109212 (Rev. B 2/15/03) © SPX Corporation
Model 15145/15225
Two-Stage, Direct Drive
Vacuum Pump
1.2 cfm
(at 60 Hz)
Manufactured under one or more of the following patents:
U.S.: 4,523,897; 4,631,006.
Other Patents Pending.
Because of ongoing product improvements, we reserve the right to change
design, materials, and specifications without notice.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Operating
M
anual
PART NO. DESCRIPTION
41184 Handle
48104 Gas Ballast Valve
13191 Exhaust Plug
15135 Shell and Sight Glass Assembly (no drain)
41186 Base and Foot Assembly
REPLACEMENT PARTS LIST
%
SPX Corporation
655 Eisenhower Drive
Owatonna, MN 55060-0995 USA
Technical Services: 1-800-822-5561
Fax: 1-800-822-7805
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Web Site: www.robinair. com
Call our toll-free
Technical Support Line
1-800-822-5561
in the continental U.S. or Canada
or visit our web site
www.robinair.com
In all other locations, contact your local distributor. To help us
serve you better, please be prepared to provide the model
number, serial number, and date of purchase.
To validate your warranty, you must complete the warranty card
attached to your unit and return it within ten days from date of
purchase.

1 6
For use on A/C-R systems using CFCs, HCFCs, and
HFCs in conjunction with mineral oil, ester oil,
alkylbenzene oil and PAG oil as lubricants. Not for use
with ammonia or lithium bromide systems. Not for use
with flammable refrigerants.
OUT OF WARRANTY
Any Robinair high vacuum pump which is beyond the one-year warranty period
and fails to operate properly should be returned to the distributor with a full written
explanation of the problem, or you may return it yourself to the factory. Go to
Robinair.com or call 1-800-822-5561 for instructions on returning a pump.
Prior to returning an out-of-warranty pump, review all maintenance procedures to
avoid an unnecessary return. Note that contaminated oil or an incorrect oil level
will adversely affect pump performance. These conditions should be checked before
requesting service. Replacement parts are available if you desire to repair your own
pump. However, this should be considered only in out-of-warranty situations.
SPECIFICATIONS
Model 15145 15225
Number of Stages 22
Free Air Displacement 1.2 cfm* 1.0 cfm
Factory Micron Rating 50 50
Oil Capacity 5 oz. 5 oz.
148 ml 148 ml
Weight 10 lbs. 10 lbs.
4.54 kg 4.54 kg
Width 41/2"4
1
/2"
11.4 cm 11.4 cm
Length 913/16"9
13
/16"
25 cm 25 cm
Height 81/2"8
1
/2"
21.6 cm 21.6 cm
Intake Fitting
1
/4" MFL
1
/4" MFL
Motor Size
1
/8 hp
1
/8 hp
Capacitor Capacitor
Start Start
Voltage 100V 250V
50/60 Hz 50 Hz
Operating 185oF 185oF
Temperature 85oC85
o
C
*1.2 cfm at 60 Hz
1 cfm at 50 Hz
PARTS IDENTIFICATION
BLACK EXHAUST PLUG
(NOTE VENT HOLE)
RED SHIPPING PLUG
(REMOVE AND DISCARD)
GAS
BALLAST
VALVE
INLET
CAP
INLET
CONNECTION
SIGHT
GLASS
OIL LEVEL