Roberts Gorden HE45UT, HE45ST, HE30ST, HE30DL, HE70DL User Manual

...
WARNING
FOR YOUR SAFETY If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance.
3. DO NOT use electrical switches.
4. DO NOT use any telephone in your building.
5. Extinguish any open flame.
6. Leave the building.
7. Immediately call your local gas supplier after leaving the building. Follow the gas supplier’s instructions.
8. If you cannot reach your gas supplier, call the Fire Department.
Fire Hazard
Keep all flammable objects, liquids and vapors the minimum required clear­ances to combustibles away from heater.
Some objects will catch fire or explode when placed close to heater.
Failure to follow these instructions can result in death, injury or property damage.
WARNING
Installation must be done by a registered installer/ contractor qualified in the installation and service of gas-fired heating equipment or your gas supplier.
Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the installation, operation and service manual thoroughly before installing or servicing this equipment.
®
Blackheat
HE
Vacuum Assisted
Linear, Double Linear,
U-Tube, and Multi-Burner
Gas Fired Heating Systems
Installation, Operation &
Service Manual
HE15UT HE20UT HE25UT HE30UT
HE15ST HE20ST HE25ST HE30ST
HE30DL HE40DL HE50DL HE60DL
© 2010 Roberts-Gordon LLC
HE35UT HE40UT HE45UT HE50UT
HE35ST HE40ST HE45ST HE50ST
HE70DL
IP55 Protected Burner Box
Installer
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Owner
Keep this manual in a safe place in order to provide
your serviceman with necessary information.
Roberts-Gordon Europe Limited
Unit A, Kings Hill Business Park Darlaston Road, Wednesbury West Midlands WS10 7SH UK Telephone: +44(0)121 506 7700 Fax: +44(0)121 506 7701 Service Telephone: +44(0)121 506 7709 Service Fax: +44(0)121 506 7702
E-mail: uksales@rg-inc.com E-mail: export@rg-inc.com
www.rg-inc.com
170102UK Rev E 09/10
TABLE OF CONTENTS
© 2010
Roberts-Gordon Europe Limited
All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of Roberts-Gordon Europe Limited.
SECTION 1: Heater Safety ............................................2
1.1 Manpower Requirements ....................................2
1.2 IP55 Protection....................................................2
1.3 Safety Labels and Their Placement ....................2
SECTION 2: Installer Responsibility............................4
2.1 Low Level User Instructions................................4
2.2 Corrosive Chemicals...........................................4
2.3 National Standards and Applicable Codes .........4
SECTION 3: Clearances To Combustibles..................5
3.1 Required Clearances to Combustibles ...............5
3.2 Clearances Data - Linear and Double Linear .....6
3.3 Clearances Data - U-Tube ..................................8
SECTION 4: Major Component Descriptions............ 10
SECTION 5: General Suspension Details ................. 11
SECTION 6: Linear & Double Linear Heater
Installation .............................................. 13
6.1 Linear Standard Parts List ................................13
6.2 Double Linear Standard Parts List....................16
6.3 Burner Tube Installation ...................................19
6.4 Coupling and Tube Assembly...........................19
6.5 Tube Clamp Package Installation .....................21
6.6 Reflector Installation .........................................22
6.7 Double Linear Tee Installation
(For Double Linear Heaters Only) .....................24
SECTION 7: U-tube Heater Installation .....................25
7.1 U-tube Standard Parts List ................................25
7.2 U-tube Hanger Placement ................................29
7.3 Burner Tube and Fan Tube Installation ............29
7.4 U-tube Support Bracket Assembly
Installation.........................................................30
7.5 Coupling and Tube Assembly...........................31
7.6 Tube Installation ...............................................32
7.7 U-tube Installation.............................................32
7.8 Reflector Installation .........................................33
SECTION 8: Multiburner Configuration &
Installation ..............................................35
8.1 Initial Assembly.................................................35
SECTION 9: Burner & Fan Installation ......................37
9.1 Burner Installation.............................................37
9.2 Standard Fan Assembly ...................................37
9.3 IP55 Fan Assembly...........................................38
9.4 Linear & U-tube Fan Installation .......................38
9.5 Double Linear Fan Installation ..........................39
9.6 Multiburner 83/90 BWLG Fan Assembly
(Horizontal and Vertical Outlets).......................40
9.7 Condensate Drain Assembly ............................40
SECTION 10: Optional Heater Accessories ..............41
10.1 Reflector Side Extension Installation...............42
10.2 U-Tube Cover Installation................................43
10.3 Decorative Grille Installation ...........................44
10.4 Protective Grille Installation.............................45
10.5 Sports Hall Guard Installation.........................46
10.6 Undershield Installation ..................................47
10.7 Wall Mounting .................................................48
SECTION 11: Venting and Fresh Air Supply ............. 49
11.1 Type C12 , C32 & C62 Appliance ....................49
11.2 Type B22 Appliance.........................................49
11.3 Flue Installation ............................................... 49
11.4 Ventilation Requirements................................. 49
11.5 Fresh Air Supply .............................................. 49
11.6 Outside Combustion Air Supply....................... 50
11.7 Common Duct ................................................. 51
