Ritter 95 Owner's Manual

Cross Brace
(068-0320-00-377)
Leveling Screw - 4 pcs.
(016-1080-00)
Leg Assembly - 2 pcs.
(029-3885-00-377)
Nut (1/4”-20) - 12 pcs.
Carriage Bolt (1/4”-20 x 3 1/2”) - 12 pcs.
(Standard: 028-0641-00-xxx*)
(Cal 133: 028-0641-01-xxx*)
Screw (#8 x 3/4”)- 8 pcs.
(040-0008-46)
Washer- 8 pcs.
(045-0001-00)
Paper Roll Bracket- 2 pcs.
(053-1577-00-271)
Dowel Rod
(055-0005-00)
*Replace -xxx w/code
from Color Chart
Assembly Instructions
Step 1:
Lay table top assembly (upholstered side down), on a clean surface.
Step 2:
Secure leg assemblies with carriage bolts & nuts*. *Note: Do
not tighten nuts at this time.
Step 3:
Secure cross brace with drywall screws.
Step 4:
Tighten nuts securing leg assemblies.
Step 5:
Install four leveling screws.
Step 6:
Install paper roll brackets & dowel rod as shown. *Notes: There are pre-drilled holes at one end. Install roll brackets as shown to allow notch access for paper roll refills.
Drywall Screw (#6 x 1 1/4”)- 2 pcs.
Pre-drilled Holes
Parts Bag (029-3913-00) contains the following parts:
Leveling Feet (4pcs) Carriage Bolts (12 pcs) Drywall Screws (2 pcs) Nuts (12 pcs) Screws (8 pcs) Washers (8 pcs)
www.midmark.com: File Name
Current Color Options................004-0546-00
Notch
Access
Notch
MA74290
0i
Owner’s Guide
95 Treatment Table
Model Number: Serial Number:
Dealer Info:
Purchase Date:
Upholstery Color:
003-1649-00 Rev. K (9/30/15)
© Midmark Corporation 2006
Cleaning Periodically inspect the following:
• All fasteners must be present and secure.
• All mechanical functions should operate properly.
Cleaning
Upholstery
Wash your upholstery weekly with a mild liquid soap and water mixture, rinse with clear water and dry completely to remove disinfection cleaner build-up.
Midmark Corporation 60 Vista Drive Versailles, OH 45380 Phone: 937-526-3662 Fax: 937-526-5542 midmark.com
Leveling Feet
Paper Tear Strap
(029-0452-02)
To install paper tear strap...
Slide strap over table as shown.
To level the table..
Adjust four leveling feet as necessary.
Disinfect your upholstery with a solution of standard bleach and water mixed 1 in 10 (10%) or chlorine based cleaners. Follow this with a clear water rinse and thorough drying of material. See current CDC Guideline for Disinfection & Sterilization in Healthcare Facilities.
To minimize damage caused by disinfectant cleaner residue build-up, do not allow disinfectants to pool on the upholstery surface. Once the approved contact time has been obtained, remove and dry excess liquid remaining on the surface.
Detailed care and maintenance instructions are included with your product. This information is also available on
www.midmark.com in the Technical library under the User
Information tab for your product.
Painted Metal / Plastic Surfaces
Clean the painted metal and plastic surfaces weekly using a clean soft cloth, and mild cleaner. Periodic applications of common furniture wax will ease cleaning, and maintain the
finished luster of the surfaces.
Ordering Repair Parts
To order repair parts, contact your Midmark dealer.
To contact Midmark directly: 1-800-Midmark (1-800-643-6275)
8:00 am until 5:00 pm Mon-Fri (EST)
Important Information
Maximum Patient Weight
Max. Patient Weight ..................... 350 lbs (158.8 kg)
Warning
To avoid injury, do not put head or extremities under the paper tear strap.
SCOPE OF WARRANTY
Midmark Corporation (“Midmark”) warrants to the original retail purchaser that it will repair or replace components of the domestic and international medical products manufactured by Midmark (except for components not warranted under “Exclusions”) that are defective in material or workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement, at Midmark’s option, of the applicable components. This limited warranty shall only apply to defects that are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. This warranty extends only to the first retail purchaser of a product and is not transferable or assignable.
APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of delivery to the original user, shall be one (1) year for all warranted products and components. (A) Ultrasonic cleaner products are guaranteed for a period of two (2) years after ship date when used in accordance with manufacturer’s instructions. (B) Replacement parts and accessories carry a ninety (90) day warranty.
OBTAINING WARRANTY SERVICE Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark.com; by phone at 1-800-MIDMARK; by facsimile at 1-800-365-8631; or by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380.
It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser’s expense. It is also the retail purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this warranty.
EXCLUSIONS This warranty does not cover, and Midmark shall not be liable, for the following: (1) defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner; (2) products which are not installed, used, and properly cleaned and maintained as required in the Midmark “Installation” and/or “Installation/Operation Manual” for the applicable product; (3) products considered to be of a consumable nature; (4) accessories or parts not manufactured by Midmark; (5) charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark; (6) costs and expenses of routine maintenance and cleaning; and (7) representations and warranties made by any person or entity other than Midmark.
EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER: MIDMARK’S ONLY OBLIGATION UNDER THIS WARRANTY IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDEN­TAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR DELAYS, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS.
NO AUTHORIZATION No person or firm is authorized to create or approve for Midmark any other obligation or liability in connection with the products.
WARRANTY DISCLAIMER THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRAN­TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.
STATUTE OF LIMITATIONS No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any, or for any other claim arising out of or relating to the products, more than ninety (90) days following expiration of the limited warranty period.
Loading...