Robertshaw 9401 User Manual

Application
The Robertshaw 9401 is a single-stage thermostat designed to control 24 VAC gas or electric heating and cooling systems or single-stage heat pump. The 9401 requires the use of a common wire.
Features
• Summer and winter setpoints
•Large back lit display
• Adjustable temperature differential: .5°F to 3.0°F (0.5°C to 1.5°C)
•Accuracy within ±1°
• Zone system compatible as a master thermostat
• Permanent memory retention
• Fahrenheit/Celsius display option
• Adjustable from 45°F to 90°F (7°C - 32°C)
• Quick wire terminal block
• Automatic heating shutdown if temperature exceeds 94°F (34°C)
1
DIGITAL NON-PROGRAMMABLE THERMOSTAT
9401
ELECTRIC
E
GAS
G
OIL
O
®
NeW
1 Heat / 1 Cool
User's Manual
Quick Start Installation
110-1041
IMPORTANT SAFETY INFORMATION WARNING:
• Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat.
• Read all the information in this manual before installing this thermostat.
• This is a 24 VAC low-voltage thermostat. Do not install on voltages higher than 30 VAC.
• All wiring must conform to local and national building and electrical codes and ordinances.
• Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
• Do not connect ground to any terminal in this unit.
Step 1: Replacing Existing Thermostat
1. Turn off power to heating and cooling system.
2. Remove cover from old thermostat to expose wires (Figure 1).
3. Disconnect wires one at a time from existing terminals. Use enclosed labels to mark existing wires. Refer to cross references in Table 1 if existing wiring does not directly match the labels.
4. Remove existing thermostat base from wall.
Old Terminal New Label Description
M,W,Rh,R5 or 5 Rh Heat transformer, hot side V or Rc Rc Cool transformer, hot side C,X, or B C 24VAC transformer, common side Y or Y6 Y Cooling control H,W, or 4 W Heating control F or G G Fan control relay OOCool active reversing valve BBHeat active reversing valve
NOTE: THIS THERMOSTAT REQUIRES A 24V AC COMMON WIRE FOR PROPER OPERATION.
Table 1
2
Figure 1
!
Recycling Thermostat
If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the garbage. Contact your local waste management authority for instructions regarding proper disposal of the thermostat. If you have any ques­tions, call Robertshaw technical support at 1-800-445-8299.
Step 2: Installing Model 9401 Thermostat
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON
INSIDE WALL, FIVE FEET ABOVE THE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE LOCATIONS WILL AFFECT THERMOSTAT OPERATION.
1. Turn power off to the heating and cooling systems.
2. Place HEAT-OFF-COOL in OFF position (Figure 2).
3. Place -ON-AUTO switch into AUTO position (Figure 2).
4. Remove the cover using a coin or screwdriver (Figure 3). Set aside.
3
Figure 3
Figure 2
Maple Chase Company www.maplechase.com
TM
Tech Service: 1-800-445-8299 M-F 7:30 a.m. - 5:30 p.m. CST
Item
9555
MADEINMEXICO
SETTING OR CHANGING THE SETPOINT TEMPERATURE:
1.Press or button. Display will show SET and the current temperature setpoint.
2. Press or button to adjust temperature setpoint.
3. After completing the change, the display will return to the curr
ent
room temperatur
e after a few seconds.
CHANGING THE TEMPERATURE DIFFERENTIAL, DEAD BAND, AND RESIDUAL COOL:
The temperature differentials are factory set at 1˚F and 2˚F for 1STand 2NDstages respectively. The dead band for Auto­changeover is set at 3˚F. To change settings:
1.Press the and buttons at the same time and hold for 1 second. Display will indicate: DIFFERENTIAL 1ST.
2. Press either the or button to adjust the 1st stage differ­ential between 0.5˚F – 3˚F (0.5˚C - 1.5˚C).
3. Either wait five seconds or press the button. The display
will indicate: DIFFERENTIAL 2ND.
4.Press either the or button to adjust 2nd stage differen­tial between 1˚F – 6˚F (1˚C - 3˚C).
5. Either wait five seconds or press the button. The display
will indicate: DEADBAND.
6.Press either the or button to adjust the dead band between 3˚F – 6˚F (1.5˚C - 3˚C).
7.Either wait five seconds or press the button.The fan icon and ON will be displayed.
8. Press either the or button to adjust the Residual Cool fan delay between 0, 30, 60, or 90 seconds.
9.The display will return to the current room temperature after a few seconds.
120-1523
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening (Figure 4) on base of thermostat.
6. Mark placement of mounting holes (Figure 4). Set base aside.
7. If mounting on drywall, tap plastic anchors into wall.
NOTE: ENCLOSED PLASTIC ANCHORS DO NOT REQUIRE A
DRILLED HOLE FOR DRYWALL.
8. If mounting on a surface other than drywall, drill the marked holes using a 3/16" drill bit.
9. Align base with plastic anchors and feed wires through opening.
10. Secure base to wall with supplied screws.
NOTE: THE THERMOSTAT WILL MOUNT HORIZONTALLY
ON A SINGLE GANG JUNCTION BOX.
11. Strip end of wires 5/16” if needed.
12. Terminal screws are already loose and ready for wire insertion. Insert wires into terminal strip (Figure 5) matching the label to the corresponding terminal (see Wiring Diagrams). Tighten screws.
13. Make sure wire connections are secure.
14. Push excess wire back through opening.
4
Figure 4
W
Rh Rc C
Y
B
O
G
Label
Y
Figure 5
Mounting Holes
RESET
NON-HP
HP
Wiring Opening
ELECGAS