Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Self-Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Troubleshooting Solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Allen-Bradley Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
iii Publication 6185-UM006A-EN-P - July 2002
Table of Contents iv
Installing Rack Brackets on the RAC6185 Industrial Flat Panel Monitor (6185-F)
Touchscreen Serial Interface
Video Cables
Product Specifications
Appendix A
Installing Rack Adapter Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Appendix B
Setting Up the Touchscreen Interface. . . . . . . . . . . . . . . . . . . . . . . . . B-1
Appendix C
HD-15 Video Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Appendix D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Publication 6185-UM006A-EN-P - July 2002
Preface
Using This Manual
Read this preface to familiarize yourself with the rest of the manual. The preface covers the following topics:
who should use this manual
the purpose of the manual
the contents of the manual
conventions used in this manual
Allen-Bradley support

Who Should Use This Manual

Purpose of This Manual

Use this manual if you are responsible for installing, using or troubleshooting the 15.0” RAC6185 Industrial Flat Panel Monitor, model number 6185-F.
This manual is a user guide for the RAC6185 Industrial Flat Panel Monitor. It gives an overview of the system and describes procedures you use to:
install the 6185-F monitor in a panel or enclosure
make connections to 6185-F monitor
configure the 6185-F monitor’s video setup
troubleshoot the 6185-F monitor
1 Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-2

Contents of This Manual

Chapter Title Contents
Preface Describes the purpose, background and
scope of this manual. Also specifies the intended audience.
1 RAC6185 Industrial Flat
Panel Monitor (6185-F) Features
2 Installation Explains how to install the 6185-F monitors
3 Configuring the Video Setup Explains how to setup and configure 6185-F
Describes the features and capabilities of the 6185-F monitors.
in a panel or enclosure. Also how to connect power and external video sources.
monitors.
4 Performing Routine
Maintenance
5 System Troubleshooting Explains how to interpret and correct
Appendix A Installing Rack Brackets on
the RAC6185 Industrial Flat Panel Monitor (6185-F)
Appendix B Touchscreen Serial Interface Describes setting up and enabling the
Appendix C Video Cables Describes the HD-15 connector cable you
Appendix D Product Specifications Specifications for the 6185-F monitors.
Describes cleaning and other maintenance.
problems with the 6185-F monitors.
Explains how to install optional rack adapters on the 6185-F monitors for installation in a rack cabinet.
touchscreen for 6185-F monitors equipped with a touchscreen interface.
use to connect your monitor to the host computer.
Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-3

Manual Conventions

Allen-Bradley Support

The following conventions are used throughout this manual:
Bulleted lists such as this one provide information, not procedural steps.
Numbered lists provide sequential steps or hierarchical information.
Allen-Bradley offers support services worldwide, with over 75 Sales/Support Offices, 512 authorized Distributors and 260 authorized Systems Integrators located throughout the United States alone, plus Allen-Bradley representatives in every major country in the world.

Local Product Support

Contact your local Allen-Bradley representative for:
sales and order support
product technical training
warranty support
support service agreements

Technical Product Assistance

Before you contact Rockwell Automation for technical assistance, we suggest you please review the troubleshooting information contained in this publication first.
If the problem persists, call your local Rockwell Automation representative or contact Rockwell Automation in one of the following ways:
Phone United
States/Canada
Outside United States/Canada
Internet
1.440.646.5800
You can access the phone number for your country via the Internet:
1. Go to http://www.ab.com
2. Click on Product Support (http:// support.automation.rockwell.com)
3. Under Support Centers, click on Contact
Information
1. Go to http://www.ab.com
2. Click on Product Support (http:// support.automation.rockwell.com)
Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-4
Publication 6185-UM006A-EN-P - July 2002
Chapter
RAC6185 Industrial Flat Panel Monitor (6185-F) Features
1

Description

Package Contents

The RAC6185 Industrial Flat Panel Monitor (6185-F) offers the following:
NEMA Types 1/12/4X (indoor use only)
(IP65/IP53 equivalent) front panel
One-button automatic screen setup
Front panel keypad with lockout feature
90-254 VAC Power Supply
Plug and Play and Energy Star compatible
Thin enclosure (<2.5in [63mm])
Bright (250 nits) 16.7M color (24-bit) Active Matrix TFT display
Video formats supported from 640x480 to 1024x768
Fast response time (<25 msec)
Wide viewing angle
Optional resistive antiglare touchscreen
Optional rack mount adapter brackets
The shipping cartons contain the following items:
Monitor
CD containing ScreenSet Monitor Setup Utility, drivers and supporting
documentation
Package of mounting hardware (#10-32 self-locking nuts for panel
mounting)
Rack Mount Adapter Brackets (EIA19-8U) if you specified a
rack-mountable unit
AC power cord
Video cable
RS-232 serial extension cable (monitors with touchscreen option only)
Quick Start installation guide
1 Publication 6185-UM006A-EN-P - July 2002
1-2 RAC6185 Industrial Flat Panel Monitor (6185-F) Features
6185 - F A C A A A Z
1 2345678

Part Numbers

The part number for your particular unit consists of the monitor bulletin number (6185) followed by a seven-digit code indicating the display size and options on your unit.
EXAMPLE
Following are explanations of the part numbers for the various models of monitors:
Table 1.A Catalog Number Explanation for 6185-F Monitors
Position Option
2 Monitor Size F 15.0” Panel Mount
3 Front Panel Type
4
Touchscreen/Display Shield
Option
Letter
A Aluminum
B Stainless Steel
C Resistive Antiglare Touchscreen
K
W Antiglare Tempered Glass
Category Description
Resistive Antiglare Nickel-Gold Touchscreen
Z Polycarbonate Screen
5 Power Input A
6 External Video Cable A 6 ft (1.8m) HD15-HD15 Cable
7
8 Accessories
Touchscreen Serial Cable
120/240VAC Power Supply with 6 ft (1.8m) USA Power Cord
A 6 ft (1.8m) DE9-DE9 Cable
Z None (non-touchscreen only)
Rack Mount Adapter Brackets
R
(EIA19-8U)
Z None
Publication 6185-UM006A-EN-P - July 2002
Installation
Chapter
2

