Because of the variety of uses for the products described in this publication,
those responsible for the application and use of these products must satisfy
themselves that all necessary steps have been taken to assure that each
application and use meets all performance and safety requirements, including
any applicable laws, regulations, codes and standards. In no event will
Allen-Bradley be responsible or liable for indirect or consequential damage
resulting from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples shown in this
publication are intended solely for purposes of example. Since there are many
variables and requirements associated with any particular installation,
Allen-Bradley does not assume responsibility or liability (to include intellectual
property liability) for actual use based upon the examples shown in this
publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley
office), describes some important differences between solid-state equipment
and electromechanical devices that should be taken into consideration when
applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or part,
without written permission of Rockwell Automation, is prohibited.
Throughout this publication, notes may be used to make you aware of safety
considerations. The following annotations and their accompanying statements
help you to identify a potential hazard, avoid a potential hazard, and recognize
the consequences of a potential hazard:
WARNING
!
ATTENTION
!
IMPORTANT
Identifies information about practices or
circumstances that can cause an explosion in a
hazardous environment, which may lead to personal
injury or death, property damage, or economic loss.
Identifies information about practices or
circumstances that can lead to personal injury or
death, property damage, or economic loss.
Identifies information that is critical for successful
application and understanding of the product.
Using This Manual
RAC6185 Industrial Flat Panel
Monitor (6185-F) Features
Installation
Table of Contents
Preface
Who Should Use This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1
Read this preface to familiarize yourself with the rest of the manual. The
preface covers the following topics:
• who should use this manual
• the purpose of the manual
• the contents of the manual
• conventions used in this manual
• Allen-Bradley support
Who Should Use This
Manual
Purpose of This Manual
Use this manual if you are responsible for installing, using or troubleshooting
the 15.0” RAC6185 Industrial Flat Panel Monitor, model number 6185-F.
This manual is a user guide for the RAC6185 Industrial Flat Panel Monitor. It
gives an overview of the system and describes procedures you use to:
• install the 6185-F monitor in a panel or enclosure
• make connections to 6185-F monitor
• configure the 6185-F monitor’s video setup
• troubleshoot the 6185-F monitor
1Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-2
Contents of This Manual
ChapterTitleContents
PrefaceDescribes the purpose, background and
scope of this manual. Also specifies the
intended audience.
1RAC6185 Industrial Flat
Panel Monitor (6185-F)
Features
2InstallationExplains how to install the 6185-F monitors
3Configuring the Video Setup Explains how to setup and configure 6185-F
Describes the features and capabilities of
the 6185-F monitors.
in a panel or enclosure. Also how to
connect power and external video sources.
monitors.
4Performing Routine
Maintenance
5System TroubleshootingExplains how to interpret and correct
Appendix AInstalling Rack Brackets on
the RAC6185 Industrial Flat
Panel Monitor (6185-F)
Appendix BTouchscreen Serial Interface Describes setting up and enabling the
Appendix CVideo CablesDescribes the HD-15 connector cable you
Appendix DProduct SpecificationsSpecifications for the 6185-F monitors.
Describes cleaning and other maintenance.
problems with the 6185-F monitors.
Explains how to install optional rack
adapters on the 6185-F monitors for
installation in a rack cabinet.
touchscreen for 6185-F monitors equipped
with a touchscreen interface.
use to connect your monitor to the host
computer.
Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-3
Manual Conventions
Allen-Bradley Support
The following conventions are used throughout this manual:
• Bulleted lists such as this one provide information, not procedural steps.
• Numbered lists provide sequential steps or hierarchical information.
Allen-Bradley offers support services worldwide, with over 75 Sales/Support
Offices, 512 authorized Distributors and 260 authorized Systems Integrators
located throughout the United States alone, plus Allen-Bradley representatives
in every major country in the world.
Local Product Support
Contact your local Allen-Bradley representative for:
• sales and order support
• product technical training
• warranty support
• support service agreements
Technical Product Assistance
Before you contact Rockwell Automation for technical assistance, we suggest
you please review the troubleshooting information contained in this
publication first.
