Rigol RSA3030-TG, RSA3045, RSA3030, RSA3045-TG User guide

RIGOL
User’s Guide
RSA3000 Series Real-time
Spectrum Analyzer
Jan. 16, 2018
RIGOL TECHNOLOGIES, INC.
RIGOL

Guaranty and Declaration

Copyright
© 2017 RIGOL TECHNOLOGIES, INC. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC.
Publication Number
UGD21101-1110
Software Version
00.01.00 Software upgrade might change or add product features. Please acquire the latest version of the manual from RIGOL we bsite or contact RIGOL to upgrade the software.
Notices
RIGOL produ cts are cov ered by P.R.C. and f oreign pa tents, issue d and pendin g. RIGOL reserves the right to modify or change parts of or all the specifications
and pricing policies at the company’s sole decision.
Information in this publica tion re places all previ ously relea sed materials . Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use, or performance of this manual, as well as any information contained.
Any part of th is d ocu ment is f orbi dden to be c opie d, ph oto copie d, o r rea r ran ged
without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com
RSA3000 User's Guide I
RIGOL

Safety Requirement

General Safety Summary

Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injury or damage to the instrument and any product connected to it. To prevent potential hazards, please follow the instructions specified in this manual to use the instrument properly.
Use Proper Power Cord.
Only the exclusive power cord designed for the instrument and authorized for use within the local country could be used.
Ground the Instrument.
The instrument is grounded th rou gh t he Protective Earth lead of the power cord. To avoid electric shock, con nect the earth terminal of the power cord to the Protective Earth terminal before connecting any input or output terminals.
Connect the Probe Correctly.
If a probe is used, the probe ground lead must be connected to earth ground. Do not connect the ground lead to high v olta ge. Imp roper w ay of connection could result in dangerous voltages being present on the connectors, controls or other surfaces of the oscilloscope and probes, which will cause potential hazards for operators.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all r atings an d markers on the instrume nt and check your manual for more information about ratings before connecting the instrument.
Use Proper Overvoltage Protection.
Ensure that no over voltage (su ch as that cause d by a bolt of lightni ng) can reach the product. Otherwise, the operator might be exposed to the danger of an electric shock.
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Objects Into the Air Outlet.
Do not insert objects into the air outlet, as doing so may cause damage to the instrument.
Use Proper Fuse.
Please use the specified fuses.
II RSA3000 User’s Guide
RIGOL
Avoid Circuit or Wire Exposure.
Do not touch exposed junctions and components when the unit is powered on.
Do Not Operate With Suspected Failures.
If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized personnel before further operations. Any mainte nance, adjustment or replacement especially to circuits or accessories must be p erformed by RIGOL authorized personnel.
Provide Adequate Ventilation.
Inadequate ventilation may cause an increase of temperature in the instrument, which would cause damage to the instrument. So please keep the instrument well ventilated and inspect the air outlet and the fan regularly.
Do Not Operate in Wet Conditions.
To avoid short circuit inside the instrument or electric shock, never operate the instrument in a humid environment.
Do Not Operate in an Explosive Atmosphere.
To avoid personal injuries or damage to the instrument, never operate the instrument in an explosive atmosphere.
Keep Product Surfaces Clean and Dry.
T o a void dust or moisture from af fecting the pe rformance of the inst rument, keep th e surfaces of the instrument clean and dry.
Prevent Ele c tr o static Imp a ct.
Operate the instrume nt i n an ele ctr ostatic dischar ge protectiv e e nvi ron ment to a void damage induced by static discharges. Always ground both the internal and external conductors of cables to relea s e sta t i c be fore makin g connections.
Use the Battery Properly.
Do not expose the battery (if available) to high temperature or fire. Keep it out of the reach of children. Improper change of a battery (lithium battery) may cause an explosion. Use the RIGOL specified battery only.
Handle with Caution.
Please handle with care during transportation to avoid damage to keys, knobs, interfaces, and other parts on the panels.
RSA3000 User's Guide III
RIGOL
WARNING
avoided, will result in serious injury or death.
CAUTION
avoided, could result in damage to the product or loss of important data.
DANGER
It calls attention to an operation, if not correctly performed, could result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly performed, could result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly performed, could product.
Hazardous
Voltage
Safety Warning
Protective Earth
Terminal
Chassis Ground
Test Ground

Safety Notices and Symbols

Safety Notic e s in this Manua l:
Indicates a potentially hazardous situation or practice which, if not
Indicates a potentially hazardous situation or practice which, if not
Safety Terms on the Product:
result in damage to the product o r oth er devices connected to the
Safety Symbols on the Product:
IV RSA3000 User’s Guide
RIGOL
CAUTION
WARNING
supply.

Care and Cleaning

Care
Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions.
1. Disconnect the instrument from all power sources.
2. Clean the external surfaces of the instrument with a soft cloth dampened with mild detergent or water. When cleaning the LCD , take ca re to av oid scarif ying it.
To avoid damag e t o the instrument, do not expose it to caustic liquids.
To avoid short-circuit resulting from moisture or personal injuries, ensure that the instrument is completely dry before connecting it to the power

Environmental Consideratio ns

The following symbol indicates that this product complies with the WEEE Directive 2002/96/EC.
Product End-of-Life Handling
The equipment may contain substances that could b e harmf ul to t he envi ronm ent o r human health. To avoid the release of such substances into the environment and avoid harm to human health, we recommend you to recycle this product appropriately to ensure that most materials are reused or recycled properly. Please contact your local authorities for disposal or recycling information.
RSA3000 User's Guide V
RIGOL

RSA3000 Series Overview

RSA3000 series is a new generation of cost-ef ficient real-time spectrum analyzer with high performance. With superb performance specifications and the clear user interface, the RSA3000 series allows you to oper ate it through various wa ys, s uch as pressing keys on the front panel, using the touch screen, connecting t he mouse and the keyboard. Remot e comm unication interfaces are also available. The instrument can be widely used in education science, corporate R&D, industrial production, and other fields.
Main Features:
Ultra-Real technology Frequency: up to 4.5 G H z Displayed average noise level (DANL): <-16 1 d Bm (typical) Phase noise: <-102 dBc/Hz (typical) Level measurement uncertainty: <1.0 dB 4.5 GHz tracking generator Min. RBW 1 Hz EMC filter and quasi -peak detector kit (optional) Various measurement functions Multiple measurement modes Up to 40 MHz real-time analysis bandwidth Multiple trigger modes and trigger masks Density, Spectrogram, and oth e r display modes PC software options 10.1'' capa citive multi-touch screen; supporting touch gestures USB, LAN, HDMI and other communication and display interfaces
VI RSA3000 User’s Guide
RIGOL