SECTION 12: Gas Piping ............................................ 52
SECTION 13: Wiring.................................................... 54
13.1 Typical External Wiring Diagram
(Linear or U-Tube) .......................................... 54
13.2 Typical External Wiring Diagram
Double Linear Option 1) ................................. 55
13.3 Typical External Wiring Diagram
(Double Linear Option 2) ................................55
13.4 Typical External Wiring Diagram
(Multiburner) ................................................... 55
13.5 Internal Wiring Diagram ................................. 56
SECTION 14: Operation..............................................57
14.1 Heater Lockout Indication (Optional) .............. 57
14.2 Testing ............................................................58
14.3 Commissioning (Multiburner)..........................58
14.4 System Checks ............................................... 58
14.5 User Instructions.............................................58
SECTION 15: Servicing Instructions .........................59
15.1 Annual Procedure ...........................................59
15.2 Sealing Gaskets ............................................. 59
15.3 Component Removal......................................59
15.4 Maintenance Checklist.................................... 60
SECTION 16: Troubleshooting................................... 62
16.1 Troubleshooting Flow Chart (Linear, Double
Linear and U-Tube)......................................... 63
16.2 Troubleshooting Flow Chart (Multiburner) ...... 65
16.3 Manifold Gas Pressure Setting .......................67
SECTION 17: Replacement Parts............................... 68
17.1 Replacement Packages................................... 70
SECTION 18: Specifications....................................... 71
18.1 Material Specifications .................................... 71
18.2 Heater Specifications......................................71
18.3 Venting Specifications.....................................71
18.4 Suspension Specifications..............................71
18.5 Controls Specifications ................................... 71
18.6 Linear Heater..................................................72
18.7 Double Linear Heater...................................... 72
18.8 U-tube Heater ................................................. 72
18.9 Burner Specifications......................................73
Printed in U.K.
TABLE OF FIGURES
Figure 1: Bottom and Back Panel Label Placement ........2
Figure 2: Control Side Label Placement..........................3
Figure 3: Linear & Double Linear, Horizontal Mounts......6
Figure 4: Linear & Double Linear, One Side Reflector ....6
Figure 5: Linear & Double Linear, Two Side Reflectors ...6
Figure 6: Linear & Double Linear, 45° Mount ..................6
Figure 7: Linear & Double Linear, 2 Foot Deco Grille,
Protective Grille ................................................7
Figure 8: Undershield .....................................................7
Figure 9: Linear & Double Linear, Venting.......................7
Figure 10: U-Tube, Horizontal Mount...............................8
Figure 11: U-Tube, One Side Reflector............................8
Figure 12: U-Tube, Two Side Reflectors ..........................8
Figure 13: U-Tube, Full 45° Mount...................................8
Figure 14: U-Tube, Opposite 45° Tilt ...............................9
Figure 15: U-Tube, Protective Grille.................................9
Figure 16: U-Tube, Venting ..............................................9
Figure 17: Critical Hanger Placement ...........................12
Figure 18: Linear General Assembly Overview .............14
Figure 19: Linear Layout Overview................................15
Figure 20: Double Linear General Assembly
Overview ...................................................... 17
Figure 21: Double Linear Layout Overview ................... 18
Figure 22: BLACKHEAT
Overview ......................................................27
Figure 23: BLACKHEAT
Overview ......................................................28
Figure 24: Multiburner Damper Flange Installation .......35
Figure 25: Typical Manifold Layout
(Linear and U-Tube Configuration) ...............36
Figure 26: U-tube (Horizontal).......................................48
Figure 27: U-tube (Angle Mounted)...............................48
Figure 28: Linear ...........................................................48
Figure 29: Individual Flue Connection Detail.................50
Figure 30: Flue Connection Dimensions .......................50
Figure 31: Air Supply with Flue Configurations .............51
Figure 32: Gas Connection with Stainless Steel Flex
Connector.....................................................53
Figure 33: Sequence of Operation Chart ......................57
Figure 34: Burner Cup Position.....................................60
Figure 35: BLACKHEAT
Specifications ...............................................73
®
HE U-tube Assembly
®
HE U-tube Layout
®
HE Linear and U-tube
ROBERTS GORDON® appliances have been tested and CE certified as complying with the essential requirements of the Gas Appliance Directive, the Low Voltage Directive, the Electromagnetic Compatibility Directive and the Machinery Directive for use on natural gas and LPG when installed, commissioned and maintained in accordance with these instructions.
These instructions refer to appliances designed to operate in the European Union. Appliances designed for other countries (Non-European Union) are available on request. This appliance must be installed in accordance with the local and national codes in force and used
only in a sufficiently ventilated space, as specified in these instructions. Before installation, check that the local gas distribution systems, nature of gas and pressure, and
adjustment of the appliance are compatible.
