Review the following safety precautions carefully before operate the instrument to
avoid any personal injuries or damages to the instrument and any products
connected to it.
To avoid potential hazards use the instrument as specified by this user’s guide only.
The instrument should be serviced by qualified personnel only.
To Avoid Fire or Personal Injury.
Use Proper Power Cord. Use the power cord designed for the instrument and
authorized in your country only.
Ground The Instrument. The oscilloscope is grounded through the grounding
conductor of the power cord. To avoid electric shock the instrument grounding
conductor(s) must be grounded properly, before making connections to the input or
output terminals of the instrument.
Connect The Probe. The probes’ ground terminals are at the same voltage level of
the instrument ground. Do not connect the ground terminals to a high voltage.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings
and marks on the instrument. Follow the user’s guide for further ratings information
before making connections to the instrument.
Do Not Operate Without Covers. Do not operate the instrument with covers or
panels removed.
Use Proper Fuse. Use the fuse of the type, voltage and current ratings as specified
for the instrument.
Avoid Circuit or Wire Exposure. Do not touch exposed connections and
components when power is on.
Do Not Operate With Suspected Failures. If suspected damage occurs with the
instrument, have it inspected by qualified service personnel before further
operations.
Provide Proper Ventilation. Refer to the installation instructions for proper
Do not operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
The disturbance test of all the models meet the limit values of A in the
standard of EN 61326: 1997+A1+A2+A3, but can’t meet the limit values
of B.
The VS5000 series Digital Oscilloscope is intended to be used for measurements in
Measurement Category I.
Measurement Category Definitions
Measurement Category I is for measurements performed on circuits not directly
connected to MAINS. Examples are measurements on circuits not derived from MAINS,
and specially protected (internal) MAINS derived circuits. In the latter case, transient
stresses are variable; for that reason, the transient withstand capability of the equipment
is made known to the user.
WARNING
IEC Measurement Category I. The HI and LO input terminals may be connected to
circuit terminal in IEC Category I installations for voltages up to 300 VAC. To avoid
the danger of electric shock, do not connect the inputs to circuit’s voltages above 300
VAC.
Transient overvoltage is also present on circuits that are isolated from mains. The
VS5000 series Digital Oscilloscopes is designed to safely withstand occasional
transient overvoltage up to 500 Vpk. Do not use this equipment to measure circuits
where transient overvoltage could exceed this level.
RIGOLVS5000 Series Digital Oscilloscopes offer good waveform view and
measurements in a compact, lightweight package. VS5000 series are ideal for
production test, field service, research and design and all of the applications
involving analog circuits test and troubleshooting, as well as education and training.
z Adjustable waveform intensity, more effective waveform view
z One-touch automatic setup for ease of use (AUTO)
z 20 Automatic measurements
z Automatic cursor tracking measurements
z Waveform recorder, record and replay dynamic waveforms
z User selectable fast offset calibration
z Built-in FFT function, Frequency Counter
z Digital filters, includes LPF, HPF, BPF, BRF
z Add, Subtract and Multiply Mathematic Functions
z Advanced trigger types include: Edge, Video, Pulse width, Slope, Alternative,
After receiving a new VS5000 series oscilloscope, please inspect the instrument as
following steps:
1. Inspect the shipping container for damage.
Keep the damaged shipping container or cushioning material until the contents of
the shipment have been checked for completeness and the instrument has been
checked mechanically and electrically.
2. Check the accessories.
Accessories supplied with the instrument are listed in "Accessories" in this guide.
If the contents are incomplete or damaged,please notify the RIGOL Sales
Representative.
3. Inspect the instrument.
In case there is any mechanical damage or defect, or the instrument does not
operate properly or fails performance tests, notify the RIGOL Sales
Representative.
If the shipping container is damaged, or the cushioning materials show signs of
stress, notify the carrier as well as the RIGOL sales office. Keep the shipping
materials for the carrier’s inspection.
RIGOL offices will arrange repair or replacement at option of RIGOL without
The first thing to do with a new oscilloscope is to become acquainted with its front
panel. This chapter will help to be familiar with the layout of the connectors,
graphical representations, interfaces, and how to use them. Read the chapter
carefully before further operations.
Figure 1-1
Front panel of VS5000 Series Oscilloscope
Figure 1-2
Rear panel of VS5000 Series Oscilloscope
VS5000 series oscilloscopes provide an easy-to-use user interface. In the main menu,
access the function options from the menu and the drop-down menu to operate
VS5000 series oscilloscope. There’re shortcuts for some common functions.
You are suggested to install the software of VS5000 and connect the equipment
when you get a new RIGOL VS5000 Oscilloscope. For more details please refer to
the following text:
Software Setting
Please insert and drive the disk accessory of the RIGOL VS5000 oscilloscope. Then,
double click the file named”
according to the hints.
Note: If you have already installed VS5000 software before, please uninstall the old
Make sure the power supply was connected correctly before using the instrument.
First, please insert power cord into the faucet of its adapter. Then connect the
adapter with oscilloscope and power on.
USB Connection
When the software setting and power supply connecting are finished, you can
connect the instrument to PC by USB cable. After connecting, a dialog about setup
will pop up to clew users to finish USB connection.
LAN Connection
A LAN port is offered at the rear panel in order to realize Remote Control which acts
a same role with USB. Besides, two steps are required to connect LAN: network
setting and connection setting.
1.Network Setting: There are two ways to config Network Protocol Property:
Obtain an IP automatically、obtain an IP manually.
