Robertshaw 8600 User Manual

1
Application
The Robertshaw 8600 is a single-stage thermostat designed to control 24 VAC gas or electric heating and cooling systems or single-stage heat pump.
Features
• Large back lit display.
• Four preprogrammed ENERGY STA R®setpoints for each day of the week.
• Two AA ENERGIZER brand batteries retain time of day settings even during power outages.
• Low battery indicator.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (4°C) to 90°F (32°C).
• Accuracy within ± 1 degree.
• Adjustable temperature differential: 1-3 °F (1-1.5°C).
• Separate heating and cooling programs.
110-1097
5 - 2 Day Programmable 1 Heat / 1 Cool
User’s Manual
Quick Start Installation and Programming
W
A
R
R
A
N
T
Y
2
T
W
O
Y
E
A
R
DIGITAL PROGRAMMABLE THERMOSTAT
8
600
ELECTRIC
E
GAS
G
OIL
O
®
NeW
HEAT PUMP
H
As an ENERGY STA R®partner, Climate Controls Americas has determined that this thermostat product meets the ENERGY STA R®guidelines for energy efficiency.
IMPORTANT SAFETY INFORMATION WARNING:
Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or programming this thermostat.
DO NOT CONNECT TO 120 VAC. This is a 24V AC low voltage ther­mostat. Do not install on voltages higher than 30V AC.
All wiring must conform to local and national building and electrical codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
Do not connect ground to any terminal in this unit.
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely.
Return the mercury or mercury products, in a sealed container, to Invensys Climate Controls or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
Invensys Climate Controls 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center
Replacing Existing Thermostat
Wiring Table
Old Label New Label Description
M, W, RH, R5 or R RH Heat transformer, hot side
V or RC RC Cooling transformer, hot side
Y or Y6 Y1 Cooling control
H, W or 4 W1 Heating control
F or G G Fan control relay
O O Cool active reversing valve
B B Heat active reversing valve
NOTE: ON SOME OLDER MODELS, THE C TERMINAL CAN BE EITHER THE COOLING CONTROL OR
THE COMMON SIDE OF THE TRANSFORMER. CHECK FURNACE WIRING DIAGRAM TO VERIFY C TERMINAL. IF IT IS THE COMMON SIDE OF THE TRANSFORMER, CAP THE WIRE AND TUCK INTO THE WALL. IF IT IS THE COOLING CONTROL, CONNECT TO THE Y TERMINAL.
2
!
IMPORTANT SAFETY INFORMATION WARNING:
In heat pump applications, do not connect anything to the W1 terminal. When switched to HP mode, W1 is connected internally to Y1 on the thermostat.
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not disconnect wires. (See Figure 1)
3. Label wires per the Wiring Table.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to install thermostat.
Figure 1
Installing Item 8600 Thermostat
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEET
ABOVE THE FLOOR
. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS,
IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION
.
1. Turn power off to the heating and cooling systems.
2. Place HEAT-OFF-COOL in OFF position.
3. Place AUTO–ON switch into AUTO position.
4. Remove the cover using a coin or screwdriver (see Figure 2).
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat.
3
heat off cool
hold
vac
prog
run/set
hold
temp
clock
set
auto on
M
O
N
°
F
sele
ct
se
t
heat off cool
auto on
Figure 2
!
MON
run/set
prog
select
heat off cool
temp hold
auto on
°
F
set
vac
clock
hold
set
6. Mark placement of mounting holes (see Figure 3). Set base aside.
7. Drill the marked holes using a 3/16” (5mm) drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall.
8. Tap plastic anchors into the wall.
9. Align base with plastic anchors and feed wires through opening (see Figure 3).
10. Secure base to wall with supplied screws.
11. Connect wires to terminal strip. Refer to wiring diagrams on page 5. Make sure wire connections are secure.
12. Place Electric/Gas switch into either the ELEC or GAS position depending on the type of furnace (see Figure 3).
13. Place the HP option switch into either the NON_HP or HP position depending on the type of system you are using (see Figure 3). Use the HP position for heat pumps ONLY. Use the NON_HP setting for everything else.