If the problem persists, call your local Rockwell Automation representative or
contact Rockwell Automation in one of the following ways:
PhoneUnited
States/Canada
Outside United
States/Canada
Internet
⇒
1.440.646.5800
You can access the phone number for your
country via the Internet:
1. Go to http://www.ab.com
2. Click on Product Support (http://
support.automation.rockwell.com)
3. Under Support Centers, click on Contact
Information
1. Go to http://www.ab.com
2. Click on Product Support (http://
support.automation.rockwell.com)
Publication 6185-UM006A-EN-P - July 2002
Using This Manual P-4
Publication 6185-UM006A-EN-P - July 2002
Chapter
RAC6185 Industrial Flat Panel Monitor
(6185-F) Features
1
Description
Package Contents
The RAC6185 Industrial Flat Panel Monitor (6185-F) offers the following:
• NEMA Types 1/12/4X (indoor use only)
(IP65/IP53 equivalent) front panel
• One-button automatic screen setup
• Front panel keypad with lockout feature
• 90-254 VAC Power Supply
• Plug and Play and Energy Star compatible
• Thin enclosure (<2.5in [63mm])
• Bright (250 nits) 16.7M color (24-bit) Active Matrix TFT display
• Video formats supported from 640x480 to 1024x768
• Fast response time (<25 msec)
• Wide viewing angle
• Optional resistive antiglare touchscreen
• Optional rack mount adapter brackets
The shipping cartons contain the following items:
• Monitor
• CD containing ScreenSet Monitor Setup Utility, drivers and supporting
documentation
• Package of mounting hardware (#10-32 self-locking nuts for panel
mounting)
• Rack Mount Adapter Brackets (EIA19-8U) if you specified a
rack-mountable unit
• AC power cord
• Video cable
• RS-232 serial extension cable (monitors with touchscreen option only)
• Quick Start installation guide
1Publication 6185-UM006A-EN-P - July 2002
1-2 RAC6185 Industrial Flat Panel Monitor (6185-F) Features
6185-FACAAAZ
12345678
Part Numbers
The part number for your particular unit consists of the monitor bulletin
number (6185) followed by a seven-digit code indicating the display size and
options on your unit.
EXAMPLE
Following are explanations of the part numbers for the various models of
monitors:
Table 1.A Catalog Number Explanation for 6185-F Monitors
PositionOption
2Monitor SizeF15.0” Panel Mount
3Front Panel Type
4
Touchscreen/Display
Shield
Option
Letter
AAluminum
BStainless Steel
CResistive Antiglare Touchscreen
K
WAntiglare Tempered Glass
Category Description
Resistive Antiglare Nickel-Gold
Touchscreen
ZPolycarbonate Screen
5Power InputA
6External Video CableA6 ft (1.8m) HD15-HD15 Cable
7
8Accessories
Touchscreen Serial
Cable
120/240VAC Power Supply with
6 ft (1.8m) USA Power Cord
A6 ft (1.8m) DE9-DE9 Cable
ZNone (non-touchscreen only)
Rack Mount Adapter Brackets
R
(EIA19-8U)
ZNone
Publication 6185-UM006A-EN-P - July 2002
Installation
Chapter
2
Chapter Objective
Before Unpacking the
Monitor
This chapter describes installation of the RAC6185 Industrial Flat Panel
Monitor (6185-F) including:
• how to install the 6185-F monitors in a panel using mounting studs
• how to install the 6185-F monitors in a rack
• connecting the 6185-F monitors:
– to a host computer video source
– to a host computer serial port for touchscreen
– to AC power
Before unpacking a new monitor, inspect the shipping carton for damage. If
damage is visible, immediately contact the shipper and request assistance.
Otherwise, proceed with unpacking.
TIP
Make sure you keep the original packaging for the monitor
in case you need to return the monitor for repair.
1Publication 6185-UM006A-EN-P - July 2002
2-2 Installation
Installation Guidelines
Follow these guidelines to help ensure that the monitor provides safe and
reliable service.
• Ensure that sufficient power is available from a single phase AC outlet
at the site.
ATTENTION
!
• Ensure that sufficient space is available around air inlets and outlets to
provide the circulation necessary for cooling. Never allow air passages to
become obstructed.
• Ensure that the ambient air temperature will not exceed the specified
maximum temperature. You may need a user-supplied fan, heat
exchanger, or air conditioner to meet this condition in some
installations.