(1) Obtain an IP automatically:
Please set network according to the following steps:
zConnecting: On condition that the USB cable was being connected, you can
configure l Property of Network protocol. First, connect oscilloscope to PC via
USB, and then, connect oscilloscope to LAN.
zOpen control->Network Setting, then it will pop up a dialog about configuration.
Click “obtain an IP automatically” option and press Apply to finish. .
zRestart oscilloscope and software, you can view the Property of Network
protocol in Configuration dialog box if USB communication is active.
(2) Obtain an IP manually:
zConnecting: On condition that the USB cable has being connected, you could
configure l Property of Network protocol. First, connect oscilloscope to PC via
USB, and then, connect oscilloscope to LAN.
zOpen control->Network Setting, it will pop up a dialog about configuration. Click
“obtain an IP automatically” option again to cancel Automatic setting. Then
Setting IP address、IP mask、Gateway by manual . Finally, click Apply to
configure Network protocol Property.
zRestart oscilloscope and software, you can view the Property of Network
protocol in Configuration dialog box if USB communication is active.
NOTES:
zMake sure that the oscilloscope has been connected with network through
Router in” Obtain an IP automatically”.
z Make sure the validity of IP address in ‘Obtain an IP manually’.
z Restart the oscilloscope and PC after finishing configuration.
z The function of Configure Network is invalidation in Network Communication.
2. Connection Setting:
z Connect software and oscilloscope in Network Communications.
z Select Network Communication. Open Control->Connection menu, it will pop up
a dialog, click check option LAN and select Network Communication, then set
IP address and port value to be the oscilloscope’s. Finally, click Apply to finish
connecting.
zIf communication has been found, System will clew that network connection is
successful. If failed, please check hardware connection and settings of Network
Protocol property.
NOTES:
zPlease pay attention to check the settings of Safety level of firewall when using
Network Communication.
zIn network communication, you are suggested to use “Resume default setting”
carefulness as Default connection is USB connection. Meanwhile, related result
may be brought if you cancel all the settings about Network Protocol Property.
Perform once quick check to verify the running conditions of the instrument.
1. Prepare for using the instrument.
Use the power cords designed for the oscilloscope only. Connect to a power
source that delivers 100 to 240 VAC, 45Hz to 440Hz. Power up the system,
initiate the program. Click the Storage button, select Load Default in the menu
box.
Status indicators
Channel 1, 2 and Ext Trigger
Probe compensator
Figure 1-5
Instruction of the Front Panel
2. Input a signal to a channel of the oscilloscope
VS5000 Series are equipped with dual channels plus external trigger and 16
channels logic analyzer (only for VS5000D models).
Please input signal in the light of following steps:
1) Set the attenuation switch on the probe as 10X (Figure 1-6) and connect the
probe on the oscilloscope with CH1. Aim the slot in the probe connector at the
faucet on BNC of CH1 and insert, then, turn right to lock the probe. Finally,
attach the tip of probe and ground nip to the Connector of Probe compensator.
Perform this function to match the characteristics of the probe and the channel input.
This should be performed whenever attaching a probe to any input channel at the
first time.
1. From the Probe menu, select attenuation to 1:10. Set the switch to X10 on the
probe and connect it to CH 1 of the oscilloscope. When using the probe hook-tip,
insert the tip onto the probe firmly to ensure a proper connection.
Attach the probe tip to the Probe Compensator and the reference lead to the
ground connector, select CH 1, and then press the
2. Check the shape of the displayed waveform.
Over compensated Correctly Compensated Under Compensated
button.
Figure 1-9
Instruction Waveform of Probe Compensation
3. If necessary, use a non-metallic tool to adjust the trimmer capacitor of the probe
for the flattest square wave being displayed on the oscilloscope.
4. Repeat if necessary.
WARNNING: To avoid electric shock while using the probe, be sure the
!
perfection of the insulated cable, and do not touch the metallic portions of
the probe head while it is connected with a voltage source.
1. Switch off power supply of the Device under Test if necessary to avoid short
circuit. Since no voltage is applied to the leads at this step, the oscilloscope may
remain on.
2. Connect one end of the flex cable FC1868 to the Logic Analyzer Input; connect
the other end to Logic Head LH1116. It is unnecessary to switch off power supply
of the oscilloscope while connecting the cable.
1-12
Figure 1-10
Connect the Flex Cable
CAUTION:Use only FC1868, LH1116, TC1100 and LC1150 made by
The VS5000 series oscilloscope has an automated function to display the input signal
in best fit. This feature requires a 50 Hz or higher and a duty cycle greater than 1%
input signal.
Press the
HORIZINTAL and TRIGGER controls to display the input signal. Adjust the controls
manually to get the best results if necessary.
Connect a signal to the Channel 1 (CH1) input:
1. Connect a signal to the oscilloscope as described above.
button, the oscilloscope automatically sets up VERTICAL,
2. Click the
button.
The oscilloscope may change the current settings to display the signal, i.e. the
vertical and horizontal scale, the trigger coupling, type, position, slope, level, and
mode.
ertical menu, which leads to the setting of the vertical
Figure 1-14
Vertical Menu
1. Use the Analog function in the Vertical menu to adjust the functions of the
analog channels. A voltage value is displayed for a short time indicating how far
the ground reference is located from the center of the screen. Use the left
mouse button to dragging the CH1 symbol, and/or use the Scale and Offset
options to set the scale and offset precisely.
Measurement hints
If the channel is DC coupled, measuring the DC component of the signal by
simply noting its distance from the ground symbol.
If the channel is AC coupled, the DC component of the signal is blocked,
allowing using greater sensitivity to display the AC component of the signal.