Document Overview

Topics in this manual: Chapter 1 Quick Start
This chapter introduces the front/rear panel and user interface as well as announcements during first use of the analyzer.
Chapter 2 Functions of the Front Panel of GPSA
This chapter gives detailed function descriptions of the GPSA's front panel keys and the associated menu keys.
Chapter 3 Functions of the Front Panel of RTSA
This chapter gives detailed function descriptions of the RTSA's front panel keys.
Chapter 4 Input/Output
This chapter introduces the parameter settings for the input/output interface.
Chapter 5 Shortcut Key
This chapter introduces the functions of the shortcut keys on the front panel.
Chapter 6 System Function
This chapter introduces the system function settings.
Chapter 7 Remote Control
This chapter shows how to control the analyzer in remote mode.
Chapter 8 Troubleshooting
This chapter lists the troubleshooting information and messages that may appear during the use of the analyzer.
Chapter 9 Appendix
This chapter lists the options and accessories that can be ordered along with your analyzer as well as the service and support information.
RSA3000 User's Guide VII
RIGOL
Model
Frequency Range
Tracking Generator
RSA3045
9 kHz to 4.5 GHz
None
RSA3030
9 kHz to 3 GHz
None
RSA3045-TG
9 kHz to 4.5 GHz
4.5 GHz
RSA3030-TG
9 kHz to 3 GHz
3 GHz
Format Conventions in this Manual:
1. Keys:
The keys on the front panel are usually denoted by the format of "Key Name (Bold) + Text Box". For example, FREQ denotes the FREQ key.
2. Menu Keys:
The menu softkeys are usually denoted by the format of "Menu Word (Bold) + Character Shading". For example, Center Freq denotes the center frequency menu item under the FREQ function key.
3. Connectors:
The connectors on the front or rear panel are usually denoted by the format of "Connector Na me (Bold) + Square B racke ts (Bold)" . For example, [ Gen Output
50Ω].
4. Operation Procedures:
"" represents the next step of operation. F or example, FREQ Center Freq indicates pressing FREQ on the front panel and the n pressi ng the menu so ftkey
Center Freq.
Content Conventions in this Manual:
The RSA3000 series spectrum analyzer includes the following models. This manual takes RSA3045-TG as an example.
User Manuals of this Product: Quick Guide, User’s Guide, Programming Guide, Data sheet, etc. For the desired manual, please download it from www.rigol.com.
VIII RSA3000 User’s Guide
Contents RIGOL
Contents
Guaranty and Declaration ......................................................................... I
Safety Requirement ................................................................................ II
General Safety Summary ........................................................................... II
Safety Not ices and Symbols ...................................................................... IV
Care and Cleaning .................................................................................... V
Environmental Considerations .................................................................... V
RSA3000 Series Overview ...................................................................... VI
Document Overview .............................................................................. VII
Chapter 1 Qui ck Start ......................................................................... 1-1
General Inspection ................................................................................ 1-2
Appearance and Dim ensions ................................................................... 1-3
To Prepare for Use ................................................................................. 1-4
To Adjust the Supporting Legs .......................................................... 1-4
To Connect to AC Pow e r .................................................................. 1-5
Turn-on Checkout ........................................................................... 1-5
Self-calibration ................................................................................ 1-5
To Set the System Language ............................................................ 1-6
Front Panel ........................................................................................... 1-7
Function Keys on the Front Pane l ..................................................... 1-8
Utility Function Keys on the Front Panel ........................................... 1-10
Front Panel Key Backlight ............................................................... 1-11
Front Panel Connector .................................................................... 1-12
To Use the Numeric Keypad ............................................................ 1-14
Rear Panel ........................................................................................... 1-16
User Interface ...................................................................................... 1-18
Mouse/Keyboard/Touch Screen Operation Rule ........................................ 1-20
Mouse Operation Rule .................................................................... 1-20
Keyboard Operation Rule ................................................................ 1-21
Touch Screen Operation Rule .......................................................... 1-22
Menu Operation ................................................................................... 1-23
Parameter Setting................................................................................. 1-25
To Use the Built-in Help System ............................................................. 1-27
Fuse Replacement ................................................................................ 1-28
Mode Setting ....................................................................................... 1-29
Mode ............................................................................................ 1-29
Mode Setup ................................................................................... 1-30
Chapter 2 Functions of the Front Panel of GPSA ................................. 2-1
Basic Settings ....................................................................................... 2-2
FREQ ............................................................................................. 2-2
SPAN ............................................................................................. 2-8
RSA3000 User's Guide IX
RIGOL Contents
AMPT ............................................................................................. 2-9
Sweep and Function Settings................................................................. 2-14
BW ............................................................................................... 2-14
Sweep .......................................................................................... 2-18
Trigger ......................................................................................... 2-22
Trace ............................................................................................ 2-26
Tracking Generator ........................................................................ 2-32
Measurement Settings .......................................................................... 2-35
Meas ............................................................................................ 2-35
Meas Setup ................................................................................... 2-38
Marker Measu re m ent ............................................................................ 2-66
Marker .......................................................................................... 2-66
Marker To ..................................................................................... 2-73
Marker Functi on ............................................................................ 2-75
Peak ............................................................................................. 2-79
Chapter 3 Functions of the Front Panel of RTSA ................................. 3-1
Basic Settings ........................................................................................ 3-2
FREQ .............................................................................................. 3-2
SPAN .............................................................................................. 3-2
AMPT ............................................................................................. 3-6
Sweep and Function Settings................................................................... 3-7
BW ................................................................................................. 3-7
Sweep ............................................................................................ 3-9
Trigger ......................................................................................... 3-11
Trace ............................................................................................ 3-16
Measurement Settings .......................................................................... 3-18
Meas ............................................................................................ 3-18
Meas Setup ................................................................................... 3-26
Marker Setup ....................................................................................... 3-33
Marker .......................................................................................... 3-33
Marker To ..................................................................................... 3-33
Marker Functi on ............................................................................ 3-33
Peak ............................................................................................. 3-33
Chapter 4 Input/Output ..................................................................... 4-1
Input Impe da nce ............................................................................. 4-1
Ext Gain ......................................................................................... 4-1
Ext Trigger2 .................................................................................... 4-1
Demod ........................................................................................... 4-2
Demod Setup .................................................................................. 4-2
Chapter 5 Shortcut Key ...................................................................... 5-1
Auto Tune ....................................................................................... 5-1
Preset............................................................................................. 5-3
User ............................................................................................... 5-9
Quick Save ...................................................................................... 5-9
X RSA3000 User’s Guide
Contents RIGOL
Cont .............................................................................................. 5-9
Single ............................................................................................ 5-9
Chapter 6 System Function ................................................................. 6-1
System .......................................................................................... 6-1
File ................................................................................................ 6-9
Recall ........................................................................................... 6-13
Save ............................................................................................. 6-15
Chapter 7 Remote Control .................................................................. 7-1
Remote Control Overview ....................................................................... 7-2
Remote Control via USB ......................................................................... 7-3
Remote Control via LAN ......................................................................... 7-4
Chapter 8 Troubleshooting ................................................................. 8-1
Chapter 9 Appendix ............................................................................ 9-1
Appendix A: RSA3000 Accessories and Option List .................................... 9-1
Appendix B: Warranty ............................................................................ 9-2
Index ....................................................................................................... 1
RSA3000 User's Guide XI
Chapter 1 Quick Start RIGOL

Chapter 1 Quick Start

This chapter gives you a quick review about the appearance and dimensions of the RSA3000 series, its front and rear panel, user interface, as well as announcements during first use of the analyzer.
Contents in this chapter:
General Inspection Appearance and Dim ensions To Prepare for Use Front Panel Rear Panel User Interface Mouse/Keyboard/Touch Screen Operation Rule Menu Operation Parameter Setting To Use the Built-in Help System Fuse Replacement Mode Setting
RSA3000 User's Guide 1-1
RIGOL Chapter 1 Quick Start

General Inspection

1 Inspect the packaging
If the packa gi ng has be en da m age d, do n ot dis po se t he da m age d pac ka gin g o r cushioning materials until the shipment has been check ed for completeness and has passed both electrical and mechanical tests.
The consigner or carrier shall be liable for the d amage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
2 Inspect the instrument
In case of any mechanical d amage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
3 Check the accessories
Please check the accessories according to the packing lists. If the ac cessor ies are damaged or incomplete, please contact your RIGOL sales representative.
1-2 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL

Appearance and Dimensions

Figure 1-1 Front View Unit: mm
Figure 1-2 Vertical View Unit: mm
RSA3000 User's Guide 1-3
RIGOL Chapter 1 Quick Start
To unfold the
To fold the

To Prepare for Use

To Adjust the Supporting Legs

You c an unfold the supporting legs to use them as stands to tilt the instrument upwards for easier operation and observation. You can also fold the supporting legs for easier storage or shipment when the instrument is not in use.
supporting legs
supporting legs
Figure 1-3 To Adjust the Supporting Legs
1-4 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
CAUTION

To Connect to AC Power

Please use the power cord provided in the acc essories to connect the spectrum analyzer to the AC power sou rce. The AC powe r supply specification of this spectrum analyzer is 100-240 V, 45-440 Hz. The power consumption of the instrument cann ot exceed 95 W. When the spectrum analyzer is connected to the AC power source via the power cord, the instrument automatically adapts to the voltage range, and you do not need to select the voltage range manually.
To avoid electric shock, ensure that the instrument is correctly grounded.

Turn-on Checkout

After connecting the instrument to the power source properly, press the Power key
on the front panel to start the spectrum analyzer. Then, you will see an initial splash screen. Following the start-up screen which shows the start-up initialization process information, the sweep curve is displayed.