14. Install two AA ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. See Figure 3 for correct battery placement.
15. Replace cover on thermostat by snapping into place.
16. Turn on power to system. Test thermostat as described in the section To Test Thermostat.
4
Mounting Holes
ELECTRIC/GAS SWITCH Selects fan control.
+
+ _
_
HP OPTION SWITCH Heat pump switch.
Figure 3
Correct battery placement
MON
GOBY1W1
°
F
RH
RC
Wiring Diagrams
The following is just a sample of the most common types of HVAC systems. Refer to your system’s installation manual for wiring information.
5
HEAT/COOL
4-WIRE
SINGLE TRANSFORMER
Transformer
Hot
120 VAC
24 VAC
Factory-Installed
Jumper
Heating Control
Cooling Control
Fan
Control
RH
RC
W1
Y1
G
O
B
T H E R M O S T A T
HEAT ONLY
3-WIRE
SINGLE TRANSFORMER
Transformer
Hot
120 VAC
24 VAC
Factory-Installed
Jumper
Heating Control
Fan
Control
RH
RC
W1
Y1
G
O
B
T H E R M O S T A T
HEAT ONLY
2-WIRE
SINGLE TRANSFORMER
120 VAC
Transformer
Hot
24 VAC
Heating
RH
RC
W1
Control
Y1
G
O
B
HEAT/COOL
TWO TRANSFORMER
(HEATING)
Transformer
Hot
120 VAC 24 VAC
Hot
24 VAC
120 VAC
(COOLING)
Transformer
HEAT PUMP WITH
COOL ACTIVE
REVERSING VALVE
Compressor
Contactor
Fan
Relay
Reversing
Valve
RH
RC
W1
Y1
G
O
B
Transformer
Hot
24 VAC
120 VAC
NOTE: Make sure the HP switch
is in the HP position
T H E R M O S T A T
5-WIRE
T H E R M O S T A T
SINGLE TRANSFORMER
Transformer
Hot
120 VAC
NOTE: Disconnect factory installed jumper.
RH
T H
RC
CAUTION: Both transformers
E
Heating Control
Cooling Control
Fan
Relay
must be in phase or damage to the equipment and thermostat
W1
R
may result.
M O
Y1
S T
G
A
O
T
B
HEAT PUMP WITH
REVERSING VALVE
NOTE: Factory Installed Jumper
Transformer
Hot
120 VAC
NOTE: Make sure the HP switch
COOL ONLY
3-WIRE
NOTE: Remove factory installed jumper
24 VAC
Cooling Control
Fan
Control
HEAT ACTIVE
24 VAC
Compressor
Contactor
Fan
Relay
Reversing
Valve
is in the HP position
RH
T
RC
H E
W1
R
Y1
M O S
G
T
O
A T
B
NOTE: Factory Installed Jumper
RH
T H
RC
E
W1
R M
Y1
O
G
S T A
O
T
B
6
To Test Thermostat
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS
VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE
IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY.
1. Place the HEAT-OFF-COOL switch into the COOL position. The will be displayed.
2. Press the button until the temperature setting is at least 3 degrees below the room temperature. The air conditioning system should turn on within a few seconds.
NOTE: ONCE THE THERMOSTAT TURNS OFF WHEN IN THE COOL MODE,
A BUILT IN 5-MINUTE DELAY PREVENTS THE SYSTEM FROM TURNING ON AGAIN. THIS PROTECTS THE COMPRESSOR. NO ADDITIONAL TIME DELAY RELAY IS REQUIRED. TO OVERRIDE THE 5-MINUTE DELAY FOR INSTALLATION, PRESS THE RESET BUTTON.
3. Put the HEAT-OFF-COOL switch into the OFF position. The air conditioning system should turn off.
4. Put the HEAT-OFF-COOL switch into the HEAT position. The will be displayed.
5. Press the button until the temperature setting is at least 3 degrees above room temperature. The heating system should turn on. The fan may not turn on immediately, depending on the fan delay built into the furnace.
