Remote Panel Descriptions
Basic Remote
This control is used for make-up air and space heating. The discharge temperature of the heater remains constant as selected on the selection dial. The burner ame is modulated by a discharge temperature control, which is governed by the remote
temperature selector.
FAN ON/BURNER ON mode: Heater can operate continuously for
building exhaust air replacement and space heating by maintaining a constant discharge temperature.
FAN ON/BURNER OFF mode: The blower can operate without the
burner for summer ventilation.
NEMA 1 enclosure.
Standard Discharge Control Remote (SDC)
This control is used for make-up air and day/night heating of the building. The discharge temperature of the heater remains constant as selected on the selection dial. The burner ame is modulated by a discharge temperature control, which is governed by the remote temperature selector.
AUTO/WINTER mode: Heater cycles on/off to maintain space
temperature as selected on the thermostat.
ON/WINTER mode: Heater can operate continuously for
building exhaust air replacement and space heating by maintaining a constant discharge temperature.
ON/SUMMER mode: The blower can operate without the
burner for summer ventilation.
NEMA 1 enclosure.
Deluxe Temperature Control Remote (DTC)
This control is used for make-up air and total automatic “day/night” heating of the building. A solid-state modulat­ing room Selectrastat fully modulates the burner ame to maintain space temperature and compensate for changing building heat losses or gains.
AUTO/WINTER mode: Occupied time: Heater can operate
continuously fully modulating Btu/h output to maintain space temperature as selected on the Selectrastat.
Unoccupied time: Heater cycles on/ off to maintain space temperature as selected on the programmable ther­mostat (night setback).
ON/WINTER mode: Heater can operate continuously fully
modulating Btu/h output to maintain space temperature as selected on the Selectrastat.
ON/SUMMER mode: The blower can operate without the
burner for summer ventilation.
NEMA 1 enclosure.
Installation Code and Annual Inspections:
All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon.
Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available
through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.
This product is not for residential use.
This document is intended to assist licensed professionals in the exercise of their professional judgement.
Roberts-Gordon, LLC
1250 William Street P.O. Box 44 Bualo, NY 14240-0044 USA Telephone: 716.852.4400 Fax: 716.852.0854 Toll Free: 800.828.7450
www.rg-inc.com
European Oce:
Roberts Gordon Europe Limited Telephone: +44 (0)121 506 7700 Fax: +44 (0)121 506 7701
© 2008 Roberts-Gordon LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems – without written permission of Roberts-Gordon LLC.
Printed in U.S.A. C2RPBNA 1008 Rev A
Loading...