Robertshaw 8000 Series Installation Instructions Manual

SINGLE LEVEL PRESSURE SWITCHES
The Robertshaw® 8000 Series Single Level Pressure Switches will replace several models of Robertshaw switches used on sump pumps
and other similar appliances. A typical applicaon on a sump pump unit is shown at right. The switch operates as an automac control device
which turns the pump motor on when the water level rises and turns it
ELECTRICAL RATING
15 Amps - 125-250V AC 1/2 H.P. - 125-250V AC UL and CSA listed
INSTALLATION INSTRUCTIONS
1. Disconnect POWER SUPPLY.
2. Remove old switch and note terminal wiring before disconnecng leads.
3. Aach leads to new switch and install switch in operang posion. NOTE: Some applicaons require the switch to be submerged in liquid
(sump pumps). A gasket is used to seal the terminal area from the liquid. When replacing this type switch use new neoprene gasket supplied with switch. Be certain gasket is located on same side of switch as old gasket.
4. Secure switch rmly in place and reassemble any other parts if their removal was required.
Figure 1 - Flat Opening
INSTALLATION DATA
8000 SERIES
Figure 3 - Standard SPST
Figure 4 - SPST With Ground Terminal
Figure 2 - Tubing Opening
CAUTION
THIS DEVICE SHOULD BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN WITH DUE REGARD FOR SAFETY AS IMPROPER INSTALLATION COULD RESULT IN A HAZARDOUS CONDITION.
Figure 5 - Standard SPDT
ORDERING INFORMATION
1. Locate FACTORY NUMBER which is usually stamped on the boom of the switch. (See gure 1.)
2. Cross reference factory number to Uni-Line number in Funconal
Replacement Guide. If not listed, follow step 3.
3. Determine NUMBER OF TERMINALS and SWITCH ACTION. Refer to
gures 3, 4, and 5.
4. Determine PRESSURE OPENING TYPE - tubing or wide mouth
5. Note turn on - turn o level setpoint if important to your applicaon.
6. In the ordering charts below, models are grouped according to switch acon and type of opening. Select a funconal replace ment from the appropriate chart.
7. If you cannot nd a replacement on the charts, send full infor maon to your Uni-Line wholesaler. It oen helps to send
in old control.
opening and approximate size opening gure 1 and 2.
FLAT OPENING - SPST
Order Number
8000-001 606-0544-01 8.0” 2.0” 3 1-1/8” 8000-002 606-0545-01 5.0” 1.5” 2 2-1/4” 8000-003 606-0546-01 7.0” 1.5” 2 1/2” Universal Electric 27P6A-1 8000-004 277-9602-01 12.0” 2.25” 2 1-1/8” N/A None Marathon Electric A-7963-2 8000-010 606-0577-01 9.0” 2.25” 2 2-1/4” 8000-011 606-0597-01 6.0” 1.5” 2 2-1/4” Hydr-O-Mac Pump 5977 8000-042 606-0634-01 7.0” 1.5” 2 2-1/4” Universal Electric 27P49
Factory
Model Number
Turn “On”
Level
Turn “O”
Level
Number of
Terminals
“A”
Dimension
“B”
Dimension
Mounng
Bracket Type
O.E.M. and Part Number
FLAT OPENING - SPDT
8000-040 606-0521-00 10.0” 2.0” 3 1-1/8” Sta-Rite U217-199 8000-041 606-0613-00 10.0” 3.0” 3 1/2” Thomas Becke ZT136
N/A
None
TUBING OPENING - SPST
8000-008 606-0527-01 2.0” 1.0” 2 7/32” 7/8” #3 Morse Inst. B43788 8000-020 277-9613-01 7.0” 1.5” 2 1/2” 5/8” 8000-021 277-9563-01 5.0” 1.5” 2 7/32” 13/32” 8000-022† 277-9554-01 8.0” 2.0” 3 7/32” 7/8” Barnes MFG. 21319 8000-023 606-0560-01 1.8” .5” 2 7/32” 13/32” 8000-024 277-9539-00 8.0” 3.0” 3 7/32” 7/8” None 8000-025 606-0561-01 8.0” 2.0” 2 7/32” 7/8” 8000-026 606-0557-01 10.5” 4.5” 2 7/32” 7/8” Triangle Pump LA3 8000-027 606-0603-01 11.0” 1.5” 2 7/32” 7/8” 8000-072 277-9683-01 5.0” 1.5” 2 7/32” 13/32” 8000-080* 277-9556-02 1.0” to 3.0” 5.7” 2 1/2” 5/8” Design and MFG. 81404-2
TUBING OPENING - SPDT
8000-007 606-0022-00 12.5” 3.8” 3 7/32” 57/64” SPL. Franklin Appl. C66917-D 8000-012 606-0007-00 9.5” 3.0” 3 7/32” 5/8” ** Maytag 2-1754 8000-060 277-9545-00 5.2” 2.0” 3 1/2” 5/8” None 8000-061 277-9665-00 7.0” 1.5” 3 7/32” 13/32” None Penberthy MFG. D-1575 8000-062 606-0542-00 11.0” 2.0” 3 1/2” 5/8” None Penberthy MFG. 42030-002 8000-063 278-9564-00 3.0” 1.0” to 2.5” 3 7/32” 7/8” #1 8000-064 606-0501-00 8.4” 3.0” 3 7/32” 7/8” SPL. Whirlpool 94664 8000-065 278-9668-00 2.0” .5” 3 1/2” 5/8” None 8000-066 277-9607-00 8.0” 1.0” 3 7/32” 7/8” SPL. York 25-11177B 8000-067 278-9667-00 1.9” .5” 3 7/32” 13/32” #3 Ametek 262-192-1 8000-068†† 277-9540-02 5.3” 1.0” 3 1/2” 5/8” None Design and MFG. 81404-1 8000-069 277-9584-00 4.0” 2.0” 3 7/32” 7/8” SPL. York T-4726 8000-070 277-9675-00 4.15” .5” 3 7/32” 13/32” SPL. 8000-071 606-0574-00 12.0” 6.0” 3 7/32” 7/8” #1 Industral Filter and Pump 42-0233 8000-073• 279-9632-00 5.5” to 12.0” 1.0” to 3.0” 3 7/32” 27/64” SPL. Ametek 262-718 8000-074 605-0559-00 7.0” 1.0” 3 1/2” 5/8” #2
8000-093• 279-9643-00 9.0” to 16.0” 1.5” 3 7/32” 13/32 SPL
* Reverse acng **Has three push buons - lo, med & hi
† Has special .025 orice in tube †† Has special .035 orice in tube
• Has .188” “D” stem - dial sha adjustment
Customer Service Telephone 1.800.304.6563 Customer Service Facsimile 1.800.426.0804 HVACCustomerService@robertshaw.com
For Technical Service Telephone 1.800.445.8299 Facsimile 1.630.260.7294 TechnicalService@robertshaw.com
Robertshaw®, Ranco®, Paragon® and Uni-Line® are trademarks of Robertshaw, its subsidiaries and/or affiliated companies. All other brands mentioned may be the trademarks of their respective owners.
www.uni-line.com www.robertshaw.com ©2015 Robertshaw 2/15 –1-131 Rev B
Loading...