NOTE: If HP is selected, the heat will not come on until the 5 minute
short cycle protection has expired.
6. Put the HEAT-OFF-COOL switch into the OFF position. The heating system should turn off. The fan may continue to run for a short period of time.
7. Put the AUTO-ON switch into the ON position. The blower fan should turn on. The display will show a .
8. Put the AUTO-ON switch into the AUTO position. The blower fan should turn off.
heat off cool
heat off cool
heat off cool
heat off cool
auto on
auto on
Programming Guide
SETTING TIME OF DAY AND DAY OF WEEK
1. Press SELECT until the cursor is over SET CLOCK. Press SET. The HOURS segment will be blinking. Use the or button to adjust the time. NOTE: The AM or PM indicator will change as the HOURS display rolls through a 24 hour cycle.
2. Press SET. The MINUTES segment will be blinking. Use the or button to adjust the MINUTES setting.
3. Press SET. The DAY segment will be blinking at the top of the display. Use the or button to adjust the day of the week. Press SET.
PROGRAMMING YOUR THERMOSTAT
The 8600 thermostat features 1-button programming. Simply follow these steps to customize your thermostat for your lifestyle.
1. Place the HEAT-OFF-COOL switch into the HEAT position. Make sure the cursor is in the RUN/SET PROG position. Press SET. The HOURS segment will be blinking. MON thru FRI (the work week) will be displayed across the top. AM1 will be illuminated in the lower right hand corner. You can now start programming the first event of the work week.
2. Use the or button to adjust the hour of the first event. Press SET.
3. The MINUTES segment will be blinking. Use the or button to adjust the minutes. Press SET.
4. The temperature should be blinking. Use the or button to adjust the desired temperature of the first event. Press SET.
5. AM2 should now be displayed. Repeat steps 2-4 to program the remaining events (PM1 and PM2) for the work week. There are a total of 4 events.
7
MON = MONDAY TUE = TUESDAY WED = WEDNESDAY THU = THURSDAY FRI = FRIDAY SAT = SATURDAY SUN = SUNDAY
select
set
hold
vac
prog
run/set
hold
temp
clock
set
Cursor
heat off cool
MON
temp
run/set
hold
prog
select
auto on
°
F
set
vac
clock
hold
set
6. After pressing SET for the 4th event, the day of the week along the top will switch to SAT SUN and AM1 will be displayed. Repeat steps 2-4 to program the weekend settings.
7. With the weekend settings programmed, place the HEAT-OFF-COOL switch in the COOL position. Repeat steps 2-6 to program the cooling settings.
CUSTOMIZING YOUR THERMOSTAT
Settings
System
Cool: The thermostat controls the cooling. Off: The heating and cooling systems are off. Heat: The thermostat controls the heat.
Fan
Auto: Equipment controls the fan. On: The fan operates continuously.
Temperature Differential
The temperature differential is factory set at 1.0°F (.5°C). This means that whenever the room temperature changes by one degree Fahrenheit from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential.
Changing Fahrenheit (°F) to Celsius (°C), Clock Setting, Temperature Differential, and Filter Monitor
You can change temperature scales (F or C), set a 12 or 24 hour clock, adjust differentials and change the filter monitor setting by following these instructions.
1. Press SELECT and SET at the same time. Hold for 3 seconds. An F should be blinking in the display. Use the or button to toggle between Farhenheit (F) or Celsius (C).
2. Press SET. CLOC will be displayed in the lower left corner. Use the or button to toggle between 12 or 24 for the clock setting.
3. Press SET. diFF will be displayed in the lower left corner. Use the or button to adjust the 1st stage differential between 1°F and 3°F (1°C and 1.5°C).
4. Press SET. CHECK FILTER will be displayed and the length of the filter set­ting will be blinking in the lower left cor­ner. Use the or button to adjust the filter setting from 0 (OFF) to 9900 hours. NOTE: The filter timer is based on equipment run time. Select the length of time based on your filter's recommended service interval.
