Robertshaw 9701i2 Owner's Manual

Five Year Warranty
User's Manual
Menu Driven Display Fully Programmable Brighter / Adjustable Backlight Night Light Option Auto Changeover Automatic Daylight Saving Time 24 VAC with
Worry-Free Memory Storage English, Spanish or
French Display Option
110-1177
C9701i2
C9725
i
2
DELUXE PROGRAMMABLE THERMOSTATS
2
TABLE OF CONTENTS
Important Safety Information ..........................................................................................................................................................................................4
Know Your Thermostat’s Controls and Displays
Control Buttons........................................................................................................................................................................................................5
Displays..................................................................................................................................................................................................................6-7
Choose Heating/Cooling ..................................................................................................................................................................................................8
Override Current Settings (Hold)
Temporary ................................................................................................................................................................................................................9
Vacation ....................................................................................................................................................................................................................9
Auto Changeover ..................................................................................................................................................................................................10
Override Fan Operation ..................................................................................................................................................................................................11
Programming the Thermostat
Reset to EnergyStar
®
............................................................................................................................................................................................12
Events per Day ......................................................................................................................................................................................................12
Program ..................................................................................................................................................................................................................13
Sensor ....................................................................................................................................................................................................................13
Set Time and Day..............................................................................................................................................................................................................14
Comfort Settings
1st Stage Differential ............................................................................................................................................................................................15
2nd Stage Differential ..........................................................................................................................................................................................15
2nd Stage Delay ....................................................................................................................................................................................................15
Sensor ....................................................................................................................................................................................................................15
Deadband................................................................................................................................................................................................................16
Efficient Recovery ................................................................................................................................................................................................16
3
Customize the Display
Fahrenheit or Celsius............................................................................................................................................................................................17
Show Set Temperature ........................................................................................................................................................................................17
Choose a Language (English, French or Spanish) ..........................................................................................................................................17
Temperature Offset (Calibrate the Thermostat) ..............................................................................................................................................17
Resolution (Temperature Display)......................................................................................................................................................................17
Air Quality Service Reminders (Filter, UV Light, Humidifier Pad)..................................................................................................................18
Display Settings – Brightness and Contrast ....................................................................................................................................................18
System Settings
Equipment Setup....................................................................................................................................................................................................19
1st/2nd Stage Heating ..........................................................................................................................................................................................19
Compressor Type ..................................................................................................................................................................................................19
2nd Stage Fan ........................................................................................................................................................................................................19
1st/2nd Stage Cooling ..........................................................................................................................................................................................20
Short Cycle ............................................................................................................................................................................................................20
Residual Cool..........................................................................................................................................................................................................20
Balance Points ......................................................................................................................................................................................................20
Set Service Reminders ........................................................................................................................................................................................21
Set Temperature Limits ........................................................................................................................................................................................21
Auto Changeover ..................................................................................................................................................................................................22
Contact Information ..............................................................................................................................................................................................22
Reset to Defaults ..................................................................................................................................................................................................22
Security On/Off (Controls System Settings only) ............................................................................................................................................23
Preventing Thermostat Access
Allow Temperature Adjustment..........................................................................................................................................................................24
Security On/Off (Controls all thermostat functions) ........................................................................................................................................24
Tech Support ....................................................................................................................................................................................................................25
Frequently Asked Questions ....................................................................................................................................................................................26-30
Warranty ............................................................................................................................................................................................................................31
4
IMPORTANT SAFETY INFORMATION
WARNING:
• Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, or cleaning this thermostat.
• Read all of the information in this manual before programming this thermostat.
• This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC.
• All wiring must conform to local and national building and electrical codes and ordinances.
• Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
• Do not connect ground to any terminal in this unit.
• This thermostat is equipped with configurable automatic compressor protection to prevent potential damage due to short cycling or extended power outages. The short cycle protection provides up to a 5-minute delay between heating (heat pump only) or cooling cycles to prevent the compressor from being damaged.
• Do not switch system to cool if the temperature is below 50°F (10°C). This can damage the cooling system and may cause personal injury.
• Use this thermostat only as described in this manual.
About this guide: This User’s Guide deals with the basic display and programming features of this thermostat. It is not an exhaustive technical guide for every application and combination of heating/cooling equipment and controls that might be connected to the thermostat.