Product Approval
1 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
Logo Label
Fan/Burner Label
Bottom Panel
Rating Plate Label
Back Panel
Model No.
Serial No.
Appliance Type
Gas Pressure at Manifold
Normal Input Rating (Net Calorific Value)
Min. Input Rating (Net Calorific Value)
Country of Destination
Year of Production
Category
Orifice Size
Electrical Rating
V
Hz
W
Gas Type
Infrared Radiant Tube Heater
This applicance must be installed in accordance with the
rules in force, and used only in a sufficiently ventilated space.
Consult instructions before installation and use of this applicance.
0063
Model No.
Serial No.
Appliance Type
Gas Pressure at Manifold
Normal Input Rating (Net Calorific Value)
Min. Input Rating (Net Calorific Value)
Country of Destination
Year of Production
Category
Orifice Size
Electrical Rating
V
Hz
W
Gas Type
Infrared Radiant Tube Heater
This applicance must be installed in accordance with the
rules in force, and used only in a sufficiently ventilated space.
Consult instructions before installation and use of this applicance.
0063
Description Part Number
Logo Label 91033200 Rating Plate Label 91031300 Fan/Burner Label 91033300
SECTION 1: HEATER SAFETY
Your Safety is Important to Us!
This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and following the warnings in these sections.
Installation, service and annual inspection of heater must be done by a registered installer/contractor qualified in the installation and service of gas-fired heating equipment.
Read this manual carefully before installation, operation or service of this equipment.
This heater is designed for heating nonresidential indoor spaces. Do not install in residential spaces. These instructions, the layout drawing, local codes and ordinances, and applicable standards that apply to gas piping, electrical wiring, venting, etc. must be thoroughly understood before proceeding with the installation.
Protective gear is to be worn during installation, operation and service. Thin sheet metal parts, such as the reflector portion of the heater and the various venting components, have sharp edges. To prevent injury, the use of work gloves is recommended. The use of gloves will also prevent the transfer of body oils from the hands to the surface of the reflector.
Before installation, check that the local distribution conditions, nature of gas and pressure, and adjustment of the appliance are compatible.
The heater must be applied and operated under the general concepts of reasonable use.
For additional copies of the Installation, Operation and Service Manual, please contact Roberts-Gordon LLC.
Figure 1: Bottom and Back Panel Label Placement
1.1 Manpower Requirements
To p re vent personal injury and damage to the heater, two persons will be required for installation.
1.2 IP55 Protection
The burner is certified to protection class of IP55. This means that the internal components of the burner are protected against extreme dusty atmosphere and water jets from all sides. Outside air supply and flue are mandatory for this heater. The standard exhaust fans mentioned in this manual do NOT have IP55 protection and must be outside the wet environment. If the fan is to be installed in the wet environment, a special IP54 protected fan must be used. Consult Roberts-Gordon LLC for alternative exhaust fans. Optional stainless steel burner box provides long life in the most corrosive applications. Always ensure that the environment to be heated is not of an explosive or flammable nature. For more information, please consult your ROBERTS GORDON
®
independent distributor.
In order to have trouble free performance of your heater and maintain the IP55 protection, follow all instructions in this manual, especially the replacement of sealing gaskets.
1.3 Safety Labels and Their Placement
Product safety signs or labels should be replaced by the product user when they are no longer legible. Please contact Roberts-Gordon LLC or your ROBERTS GORDON signs or labels. See Page 2, Figure 1 through Page 3, Figure 2.
®
independent distributor to obtain replacement
2 of 73
Figure 2: Control Side Label Placement
Description Part Number
Logo Label 91033200 Wiring Diagram Label 91031404
SECTION 1: HEATER SAFETY
3 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
CAUTION
Product Damage Hazard
Do not use heater in area containing corrosive chemicals.
Refer to appropriate Material Safety Data Sheets (MSDS).
Failure to follow these instructions can result in product damage.
SECTION 2: INSTALLER RESPONSIBILITY
• To install the heater, as well as the gas and electrical supplies, in accordance with applicable specifications and codes. Roberts-Gordon LLC recommends the installer contact a local Building Inspector or Fire Marshal for guidance.
• To use the information given in a layout drawing and in the manual together with the cited codes and regulations to perform the installation.
• To install the heater in accordance with the clearances to combustibles.
• To furnish all needed materials not furnished as standard equipment.
• To plan location of supports.
• To provide access to burners for servicing on all sides, for burner removal.
• To provide the owner with a copy of this Installation, Operation and Service Manual.
• To never use heater as support for ladder or other access equipment and never hang or suspend anything from heater.
• To ensure there is adequate air circulation around the heater and to supply air for combustion, ventilation and distribution in accordance with local codes.
• To safely and adequately install heater using materi­als with a minimal working load of 33 kg.
• To ensure the heater is placed in an approved application.
