Riley RC17-6500 User Manual

0 (0)

RC17-6500

Conveyor Dryer

24” wide by 8’ long conveyor dryer

Document # 16-472 Rev. P

Serial Number: _______________________________ Date: ___/___/________

(Record your machine’s serial number and date of purchase for future reference)

IMPORTANT INSTRUCTIONS:

Read all these instructions before installing or using this equipment.

All wiring to this equipment must be connected to the electrical source in strict accordance with National Electrical Code (N.E.C.) and local codes having jurisdiction.

Do Not use extension cords to power this equipment.

Before installing this equipment, the user must be aware of the safety requirements as specified by the National Board of Fire Underwriters.

CAUTION: Puncture of the element face may result in a shock hazard.

This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and away from the dryer.

Extreme caution is necessary when any dryer is used by or near children or invalids and whenever the heater is left operating and unattended.

Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.

Do not use outdoors.

To disconnect dryer, turn off power to dryer circuit at main disconnect panel.

Do not insert or allow foreign objects to enter any ventilation opening as this may cause an electric shock or fire, or damage to the dryer.

A dryer has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids are used or stored.

Use this dryer only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.

SAVE THESE INSTRUCTIONS

Assembly and Operating Instructions

RETAIN THIS MANUAL FOR FUTURE REFERENCE

Please review all of these instructions prior to assembly.

The Riley Cure-6500 is packaged in 5 cartons for shipment.

Please make sure all pieces have been received before attempting assembly.

Tools Required: One ½” wrench & needle nose pliers

Label on Box

Qty

Contents

RC17-D &

1

Drive half of Conveyor Bed, with motor

RC17-T

1

Take Up half of Conveyor Bed

 

4

Conveyor Leg Assembly

RC17-LK

2

Leg Cross Assembly

 

30

Bolts

BB08-300

1

Conveyor Belt

RC17-CP

1

Control Panel

 

1

Assembly Instructions

 

1

Heating Chamber

RC17-6500C

1

4-inch Duct Collar

2

End Shield

 

 

4

Knobs

 

4

Washers

WARNING!

Note: DO NOT plug the equipment in (or apply power) until instructed to do so.

Note: The Riley Cure-6500 requires a dedicated 208/240 Volt, 30 Amp circuit. Any attempt to operate the Riley Cure-6500 without the cord/plug provided by the manufacturer will void the warranty.

Accessories available:

BB08-HK Height Kit (Raises chamber 6”)

90-409 Motor Cord (For Control Panel Assembly Opposite Side)

Note: Portions of the assembly procedure require 2 people.

Unpack, identify, and inspect all parts. Report any missing or damaged items. Cover a 4’ x 9’ area on the floor with towels, cardboard, carpet, etc. to protect the painted parts from being scratched during assembly.

Conveyor Bed Assembly:

1.Remove (4x) bolts from RC17-LK carton.

2.Place the Conveyor Drive Assembly on the covered floor. (See Figure 1)

3.Butt the Conveyor Take-Up Assembly to the Drive Assembly. Be sure that the groove on each roller drum is on the same side of the bed.

4.Bolt the bed assembly together using (4x) bolts.

5. Fasten (4x) legs with (8x) bolts. Leave bolts loose. (See Figure 2)

Riley RC17-6500 User Manual

6.Install (2x) leg crosses to legs with (16x) bolts. (See Figure 3)

7.Tighten all bolts.

8.Using two people turn conveyor bed over onto its casters.

Loading...