5
KNOW YOUR THERMOSTAT'S CONTROLS AND DISPLAYS page 1 of 3
NOTE: In many cases the installer made the initial setup of your thermostat. That was based on your preferences and the characteristics of your heating/cooling system. Our User’s Guide gives information allowing you to make basic modifications for your home environment at any time.
Become familiar with your thermostat's controls and displays by reviewing the information on the next three pages.
LEFT button: Used to access the heating/cooling menu, to move back to the previous screen, or to can­cel an operation.
LED System Status indica­tors turn on to show the active equipment.
RIGHT button. Used to select items from menus and to accept data input.
DOWN ( ) button. Used to decrease the displayed value or scroll down through the menus.
UP ( )button. Used to increase the displayed value or scroll up through the menus.
6
Animated fan icon – rotating
blade shows the fan is on.
KNOW YOUR THERMOSTAT'S CONTROLS AND DISPLAYS page 2 of 3
3 Typical Main Screen Views
Current setpoint
(Setpoint = desired temperature)
Animated system icon – flame indicates
heating mode. A snowflake indicates
cooling mode.
These 2 icons move when heating or
cooling are on.
A small A shows that Auto Changeover
is the selected mode.
A number 2 shows
that the 2nd stage
is active.
A small E shows that
Emergency Heat (heat pump only) is the selected mode.
Right button label
Left button label
This area of the display
shows the local, remote
and outdoor temperatures.
It also shows EER, Check
Heat Pump and Remote
Sensor Failure.
Measured temperature
Current date and time
9:15AM Monday Jun 20
68.9
°F
Outside 42
Mode
A
Set At 70
Menu
9:15AM Monday Jun 20
68.9
Outside 42
Mode
°F
Set At 70
Menu
E
9:15AM Monday Jun 20
68.9
Remote 73
Mode
°F
Set At 70
Menu
2
7
KNOW YOUR THERMOSTAT'S CONTROLS AND DISPLAYS page 3 of 3
3 Typical Menu Views
Menu title
Bar indicates position of
selected item relative to the
start and end of the menu.
Arrow shows there is
more to see. Use the
left button to view more of the menu.
Arrow shows there is
more to see. Use the
right button to view
more of the menu.
Up and down arrows show there are more
menu items.
Dotted line shows the
end of the menu list.
Item to select
Equipment Setup Menu
1st Stg Cool Yes
2nd Stg Cool No Short Cycle 5Min
-----------
Back
Select
Mon To Sun Program
HEAT COOL
Wake 6:00 AM 70 78
Morn 8:00 AM 62 85 Eve 5:00 PM 70 78 Night 10:00 PM 62 82
Exit
Select
Mon To Sun Program
FAN SNSR
Wake 6:00 AM Auto Lcl
Morn 8:00 AM Auto Lcl Eve 5:00 PM Auto Lcl Night 10:00 PM Auto Lcl
Back
Next
CHOOSE HEATING/COOLING
To choose a mode (of operation), select Mode.
There are five possible operating modes:
Off – The heating/cooling systems are turned off, and will not operate. Heat – The heating system is activated. The main screen displays the heat icon ( ). Cool – The cooling system is activated. The main screen displays the cool icon ( ). Auto Changeover – Either heating or cooling will be activated to maintain the temperature
setpoint. The main screen displays the letter A next to the or .
NOTE: Auto Changeover will be displayed only if activated in System Settings. Emer – Emergency heat is activated. (This choice is available only when 1st stage Heat is set
as Heat Pump.) The main screen displays a small letter E next to the .
Note: Emer will not automatically energize on the C9701i2. You will need to manually select it from the Current Mode menu. Note: Balance points are not an option when an outdoor sensor is installed with the C9701i2.
When should I select Emergency Heat?
If your heat pump is not adequately providing heat, you can bypass it by selecting Emergency (heat) until the heat pump can be serviced. In some installations, your thermostat may indicate a problem with the heat pump by displaying a message (on the main screen) underneath the temperature. You may also want to select Emergency (heat) when the outdoor temperature drops below freezing since the heat pump is very inefficient at low temperatures. See Balance Points (page 20) for other options.
8
9:15AM Monday Jun 20
°F
68.9
Outside 70
Mode
Menu
Current Mode
Off
Heat Cool
Cancel
Current Mode
Heat Cool
Auto Changeover
Cancel
Accept
Accept
OVERRIDE CURRENT SETTINGS page 1 of 2
NOTES: These directions are for both Heating and Cooling.