2.1 Low Level User Instructions
In all situations, clearances to combustibles must be maintained. Signs should be posted in storage areas to specify the maximum stacking height of items placed below heater to maintain required clearances to combustibles. Minimum clearances must be maintained from vehicles parked below the heater. Caution should be used when running the system near combustible materials such as wood, paper, rubber, etc. Consideration should be given to partitions, storage racks, hoists, building construction, etc.
A laminated wall tag is available for the heater as a permanent reminder of the safety instructions and the importance of the required clearances to combustibles. Please contact Roberts-Gordon or your ROBERTS GORDON Affix the tag by peeling off the backing of the adhesive strips on the rear surface and position the tag on a wall near the heater (e.g. thermostat).
A copy of the wall tag (P/N 91037912) is illustrated on the back cover. This copy of the wall tag can be affixed on the wall near the heater. Know your model number and installed configuration. Model number and installed configuration are found on the burner and in the Installation, Operation and Service Manual. Write the largest clearance dimensions with permanent ink according to your model number and configuration in the open spaces on the tag.
®
independent distributor to obtain the wall tag.
2.2 Corrosive Chemicals
Roberts-Gordon LLC cannot be responsible for ensuring that all appropriate safety measures are undertaken prior to installation; this is entirely the responsibility of the installer. It is essential that the contractor, the sub­contractor, or the owner identifies the presence of combustible materials, corrosive chemicals or halogenated hydrocarbons* anywhere in the premises.
* Halogenated Hydrocarbons are a family of chemical compounds characterized by the presence of halogen elements (fluorine, chlorine, bromine, etc.). These com­pounds are frequently used in refrigerants, cleaning agents, solvents, etc. If these compounds enter the air supply of the burner, the lifespan of the heater compo­nents will be greatly reduced. An outside air supply must be provided to the burners whenever the presence of these compounds is suspected. Warranty will be invalid if the heater is exposed to halogenated hydrocarbons.
2.3 National Standards and Applicable Codes
All appliances must be installed in accordance with the latest revision of the applicable standards and national codes. This refers also to the electric, gas and venting installation. Note: Additional standards for installations in Public Garages, Aircraft Hangars, etc. may be applicable.
The heater must not be operated in environmental temperatures below 0° C.
4 of 73
SECTION 3: CLEARANCES TO COMBUSTIBLES
WARNING
Fire Hazard
Keep all flammable objects, liquids and vapors the minimum required clearances to combustibles away from heater.
Some objects will catch fire or explode when placed close to heater.
Failure to follow these instructions can result in death, injury or property damage.
SECTION 3: CLEARANCES TO COMBUSTIBLES
3.1 Required Clearances to Combustibles
Clearances are the required distances that combustible objects must be away from the heater to prevent fire hazards. Caution should be used when running the system near combustibles. Combustibles are materials that may catch on fire and include common items such as
wood, paper, rubber, fabric, etc. Maintain clearances to combustibles at all times for safety.
Clearances for all heater models are located on Page 6, Figure 3 through Page 9, Figure 16 in this manual. Check
the clearances on each burner for the model heater being installed to make sure the product is suitable for your application and the clearances are maintained. Read and follow the safety guidelines below:
• Keep petrol or other combustible materials including flammable objects, liquids, dust or vapours away from this heater or any other appliance.
• The stated clearances to combustibles represents a surface temperature of 32°C (90° F) above room tem- perature. Building materials with a low heat tolerance (such as plastics, vinyl siding, canvas, tri-ply, etc) may be subject to degradation at lower temperatures. It is the installer’s responsibility to assure that adja­cent materials are protected from degradation.
• Maintain clearances from heat sensitive equipment and workstations.
• Maintain clearances from vehicles parked below the heater.
• Maintain clearances from swinging and overhead doors, overhead cranes, vehicle lifts, partitions, storage racks, hoists, building construction, etc.
• In locations used for the storage of combustible mate­rials, signs must be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to the combustibles. Signs must be posted adjacent to the heater thermostat. In the absence of a thermostat, signs must be posted in a conspicuous location.
• Consult local Building Inspector, Fire Insurance Carrier or other authorities for approval of proposed installation when there is a possibility of exposure to combustible airborne materials or vapours.
• Hang heater in accordance to the minimum suspension requirements on Page 11, Section 5.
5 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
A
C
D
B
A
C
D
B
3.2 Clearances Data - Linear and Double Linear
NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and crosses.
