Quick Start Installation Manual
111-304C
Installation DOs and DON’Ts
DO
• Shut off all power to system before installing.
• Read entire manual before installing.
• Make sure that all wiring conforms to
national and local codes.
DO NOT
•
Install on voltages greater than 30 VAC.
• Short jumper across terminals on the gas
valve or at the system control.
• Connect ground to any terminal in
this unit.
• Install on outside walls or in direct sunlight.
Select location for installation.
To open battery door, slide it to the right.
Open the case with a coin by placing it
in the slot and gently prying forward at all
three locations.
Mark mounting hole locations on wall.
Drill 3/16” holes at marked locations on
wall. Insert plastic anchors into holes.
Align unit base over plastic anchors
embedded in wall and secure with the
screws provided.
Connect wiring between unit and
furnace. For Model 9700
i (1H/1C
gas/electric heating and cooling
applications).
DELUXE
Remove 1/4” of insulation
from end of each wire
2
1
3
PROGRAMMABLE
9700
i
THERMOSTAT
1
1-1/2"
1"
Cut
out
opening
2
a
b
3
4
Drill 3/16 holes
a
1/4"
5
6
Thermostat
Factory installed jumper
HP J1
FN
Y
W
Rc
Rh
O
B
G
9700i
TERMINAL DESIGNATIONS
Rh - 24VAC
Rc - 24VAC
W - 1st stage heating
O - Not used
B - Not used
G - Fan
Y - 1st stage cooling
Mark mounting hole
locations on wall using
unit base as template.
b
Press anchors into holes until flush.
Remove factory installed
jumper if two transformers
are used.
Equipment wiring
terminals.
G
Please refer to
Y
furnace installation
W
manual for
R
proper connections.
Connect wiring between unit and
heat pump. For 9700i (single stage
heat pump applications):
Wire as shown and move jumper J1
to the HP position (top two pins).
7
Connect wiring between the thermostat and the indoor sensor (9020i)
and the outdoor sensor (9025i), if
used. Use twisted pair wiring
(22AWG minimum) with a maximum
length of 300 feet (or 100m).
Proceed with programming per
instructions on the display or in the
user’s manual.
Replace cover on thermostat.
Set Your Name
To set your name and phone
number into the thermostat press
MENU, select INSTALLER
SETTINGS, and CONTACT
INFORMATION The screen at the
bottom left should appear.
To enter your name press EDIT.
Use the UP or DOWN button to
scroll through the characters.
(DOWN gets you to the letters
faster.) After each letter press NEXT.
When you are done entering your
name, press ACCEPT.
Insert 4 AA alkaline batteries. Make
sure to follow proper polarity.
Controls Americas
515 South Promenade Avenue
Corona, CA 92879-1736
United States of America
Made in Mexico
www.about-i-series.com
111-304C
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury,
DO NOT discard the old thermostat in the regular trash. Mercury
is harmful to humans and the environment. For this reason, do
not open, break, or crush the mercury cell. If mercury leaks from
a damaged cell, DO NOT touch or handle mercury with bare
hands. Use protective, non-absorbent gloves to place mercury
into a sealable container. Fill the container with sand or another
absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to
Invensys Climate Controls or a local recycling center for proper
disposal. If you have any questions, call Robertshaw technical
support at 1-800-445-8299.
Invensys Climate Controls
28C Leigh Fisher Blvd.
El Paso, TX 79906
Attn: Mercury Recycling Center
Set Your Phone Number
Now enter your phone number.
Use the UP and DOWN arrow to
select the first number. Press NEXT.
When you have completed entering
your phone number, press ACCEPT.
The screen will return to the
INSTALLER SETTINGS. Finish
setting the thermostat for the
application.
Thermostat
8
9
10
11
Factory installed jumper
HP J1
FN
Y
W
Rc
Rh
O
B
G
9700i
TERMINAL DESIGNATIONS
Rh - 24VAC
Rc - 24VAC
W - Not used
O - Reversing valve (cool)
B - Reversing valve (heat)
G - Fan
Y - 1st stage heating/cooling
Equipment wiring
terminals.
G
Please refer to
Y
heat pump installation
R
manual for
O
proper connections.
1
2
CONTACT INFORMATION
CONTACT INFORMATION
AIR EXPERTS
13
CONTACT INFORMATION
AIR EXPERTS
1
ACCEPT
NEXT
CONTACT INFORMATION
AIR EXPERTS
1-555-555-1212
ACCEPT
NEXT
BACK
EDIT
ACCEPT
NEXT