RLX94i (VC2737FFUD-US) Nat. Gas Unit
Type of Appliance
Rinnai Model Number
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Amperage
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Installation
Energy Factor
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system
Certified for installation in manufactured (mobile) homes
Forced combustion / Direct vent
Energy Star qualified
REU-VC2737FFUD-US
10,300 - 192,000 BTU/h (3.02-56.3kWh)
Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts
Normal: 97 w Standby: 2 w Anti-frost protection: 120 w
Max with pump: 8A Max without pump: 4A Fuse: 10A
Direct electronic ignition
Minimum flow rate: 0.26 GPM (1 l/min)
Minimum activation flow rate: 0.4 GPM (1.5l /min)
Maximum flow rate: 9.8 GPM (37.1 l/min)
98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable
at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with
the MCC-91-2 controller for commercial and hydronic applications
120°F (49°C) (factory default) or 140°F (60°C)
Indoor only
Natural Gas: 0.82
Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT
Hot water outlet: 3/4 inch(19mm) MNPT
Heavy duty forged brass Webstone Isolator valves EXP E2, certified to NSF/
ANSI 61-8 for potable water, rated up to 200,000BTU and 150psi
Water flow sensor, electronic water control device and by-pass
20 - 150 PSI (138-1035KPa) (recommended 30-80 PSI (207– 552KPa) for
maximum performance)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
(37.9)
10.0
FLOW TABLE
Water Flow gpm (l/min)
© 2014 Rinnai Corporation
(34.1)
9.0
(30.3)
8.0
(26.5)
7.0
(22.7)
6.0
(19.0)
5.0
(15.1)
4.0
(11.4)
3.0
(7.6)
2.0
(3.8)
1.0
0.0
25
(13.9)
delta T - Temperature Rise ºF (ºC)
RLX94i VC SP 7/2014
50
(27.8)
75
(41.6)
100
(55.6)
125
(69.4)
150
(83.3)
RLX94i (VC2737FFUD-US) Nat. Gas Unit
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
(sea level)
Manifold Gas Pressure (inches W.C.)
NOx
Simulation feed forward and feedback
MC-91-2US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-2US (optional; for hydronic and commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse
Top of heater - 6 inches (152.4mm)
Front of heater - 6 inches (152.4mm)
Sides of heater - 2 inches (50.8mm)
Top of heater - 2 inches (50.8mm)
Front of heater - 6 inches (152.4mm)
Sides of heater - 1/2 inch (12.7mm)
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Ground / bottom - 12 inches (304.8mm)
From vent pipe - 0 inches
Back of heater - 0 inches
Ground / bottom - 12 inches (304.8mm)
From vent pipe - 0 inches
Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)
Natural Gas: high fire 2.93” W.C. (7.3mbar) Low fire 0.61” W.C. (1.5mbar)
Complies with South Coast Air Quality Management District 14 ng/J or
20 ppm NOx emission levels
Limited
Warranty
DIMENSIONS
Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for
commercial; All other parts: 5 years*; Labor: 1 year;
(* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in
series with a circulation system and all circulating water flows through the water heater, and where an
on-demand recirculation system is not incorporated.)
Refer to the manual for complete warranty information.
WEIGHT: 46.3 lb (21.0 kg)
14.04 (356.6)
9.27 (235.5)
5.05 (128.1)
0.4~1.8 (10~45) Variable
2.67 (67.8)
22.95 (583)
A
B
DIMEN-
SION
A (GAS)
A (COLD)
A (HOT)
B
C
C
Inches (mm)
1.31 (33.2)
1.93 (49)
1.35 (34.4)
4.21 (106.9)
1.17 (29.8)
E
D
DIMEN-
SION
D
E
F
G
F
Inches (mm)
4.33 (110)
2.89 (73.3)
1.85 (47)
3.44 (87.3)
G
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us