2. Clearances B, C and D can be reduced by 50% after 7500 mm of tubing downstream from the burner.
3. All measurements are in millimeters.
FIGURE 3: LINEAR & DOUBLE LINEAR, HORIZONTAL MOUNTS
Model
A 150 150 150 150 150 150 200 200
B 890 970 970 1020 1170 1220 1280 1330
C 1570 1650 1650 1780 1930 1970 2010 2080
D 890 970 970 1020 1170 1220 1280 1330
HE15ST
HE30DL
HE20ST
HE40DL
HE25ST
HE50DL
HE30ST
HE60DL
FIGURE 4: LINEAR & DOUBLE LINEAR, ONE SIDE REFLECTOR
Model
A 150 150 150 150 150 150 200 200
B 230 230 230 230 230 230 230 230
C 1580 1760 1760 1930 2090 2130 2160 2240
D 1200 1380 1380 1500 1660 1710 1760 1860
HE15ST
HE30DL
HE20ST
HE40DL
HE25ST
HE50DL
HE30ST
HE60DL
FIGURE 5: LINEAR & DOUBLE LINEAR, TWO SIDE REFLECTORS
HE35ST
HE35ST
HE70DL
HE70DL
HE40ST
HE40ST
HE45ST
HE45ST
HE50ST
HE50ST
Model
A 150 150 150 150 150 150 200 200
B 590 640 640 690 820 860 890 1020
C 1660 1810 1810 1960 2110 2160 2210 2320
D 590 640 640 690 820 860 890 1020
HE15ST
HE30DL
FIGURE 6: LINEAR & DOUBLE LINEAR, 45° MOUNT
Model
A 200 200 200 250 250 275 300 300
B 200 200 200 200 200 200 200 200
C 1500 1660 1660 1860 1960 2030 2110 2160
D 1370 1520 1520 1630 1750 1820 1880 2000
HE15ST
HE30DL
HE20ST
HE40DL
HE20ST
HE40DL
HE25ST
HE50DL
HE25ST
HE50DL
HE30ST
HE60DL
HE30ST
HE60DL
HE35ST
HE70DL
HE35ST
HE70DL
HE40ST
HE40ST
HE45ST
HE45ST
HE50ST
HE50ST
6 of 73
SECTION 3: CLEARANCES TO COMBUSTIBLES
A
C
D
B
A
C
D
B
Radiant tubes
Fan
Unvented
Vented
E
F
NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and crosses.
2. Clearances B, C and D can be reduced by 50% after 7500 mm of tubing downstream from the burner.
3. All measurements are in millimeters.
FIGURE 7: LINEAR & DOUBLE LINEAR, 2 FOOT DECO GRILLE, PROTECTIVE GRILLE
Model
HE15ST
HE30DL
HE20ST
HE40DL
A 150 150 150 150 150 150 200 200
B 890 970 970 1020 1170 1220 1280 1330
C 1570 1650 1650 1780 1930 1970 2010 2080
D 890 970 970 1020 1170 1220 1280 1330
FIGURE 8 : UNDERSHIELD **
Model
A 150 150 150 150 150 150 - -
B 990 1020 1270 1270 1370 1400 - -
C 840 965 11 20 11 2 0 1220 1270 - -
D 990 1020 1270 1270 1370 1400 - -
** When installed in the first 3 m.
HE15ST
HE30DL
HE20ST
HE40DL
FIGURE 9: LINEAR & DOUBLE LINEAR, VENTING
HE25ST
HE50DL
HE25ST
HE50DL
HE30ST
HE60DL
HE30ST
HE60DL
HE35ST
HE70DL
HE35ST
HE70DL
HE40ST
HE40ST
HE45ST
HE45ST
HE50ST
HE50ST
Model
HE15ST
HE30DL
HE20ST
HE40DL
HE25ST
HE50DL
HE30ST
HE60DL
HE35ST
HE70DL
HE40ST
HE45ST
HE50ST
E 1000 1000 1000 1000 1000 1000 1000 1000
F 500 500 500 500 500 500 500 500
7 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
A
C
D
B
A
C
D
B
A
C
D
B
B
C
D
A
3.3 Clearances Data - U-Tube
NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and crosses.
2. Clearances B, C and D can be reduced by 50% after 7500 mm of tubing downstream from the burner.
3. All measurements are in millimeters.
4. Add 60 mm clearance to uncovered u-tube.
.
FIGURE 10: U-TUBE, HORIZONTAL MOUNT
Model
HE15UT
HE20UT
A 150 150 150 150 150 150 200 200
B 890 970 970 1020 1170 1220 1270 1380
C 1580 1730 1730 1910 1980 2050 2110 2210
D 760 940 940 1000 1090 1150 1200 1300
FIGURE 11: U-TUBE, ONE SIDE REFLECTOR
Model
A 150 150 150 150 150 150 200 200
B 230 230 230 230 230 230 230 230
C 1580 1760 1760 1930 2090 2130 2160 2240
D 1200 1380 1380 1500 1660 1710 1760 1860
HE15UT
HE20UT
FIGURE 12: U-TUBE, TWO SIDE REFLECTORS
HE25UT
HE25UT
HE30UT
HE30UT
HE35UT
HE35UT
HE40UT
HE40UT
HE45UT
HE45UT
HE50UT
HE50UT
Model
A 150 150 150 150 150 150 200 200
B 590 640 640 690 820 860 890 1020
C 1660 1810 1810 1960 2110 2160 2210 2320
D 590 640 640 690 820 860 890 1020
FIGURE 13: U-TUBE, FULL 45° MOUNT
Model
A 200 200 200 200 200 200 200 200
B 200 200 200 200 200 200 200 200
C 1500 1650 1650 1860 1960 2040 2110 2160
D 1070 1170 1170 1320 1550 1620 1680 1780
8 of 73
HE15UT
HE15UT
HE20UT
HE20UT
HE25UT
HE25UT
HE30UT
HE30UT
HE35UT
HE35UT
HE40UT
HE40UT
HE45UT
HE45UT
HE50UT
HE50UT
NOTE: 1. All dimensions are from the surfaces of all tubes, couplings, tees, elbows and crosses.