Self-calibration

After the instrument starts, execute self-calibration. Press System Alignment Align Now, and then the instrument will perform self-calibration with the internal calibration source.
RSA3000 User's Guide 1-5
RIGOL Chapter 1 Quick Start

To Set the System Language

RSA3000 series spectrum analyzer supports multiple system languages. You can press System Language to switch the system language.
1-6 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
No.
Description
No.
Description
1
LCD
9
Numer ic keypad
2
Menu softkeys
10
Tracking generator output
[1]
3
Back to previous menu item
11
Utility function key area
4
Function key area
12
Page up/down key
5
Help key
13
Speaker
6
Knob
14
Earphone jack
7
Arrow keys
15
USB HOST
8
RF input
16
Power key
1 2 3
16 15 14 13 12 11 10 9 8
5
4

Front Panel

The front panel of RSA3000 is shown in the following figure.
Figure 1-4 Front Panel
Table 1-1 Front Panel Description
6
7
[1]
Note
: This function is only available for RSA3045-TG/RSA3030-TG.
RSA3000 User's Guide 1-7
RIGOL Chapter 1 Quick Start
Function Key
Description
and stop frequency; enables the s ignal tracking functi on.
trace via marker.
immediately.
value.
marker, N dB bandwidth measurement, and frequency counter.

Function Keys on the Fron t Panel

Figure 1-5 Function Keys
Table 1-2 Descriptions of Function Ke ys on the F ront P anel
Sets the parameters such as center frequency, start frequency,
Sets the frequency span of the sweep. Sets the parameters such as reference level, RF attenuator,
scale, and Y-axis unit. Enables preamp. Sets the parameters such as resolution bandwidth (RBW ) and
video bandwi dt h (VBW). Sets the parameters suc h as input impedance, external gain,
and External Trigger 2. Selects the RF calibration signal. Reads the amplitude and frequency of a certain point on the
Opens the peak search menu and searches for peaks
Sets the parameters related to trace.
Sets the parameters related to the tracking generator
[1]
.
Sets other system parameters based on the current marker
Indicates the special functions of the marker, such as noise
1-8 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
Tip:
keypad.
Sets the sweep parameters.
Sets the sweep/measurement mode to be continuous.
Sets the sweep/measurement mode to be single.
Sets the trigger source and its related parameters.
Selects the working mode of the spectrum analyzer.
Sets the parameters for the selected working mode.
Note Note
Selects and controls the measurement function
Sets the parameters
[2]
for the selected measurement function.
[2]
.
Searches for signals automatically within full frequency ra nge.
Restores the system to factory settings or user-defined state.
Sets the system parameters.
Recalls the files.
Manages the files.
Saves the files.
User-defined shortcut key.
Provides quick save function.
[1]
: This function is only available for RSA3045-TG/RSA3030-TG.
[2]
: This function is only ava ila b le for the instrument installed with RSA3000-AMK.
Click the function keypa d icon at the right corner of the LCD or finger-touch it, and then the function keypad that corresponds to the specified keys on the front panel appears. At this time, you can operate the instrument with the function
RSA3000 User's Guide 1-9
RIGOL Chapter 1 Quick Start

Utility Function Keys on the Front Panel

Table 1-3 Descriptions of Utility Function Keys on the Front Panel
Locks all the keys (exc ept the Power key) on the front panel.
Locks the touch screen of the instrument. In the multi-window display mode, press this key to select the
specif ied window to zoom it in or out. In the multi-window display mode, press this key to switch the
window.
1-10 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL

Front Panel Key Backlight

The on/off state and the color of the backlights of some keys on the front panel indicate the working state of the spectrum analyzer. The states are listed below.
1. Power Key
Flash on and off alternativ ely, in breathing state: indicates that the unit is i n
stand-by state.
Constant on: indicates that the instrument is in normal operating state.
2. Auto Tune
When you press the Auto Tune key, it is illuminated. The instrument starts sweeping within the full frequency range, searches for the signal with the maximum amplitude and moves it to the center of the screen. After the sweep is completed, the backlight turns off.
3. Tracking Generator
When the tracking generator function is enabled, the TG key is illuminated; when disabled, the backlight of the TG key is off.
4. Single
When the Single key is illuminated, it ind ic ates that the sweep/measurement mode is single.
5. Keypad Locking Key
When the backlight is on, it indicates that all the keys (except the P ower key) on the front panel is locked . Press the key a gain to unlock the f ront panel ke ys, and then the backlight of the key is off.
6. Touch Screen Locking Key
When the backlight is on, it indicates that the touch screen of the instrument is locked. Press the key again to unlock the touch screen, and then the backlight is off.
RSA3000 User's Guide 1-11
RIGOL Chapter 1 Quick Start
USB HOST
Earphone Jack
TG Output
RF Input

Front Panel Connector

Figure 1-6 Front Panel Connector
1. USB HOST
The analyzer can serve as a "master" device to connect to the external USB device. The USB storage device, mouse, and keyboard can be connected to the instrument via the interface. USB Storage Device
Reads the state file, trace+state file, measurement data file, limit line f ile, and FMT file (in RTSA mode) from the USB storage device; or stores the current instrument state, tra ce, measu rement data, limit line , or FMT to the USB storage device; or stores the contents currently displa y ed on the screen to the USB storage device in ".jpg", ".bmp", or ".png" format.
Mouse
After the mouse is properly connected to the instrument, you can use it to click on the screen to perform pa rameter setting and function configuration. For details, refer to descriptions in "Mouse/Keyboard/Touch Screen Operation Rule".
Keyboard
After the keyboard i s prop erly connected t o the instr ument, you can use t he shortcut keys on the keypad to perform the same function as what you do with the front panel keys. For details, refer to descriptions in "Mouse/Keyboard/Touch Screen Operation Rule".
2. Earphone Jack
Insert the earphone to the jac k to acquire the audio output of the demodulated
1-12 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
CAUTION
To avoid damaging your hearing, please turn the volume dow n putting on the earphone.
CAUTION
To avoid damage to the tracking generator, the reverse power cannot exceed +10 dBm when the frequency is lower than 10
should not exceed 50 V .
CAUTION
DC voltage c ompone nt and t he maxi mum con tinuou s powe r of dBm to avoid damag ing the instrument.
signal.
to zero first and then gradually turn the volume up after
3. Gen Output 50Ω
The output of the tracking generator can be connected to a receiver through a cable with an N male connector. This function is only available for RSA3045-TG/RSA3030-TG.
MHz; the reverse power cannot exceed +20 dBm when the frequency is greater than 10 MHz. The reverse DC voltage
4. RF Input 50Ω
The input terminal of the signal u nde r tes t. [RF Input 50Ω] can be connected to the device under test (DUT) via a cable with an N male connector.
For the signal inp ut to the RF input terminal, ensure that the the AC (RF) signal component do not exceed 50 V and +30
RSA3000 User's Guide 1-13
RIGOL Chapter 1 Quick Start

To Use the Numeric Keypad

The numeric keypad is available on the front panel of RSA3000, as shown in the figure below. The numeric keypad supports the Chinese characters, English uppercase/lowercase letters, numbers, and common symbols (including decimal point, space, and +/- signs), which are mainly used to edit the file/folder name and set parameters (refer to "Parameter Setting").
Figure 1-7 Numeric Keypad
The numeric keypad consists of the following parts:
1. Number/Letter
Multiplexing keys for numbers and letters. They are used to dir ectly input
the desired number or letter.
uppercase and lowercase letter in English input. This key is invalid in Chinese input.
number input and space in Chinese or English input.
2.
Press this key to inp ut a decimal point at the current cursor position in
number input.
This key is invalid in Chinese or English input.
: press this key to input 1 in number input; to switch between
is the multiplexing key for 0 and space. Press this key to inp ut 0 in
1-14 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
3.
The number input mode is , by default , selected f or para meter setting . Press
this key to input the symbol ("+" or "-"). When you press t h e key for the fi r s t tim e, the parameter symbol "-" is displayed, and when you press it again, "+" is displayed.
When you input a file or folder name, press this key repeatedly to switch
among the Chinese input, Eng lish input, and number input.
4.
When editing the parameter, press this key to exit parameter inp ut. When you edit the filename with the on-screen keyboard, pre s s this key to
hide the on-screen keyboard.
In multi-touch test, single-touch test, and keyboard test state, pre ss this
key to exit the current test state.
When the instrument is in rem ote mode, press this k ey to return to the local
mode.
5.
When editing the parameter, press this key to delete the character to the
left of the c ursor.
When editing the file name, press this key to delete t he character to the left
of the cursor.
6.
During parameter editing, pressing this key will complete the input and insert a default unit for the parameter.
RSA3000 User's Guide 1-15
13
1 2 3 4
RIGOL Chapter 1 Quick Start

