Robertshaw 8600 User Manual

1
Application
The Robertshaw 8600 is a single-stage thermostat designed to control 24 VAC gas or electric heating and cooling systems or single-stage heat pump.
Features
• Large back lit display.
• Four preprogrammed ENERGY STA R®setpoints for each day of the week.
• Two AA ENERGIZER brand batteries retain time of day settings even during power outages.
• Low battery indicator.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (4°C) to 90°F (32°C).
• Accuracy within ± 1 degree.
• Adjustable temperature differential: 1-3 °F (1-1.5°C).
• Separate heating and cooling programs.
110-1097
5 - 2 Day Programmable 1 Heat / 1 Cool
User’s Manual
Quick Start Installation and Programming
W
A
R
R
A
N
T
Y
2
T
W
O
Y
E
A
R
DIGITAL PROGRAMMABLE THERMOSTAT
8
600
ELECTRIC
E
GAS
G
OIL
O
®
NeW
HEAT PUMP
H
As an ENERGY STA R®partner, Climate Controls Americas has determined that this thermostat product meets the ENERGY STA R®guidelines for energy efficiency.
IMPORTANT SAFETY INFORMATION WARNING:
Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or programming this thermostat.
DO NOT CONNECT TO 120 VAC. This is a 24V AC low voltage ther­mostat. Do not install on voltages higher than 30V AC.
All wiring must conform to local and national building and electrical codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
Do not connect ground to any terminal in this unit.
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys Climate Controls or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Climate Controls 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center
Replacing Existing Thermostat
Wiring Table
Old Label New Label Description
M, W, RH, R5 or R RH Heat transformer, hot side
V or RC RC Cooling transformer, hot side
Y or Y6 Y1 Cooling control
H, W or 4 W1 Heating control
F or G G Fan control relay
O O Cool active reversing valve
B B Heat active reversing valve
NOTE: ON SOME OLDER MODELS, THE C TERMINAL CAN BE EITHER THE COOLING CONTROL OR
THE COMMON SIDE OF THE TRANSFORMER. CHECK FURNACE WIRING DIAGRAM TO VERIFY C TERMINAL. IF IT IS THE COMMON SIDE OF THE TRANSFORMER, CAP THE WIRE AND TUCK INTO THE WALL. IF IT IS THE COOLING CONTROL, CONNECT TO THE Y TERMINAL.
2
!
IMPORTANT SAFETY INFORMATION WARNING:
In heat pump applications, do not connect anything to the W1 terminal. When switched to HP mode, W1 is connected internally to Y1 on the thermostat.
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not disconnect wires. (See Figure 1)
3. Label wires per the Wiring Table.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install thermostat.
Figure 1
Installing Item 8600 Thermostat
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEET
ABOVE THE FLOOR
. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS,
IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION
.
1. Turn power off to the heating and cooling systems.
2. Place HEAT-OFF-COOL in OFF position.
3. Place AUTO–ON switch into AUTO position.
4. Remove the cover using a coin or screwdriver (see Figure 2).
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat.
3
heat off cool
hold
vac
prog
run/set
hold
temp
clock
set
auto on
M
O
N
°
F
sele
ct
se
t
heat off cool
auto on
Figure 2
!
MON
run/set
prog
select
heat off cool
temp hold
auto on
°
F
set
vac
clock
hold
set
6. Mark placement of mounting holes (see Figure 3). Set base aside.
7. Drill the marked holes using a 3/16” (5mm) drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall.
8. Tap plastic anchors into the wall.
9. Align base with plastic anchors and feed wires through opening (see Figure 3).
10. Secure base to wall with supplied screws.
11. Connect wires to terminal strip. Refer to wiring diagrams on page 5. Make sure wire connections are secure.
12. Place Electric/Gas switch into either the ELEC or GAS position depending on the type of furnace (see Figure 3).
13. Place the HP option switch into either the NON_HP or HP position depending on the type of system you are using (see Figure 3). Use the HP position for heat pumps ONLY. Use the NON_HP setting for everything else.
14. Install two AA ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. See Figure 3 for correct battery placement.
15. Replace cover on thermostat by snapping into place.
16. Turn on power to system. Test thermostat as described in the section To Test Thermostat.
4
Mounting Holes
ELECTRIC/GAS SWITCH Selects fan control.
+
+ _
_
HP OPTION SWITCH Heat pump switch.
Figure 3
Correct battery placement
MON
GOBY1W1
°
F
RH
RC
Loading...
+ 8 hidden pages