Hold does not appear in the Main Menu if Off is the selected mode. To access the Override Settings, select Menu on the main screen.
Hold – With this menu item you may override the current temperature setpoint and choose a new setpoint
to be held during the override period. This can be a few hours, or it can be a longer period. To start a Hold: On the Main Menu, scroll to Hold, and press Select. OR. . . While at the main screen,
press either the or button. In either case, the Hold Temperature screen appears.
Set the Hold Temperature by pressing the or button until the desired temperature is displayed. Select Next. The Select Override Type screen appears.
NOTE: The unlabeled arrow is the current room temperature. The arrow with a or is the programmed setpoint for that mode.
A Temporary override lasts up to 24 hours. A Vacation override lasts up to one year.
Temporary Hold – Select the time when the hold will end. Select Accept. The Main Menu will appear. Select Back. The main screen will show the hold temperature and time. When the hold expires, normal operation continues.
Vacation Hold – Select the number of days for the hold to last. Select Accept. The Main Menu will appear. Select Back. The main screen will show the hold temperature and time. Vacation hold ends at midnight on the last day.
NOTE: To cancel the hold at any time, select Resume.
9
Hold
Fan Schedule Time & Day
Back
Main Menu
Select
Hold Temperature
50 60 70 80 90
Cancel
Cool: 80
Select Override Type
Back
Next
Temporary
Vacation
Hold Temperature
Back
Returning Home
ON WEDNESDAY, 6/22/05
Back
Next
Until
12:20
TODAY
In
2
PM
Accept
Days
Accept
Set At 77 Until 12:20PM
68.9
Outside 92
Resume
Set At 77 Until Jun 22
68.9
Outside 42
Resume
°F
°F
AM
9:15
Menu
AM
9:15
Menu
OVERRIDE CURRENT SETTINGS page 2 of 2
Setting a hold when the operating mode is Auto Changeover. When the selected mode is Auto Changeover, setting a hold means that two setpoints (one for heat and one for cool) have to be
chosen. The distance between the heating and cooling setpoints cannot be smaller than the deadband. (For more information about deadband, see COMFORT SETTINGS on page 16.)
NOTE: There is a letter A next to the on the main screen. This shows that Auto Changeover is active. The settings are the same for Auto Changeover as they are for just Heat or Cool (see previous page), except both a heat and cool
hold temperature must be selected.
NOTE: The or above the arrows are the heat and cool setpoints respectively. The unlabeled arrow is the current room temperature.
Press the or button until the desired Heat temperature is displayed. Select Next. Press the or
button until the desired Cool temperature is displayed. Select Next. The Select Override Type screen
appears. Follow the Select Override Type steps from the previous page to complete the hold setting.
10
Hold Temperature
Heat: 65 Cool: 80
50 60 70 80 90
Cancel
Set At 77 Until 12:20PM
68.9
Outside 42
Resume
Next
°F
Menu
A
AM
9:15
OVERRIDE FAN OPERATION
NOTE: Choosing a fan mode (On, Auto or Intermittent) with the Fan Menu overrides the fan choices made when you use the Main Menu’s Schedule option. (See PROGRAMMING THE THERMOSTAT on page 12 and 13.)
Select Menu from the main screen. Select Fan from the Main Menu.
The first item on the Fan Menu is Fan Mode. Possible fan modes are:
On – In this mode the fan is constantly on until a different fan mode is chosen. Auto – The fan operates when either the heating system or cooling system require it. Intermittent – Use this fan mode to circulate the air in your home between heating or
cooling cycles. The fan operates similarly to Auto mode. When heating or cooling equipment is not active, the
fan circulates the air for Intermittent On (how long the fan will be on) and Intermittent Off (how long the fan will be off) times you set. These times are set from the Fan Menu by selecting the Intermittent On or Intermittent Off option and then using the or button to select the desired amount of time.
Program – In this fan mode, fan operation is determined by the programming done through the Program Menu. (For more information, see PROGRAMMING THE THERMOSTAT on page 12
and 13.) Select this mode if the fan operation was overriden and you would like it to resume the
settings made in the original program.
11
Main Menu
Hold
Fan
Schedule Time & Day
Back
Fan Mode Auto
Intermittent On 5Min Intermittent Off 20Min
Back
Select
Fan Menu
Select
PROGRAMMING THE THERMOSTAT page 1 of 2
From the main screen, select Menu.