Rear Panel

The rear panel of RSA3000 is shown in the following figure.
Figure 1-8 Rear Panel
1. AC Power Cord Connector
The AC power supply specification of RSA3000 is: 100-240 V; 45-440 Hz.
2. Fuse Holder
You can replace the fuse. The fuse r ating supported by the i nstrument is AC 25 0 V, T3.15 A.
3. OCXO (Option)
OCXO (Oven Cont rolled Crystal Oscillat or) c an p rovid e a hi ghly sta ble frequen cy reference over tem peratu re v ariations. F or order information of the option, ref er to the datasheet manual. Note: A 40-minute warm-up is required for OCXO to reach its nominal frequency.
4. Handle
You can rotate the handle upright and make the portable instrument easy to carry.
5. 10MHz IN
RSA3000 c an use the internal or external reference source. When a 10 MHz external clock signal is received at the [10 MHz IN]
connector, this signal is used as the external ref erence source. At this time, the status bar of the user interface displays "Ext". When the external
12 11
10 9
8 7 6 5
1-16 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
reference is lost, transfinite, or not connected, the instrument switches to the internal reference aut omatically . At this time, the icon "Ext" in the status bar of the user interface disappears.
The [10MHz IN] and [10MHz OUT] connectors are usually used to
realize synchronization among multiple instruments.
Note: When you input or disconnect an external clock signal for the first time, the network will be reconfigured.
6. 10MHz OUT
RSA3000 c an use the internal or external reference source. When the internal refer ence source is used, the [10MHz OUT] connector
can output a 10 MHz clock signal gener ated by t he analyzer. This signal can be used to synchronize other instruments.
The [10MHz OUT] and [10MHz IN] connectors are usually used to
realize synchronization among multiple instruments.
7. TRIGGER IN / OU T
Indicates the input and output terminal of Ext Trigger2. You can press Input Output Ext Trigger2 to set it to be the external trigger input interface; or
use it to synchronize the trigger output interfac es of other test devices.
8. TRIGGER IN
Indicates the input t erminal of Ext Trigger1. The Ext T rigger1 signal is sent to t he spectrum analyzer through a BNC cable.
9. LAN
Through this interface, the analyzer can be connected to your loc al network for remote control. An i ntegrated test ing system can be built quickly , as the analyzer conforms to LXI Core 2011 Device instrument standards.
10. USB DEVICE
The analyzer can serve as a "slave" device to connect to the e xternal USB device. The analyzer can be connec ted to the PC through this interface. Then, the RSA3000 series spectrum analyzer can be controlled remotely through programm i ng or the PC software.
11. USB HOST
The analyzer can serve as a "master" device to connect to the external USB device. The USB storage device, the keyboard, and the mouse can be connected to the instrument via the interface.
12. HDMI
The interface is used to connect to the display, enabling you to clearly observe the signal under test and its characteristics.
RSA3000 User's Guide 1-17
RIGOL Chapter 1 Quick Start
No.
Name
Description
1
Reference level
Displays the reference level value.
2
Measurement result
Displays the current measurement results for the results display frequency/span v alue) .
3
RIGOL
Indicates th e company logo.
4 System status
Rmt: indicates remote operation.
been enabled.
3 4 5 6 7 8 9 10 11 12
13 14
2 1
24 23 22 21 20 19 18 17 16 15
13. IF OUT
Indicates the intermediate freq uency signal in the output RF component. Its center frequency is 430 MHz.

User Interface

Table 1-4 User Interface Icons
Figure 1-9 User Interface
marker (when n o ma rker exists, the measurement
Ext: indicates the external reference. Uncal: indicates that the m easurement has not be calibrated. PA on: indicates that the preamp has been enabled. TG on: indicates that the tracking generator has
1-18 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
5
Trace indica tor
[1]
Displays information about the trace and the detector.
6
Information setting
: indicates messages, such as the prompt
has been inserted.
7
Measurement bar
Displays measurement settings.
8
Measurement function
Displays the currently selected measurement function.
9
Worki ng mode
Displays the currently selected working mode.
10
Clicks the keypad to d isplay the function keypad interface.
11
Active function area
Displays the current parameter and its value.
12
Time
Displays the system time.
13
Menu title
Displays the currently selected menu name.
14
Menu item
Displays the menu item of the current function.
15
Shows the current page and the total number of pages for the menu.
16
Sweep time and points
Indicates the sweep time and the number of sweep points in swept mode.
17
The frequency range of the current sweep channel
frequency and stop frequency.
18
Trigger level
Indicates video trigger level.
19
Indicates the readout reference and the threshold criteria for the peak
20
VBW
Indicates video bandwidth.
21
Spectrum line displ ay area
22
RBW
Indicates the resolution bandwidth.
23
The frequency range of the current sweep channel frequency and span or the combination of start
messages, alarm messages, and error messages.
: indicates the speaker. You can tune it up and down to increase and decrease the speaker volume, or set it to m ute
.
: indicates the network settings. You can
configure network parameters.
: unlocks the front panel keys; : locks the
front panel keys.
: unlocks the touch screen; : locks the touch
screen.
: indicates that no USB storage device is
inserted;
: indicates that a USB storage device
Function keypad
Menu page
Span or stop frequency
Display line
Center or start frequency
can be expressed by the combination of center frequency and span or the combination of start
Indicates the display area for the spectrum line.
can be expressed by the combination of center
RSA3000 User's Guide 1-19
RIGOL Chapter 1 Quick Start
frequency and stop fr equency.
24
Y scale
Indicates the scale indication in the Y axis.
Trace Number
Trace Type
Detector Type
[1]
Note
: The display of the trace indicator is shown in the following figure:
The first line displays the trace number. The color of the number is the same as that of
the trace.
The second line displays the trace type, including W (Clear/Write), A (Average), M
(Maximum Hold), and m (Minimum Hold). The letters with different colors and in different forms show different meanings.
The letter in blue indicates that the trace is updating. The letter in gray indicates that the trace is not updated. The letter with strikethrough and in gray color indicates that the trace will neither
be updated nor displayed.
The letter with strikethrough and in blue color indicat es t hat the trace is updating
but not displayed. It is useful in trace math operation.
The third line displays the detector type of each trace, including N (Normal, only available for
GPSA), V (Vol t a ge Average, only available f or GPSA), P (Positive Peak), p (Negative Peak), S (Sample), R (RMS Average, only available for GPSA), Q (Quasi Peak, option, only available for GPSA), and A (Average, only available for RTSA). If it shows "f", it indicates that it is math operation trace. The letter in blue in the third line (detector type) indicates that the detector is in auto state; the letter in white indicates that it is in manual state.

Mouse/Keyboard/Touch Screen Operation Rule

Mouse Operation Rule

Connect the mouse (note that only the left-click operation is supported; the scroll and right-click operations with the mo use are not supported) to the spectrum analyzer via the USB HOST interface to perform the following operations:
1. Click to select the menu and window.
2. Press and hold the left mo use button t o drag the data dis played on the g raticul e or move the slide ba r.
3. Double-click the d ata displayed on the graticule and then the data will be appeared at the right-corner.
4. Under the Marker function, you can only use the mouse to move a marker, but unable to add a marker with the mouse.
1-20 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
Front Panel Key
Keyboard Shortcut Key
[1]
Mode
Alt + o
Mode Setup
[2]
Shift + o
Meas
Alt + e
Meas Setup
[2]
Shift + e
Auto Tune
Ctrl + Alt + a
Preset
Ctrl + Alt + p
FREQ
[2]
Shift + f
SPAN
[2]
Shift + s
AMPT
[2]
Shift + a
BW
[2]
Shift + b
Trace
[2]
Shift + t
Sweep
[2]
Shift + w
Input Output
[2]
Shift + i
TG
[2]
Shift + g
Cont
F11
Marker
[2]
Shift + m
Marker ->
[2]
Shift + k
Single
F12
Peak
[2]
Shift + p
Marker Func
[2]
Shift + u
Trigger
[2]
Shift + r
System
[2]
Shift + y
File
Ctrl + f
User
Ctrl + u
Recall
Ctrl + r
Save
Ctrl + s
Quick save
Ctrl + Alt + q
Help
Alt + F1
Alt + F2
Alt + F3
Alt + F4
Alt + F5
Page Up
Page Down
11 numeric keys
Numeric keys on the keyboard: 10 numeric

