Robertshaw 8601-1 User Manual

1
Application
The Robertshaw 8601 is a single-stage thermostat designed to control 24 VAC gas or electric heating and cooling systems or single-stage heat pump. The 8601 requires a common wire.
Features
• Large backlit display.
NERGY STAR
®
setpoints for each day of
the week.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (4°C) to 90°F (32°C).
• Accuracy within ± 1 degree.
• Adjustable temperature differential: 1-3 °F (1-1.5°C).
• Separate heating and cooling programs.
110-1098B
5 - 2 Day Programmable 1 Heat / 1 Cool
User’s Manual
Quick Start Installation and Programming
W
A
R
R
A
N
T
Y
2
T
W
O
Y
E
A
R
DIGITAL PROGRAMMABLE THERMOSTAT
8
601
ELECTRIC
E
GAS
G
OIL
O
®
NeW
HEAT PUMP
H
As an ENERGY STAR®partner, Invensys Controls Americas has determined that this thermostat meets the ENERGY STAR®guidelines for energy efficiency.
110-1165
110-1165 6/8/05 11:51 AM Page 1
WARNING:
Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or programming this thermostat.
DO NOT CONNECT TO 120 VAC. This is a 24V AC low voltage ther­mostat. Do not install on voltages higher than 30V AC.
All wiring must conform to local and national building and electrical codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
Do not connect ground to any terminal in this unit.
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys Controls Americas or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Controls Americas 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center
Replacing Existing Thermostat
Wiring Table
Old Label New Label Description
M, W, Rh, Rc R 24VAC, hot side R5, V or 5
C, X or B C 24VAC, common side
Y or Y6 Y1 Cooling control
H, W or 4 W1 Heating control
F or G G Fan control relay
O O Cool active reversing valve
B B Heat active reversing valve
NOTE: THIS THERMOSTAT REQUIRES A 24 VAC COMMON WIRE FOR PROPER OPERATION.
NOTE: ON SOME OLDER MODELS, THE C TERMINAL CAN BE EITHER THE COOLING CONTROL OR
THE COMMON SIDE OF THE TRANSFORMER. CHECK FURNACE WIRING DIAGRAM TO VERIFY C TERMINAL. IF IT IS THE COMMON SIDE OF THE TRANSFORMER, CONNECT TO THE C TERMINAL.
2
!
110-1165 6/8/05 11:51 AM Page 2
WARNING:
In heat pump applications, do not connect anything to the W1 terminal. When switched to HP mode, W1 is connected internally to Y1 on the thermostat.
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not disconnect wires. (See Figure 1)
3. Label wires per the Wiring Table.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install thermostat.
Figure 1
Installing Item 8601 Thermostat
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEET
ABOVE THE FLOOR
. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS,
IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION
.
1. Turn power off to the heating and cooling systems.
2. Place HEAT-OFF-A/C in OFF position.
3. Place AUTO ON switch into AUTO position.
4. Remove the cover using a coin or screwdriver (see Figure 2).
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat.
3
h
e
a
t o
ff c
o
o
l
h
o
ld
v
a
c
p
r
o
g
r
u
n
/s
e
t
h
o
ld
te
m
p
c
lo
c
k
s
e
t
a
u
to
o
n
M
O
N
°
F
select
set
°
a/coffheat
onauto
Figure 2
!
110-1165 6/8/05 11:51 AM Page 3
temp
prog
hold
select
°
F
vac
set
a/coffheat
MON
onauto
6. Mark placement of mounting holes (see Figure 3). Set base aside.
7. Drill the marked holes using a 3/16” (5mm) drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall.
8. Tap plastic anchors into the wall.
9. Align base with plastic anchors and feed wires through opening (see Figure 3).
10. Secure base to wall with supplied screws.
11. Connect wires to terminal strip. Refer to wiring diagrams on page 5. Make sure wire connections are secure.
12. Place Electric/Gas switch into either the ELEC or GAS position depending on the type of furnace (see Figure 3).
13. Place the HP option switch into either the NON_HP or HP position depending on the type of system you are using (see Figure 3). Use the HP position for heat pumps ONLY. Use the NON_HP setting for everything else.
14. Replace cover on thermostat by snapping into place.
15. Turn on power to system. Test thermostat as described in the section To Test Thermostat.