5. Press SET or wait 5 seconds and the thermostat will return to the normal operating mode.
8
Begin Programmed Operation
1. Make sure the cursor is above RUN/SET PROG.
2. Place AUTO–ON switch into AUTO.
3. Place HEAT-OFF-COOL switch into COOL or HEAT depending on the season.
Temporary Program Hold
You can temporarily increase or decrease the temperature and hold it for 3 hours or until the next program event, whichever comes first.
1. Press the or button. The temperature will blink. Using the or button, adjust the temperature to the desired level.
2. Press SET.
Another way to select a temporary hold is:
1. Press SELECT until the cursor is over TEMP HOLD. Press SET. The temperature will be blinking. Use the or button to change the temperature.
2. Press SET.
To cancel a temporary hold, press SELECT until the cursor is above RUN/SET PROG. Press SET.
Vacation Hold
You can set your thermostat to hold a desired temperature for 1-365 days. Vacation hold terminates at midnight of the last day. The thermostat returns to normal operation the next day at 12:01 AM.
1. Press SELECT until the cursor is over VAC HOLD. Press SET. The temperature will be blinking. Use the or button to change the temperature.
2. Press SET. 7d will be displayed. Use the or button to adjust between 1 and 365 days.
3. Press SET.
To cancel a vacation hold, press SELECT until the cursor is above RUN/SET PROG. Press SET.
9
heat off cool
auto on
select
hold
vac
prog
run/set
hold
temp
clo
s
heat off cool
auto on
MON
°
F
set
temp
vac
run/set
clock
hold
hold
prog
select
set
Check Filter Reset
Once the filter timer has expired, CHECK FILTER will turn on and stay on. To clear the message and reset the timer:
1. Press SELECT and SET and hold for 3 seconds. CLr will appear in the time display.
2. Press any key to clear the message. The display will transition to the tem­perature scale display. See step 4 in CUSTOMIZING YOUR THERMOSTAT.
3. No further input is needed. Within a few seconds, the display will return to the normal operating mode.
Reset
The RESET button is located above the upper left corner of the display. Only use the reset feature if the thermostat is malfunctioning.
10
RESET BUTTON
MON
GOBY1W1
°
F
RH
RC
Troubleshooting
Symptom Remedy
Thermostat does not turn Check wiring. on system. (See Installing Item 8600
Thermostat)
Thermostat turns on and off too Increase temperature differential. frequently. (See Programming Guide)
Display is blank, flashing or Replace batteries. constant LO BAT.
System fan does not operate Move Electric/Gas switch to properly. either gas or electric, to match
system. (See Installing Item 8600 Thermostat)
Time shown on display is not the Change time of day setting. current time of day. (See Programming Guide)
Thermostat does not Thermostat may not have been follow program. programmed in HEAT or COOL
position. Verify program.
Check AM/PM indicators at time of day and programmed time changes. (See Programming Guide)
Verify program and day of week are correct. (See Programming Guide)
If problems with thermostat cannot be resolved, call:
Technical Support: (800) 445-8299
Monday-Friday 7:30-5:30 CST
For after hours service, a 24-hour
automated help line is available.
For warranty returns, send thermostat, shipping prepaid to:
Climate Controls Americas
Warranty Department
515 South Promenade Avenue
Corona, CA 91719
11
12
©2004 Climate Controls Americas 110-1097
Climate Controls Americas
191 E. North Avenue Carol Stream, Illinois 60188 United States of America
TWO-YEAR LIMITED WARRANTY
Climate Controls Americas warrants to the original contractor
installer or to the original consumer user, each new Robertshaw thermo­stat to be free from defects in materials and workmanship under normal use and service for a period of two (2) years from date of purchase. This warranty and our liability does not apply to batteries or merchandise that has been damaged by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in accordance with Climate Controls Americas recommendations and instructions.
Climate Controls Americas agrees to repair or replace at its option
any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of ther­mostat removal or reinstallation is not the responsibility of Climate Controls Americas.
Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. Climate Controls Americas shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, or under any other theory of liability. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limit­ed to the duration of this warranty.
Some states do not allow the exclusion or limitation of incidental or con­sequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Loading...