Keyboard Operation Rule

Connect the keyboard to the spectrum analyzer via the USB HOST interface, and then use the shortcut keys on the keyboard to perform the same function as what you do with the fr ont panel keys.
Table 1-5 Matching Relations between the Front Panel Keys and the Keyboard Shortcut Keys
RSA3000 User's Guide 1-21
RIGOL Chapter 1 Quick Start
numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0) and a decimal point(.)
+ + -
-
Esc
Esc
Back
Backspace
Enter
Enter
Arrow keys key)
7 menu softkeys from top to bottom
F1 to F7
, , ,
(Up/Down/Left/Right arrow
[1]
Note
keyboard do not work f or t he menu operation.
Note
you're not holding down the "Shift" key. If disabled, you have to press down "Shift" and the specified letter on the keyboard at the same time to input the letter in uppercase. For example, if you want to execute the "Shift+f" shortcut key operation, you only need to press "f" on the premise that the Caps Lock key is enabled.
: Except the keyboard shortcut keys mentioned in the above table, all the other keys on the
[2]
: When the Caps Lock key is enabled, every letter you type would be in uppercase, even if

Touch Screen Operation Rule

RSA3000 has a 10.1-inch capacitive multi-touch screen that supports touch gestures.
1. When operating on the menus other than the Marker menu: Tap the trace window, then slide left and right to modify the center
frequency; slide up and down to modify the reference level.
Stretch two fingers horizontally in the trace window to decrease the span,
and pinch the fingers horizontally to increase the span. Stretc h tw o fingers in the vertical direction to decrease the Y-axis scale, and pinch the fingers vertically to increase the Y-axis scale.
2. When operating on the Marker menu: In the empty space of the scree n tr ace region , pre ss and ho ld the regi on to
add one new mark er.
Tap and hold one marker to drag the mar ker.
1-22 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL
Select the menu and use the numeric keys to modify the
press Enter to complete parameter input.
Press the corresponding menu key to switch between
Press the corresponding menu key to enter the
Press the corresponding menu key to enter the
Press the key to execute the corresponding function.
current marker.
Press the corresponding menu key and modify the
trigger. The analyzer is in Free Run state at present.

Menu Operation

There are 6 types of menus according to their operation modes. Each type of menu and its operation method are introduced below.
1. Parameter Input
value directly.
2. State Switching
3. Enter Lower-level Menu (with parameter)
For example, to modify center frequency, first select Center Freq, and then input the desired value. Then,
the sub-options. For example, press Signal Track, and then you can switch between "On" and "Off" to enable or disable the signal tracking func tion.
4. Lower-level Menu (without parameter)
5. Direct Execution
6. State Selection
lower-level menu and change the currently selected option. The parameter typ e in the u pper-level menu w ill be changed when you retur n to the upper-level menu again. For example, pre ss Y Axis Unit to enter the lower-level menu. Select dBm and then automatically return to the previous menu automatically. Then, the unit of Y-axis will be changed to dBm.
lower-level menu. For example, press Peak Config to ente r the lower-level menu directly.
For example, press Mkr->CF to set the center frequ ency of the analyzer to the frequency of the
parameters, and then go back to the previous menu. For example, press Source  Free Run to select free
RSA3000 User's Guide 1-23
RIGOL Chapter 1 Quick Start
Tip:
e the shortcut keys to perf orm the a bove men u opera tions. F or the matching
Table 1-5.
The above menu operations can be executed by touch gestures o r clicking with the externally connected mouse. Also, you can connect to the keyb oard and us relations between the front panel keys and the keyboard s hortcut keys, refer to
1-24 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL

Parameter Setting

You can enter the desired parameter values by using the nu meri c keys, the knob, or arrow keys on the front panel. Also, you can set the parameters by using the touch screen, the externally connected keypad or the mouse. This section takes an example (set the center frequency to 800 MHz) to describe six methods of parameter setting.
1. Use the numeric keys
1) Press FREQ Center Freq;
2) Input 800 by using the numeric keys;
3) Select the desired unit (MHz) from the pop-up menu.
2. Use the knob
When the parameter is editable, turn the knob clockwise to increase or counterclockwise to decrease the parameter value at the specif ied step.
1) Press FREQ Center Freq;
2) Rotate the knob until the parameter is set to the desired value (800 MHz).
Figure 1-10 Knob
3. Use the arrow keys
When the parameter is editable, use the arrow ke ys to increase or decrease the parameter value at the specific step. Note that the step sizes for the Up/Down arrow key and the Left/Right arrow key are different.
1) Press FREQ Center Freq;
2) Press the Up /Down arrow key or the Left/Right arrow key until the parameter is set to the desired value (800 MHz).
Figure 1-11 Arrow Keys
4. Use the touch screen
1) T ouch the screen to select the function keypad icon corner. Then, the function keypad is displayed. Touch "FREQ";
2) Click Center Freq;
at the upper-right
RSA3000 User's Guide 1-25
RIGOL Chapter 1 Quick Start
3) Then the numeric keypad is displayed. Input 800, and select the desired unit "MHz".
5. Use the keyboard
1) Press "Shift + f" to open the Frequency menu;
2) Press "F1" to select Center Freq;
3) Input 800 by using the num eric keys;
4) Press "F2" to select the desired unit (MHz) from the pop-up menu.
For the matching relations between the front panel keys and the keyboard shortcut keys, refer to Table 1-5.
6. Use the mouse
1) Click with the mouse to select the function keypad icon
at the upper-right corner of the screen. Then, the function keypad is displayed. Click "FREQ"
2) Click Center Freq;
3) Then the numeric keypad is displayed. Input 800, and select the desired unit "MHz".
1-26 RSA3000 User’s Guide
Chapter 1 Quick Start RIGOL

To Use the Built-in Help System

The built-in help system provides information about every function key on the front panel and every menu softkey.
1. Get the built -in help information
Press Help and a prompt message about how to obtain help inf ormation will be shown on the screen. Then, press t he key that y ou wa nt to know about it s usage, and then the relevant help information for the key will be shown on th e screen.
2. Page up/down operation
If the help information is displayed in several pages, you can press the arrow keys or use the knob to page up and down the help infor m ation.
3. Close the current help information
Press any key on the front panel to close the help information c urrently displayed on the screen. When the help information is displayed on the screen, perform any of the following operations to close the currently display ed help inf ormation dialo g box:
press Esc;  press the Help ke y ag a in; or click OK in the displayed help info rmatio n dialo g box.
4. Get the help information of the menu key
Press Help, and the help infor mation display window is displayed on the screen. Then, press the menu key and the help information of the corresponding menu item is displayed.
5. Get the help information of any function key
Press Help, and the help infor mation display window is displayed on the screen. Then, press any fun ction k ey and the correspondin g function help inf ormation i s displayed.
RSA3000 User's Guide 1-27
RIGOL Chapter 1 Quick Start
WARNING
turned off, the power source has been cut off, and the fuse to be used conforms to the fuse rating.
Fuse Holder
Fuse

Fuse Replacement

If you need to replac e the fuse, use only the specified fuse (AC 250V, T3.15A) and perform the following op erations: 1Turn o ff the instrument, cut off the power, and remove the power cord. 2Use a small straight slotted screwdriver to pry out the fuse holder. 3Take out the fuse holder. 4Replace the old fuse with a specified fuse. 5Install the fuse holder.
1-28 RSA3000 User’s Guide
Figure 1-12 To Replace the Fuse
To avoid electric shock, please ensure that the instrument has been
Chapter 1 Quick Start RIGOL

Mode Setting

Mode

Provides two working modes: GPSA and RTSA. Note: In different working modes, the functions of the keys on the front panel may
be different. Press Help to dis play the help inf o rmatio n of the current working mode. If y ou need help information for other modes, exit the help interface first. Then select the desired working mode and obtain the correspond ing help information.
1. GPSA
GPSA adopts two a nalysis methods: swept and FFT. GPSA can not only carry out frequency domain analysis, but also time domain (zero span) analysis.
Select GPSA. In this working mode, press Meas to select multiple measurements. For details, refer to Chap t e r 2.
2. RTSA
RTSA provid es the analysis function for the real-time signal, which can capture the complex signal seamlessly.
Select RTSA. Select RTSA. In this working mode, you can also press Meas to select multiple measurements. For details, refer to Chapter 3.
RSA3000 User's Guide 1-29
RIGOL Chapter 1 Quick Start

