Robertshaw 9600 User Manual

1
Installation Guide
IMPORTANT SAFETY INFORMATION WARNING:
Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or programming this thermostat.
This is a 24V AC low voltage thermostat. Do not install on voltages higher than 30V AC.
All wiring must conform to local and national building and electrical codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
110-653C
5 - 2 Day Programmable 1 Heat / 1 Cool
W
A
R
R
A
N
T
Y
INTEGRATED COMFORT SOLUTIONS
DIGITAL PROGRAMMABLE THERMOSTAT
9600
User’s Manual
Quick Start Installation and Programming
®
ELECTRIC
E
GAS
G
110-653C
Features
• Four setpoints for weekday programming—two setpoints for weekend comfort.
•Two AA ENERGIZER brand batteries retain program memory even during power outages.
• Low battery indicator.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (4°C) to 90°F (32°C).
•Accuracy within ± 1 degree.
• Adjustable temperature differential: 1-3 degrees.
•Maintains summer and winter programming.
• Low temperature freeze protection. While in heat mode, thermostat will mechanically turn on heat if temperature drops to 40°F (4°C) ­even if batteries are missing or drained.
• Automatic heating shutdown if temperature exceeds 90°F (32°C).
Replacing Existing Thermostat
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not disconnect wires. (See Figure 1)
3. Label wires per Table 1.
Table 1
Old Label New Label Description
M, 4, RH, R5 or R RH Heat Transformer,
hot side
V or RC RC Cooling Transformer, hot
side Y or Y6 Y Cooling control H, W or 4 W Heating control F or G G Fan control relay C* Y or None Either cooling control or
common side of trans-
former
*NOTE: ON SOME OLDER MODELS, THE C TERMINAL CAN BE EITHER THE COOLING
CONTROL OR THE COMMON SIDE OF THE TRANSFORMER
. CHECK FURNACE WIRING
DIAGRAM TO VERIFY
C TERMINAL. IFITISTHE COMMON SIDE OF THE
TRANSFORMER
, CAP THE WIRE AND TUCK INTO THE WALL. IFITISTHECOOLING
CONTROL
, CONNECT TO THE Y TERMINAL.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install thermostat.
2
Figure 1
Installing Item 9600 Thermostat
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEET
ABOVE THE FLOOR
. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS,
IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION
.
1. Turn power off to the heating and cooling systems.
2. Place COOL-OFF-HEAT in OFF position.
3. Place AUTO–ON switch into AUTO position.
4. Remove the cover using a coin or screwdriver.
Figure 2
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat.
6. Mark placement of mounting holes (see Figure 3). Set base aside.
3
>
>
PROG MAN
SET PROG/MAN COOL-OFF-HEAT AUTO - ON
COOL-OFF-HEAT
AUTO - ON
Figure 3
7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall.
8. Tap plastic anchors into the wall.
9. Align base with plastic anchors and feed wires through opening (see Figure 4).
Figure 4
10. Secure base to wall with supplied screws.
11. Connect wires to terminal strip. Refer to wiring diagrams on other side of this sheet. Make sure wire connections are secure.
12. Place fan option switch into either the ELEC or GAS position depend­ing on the type of furnace. Refer to Figure 5.
Figure 5
4
PROG
MAN
CHANGE SET AUTO/MAN
Elec Gas
RH
AM PM
MORN DAY EVE NITE
RC
W Y
G
FAN AUTO ON
MOUNTING HOLES
COOL OFF HEAT
PROG
MAN
CHANGE SET AUTO/MAN
Elec Gas
RH
AM PM
MORN DAY EVE NITE
RC
W Y
G
FAN AUTO ONCOOL OFF HEAT
PROG
MAN
CHANGE SET AUTO/MAN
Elec Gas
RH
AM PM
MORN DAY EVE NITE
RC
W
Y G
FAN AUTO ON
FAN OPTION SWITCH
Controls fan delay.
COOL OFF HEAT