Robertshaw BP Series User Manual

An ISO 9001 – 2000 Certified Company
Product Description
Robertshaw bypass non-electric zone dampers are Simply the Right Choice™ to maintain proper airflow and static pressure throughout the HVAC system. A bypass system should incorporate bypass dampers and a static pressure control device. We offer non-electric barometric pressure dampers that are self-regulating and field adjustable. They maintain proper static pressure in the system without requiring sensors or wiring. Robertshaw bypass dampers are compatible with forced air and constant volume zone systems requiring bypass air to maintain proper static pressure.
Our bypass dampers can be mounted vertically or horizontally due to unique static pressure with the weight on either side for installation and adjustment convenience. They are available in two sizes and can be used with HVAC equipment with capacities of up to five tons of cooling. All shells are constructed of rolled galvanized steel with stiffening ribs to maintain rigidity. A single steel offset blade is attached to a one-piece steel shaft connected with nylon bearings for smooth operation.
Features and Benefits
Lightweight for easy installation.
Stiffening ribs maintain rigidity.
Nylon bushings eliminate blade slippage and provide smooth operation.
Positive sealed blade close-off.
No wiring is required.
Reversible design allows for right- or left-handed flow.
Vertical or horizontal mounting.
BYPASS ZONE DAMPERS
BP Series
When Zoning Should Be Used
Robertshaw Zone Control Systems are compatible with forced air heating and cooling systems, and they are ideal for homes and building that exceed 2,500 square feet. Zoning systems help overcome many of the heating and cooling problems associated with spacious living and working area, as well as contemporary architectural features. You should consider zoning if your project is a multiple-level home or building, a rambling structure like ranch-style housing or schools, and has:
– Large glass windows susceptible to sunlight that varies
internal temperatures at different times of the day.
– Wings or additions extending from the main area.
– Vaulted ceilings, skylights, atriums or solariums.
– Finished attic, basement or room over the garage.
– Concrete slab flooring.
191 E. North Avenue Carol Stream Illinois 60188 USA Customer Service Telephone 1.800.304.6563 Customer Service Facsimile 1.800.426.0804 HVACCustomerService@invensyscontrols.com
www.RobertshawTstats.com www.invensyscontrols.com ©2008 Invensys Controls
For Technical Service Telephone 1.800.445.8299 Facsimile 1.630.260.7243 technicalservice@invensyscontrols.com
3505 Laird Road Unit #14 Mississauga Ontario L5L 5Y7 Canada Customer Service Telephone 1.800.387.7978 Customer Service Facsimile 1.905.828.1265 CanadianCustomerService@invensyscontrols.com 10/08 – 150-1578E
Specifications
Item BP Bypass Damper Ambient ratings 0˚F to 120˚F (-17˚C to 49˚C) Dimensions Round: 10”, 12”, 14”, 16”
(25.4cm, 30.5cm, 35.6cm, 40.6cm) Length: Diameter +3/4” wide
26-gauge galvanized steel
Weight 4.9 lb. to 6.0 lb.
(2.2 kg to 2.7 kg) Shell 26-gauge galvanized steel Blade 18-gauge galvanized steel Axle 3/8” diameter steel shaft Bearings Nylon
Robertshaw Panels
Classic panel: up to 3 zones Deluxe panel: up to 7 zones Premier panel: up to 19 zones
Robertshaw Dampers
Rectangular motorized zone dampers Round motorized zone dampers Bypass non-electric zone dampers
Robertshaw Thermostats
Programmable thermostats Digital non-programmable thermostats Mechanical thermostats
Robertshaw®Zone Control Systems
Ordering Information
Order number Ex. BP-10 Type BP (Bypass Damper) Size 10 (10”, 12”, 14”, 16”)
BYPASS ZONE DAMPERS
BP Series
Invensys®, Robertshaw®, SlimZone
®
and Simply the Right Choice™ are trademarks of Invensys plc., its subsidiaries and/or affiliated companies. All other brands mentioned in this document may be the trademarks of their respective owners.