Mode Setup

The Mode Setup menu is used to set parameters global to different measurements under all working modes. These parameters are independent of the currently running measurement, and they are global to all the measurements.
Open the global parameter setting menu for the selected working mode under
Mode.
1. Global CF Mode
Turns on or off the global center frequency. In any working mode, if you enable the global center frequency, then the global center frequency will be set to the center frequency of the current mode. When you switch to a different working mode, the global center frequency will be set to the center frequency of its previous working mode. If you change the center frequency in any working mode, then the global center frequency will change with it.
2. Global CF
Sets the global center frequency. It is only available when you turns on the global center frequency.
3. Mode Preset
Resets the parameters of the current mode to be the factory default setti ng s .
1-30 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Chapter 2 Functions of the Front Panel of
GPSA
This chapter describes in d etail the function keys on the front panel and their associated menu functions in the GPSA mo de of RSA3000.
Contents in this chapter:
Basic Settings Sweep and Function Settings Measurement Settings Marker Measu re ment
RSA3000 User's Guide 2-1
RIGOL Chapter 2 Functions of the Front Panel of GPSA
start
f
stop
f
center
f
span
f
2)
(
start
stopcenter
ff
f
+=
startstop
span
f
ff
=

Basic Settings

FREQ

Sets the frequency parameters of the analyzer. The analyzer sweeps within a specif ied frequency range and restarts sweeping every time the frequency parameters are modified.
The frequency range of a channel can be expressed by either of two groups of
/
parameters: Start Frequency/Stop Frequency (
); or Center
Frequency/Span (
/
). If any of the four parameters is changed, the other
three parameters will make adjustment automatically to ensure the coupling relationship among them:
(2-1)
(2-2)
2-2 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
Fmax
[1]
/2
Range
(Smin/2)
[2]
to (Fmax - Smin/2)
Unit
GHz, MHz, kHz, Hz
Knob Step
span > 0, step = span/200 Min = 1 Hz
Left/Right Arrow Key Step Up/Down Arrow Key Step
CF step
Center Freq
Sets the center frequency (that corresp onds to the hori zontal cente r of the gr aticule ) of the current channel. Press this key or touch the s pecified menu item on the s creen to set the frequency entry mode to Center Frequency/Span. The center frequency and span values ar e respectively displayed at the lower left and right side of the graticule.
Remarks:
When you modify the center frequency, the start and stop frequency will be
modified automatically if the span remains to be unc hanged.
Modifying the center frequency indicates that the frequency is changed along
the current channel horizontally, and the ad j ustable range should be within the frequency range spec ified in the technical specifications of the analyzer.
In zero span mode, the values of start freq uency, stop frequency, and center
frequency are the same, so once one of the parameter values is modified, the other two values will b e modified automatically.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also you can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-1 Center Frequency
[1]
Note
analyzer. RSA3000 includes two models: 3 GHz and 4.5 GHz
Note
RSA3000 User's Guide 2-3
: Fmax (maximum measurement frequency) is determined by the model of the spectrum
[2]
: Smin indicates the minimum span in non-zero span.
span = 0, step = RBW/100
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
center frequency-span/2
Range
[1]
0 Hz to Fmax
Unit
GHz, MHz, kHz, Hz
Knob Step
span > 0, step = span/200 Min = 1 Hz
Left/Right Arrow Key Step Up/Down Arrow Key Step
CF step
Start Freq
Sets the start frequen cy of the current frequency cha nnel. Press this key o r touch th e specified menu item on the screen to set the frequency entry mode to Start Frequency/Stop Frequency. Th e start frequency and stop frequency values are respectively displayed at the lower left and right side of the graticule.
Remarks:
When you modify the start frequency, the span and center frequency will be
changed. The changes of span will affect other system parameters. For details, please refer to "Span".
In zero span mode, the values of start frequency, stop frequency, and center
frequency are the same, so once one of the parameter values is modified, the other two values will b e modified automatically.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also you can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-2 Start Frequency
span = 0, step = RBW/100
[1]
Note
installed, the available range is from 0 Hz to (Fmax-10 Hz).
: The range is from 0 Hz to (Fmax-100 Hz) in non-zero span. If option RSA3000-BW1 is
Stop Freq
Sets the stop frequency of the cu rrent frequen cy channel. Press this k ey or touch the specified menu item on the screen to set the frequency entry mode to Start Frequency/Stop Frequency. Th e start frequency and stop frequency values are respectively displayed at the lower left and right side of the graticule.
Remarks:
When you modify the stop frequency, the span and center frequency will b e
changed. The changes of span will affect other system parameters. For details, please refer to "Span".
In zero span mode, the values of start frequency, stop frequency, and center
frequency are the same, so once one of the parameter values is modified, the other two values will b e modified automatically.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
2-4 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
center frequency+span/2
Range
[1]
0 Hz to Fmax
Unit
GHz, MHz, kHz, Hz
Knob Step
span > 0, step = span/200 Min = 1 Hz
Left/Right Arrow Key Step Up/Down Arrow Key Step
CF step
Parameter
Remarks
Default
Fmax/10
Range
-Fmax to Fmax
Unit
GHz, MHz, kHz, Hz
Knob Step
span > 0, step = span/200 Min = 1 Hz
Left/Right Arrow Key Step Up/Down Arrow Key Step
at 1-2-5 step
to modify this parameter; also you can modify it on the touchscreen. F or detail s, refer to descriptions in "Parameter Setting".
Table 2-3 Stop Frequency
span = 0, step = RBW/100
[1]
Note
its minimum value can be set to 10 Hz.
: The range is from 100 Hz to Fmax in non-zero span. If option RSA3000-BW1 is installed,
CF Step
Changes the step size for the center frequency. Changing the center frequency by a constant step-size value switches the channel to be measured continuously.
Remarks:
Set a proper CF step value, and then select the center frequenc y. Use the
Up/Down arrow key to switch the measurement channel at a fixed step size. Thus, the instrument can sweep the adjacent channels manually.
You c an use the numeric keys, the knob, and the arrow keys on th e f r ont pan el
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-4 CF Step
RSA3000 User's Guide 2-5
span = 0, step = RBW
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
0 Hz
Range
-500 GHz to 500 G Hz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
CF step
CF Step Mode
The CF step mode consists of "Manual" and "Auto". Remarks:
In Auto mode, the CF step is 1/ 10 of the span in non-zero span mode or equals
to RBW while in zero span mode.
In Manual mode, you can use the numeric keys to set the step size.
Freq Offset
You can set a freq u ency offset value to account for frequency conversions between the device under test (DUT) and the input terminal of the spectrum analyzer.
Remarks:
The change of this parameter only changes the display values of the center
frequency, start frequency, and stop frequency; but does not affect an y hardware settings of the spectrum analyzer.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
To eliminate the frequency offset, you can set the frequency offset to 0 Hz.
Table 2-5 Freque n cy Offset
span > 0, step = full span/200
Signal Track
Enables or disables the signal tracking function. This function is used to track and measure the signal whose frequency is unstable and whose transient variation in amplitude is less than 3 dB. Place Marker1 (refer to descriptions in "Marker Measurement") onto the signal under test t o track and measure the variation of the signal. The signal track ing process is shown in the following figure:
2-6 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Start
Execute a
sweep
Search for
peak and
mark it as
Marker
Active Marker
exists?
N
Set marker
f
requency to center freq
Y
Execute the
next sweep
Search for and mark the
frequency p
oint (variation
< 3
dB
) n
ear the Marker
Remarks:
If an active mar ker currently exists, when Signal Track is enabled, the
If no marker is currently activ e, when Signal Track is enabled, the instrument will
In continuous sweep, t he system trac ks the signal continuously; in single swee p, The signal tracking function is only applicable to the swept analysis. The signal
RSA3000 User's Guide 2-7
Figure 2-1 Signal Tracking Proce s s
instrument will search fo r and mark the point (whose amplitude variation is less than 3 dB) near the mar ker. Then, set the frequency at this point to be the center frequency to keep the signal at the center of the screen.
activate Marker1, execute a peak search automatically, and set the frequency value at the current peak to be the center frequency to keep the signal always displayed at the center of the screen.
the instrument only performs a single signal track. tracking function is invalid in the following conditions:
— In zero span mode; — When the tracking generator is enabled; — When the trace is not updated; — When the continuous peak search is enabled; — In advanced me asurement mo de.
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
Fmax
Range
[1]
0 Hz, 100 Hz to Fmax
Unit
GHz, MHz, kHz, Hz
Knob Step
span > 0, step = span/200 Min = 2 Hz
Left/Right Arrow Key Step Up/Down Arrow Key Step
at 1-2-5 step