From the Main Menu, select Schedule. Your schedule is based on the number of events you want each day. Each event includes a time of
day, heating and cooling setpoint, fan setting, and sensor setting. (Sensor setting only appears when a remote sensor is installed.) There can be two, four, or six events per day.
You can change how many events per day by selecting Events/Day. In the following programming example, the Schedule Menu shows the default of four events
per day.
12
About EnergyStar
®
Your thermostat has been preprogrammed with a schedule of setpoints recommended by EnergyStar (www.energystar.gov). This schedule is designed to lower your energy costs year-round.
If you changed the schedule and want to return to the EnergyStar schedule, you can do that at any time by selecting Menu, Schedule, Reset to EnergyStar.
EnergyStar®Event Setpoints
Winter Summer
(Heating) (Cooling) Morning 70°F (21°C) 78°F (25°C) Day 62°F (17°C) 85°F (29°C) Evening 70°F (21°C) 78°F (25°C) Night 62°F (17°C) 82°F (28°C)
Main Menu
Fan
Schedule
Time & Day Comfort Settings
Back
Select
Schedule Menu
Program
Events/Day 4
Reset to EnergyStar
Back
Select
PROGRAMMING THE THERMOSTAT page 2 of 2
From the main screen, select Menu, then Schedule, then Program. This will take you to the Select Program Days menu. The choices are: Mon to Sun – All days of the week will be set the same. Mon to Fri – Five weekdays can be set the same. Sat to Sun – Weekend days can be set differently from the weekdays.
Individual Days (you may select the actual individual days) – Each day can be set separately.
NOTE: If your programming does not cover all the days of the week, the EnergyStar
®
setpoints are used for the remainder of the days.
Even if you select one of the groups of days (e.g., Mon to Sun), you may still select individual days and program those differently.
Once you select the day or set of days: NOTE: In this example there are four events (Wake, Morn, Eve and Night) in a Monday to Sunday program. The previous page explained how to change the number of events. Selecting Next will change the highlighted selection.
Choose one event (Wake, for instance), and make changes to the four items in that row:
Time – Select a time. The thermostat allows for changes in 10-minute increments. Heat and Cool – Select temperature. Adjustments are in one-degree increments. Fan – Choose On, Auto, or Int (Intermittent). (See OVERRIDE FAN OPERATION on page 11.)
NOTE: You will see this message: Would You Like To Change Fan Mode To Program? If you select No, the setting you chose is shown but
not used. The setting in the Fan Mode Menu takes priority.
If a remote sensor is installed, SNSR will be the fifth item to program.
SNSR – In this column you select the temperature sensor(s) used to control the thermostat. Lcl selects the local sensor built-in to the thermostat, and is the default setting for this menu
item. Rmt selects the remote indoor sensor. This choice also disables the local sensor. Avg selects the average temperature of the local and remote sensors.
NOTE: Sensor selection made here overrides the sensor choice made with Comfort Settings. You may see this message: Do You Want
Sensor to Change to Program? If you select Yes , Sensor will change to Program in Comfort Settings (see page 16).
13
Select Program Days
Mon To Sun
Mon To Fri Sat To Sun Monday
Cancel
Mon To Sun Program
HEAT COOL
Wake 6:00 AM 70 78
Morn 8:00 AM 62 85 Eve 5:00 PM 70 78 Night 10:00 PM 62 82
Exit
Mon To Sun Program
FAN SNSR
Wake 6:00 AM Auto Lcl
Morn 8:00 AM Auto Lcl Eve 5:00 PM Auto Lcl Night 10:00 PM Auto Lcl
Back
Next
Select
Next
TIME & DAY
NOTE: The main screen time/day/date line flashes until time and date are set.
Select Time & Day from the Main Menu.
With the Time & Day Menu you can make these four settings:
Time – Set the Time by setting the hour and then the minutes. Date – Set the month, then the day, then the year. 12hr or 24hr – Select a clock type; either a 12-hour or 24-hour format. Auto DST – Choose whether you want the thermostat’s clock to adjust automatically for
D
aylight Saving Time.
No – Makes the Auto DST feature inactive. Standard (Apr - Oct) – The clock will be automatically set one hour ahead at 2:00 am on
the first Sunday in April, and set one hour back at 2:00 am on the last Sunday in October. Extended (Mar - Nov) – The clock will be automatically set one hour ahead at 2:00 am
on the second Sunday in March, and set one hour back at 2:00 am on the first Sunday in November. (The Extended option meets conditions of U.S. Federal Daylight Saving Time legislation that goes into effect in 2007.)
