Before operating this unit, please read the user manual completely and keep it. If the manual is lost,
you can send e-mail to overseas@robam.com, request for an electronic manual.
• Note to Consumer thetions wUser Guide oe r ere e
• Skill Level nishwasher rees ills Proper installation is the
responsibility of the installer. Product failure due to improper installation is not covered under the appliance
warranty.
• Completion Time
eeire
se
IMPORTANT
• Twash e installeoe re is re
•re ewasherte
contact your dealer.
FOR YOUR SAFETY
e all Wwn tions While perinstallations
es etwor
Warning
Twao heat the water To aa sert
heaen thwashe
WARNING: To ree that the ishwasher is
3
Dishwasher
READ CAREFULLY.
KEEP THESE INSTRUCTIONS.
If you have an installation problem, contact your dealer or installer. You are responsible for providing adequate electrical,
exhausting, and other connecting facilities.
Preparing to install your dishwasher
Parts supplied:
Wood screws (4)
Tools needed:
Phillips screwdriver
Flashlight
Measuring tape
Safety glasses
Top mounting clips (2)
1/4 in. and 5/16 in.
Nut driver
Gloves
Bucket
Tubing cutter
Hose clamp
Level
Adjustable wrench
New installations only
Hole saw
set
Drain hose
Carpenters
square
Drill and bits
4
Materials needed (kit purchased separately):
Dishwasher
90° Elbow, ferrule and compression nut. (3/8
NPT external thread on one end. Other end
sized to fit water supply line
New installations only
Strain relief (for
electrical
connections)
Electrical cable or power
cord (See Electrical
Requirements section)
Hot water line (min.
3/8 in. copper) kit
Not included in kit
Hand shut-off
valve
Teflon thread
seal tape
“T” connection
Screw-type hose clamps
Waste tee for
house plumbing
(if applicable)
Three wire nuts (UL listed)
(two included in kit)
Gardenhose
connection
Coupler for extending
drain line (if applicable)
Air gap (if
required)
Enclosure requirements
• The dishwasher must be installed so that the drain hose is no more than 10 feet (3.01 m) in length, for proper drainage.
• This dishwasher is designed to be enclosed on the top and on both sides by a standard residential kitchen cabinet unit.
• The installation enclosure must be clean and free of any obstructions.
• The enclosure must be at least 24 inches (61 cm) wide, 24 inches (61 cm) deep, and 34 inches (86.4 cm) high.
• For the front door of the dishwasher to be flush with the front edge of the counter top, the counter top must be 25
inches (63.5 cm) deep.
24” (61 cm)
min.
24” (61 cm)
min.
min.
34” (86.4cm)
5
Dishwasher
If installing into a corner, allow 2 in. (5.08 cm) min. clearance between dishwasher and adjacent cabinet, wall, or other
appliances. Allow 25.63 in. (65.1 cm) min. clearance from the front of the dishwasher for opening the door.
Countertop
Dishwasher
25.63”(65.1 cm)
Clearance for door opening
2” (5.08 cm) min.
Drain requirements
• Follow all local codes and ordinances.
• Do not exceed 10 ft. (3.01 m) of drain hose.
• Do not connect the drain lines from other devices to the dishwasher drain hose.
• The dishwasher must be connected to a waste line with an air gap (not provided) or a 32 in. (81.28 cm) high (min.) drain
loop, depending on local codes and ordinances, to prevent back flow into the dishwasher.
• An air gap must be used if the waste tee or garbage disposal connection is less than 18 in. (45.72 cm) above the floor, to
prevent siphoning.
Drain preparation
The type of drain installation required depends on the answers to the following questions:
• Do local codes or ordinances require an air gap?
• Will the waste tee or garbage disposal connection be less than 18 in. (45.72 cm) above the floor?
• Will installation have a drain loop less than 32 in. (81.28 cm) above the floor?
If the answer to ANY of these questions is YES, Method 1 MUST be used. Otherwise, either Method 1 or
Method 2 may be used.
Caution:
• An air gap MUST BE USED if the drain hose is connected to a waste tee or garbage disposal lower than 18 in. (45.72 cm) above the
floor.
• Failure to provide the proper drain connection height with an air gap or 32 in. (81.28 cm) (min.) high drain loop will result in
improper draining of the dishwasher.
Install the waste tee or garbage disposal connection and air gap according to manufacturer’s instructions.
6
Method 1 - Air gap with a waste tee or garbage disposal connection
Method 2 - High drain with a waste tee or garbage disposal connection
You must provide a method to attach the drain hose to the underside of the countertop.
32 in. (81.28 cm) (min.)
Dishwasher
32 in. (81.28 cm) (min.)
18 in. (45.72 cm)
18 in. (45.72 cm)
Electrical requirements
• This appliance must be supplied with 120V, 60 Hz, and it must be connected to its own, properly grounded branch
circuit that is protected by a 15 or 20 ampere circuit breaker or time delay fuse.
• Wiring must be two wire with ground.
• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
Warning:
cord or adapter plug with this appliance.
Remove the house fuse or open the circuit breaker before beginning the installation. Do not use an extension
GROUNDING INSTRUCTIONS
Grounding Instructions – Cable Direct
This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor
must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance.
Grounding Instructions – Power Cord Models
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical
shock by providing a path of least resistance for electric current. The plug must be plugged into an appropriate outlet that
is installed and grounded in accordance with local codes and ordinances.
WARNING
The improper connection of the equipment grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if you are in doubt that the appliance is properly
grounded.
Direct Wire Method
• The cable must be routed as shown in Cabinet preparation and wire routing
(60.96 cm) from the rear wall.
• Use flexible, armored, or nonmetallic sheathed, copper wire with grounding wire that meets the wiring requirements
for your home and local codes and ordinances.
• Use a UL Listed/CSA Approved strain relief.
on page 8, and extend a minimum of 24 in.
7
Loading...