A
C
D
B
A
C
D
B
Radiant tubes
Fan
Unvented
Vented
E
F
2. Clearances B, C and D can be reduced by 50% after 7500 mm of tubing downstream from the burner.
3. All measurements are in millimeters.
4. Add 60 mm clearance to uncovered u-tube.
FIGURE 14: U-TUBE, OPPOSITE 45° TILT
SECTION 3: CLEARANCES TO COMBUSTIBLES
Model
HE15U
A 200 200 200 250 250 275 300 300
B 1370 1530 1530 1630 1780 1830 1880 1930
C 1500 1650 1650 1860 1960 2040 2110 2160
D 560 560 560 560 560 560 560 560
FIGURE 15: U-TUBE, PROTECTIVE GRILLE
Model
A 150 150 150 150 150 150 200 200
B 890 970 970 1020 1170 1220 1270 1380
C 1580 1730 1730 1910 1980 2050 2110 2210
D 760 940 940 1000 1090 1150 1200 1300
HE15UT
FIGURE 16: U-TUBE, VENTING
HE20UT
HE20UT
HE25UT
HE25UT
HE30UT
HE30UT
HE35UT
HE35UT
HE40UT
HE40UT
HE45UT
HE45UT
HE50UT
HE50UT
Model
HE15UT
HE20UT
HE25UT
HE30UT
HE35UT
HE40UT
HE45UT
HE50UT
E 1000 1000 1000 1000 1000 1000 1000 1000
F 500 500 500 500 500 500 500 500
9 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
Burner (shown with Tube Gasket)
Must be installed with the flame observation window facing down.
Reflector (Aluminium or Stainless Steel)
Alternate overlap as shown on overview. Minimum overlap is 160 mm.
Coupling Assembly with Lock
Reflector End Cap
Punch out center section to accommodate tube.
Fan Assembly (Includes Flange)
Fan assembly is attached to the last section of heat exchanger tubing (fan tube).
Tube and Reflector Hanger
Suspend system from these hangers.
Flex Gas Line
Tube
Heat treated aluminised tube supplied in 3000 mm lengths.
Burner Tube
Supplied in 3000 mm lengths. Burner tube is always the first tube after the burner.
Reflector Support Strap, Wire Form & #8 x 3/4 Screw
Fan Tube with Internal Swirler
Supplied in 3000 mm lengths. Fan tube is always the last tube on the heater where the fan is attached. The swirler is welded inside of the tube end.
Fan Flange Assembly and Screws
U-tube
Height Adjuster
Bow Shackle
Tee Assembly
U-tube Support Bracket
Damper Flange Assembly
For use on Multiburner Systems.
Tube and Reflector Hanger with Clamp Package
Position this hanger no more than 100 mm away from the burner assembly.
Spring Hook
S-hook
SECTION 4: MAJOR COMPONENT DESCRIPTIONS
10 of 73
SECTION 5: GENERAL SUSPENSION DETAILS
WARNING
Severe Injury Hazard
Secure burner to burner tube with bolts and lockwashers.
Hang heater with materials with a minimum working load of 75 lbs (33 kg).
Failure to follow these instructions can result in death, injury or property damage.
WARNING
Cut/Pinch Hazard
Wear protective gear during installation, operation and service.
Edges are sharp.
Failure to follow these instructions can result in injury.
SECTION 5: GENERAL SUSPENSION DETAILS
To ensure your safety, and comply with the terms of the warranty, all units must be installed in accordance with
these instructions.
The gas or the electrical supply lines must not be used to support the heater.
Do not locate the gas or electrical supply lines directly over the path of the flue products from the heater.
The heater must be installed in a location that it is readily accessible for servicing.
The heaters must be installed with clearances to combustibles as indicated on the rating plate and in this manual.
The minimum and maximum gas inlet pressures must be maintained as indicated on the rating plate. Typical installation configurations are shown on Page 12, Figure
17.
NOTE: Some models may receive S-hooks (P/N
91907302) or spring hooks (P/N 91903300), rather than bow shackles.
11 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
* Allows for thermal expansion of system.