NOTE: When finished with these settings, check the main screen to see that the correct day and time are displayed.
14
Main Menu
Hold Fan Schedule
Time & Day
Back
Select
Time & Day Menu
Time 9:15AM
Date 6/6/05 12hr or 24hr 12hr Auto DST Standard...
Back
No
Standard (Apr-Oct)
Extended (Mar-Nov)
Select
Auto Adjust for DST?
Cancel
Accept
15
COMFORT SETTINGS page 1 of 2
NOTE: Every person has preferences about personal comfort. The following pages refer to a level of satisfaction with your home environment as it relates to the operation of the heating and cooling system.
Comfort Settings control equipment cycling (on/off periods), staging and sensors that may be connected to your thermostat.
Choose Comfort Settings, from the Main Menu. The four items available in this menu are explained below.
1st Stage Differential is the number of degrees away from the setpoint that the thermostat allows before it calls for the 1st stage equipment to be activated. As this setting is lowered, your system will cycle more frequently.
2nd Stage Differential is the number of degrees away from 1st stage activation that the thermostat allows before 2nd stage equipment is activated. (Temperature demand overrides the 2nd Stage Delay.) This feature is available only on the C9725i2 models.
2nd Stage Delay is a timed delay between 5 and 20 minutes. It is the maximum time 1st stage equipment tries to satisfy demand before the second stage equipment is activated. This feature is available only on the C9725i2 models.
Sensor appears only if a remote sensor is connected to the thermostat. If a remote sensor is connected, you can choose to have the temperature controlled by the thermostat’s built-in sensor (Local), by the remote sensor (Remote), or by an average between the two sensors (Average). You also can select Program, which means the sensor selection is controlled by the programmed schedule.
See the SNSR section in PROGRAMMING THE THERMOSTAT on page 13. Also, see Do I need an accessory sensor? in FREQUENTLY ASKED QUESTIONS for sensor choice and faulty sensor information.
Main Menu
Comfort Settings
User Preferences System Settings User Security
Back
Comfort Settings Menu
1st Stage Diff 1.0°F
2nd Stage Diff 2.0°F 2nd Stage Delay 20Min Sensor Local
Back
Select
Select
COMFORT SETTINGS page 2 of 2
Deadband is used only when the thermostat is set in the Auto Changeover mode. The deadband refers to a band or range between the heating and cooling setpoints that controls how often the thermostat switches from heating to cooling and vice versa.
The lower the deadband, the more often the thermostat will switch between heating and cooling, usually in the fall and spring.
(For more information, see What is deadband? in FREQUENTLY ASKED QUESTIONS on page 27.)
The Warning shown to the left appears alerting you that Deadband adjustments may affect Schedule data.
This means setpoints already entered into the program may be changed when the deadband is put into effect.
When (Energy) Efficient Recovery is turned on (Yes ), the thermostat attempts to reach the next setpoint at the exact time of the next event. If you have two stages, the thermostat will use only the first stage during this period. This is more efficient than waiting until the next event and then turning on both first and second stages.
(For more information, see What is Energy Efficient Recovery™ (EER™)? in FREQUENTLY ASKED
QUESTIONS on page 27.)
16
Comfort Settings Menu
Sensor Program
Deadband 2.5°F
Efficient Recovery No
-----------
Back
Select
Warning!
Adjusting Deadband
May Adjust
Schedule Data.
Continue?
No
Comfort Settings Menu
Sensor Program Deadband 2.5°F
Efficient Recovery Yes
-----------
Back
Select
Yes
CUSTOMIZE THE DISPLAY page 1 of 2
User Preferences provides you with more ways to customize the displayed information and maintain optimal comfort.
From the Main Menu, choose User Preferences.
ºF or ºC – Allows temperature to be displayed in either the Fahrenheit or Celsius scale.
Show Set Temp – Allows for the temperature setpoint to be displayed. (See the example at right.)
Language – You can choose to display thermostat information in English, French or Spanish.
Temp Offset – Allows for offsetting the factory calibration by ±3ºF or ±1.5ºC. Resolution – Personalize the way the main temperature is displayed. The main screen
temperature display can be in whole degrees, in half degrees, or in tenths of a degree.