Chapter Objective

Before Unpacking the Monitor

This chapter describes installation of the RAC6185 Industrial Flat Panel Monitor (6185-F) including:
how to install the 6185-F monitors in a panel using mounting studs
how to install the 6185-F monitors in a rack
connecting the 6185-F monitors:
to a host computer video source
to a host computer serial port for touchscreen
to AC power
Before unpacking a new monitor, inspect the shipping carton for damage. If damage is visible, immediately contact the shipper and request assistance. Otherwise, proceed with unpacking.
TIP
Make sure you keep the original packaging for the monitor in case you need to return the monitor for repair.
1 Publication 6185-UM006A-EN-P - July 2002
2-2 Installation

Installation Guidelines

Follow these guidelines to help ensure that the monitor provides safe and reliable service.
Ensure that sufficient power is available from a single phase AC outlet
at the site.
ATTENTION
!
Ensure that sufficient space is available around air inlets and outlets to
provide the circulation necessary for cooling. Never allow air passages to become obstructed.
Ensure that the ambient air temperature will not exceed the specified
maximum temperature. You may need a user-supplied fan, heat exchanger, or air conditioner to meet this condition in some installations.
In order to maintain an electrically safe installation, RAC6185 Industrial Flat Panel Monitor (6185-F) must be connected to Earth ground when installed. Installing a 6185-F in a panel, enclosure or rack that is already connected to Earth ground will satisfy this requirement. Otherwise, connect the 6185-F to Earth ground using a 16 AWG or larger external wire.
The ground wire should have green insulation with a yellow stripe for easy identification.
TIP
IMPORTANT
Leave the monitor's enclosure or cover in place at all times during
operation. The cover affords protection against high voltages inside the monitor and inhibits radio-frequency emissions that might interfere with other equipment.
Remember that heat rises. The temperature at the top of an enclosure is often much higher than the rest of the enclosure if the air is not circulating.
This monitor is designed to operate at a range of extremes. However, it is not good design practice to continuously operate the monitor at the highest end of the specified temperature range.
While the product will operate at its highest specified temperature, the overall life span of any electronic device is shortened when it operates at its highest rated temperature.
Publication 6185-UM006A-EN-P - July 2002
Determine the minimum and maximum ambient humidity for the
monitor by consulting Appendix D, Product Specifications on page D-1. Ensure that the humidity of the ambient air will not exceed these limits (See Figure 2.1). In very dry environments, static charges build up very readily. Proper grounding of the equipment through the AC power cord can help reduce the likelihood of static discharges, which may cause shocks and damage electronic components
Figure 2.1 6185-F Operating and Storage Temperature and Humidity
Installation 2-3
Relative Humidity (%RH)
90
80
60
40
20
Operating Range
Storage Range
20
Temperature (°C)
(40°C, 90%)
(50°C, 50.4%)
(60°C, 27.7%)
40 60
Publication 6185-UM006A-EN-P - July 2002
2-4 Installation
]

Mounting Dimensions

302.16
[11.896]
The following figures show the mounting dimensions for the RAC6185 Industrial Flat Panel Monitor (6185-F).
All measurements are in mm[inches].
395.83
[15.584]
354.81
[13.969]
302.16
[11.896
58.67
61.93
[2.310]
[2.438]
438.15
[17.250]
Publication 6185-UM006A-EN-P - July 2002
Installation 2-5

Mounting Cutouts

20.574 [0.81]
29.718 [1.17]
16 x 7.112
[0.28]
101.600 [4.00]
177.800 [7.00]
279.400 [11.00]
The following figures provide the dimensions for making the panel or enclosure cutout for the RAC6185 Industrial Flat Panel Monitor (6185-F).
All measurements are in mm[inches].
401.574 [15.81]
381.000 [15.00]
127.000 [5.00]
254.000 [10.00]
8.128 [0.32]
309.118 [12.17]
12.700 [0.50]
406.400 [16.00]
322.580 [12.70]
Publication 6185-UM006A-EN-P - July 2002
2-6 Installation

Installing your Monitor in a Panel

Panel mount monitors are designed to provide protection against water and dust to NEMA Types 1/12/4X (indoor use only) (IP65/IP53 equivalent) standards.
Slides or shelves are not required because the panel mount monitor is designed to be supported by the panel in which it is installed.

Tools Needed for Panel Mount Installation

In addition to the tools required to make the panel cutout, you will need the following tools:
3/8 in deep well socket
1/4 in drive extension - 6" or longer
1/4 in drive ratchet or 1/4" drive torque ratchet

Panel Mounting Guidelines

Observe the following precautions when installing the unit in a panel:
Confirm that there is adequate space behind the panel.
– Allow at least 1.0 in (26mm) on the sides and bottom and 2.0 in
(51mm) on the top ventilation.
– A cabinet with a minimum depth of 2.9 in (74mm) is sufficient.
Take precautions so that metal cuttings do not enter any components
that are already installed in the panel.
Supporting panels should be at least 14 gauge to ensure proper sealing
against water and dust and to provide proper support. The mounting hardware supplied accommodates panels up to 0.25 in (6.35 mm) thick.
IMPORTANT
ATTENTION
Supporting panels must be cut and drilled to specifications before installation.
Failure to follow these warnings may result in personal injury or damage to the panel components.
!
Publication 6185-UM006A-EN-P - July 2002