Hanger
Side View
Front View
Hanger
Bow Shackle
I-Beam
I-Beam
Beam
Clamp
Bow
Shackle
Anchor
Concrete
Beam
Locknut
Washer
Screw Hook
min. 10 mm
Washer
Wood Beam
Turnbuckle
(not included)
600 mm
minimum*
300 mm
minimum*
10 mm
Rod
Typical Suspension Details
45° Angle
100 mm
Max.
Description Part Number
Burner Tube 03051100 S-hook 91907302 Spring Hook 91903300 Bow Shackle E0007576 Tube/Reflector Hanger 03090100
Figure 17: Critical Hanger Placement
12 of 73
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
WARNING
Cut/Pinch Hazard
Wear protective gear during installation, operation and service.
Edges are sharp.
Failure to follow these instructions can result in injury.
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
The figures in this section provide a general overview of component placement in a Linear and Double Linear system. The location of some components such as supports and couplings is crucial for proper installation. Assemble the heater components as shown on Page 14, Figure 18.
For optional reflector configurations for linear heaters see Page 6, Figure 3 through Page 7, Figure 9. Install appropriate suspension hardware, beam clamps, chain or rod at predetermined locations. Adjustments of chain length will provide uniform pitch.
If any step is unclear, please contact Roberts-Gordon LLC at +44 (0)121 506 7700.
6.1 Linear Standard Parts List
Part No. Description
033XXXXX Burner Assembly (Input and Fuel Varies) 1 1 111111
07260001 Fan Package XP 1 1 1 1 1 1 - - -
07260002 Fan Package XP 2 (optional) - -------
07260003 Fan Package XP 3 - ----111
07260051 Fan Package 1 IP55 (optional)** 1 1 1 1 1 - - -
07260052 Fan Package 2 IP55 (optional)** - -------
07260053 Fan Package 3 IP55 (optional)** - ----111
03051100Burner Tube, 100 mm x 3048 mm 11111111
91409408Tube, 100 mm x 3048 mm - 1122233
S5127WFan Tube, 100 mm x 3048 mm, with 3048 mm Swirler -1111111
S5134WFan Tube, 100 mm x 3048 mm, with 2134 mm Swirler 1-------
01329600Standard Coupling Assembly 12233344
01329700Coupling Lock 12233344
02750303Reflector, Aluminium, 2439 mm 34466677
027503SSReflector, Stainless Steel, 2439 mm (Optional)* 34466677
02750800Reflector End Cap, Aluminium 22222222
HE15ST
HE20ST
HE25ST
HE30ST
HE35ST
HE40ST
HE45ST
HE50ST
027508SHReflector End Cap, Stainless (Optional)* 22222222
03090100Tube and Reflector Hanger 34455566
01318901Tube Clamp Package (including Nut, Washer & Bolt) 11111111
91908004Wire Form 23355566
94320812 Screw #8 x 3/4, (Goes with 03050000) 4 6 6 10 10 10 12 12
03050000Reflector Support Strap 23355566
E0007576Bow Shackle*** 34455566
91107720 U-Clip Package (20 Pieces) 1 1 111111
S7199K Damper Flange Assembly (For use on Multiburner Systems) 1 Per Heater
* PVC coating must be removed prior to installation.
** If an IP55 protected fan is required, this fan replaces
07260001, 07260002, or 07260003.
*** Some models may receive S-hooks (P/N 91907302) or spring hooks (P/N 91903300), rather than bow shackles.
13 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
Vent Cap or
Bird Screen
Outside Wall
Fan Tube
Reflector
Reflector End Cap
Reflector Support
Burner
Coupling
U-Clips
Burner Tube
Tube and Reflector Hanger
Tube Clamp
Package
Fan Assembly*
(For Single Heater)
Damper Assembly
(Required for Multiburner)
*NOTE: Locate fan away from wet environment
or use the IP54 protected fan.
Fresh Air
Supply
Internal Swirler
Weld Spot
Figure 18: Linear General Assembly Overview
14 of 73
Figure 19: Linear Layout Overview
a = reflector width (not shown) - 365 mm b = end cap to burner/fan - 50 mm c = end cap to hanger - 50 mm d = distance first hanger - 2290 mm
e = distance typical between hangers - 3050 mm
f = burner height - 241 mm
g = burner length - 445 mm
Burner
Reflector
Tube
Tube/Reflector Hanger
Coupling Assembly
Fan Assembly
LEGEND
Damper Assembly
HE20ST HE25ST
c
b
de
b
e
HE30ST HE35ST HE40ST
c
b
de
b
e e
HE45ST HE50ST
c
b
de
b
e e e
g
c
b
de
b
HE15ST
f
g
f
g
f
g
f
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
Model HE15ST HE20ST HE25ST HE30ST HE35ST HE40ST HE45ST HE50ST
Reflector Overlap
700 mm 250 mm 250 mm 530 mm 530 mm 530 mm 330 mm 330 mm
(approx.)
15 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
6.2 Double Linear Standard Parts List
Part No.