In order to maintain an electrically safe installation,
RAC6185 Industrial Flat Panel Monitor (6185-F) must be
connected to Earth ground when installed. Installing a
6185-F in a panel, enclosure or rack that is already
connected to Earth ground will satisfy this requirement.
Otherwise, connect the 6185-F to Earth ground using a 16
AWG or larger external wire.
The ground wire should have green insulation with a yellow
stripe for easy identification.
TIP
IMPORTANT
• Leave the monitor's enclosure or cover in place at all times during
operation. The cover affords protection against high voltages inside the
monitor and inhibits radio-frequency emissions that might interfere with
other equipment.
Remember that heat rises. The temperature at the top of
an enclosure is often much higher than the rest of the
enclosure if the air is not circulating.
This monitor is designed to operate at a range of extremes.
However, it is not good design practice to continuously
operate the monitor at the highest end of the specified
temperature range.
While the product will operate at its highest specified
temperature, the overall life span of any electronic device is
shortened when it operates at its highest rated temperature.
Publication 6185-UM006A-EN-P - July 2002
• Determine the minimum and maximum ambient humidity for the
monitor by consulting Appendix D, Product Specifications on
page D-1. Ensure that the humidity of the ambient air will not exceed
these limits (See Figure 2.1). In very dry environments, static charges
build up very readily. Proper grounding of the equipment through the
AC power cord can help reduce the likelihood of static discharges,
which may cause shocks and damage electronic components
Figure 2.1 6185-F Operating and Storage Temperature and Humidity
Installation 2-3
Relative Humidity (%RH)
90
80
60
40
20
Operating Range
Storage Range
20
Temperature (°C)
(40°C, 90%)
(50°C, 50.4%)
(60°C, 27.7%)
4060
Publication 6185-UM006A-EN-P - July 2002
2-4 Installation
]
Mounting Dimensions
302.16
[11.896]
The following figures show the mounting dimensions for the RAC6185
Industrial Flat Panel Monitor (6185-F).
All measurements are in mm[inches].
395.83
[15.584]
354.81
[13.969]
302.16
[11.896
58.67
61.93
[2.310]
[2.438]
438.15
[17.250]
Publication 6185-UM006A-EN-P - July 2002
Installation 2-5
Mounting Cutouts
20.574
[0.81]
29.718
[1.17]
16 x 7.112
[0.28]
101.600
[4.00]
177.800
[7.00]
279.400
[11.00]
The following figures provide the dimensions for making the panel or
enclosure cutout for the RAC6185 Industrial Flat Panel Monitor (6185-F).
All measurements are in mm[inches].
401.574
[15.81]
381.000
[15.00]
127.000
[5.00]
254.000
[10.00]
8.128
[0.32]
309.118
[12.17]
12.700
[0.50]
406.400
[16.00]
322.580
[12.70]
Publication 6185-UM006A-EN-P - July 2002
2-6 Installation
Installing your Monitor
in a Panel
Panel mount monitors are designed to provide protection against water and
dust to NEMA Types 1/12/4X (indoor use only) (IP65/IP53 equivalent)
standards.
Slides or shelves are not required because the panel mount monitor is designed
to be supported by the panel in which it is installed.
Tools Needed for Panel Mount Installation
In addition to the tools required to make the panel cutout, you will need the
following tools:
• 3/8 in deep well socket
• 1/4 in drive extension - 6" or longer
• 1/4 in drive ratchet or 1/4" drive torque ratchet
Panel Mounting Guidelines
Observe the following precautions when installing the unit in a panel:
• Confirm that there is adequate space behind the panel.
– Allow at least 1.0 in (26mm) on the sides and bottom and 2.0 in
(51mm) on the top ventilation.
– A cabinet with a minimum depth of 2.9 in (74mm) is sufficient.
• Take precautions so that metal cuttings do not enter any components
that are already installed in the panel.
• Supporting panels should be at least 14 gauge to ensure proper sealing
against water and dust and to provide proper support. The mounting
hardware supplied accommodates panels up to 0.25 in (6.35 mm) thick.
IMPORTANT
ATTENTION
Supporting panels must be cut and drilled to specifications
before installation.
Failure to follow these warnings may result in personal
injury or damage to the panel components.
!
Publication 6185-UM006A-EN-P - July 2002