SPAN

Sets the span of the analyzer. Changing this parameter will change the frequency parameters, and after the span is changed, the sweep restarts.
Span
Sets the frequency ran ge of the current channel . Press this key or touch the specified menu item on the screen to set the frequency entry mode to Center Freque ncy/Span. The center frequency and span values are respective ly displaye d at the lower lef t and right side of the graticule.
Remarks:
When you modify the span, the start and stop frequency will be modified
automatically, with the center frequency remains to be unc hanged.
In non-zero span, the span can be set to a minimum of 100 Hz. If option
RSA3000-BW1 is installed, its minimum value can be set to 10 Hz. When the span is set to a maxim um value, the spectrum analyzer enters the full span mode.
You can set the span to 0 Hz manually; you can press the Zero Span men u item
or run the SCPI commands to enter the zero span mode.
When you modify the span in non-zero span mode, both CF step and RBW will
be changed automatically if they a re in Auto mo de. Besides, the change of RBW will change the value of VBW (in Auto VBW mode).
Any variation in span, RBW, or VBW would cause a change in the sweep time. You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-6 Span
[1]
Note
mode. If option RSA3000-BW1 is installed, the available range is from 10 Hz to Fmax in non-zero span.
: When the span of the anal yzer is set to 0 Hz, the spectrum analyzer enters the zero span
Last Span
Sets the span to the previous span setting.
2-8 RSA3000 User’s Guide
span = 0, step = 10
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Full Span
Sets the maximum span.
Zero Span
Sets the span to 0 Hz. The values of start frequency and stop frequency are the same as that of the center fr equency. The X-axis is time. The analyzer measures the time-domain characteristics of the amplitude at the center frequency point of the input signal.
Remarks:
The zero span mode disp lays the time-domain characteristics of the signal's fixed frequency components. Great differences can be found between the zero span and the non-zero span. The following func tions are invalid in zero span.
"Signal Track" under FREQ; "Mkr -> CF", "Mkr -> CF Step", "Mkr -> Start", "Mkr -> Stop", "Mkr Δ -> CF",
and "Mkr Δ -> Span" under Marker To;

AMPT

Sets the amplitude parameters of the analyzer. You can modify these parameters to make the signals under test be displayed with minimal errors in the current window, easy for you to observe .
Ref Level
Sets the maximum power or voltage that can be displayed in the current window.
Remarks:
As the RF link is limited by the max imum mixer level, when the attenuation is
reduced, the reference level will be reduced to meet the limitation of the mixer level; when the attenuation is increased, the reference level will remain unchanged.
You can use the nume ric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
RSA3000 User's Guide 2-9
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
0 dBm
Range
-170 dBm to 30 dB m
Unit
dBm, -dBm, V, mV, uV
Knob Step
In Log scale mode, step = scale/1 0 In Lin scal e mode, step = 0.1 dBm
Left/Right Arrow Key Step
Up/Down Arrow Key Step
In Log scale mode, step = scale In Lin scal e mode, step = 1 dBm
mixOffsetExtPARefmin
LLaaLATT ++=
min
ATT
Ref
L
PA
a
Ext
a
Offset
L
mix
L
Parameter
Remarks
Default
10 dB
Range
0 dB to 50 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dB
Table 2-7 Reference Level
Attenuation
Sets the RF front-end attenuator to allow high-level signals t o pass throu gh the mixer with low distortion, and low-level signals to pass through the mixer with low noise.
Remarks:
The attenuator consists of fixed attenuator and variable attenuator. The
attenuation of the fixed attenuator is 20 dB, and the attenuation range of the variable attenuator is from 0 dB to 30 dB. Therefore, the input attenuation ranges f rom 0 dB to 50 dB.
When the set attenuation amount is greater than 20 dB, fixed attenuator is
preferred to be used by default.
When the maximum mix er level and reference level a re confirmed, the minimum
of the input attenuation should meet the following equation:
(2-3)
Wherein,
,
input attenuation, reference level, PA, external gain, reference level offset, and maximum mixer level, respectively.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-8 Input Attenuation
2-10 RSA3000 User’s Guide
,
,
,
, and
indicate the minimum
Preamp off, step = 1 dB
Chapter 2 Functions of the Front Panel of GPSA RIGOL
×=
0.001W
1
R
2
Volts
10lgdBm
 
 
=
V1
Volts
20lgVdB
µ
µ
 
 
=
1mV
Volts
20lgdBmV
R
2
Volts
Watts =
R
Atten Auto
Selects "Manual" or "Auto" to be the current attenuation mode.
Remarks:
To select "Manual" to be the attenuation mode, press Attenuation to set the
attenuation value, and the attenuation mode will be automatically switched to "Manual".
When you select "Auto" to be the attenuation mode, the attenuator will
automatically adjust the attenuation value to meet the current amplitude setting.
RF Preamp
Sets the RF front-end preamplifier to be on or off. When the signal under test is a low-level signal, turning on the preamplifier can reduce the displayed average noise level, so that you c an distinguish low-level signals from the noise. By default, the preamp gain is 2 0 dB.
Y Axis Unit
Sets the unit of the Y -a xis to dBm, dBmV, dBuV, Volts, or Watts. Wherein, dBm, dBmV, and dBuV are for Log scale; Volts and Watts are for Linear scale. The default unit is dBm.
Remarks:
The conversion relations between units are as follows:
(2-4)
(2-5)
(2-6)
(2-7)
Wherein,
denotes the reference resistance.
RSA3000 User's Guide 2-11
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10 dB
Range
0.1 dB to 20 d B
Unit
dB
Knob Step
scale ≥ 1, step = 1 dB scale < 1, s t e p = 0.1 dB
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-2-5 step
Scale Type
Sets the scale type of the Y-axis to Lin or Log. By default, it is Log.
Remarks:
In Log scale type, the Y-axis denotes the logarithmic coordinate. The top line of
the graticule is the reference level, and the scale per division represents the scale value. When the scale type is changed from Lin to Log, the unit of Y-axis will automatically switch to the default unit (dBm) in Log scale type.
In Lin scale type, the Y-axis denotes the linear coordinate. The to p line of the
graticule is the reference level, and 0 V is at the bottom of the graticule. Each vertical division of the g rat icule rep resents one-tenth of the refe rence level. Th e scale setting function is in v alid. When the scale t ype is change d from Log to Li n, the unit of Y-axis will automatically switch to the default unit (Volts) in Lin scale type.
The scale type does not affect the unit of Y-axis. If the "Normalize" func tion is enabled, "Log" is selected to be the sc ale type by
default, and the scale type is grayed out and disabled.
Scale/Div
Sets the logarithmic unit s per vertical grid division on the display. This function is only available when the scale type is set to "Log".
Remarks:
The amplitude range to be displayed can be adjusted by setting the scale. The range of the signal amplitude that can be displayed is as follows:
Minimum: reference level – (10 × cur rent scale value) Maximum: reference level
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-9 Scale
2-12 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
-10 dBm
Range
-50 dBm to -10 dBm
Unit
dBm, -dBm, mV, uV
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dBm
Parameter
Remarks
Default
0 dB
Range
-300 dB to 300 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dB
Max Mixer Lvl
Sets the maximum input level of the mixer according to the amplitude of the signal.
Remarks:
For the high-level input si gnal, select a smaller ma ximum mi xer leve l to in crease
the input attenuation and reduce the distortion of the signal; for the low-level input signal, select a l arger maximum mixer level to reduce t he input at tenuation and noise.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. For details, refer to descriptions in "Parameter Setting".
Table 2-10 Maximum Mixing Level
1 dBm
Ref Offset
Adds an offset value to the reference level to compensate for gains or losses generated between the DUT and the analyzer input.
Remarks:
The offset value does n ot aff ect the tr a ce posit ion, but will modif y the ref e rence
level readout and the marker amplitude readout.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-11 Reference Level Offset
1 dB
RSA3000 User's Guide 2-13
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
3 MHz
Range
[1]
10 Hz to 3 MHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-3-10 step