033XXXXX Burner Assembly (Input and Fuel Varies) 2 2 2 2 2
07260002 Fan Package XP 2 1 1 - - -
07260003 Fan Package XP 3 1 1 1 1 1
07260052 Fan Package 2 IP55 (optional)** 1 1 - - -
07260053 Fan Package 3 IP55 (optional)** - - 1 1 1
03051100 Burner Tube, 100 mm x 3048 mm 2 2 2 2 2
91409408 Tube, 100 mm x 3048 mm - 2 2 4 4
S5127W Fan Tube, 100 mm x 3048 mm, with 3048 mm Swirler - 2 2 2 2
S5134W Fan Tube, 100 mm x 3048 mm, with 2134 mm Swirler 2 - - - -
E0009170 Tee, 100 mm x 100 mm x 100 mm 1 1 1 1 1
01329600 Standard Coupling Assembly 6 8 8 10 10
01329700 Coupling Lock 6 8 8 10 10
02750303 Reflector, Aluminium, 2439 mm 6 8 8 12 12
027503SS Reflector, Stainless Steel, 2439 mm (Optional)* 6 8 8 12 12
Description
HE30DL
HE40DL
HE50DL
HE60DL
HE70DL
02750800 Reflector End Cap, Aluminium 4 4 4 4 4
027508SH Reflector End Cap, Stainless (Optional)* 4 4 4 4 4
03090100 Tube and Reflector Hanger 6 8 8 10 10
01318901 Tube Clamp Package (including Nut, Washer & Bolt) 2 2 2 2 2
91908004 Wire Form 4 6 6 10 10
03050000 Reflector Support Strap 4 6 6 10 10
E0007576 Bow Shackle*** 6 8 8 10 10
91107720 U-Clip Package (20 Pieces) 2 2 2 2 2
E0007582 Height Adjuster 6 8 8 10 10
94320812 Screw #8 x 3/4, (Goes with 03050000) 8 12 12 20 20
* PVC coating must be removed prior to installation. ** If an IP55 protected fan is required, this fan replaces
07260001, 07260002, or 07260003.
*** Some models may receive S-hooks (P/N 91907302) or spring hooks (P/N 91903300), rather than bow shackles.
16 of 73
Figure 20: Double Linear General Assembly Overview
Vent Cap or
Bird Screen
Fresh Air
Supply
1200 mm approx.
Fan Tube
Burner
Fresh Air
Supply
Tube Clamp Package
Reflector
Reflector End Cap
Reflector Support
Coupling
Fan Assembly*
Burner Tube
Tube and Reflector Hanger
Tube Clamp
Package
U-Clips
Optional Tube Length
*NOTE: Locate fan away from wet environment
or use the IP54 protected fan.
Internal Swirler
Weld Spot
Outside Wall
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
17 of 73
BLACKHEAT® HE INSTALLATION OPERATION AND SERVICE MANUAL
Tee Assembly
Burner
Reflector
Tube
Tube/Reflector Hanger
Coupling Assembly
Fan Assembly
LEGEND
HE60DL HE70DL
c
b
de
b
e e
Repeated
Opposite
Side
HE40DL HE50DL
c
b
de
b
e
Repeated
Opposite
Side
HE30DL
g
c
b
de
b
f
Repeated
Opposite
Side
a = reflector width (not shown) - 365 mm b = end cap to burner/fan - 50 mm c = end cap to hanger - 50 mm d = distance first hanger - 2290 mm
e = distance typical between hangers - 3050 mm
f = burner height - 241 mm
g = burner length - 445 mm
g
f
g
f
Figure 21: Double Linear Layout Overview
Model HE30DL HE40DL HE50DL HE60DL HE70DL
Reflector Overlap (approx.)
700 mm 250 mm 250 mm 530 mm 530 mm
18 of 73
Step 6.3 Burner Tube Installation
Bow Shackle
Burner Tube
Hanger
2290 mm ± 250 mm
Note: Tubing requires a downward slope of 13 mm per 6000 mm away from burner.
Weld seam must be to the bottom of the tube.
Offset mounting hole must be to the top.
Description Part Number
Burner Tube 03051100 Bow Shackle E0007576 Tube/Reflector Hanger 03090100
Tube
Tube
Orient coupling so that
the impact block is in the
2:00 or 10:00 oclock
positions
Closed
Open
Tab
76 mm to 101 mm
Slide Bar
Coupling
Wide End
Coupling
Tube
Slide Bar
A
Close coupling
with tab
B
Start slide bar/coupling lock
onto coupling
C
Insert tubes into coupling
D
Tighten coupling to join tubes
Description Part Number
Coupling 01329600 Slide Bar/Coupling Lock 01329700 Tube 91409408
SECTION 6: LINEAR & DOUBLE LINEAR HEATER INSTALLATION
Step 6.4 Coupling and Tube Assembly
19 of 73
Loading...
+ 57 hidden pages