17
Main Menu
Comfort Settings
User Preferences
System Settings User Security
Back
User Preference Menu
°F or °C °F
Show Set Temp Yes Language English Temp Offset 0.0°F
Back
User Preference Menu
Show Set Temp Yes Language English Temp Offset 0.0°F
Resolution Tenths°
Back
Select
Select
Select
9:15AM Monday Jun 20
°F
68.9
Outside 42
Mode
Set At 70
Menu
A
CUSTOMIZE THE DISPLAY page 2 of 2
Air Quality – Sets service reminders for parts of the heating/cooling system that need periodic attention.
Based on the intervals you set, these service reminders are displayed on the main screen when a part needs to be serviced:
Replace or Clean Filter UV Filter: Replace Bulb Replace or Clean Humidifier Pad
All service intervals can be set to OFF or for a period of 1-12 months. When the main screen reminder appears, you can select either of
these choices: Delay – This is a 24-hour delay. The reminder appears again in one day. Reset – This resets the service reminder. It will appear again at the end of the interval that’s been set.
Display Settings – Changes screen brightness and contrast control. Idle Brightness – Refers to backlight brightness. When turned ON, this feature can be used as
a night light.
Active Brightness – Refers to backlight brightness when any of the keys are being used. Contrast – Refers to screen clarity.
18
User Preference Menu
Temp Offset 0.0°F Resolution Tenths°
Air Quality
Display Setting
Back
Select
Replace Or Clean
Filter
Delay
Reset
SYSTEM SETTINGS page 1 of 5
NOTE: Only the installing contractor should set System Settings.
Choose System Settings from the Main Menu. The System Settings Menu gives nine more ways to get the most from the thermostat. The information below describes how these features enhance thermostat performance.
Equipment Setup – Make selections about the types of equipment used in your heating/cooling system.
First, choose what type of equipment is used for the 1st Stage Heat. Choices are: None, Furnace (e.g., gas forced air furnace), Strip (e.g., electric baseboard heating), or Heat Pump.
On C9725i2 models, choose 2nd Stage Heat. Choices are: None, Furnace, Strip, or Heat Pump.
If Heat Pump is chosen for the 1st Stage Heat and Furnace is chosen for the 2nd Stage Heat, two new menu items will appear on the Equipment Setup Menu; Comp. Type and 2nd Stage Fan.
The Comp. Type allows you to determine how 1st and 2nd stage heat work together.
Add-On – 1st stage heating compressor on the heat pump will be turned off when 2nd stage heating is activated. Standard – 1st stage heating compressor will continue to operate with the 2nd stage furnace for added heating.
The 2nd Stage Fan determines how the fan will operate.
Plenum – Allows the furnace to control the fan. ON – Allows the thermostat to control the fan.
19
Main Menu
Comfort Settings User Preferences
System Settings
User Security
Select
Back
System Settings Menu
Equipment Setup
Residual Cool 60Sec Balance Points Service Intervals
Back
Select
Equipment Setup Menu
1st Stg Heat Heat Pump 2nd Stg Heat Furnace
Comp. Type Standard
2nd Stage Fan Plenum
Back
Select
SYSTEM SETTINGS page 2 of 5
1st Stage Cool equipment – Select Yes or No. 2nd Stage Cool equipment can be selected for C9725i2 models only – Select Yes or No. Short Cycle – The minimum time between heating or cooling cycles intended to protect
your equipment. (See the WARNING below.) Turn it Off or set it from 1 to 5 minutes.
WARNING: Adjusting the Short Cycle protection may damage the cooling equipment. Check with the equipment
manufacturer’s recommended settings.
Residual Cool – For cooling system efficiency, this tells the fan to keep running for up to two minutes after the cooling system has shut down.
Balance Points – This choice only appears when the 1st stage is a heat pump. Low and High balance points are selected. The low balance point prevents the heat pump from being used when it is least efficient. The high balance point prevents the second stage heat (furnace or strip) from activating when the heat pump is most efficient.
Outdoor setpoint temperature ranges are:
Low Setpoint : -20ºF to 75ºF (-29ºC to 24ºC) High Setpoint : 0ºF to 75ºF (-18ºC to 24ºC)
(For more information, see What are balance points? in FREQUENTLY ASKED QUESTIONS on page 26.)
20
Equipment Setup Menu
1st Stg Cool Yes
2nd Stg Cool No Short Cycle 5Min
-----------
Back
Select
System Settings Menu
Equipment Setup
Residual Cool 60Sec
Balance Points Service Intervals
Back
Select