Quick Start Installation Manual
Installation DOs and DON’Ts
DO
Shut off all power to system before installing.
Read entire manual before installing.
Make sure that all wiring conforms to
national and local codes.
DO NOT
Install on voltages greater than 30 VAC.
Short jumper across terminals on the gas
valve or at the system control.
Connect ground to any terminal in
this unit.
Install on outside walls or in direct sunlight.
Select location for installation.
Open the case with a screwdriver. Place in slot and gently pry forward at all four locations.
Mark mounting hole locations on wall.
Drill 3/16” holes at marked locations on wall. Insert plastic anchors into holes.
Align unit base over plastic anchors embedded in wall and secure with the screws provided.
Connect wiring between unit and furnace. For Model 9801i (1H/1C furnace applications).
Remove 1/4” of insulation from end of each wire
DELUXE PROGRAMMABLE THERMOSTATS
1
1-1/2"
1"
Cut
out
opening
a
b
2
3
4
Drill 3/16 holes
2
1/4"
5
6
H O B G
4
Thermostat
9801i
C R Y1 E/W1
1
3
TERMINAL DESIGNATIONS
C - 24VAC Common R - 24VAC Y1 - 1st stage cooling E/W1 - 1st stage heating O - Not used B - Not used G - Fan H - Humidification
Mark mounting hole locations on wall using unit base as template.
a
b
Press anchors into holes until flush.
C
Equipment Wiring
R
Terminals
Y
Please refer to furnace
W
installation manual for
G
C
Humidifier
H
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
proper terminations
B
O
NOTE: For 9801i single stage heat
pump applications, place a jumper between the E/W1 and Y1 terminals.
7
Connect wiring between unit and furnace. For Model 9815i (2H/2C furnace applications).
Replace cover on thermostat. To replace cover, line up top and bottom edges and push straight in. DO NOT pivot on upper case clips. Turn on power to unit and proceed with programming per instructions on the display or in the users manual.
Connect wiring between unit and heat pump. For Model 9820i (2H/2C heat pump applications).
To set your name and phone number into the thermostat press MENU, select INSTALLER SETTINGS, and CONTACT INFORMATION. The screen at the bottom left should appear.
To enter your name press EDIT. Use the UP or DOWN button to scroll through the characters. (DOWN gets you to the letters faster.) After each letter press NEXT.
When you are done entering your name, press ACCEPT.
Connect wiring between the thermostat and the indoor sensor (9020i) and the outdoor sensor (9025i), if used. Use twisted pair wiring (22AWG minimum) with a maximum length of 300 feet (or 100m).
Now enter your phone number. Use the UP and DOWN arrow to select the first number. Press NEXT. When you have completed entering your phone number, press ACCEPT.
The screen will return to the INSTALLER SETTINGS. Finish setting the thermostat for the application.
Y1
R
C
E/W1
H O B G
Thermostat
C - 24VAC Common R - 24VAC Y1 - 1st stage cooling E/W1 - 1st stage heating W2 - 2nd stage heating Y2 - 2nd stage cooling L - Not used O - Not used B - Not used G - Fan H - Humidification D - Not used
TERMINAL DESIGNATIONS
W2
D
Y2
C
C
H
R
Y1
W1
W2
Y2
G
B
L
O
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
9815i
Humidifier
Equipment Wiring Terminals Please refer to furnace installation manual for proper terminations.
Set Your Name Set Your Phone Number
Controls Americas 515 South Promenade Avenue Corona CA 92879-1736 United States of America Made in Mexico Patents Pending www.about-i-series.com
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys Climate Controls or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Climate Controls 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center
Thermostat
Jumper
C R Y1 E/W1
H O B G
Humidifier
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
9801i
C
H
TERMINAL DESIGNATIONS
C - 24VAC Common R - 24VAC Y1 - 1st stage cooling E/W1- 1st stage heating O - Cool active reversing valve B - Heat active reversing valve G - Fan H - Humidification
C
Equipment Wiring
R
Terminals
Y
Please refer to heat
G
pump installation manual for proper
B
terminations
O
8
9
10
Thermostat
If terminal E is not supplied, add jumper across E/W1 and W2 on the thermostat.
H O B G
Humidifier
Note: To avoid electrical problems, use the system transformer for both the thermostat and humidifier.
C R Y1 E/W1
D W2
Y2
L
9820i
C
H
TERMINAL DESIGNATIONS
C - 24VAC Common R - 24VAC Y1 - 1st stage heating/cooling E/W1 - Emergency heat strip W2 - 2nd stage heating Y2 - 2nd stage cooling L - System fault indicator O - Cool active reversing valve B - Heat active reversing valve G - Fan H - Humidification D - Not used
C
R
Equipment Wiring
Y1
Terminals
E
Please refer to heat
W2
pump installation
Y2
manual for proper
L
terminations.
G
B
O
11
1
2
CONTACT INFORMATION
BACK
EDIT
CONTACT INFORMATION
AIR EXPERTS
ACCEPT
NEXT
13
CONTACT INFORMATION
AIR EXPERTS
1
ACCEPT
NEXT
CONTACT INFORMATION
AIR EXPERTS
1-800-445-8299
ACCEPT
NEXT
Loading...