Sweep and Function Settings

BW
Sets the parameters such as RBW (Resolution Bandwidth) and VBW (Video Bandwidth).
RBW
Sets the resolution bandwidth (RBW) to distinguish two signals whose frequencies are close with each other.
Remarks:
Reducing RBW can gain a higher frequen c y resolut ion, but will also prolong the
sweep time (when sweep time is set to Auto, it will be affected by both RBW and VBW).
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Note: When "Detector Type" is "Quasi Peak", or the "Filter Type" is "EMC", the available values of RBW can only be 200 Hz, 9 kHz, 120 kHz, or 1 MHz.
Table 2-12 RBW
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 1 Hz to 10 MHz.
RBW Mode
Sets the coupling mode of RBW.
Remarks:
When you set RBW Mode to "Auto", RBW is in auto coupling state. Its value
changes with the sp an (non-zero span), and the value is determined by span/RBW ratio. You can set RBW Mode to "Manual" or directly set the RBW value to change the coupling mode.
When you perform the Preset operatio n, the coupling state is Auto.
2-14 RSA3000 User’s Guide
at 1-3-10 step
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
106
Range
2 to 10,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-2-5 step
In zero span mode, RBW Mode is, by default, set to "Manual".
SPAN/RBW Ratio
Sets the ratio of span to RBW . You can use the numeric keys, the knob, and the arrow keys on the front panel to modify this parameter; also you can modify it on the touchscreen. For details, refer to descriptions in "Parameter Setting".
Table 2-13 Span/RBW Ratio
at 1-2-5 step
SPAN/RBW Mode
Sets the coupling mode of the Span/RB W ratio.
Remarks:
When you set SPAN/RBW Mode to "Auto", "SPAN/RBW Ratio" is in auto
coupling state, and its value is 106. You can set SPAN/RBW Mode to "Manua l" or directly set the SPAN/RBW ratio to change the coupling mode.
When you perform the Preset operation, the coupling state is Auto. In zero span mode, the SPAN/ R BW Mode m enu item c annot be set.
RSA3000 User's Guide 2-15
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
3 MHz
Range
1 Hz to 10 MHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-3-10 step
VBW
Sets the video ba ndwidth (VBW) to filter out the noises outside the video band.
Remarks:
Reducing VBW makes the spectral line smoother, so that the low-level signal i n
the noise can be detected, but this will also prolong the sweep time (when sweep time is set to A uto, it will be affected by both RBW and VBW).
You c an use the numeric keys, the knob, and the arrow keys on the front pane l
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-14 VBW
at 1-3-10 step
VBW Mode
Sets the coupling mode of the Span/RBW ratio.
Remarks:
When you set VBW Mode to "Auto", VBW is in auto coupling state. I ts value
changes with the RBW, and the value is determined by VBW/RBW ratio. You can set VBW Mode to "Manual" or directly set the VBW value to change the coupling mode.
When you perform the Preset operation, the coupling state is Auto.
VBW/RBW Ratio
Sets the ratio of VBW to RBW.
Remarks:
This value is different for different kinds of signals.
Sine signal: 1 to 3 (for faster sweeps) Pulse signal: 10 (to reduce the impact on the amplitude of transient signals) Noise signal: 0.1 (to obtain the average of noises)
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
2-16 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
1
Range
0.00001 to 3,000,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-3-10 step
Table 2-15 VBW/RBW Ratio
at 1-3-10 step
VBW/RBW Mode
Sets the coupling mode of the VBW/RBW ratio.
Remarks:
When you set VBW/RBW Mode to "Auto", "VBW/RBW Ratio" is in auto
coupling state, and its value is determined by auto rule value. You can set VBW/RBW Mode to "Manual" or directly set the VBW/RBW ratio to change the coupling mode.
When you perform the Preset operatio n, the coupling state is Auto.
Filter Type
Sets the type of the RBW filter.
Remarks:
RSA3000 supports two kinds of RBW filters: Gaussian (-3 dB) or EMC (-6 dB) When EMC filter is selected currently, the available RBW can only be 200 Hz, 9
kHz, 120 kHz, or 1 MHz.
By default, the analyzer uses the Gaussian filter. If the detector type is
"Quasi-peak", then the analyzer automatically switches to EMI filter.
RSA3000 User's Guide 2-17
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
801
Range
101 to 10,001
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5

Sweep

Sets sweep-related parameters, such as sweep time, sweep points, and sweep mode.
Sweep Points
Sets the number of points acquired in each sweep, i.g. the num b er of the trace points.
Remarks:
With the increase of the sweep points, the frequency resolution of the marker
will increase with it, but the sweep speed will decrease with it.
Due to the limitation of the minimum i nterval of sweep poi nts, when the number
of sweep points is increased , the sweep time will be prolonged.
Changing the number of the swe ep p oint s wi ll affect multiple parameters of the
system. Therefore, the system will make a new sweep and measurement again.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also you can modify i t on t he touchs creen. Fo r details, refer to descriptions in "Parameter Setting".
Table 2-16 Number of S weep Points
1
Sweep Time
Sets the time required for the spectrum analyzer to complete one sweep operation within the span rang e.
Remarks: You can use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
When RBW is smaller than 1 kHz, the spectrum analyzer starts to perform FFT
sweeps. At this time, the Sweep Time menu is disabled and grayed out.
2-18 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
1 ms
Range
[1]
1 μs to 6,000 s
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Table 2-17 Sweep Time
sweep time/100, Min = 1 μs
[1]
Note
: The range is from 1 ms to 4,000 s in non-zero span.
Sweep Time Mode
Sets the "Sweep Time" to be "Auto" or "Manual". By default, it is "Auto".
Remarks:
In non-zero span mode, the analyzer selects the shortest sweep time based on
the current RBW and VBW settings if "Auto" is selected.
Decreasing the sweep time can speed up the measurement. However, an erro r
may be caused if the set sweep time is less than the minimum sweep time in Auto coupling. At this point, "UNCAL" is shown in the status bar on the screen.
In zero span mode, the Sweep Time Mode menu is disabled and grayed out.
When the system exits the zero span mode, the auto sweep coupling mode will restore to its previous state.
When RBW is smaller than 1 kHz, the spectr um analyzer star ts to per form FFT
sweeps. At this time, the Sweep Time menu is disabled and grayed out.
Sweep Time Rule
Sets the sweep type to "Norm" or "Accy". The sweep will be faster if "Norm" is selected; while in "Accy" type, a higher measurement precision can be obtained. When RBW is smaller than 1 kHz, the spectr um analyzer star ts to per form FFT sweeps. At this time, the Sweep Time menu is disabled and grayed out.
Continue
Sets the sweep mode to be continuous.
Remarks:
If the instrument is in single sweep mode and no measurement function is
enabled, press this key to enter continuous sweep mode. In this case, if the trigger conditions are met, the instrument will sweep continuously.
If the instrument is in single sweep mode and the measurement function is
RSA3000 User's Guide 2-19
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Enter continuous sweep mode and
wait for trigger condition
Sweep again and wait for trigger
condition
Select “Cont
Single sweep status
Y N
enabled, press this key to enter continuous sweep mode. In this case, if the trigger conditions are met, the instrument will sweep continuously.
In continuous sweep mode, the system will send a trigger initialization signal
automatically and enter the trigger condition jud gment directly after e ach sweep is completed.
Figure 2-2 Process of Continuous Sweep
Single
Sets the sweep mode to be single. Selects "Single", and then the Single key on the front panel is illuminated. In single sweep mode, press Single under Sweep menu or press Single directly on the front panel to perform one measurement.
Remarks:
If the instrument is in conti nuous sweep mode and no measurement function is
enabled, press this key to enter single sweep m ode. In this case, if the trigger conditions are met, the instrument will e xecute the specified number of sweeps. (Note: In A verage, Max Hold, a n d Min Hold modes, when performing the single measurement, the instrument will not stop sweeping until the sweep count has reached N. Wherein, N is determined by the average count of the current measurement.)
If the instrument is in cont inuous sweep mode a nd the meas urement fun ction is
enabled, press this key to set the measurement mode to "Single". In this case, if the trigger conditions are met, the instru ment will e xecute the specified number of measurements.
If the system is already in single sweep mode, press this key and then the
system will execute the specif i ed number of sweeps (or measurements) once the trigger conditions are met.
In single sweep mode, trig ger initialization (press Sweep Single or send the
2-20 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Press
“Single
Measurement
s
tatus
?
Single s
weep mode? Single
sweep mode
?
Enter s
ingle sweep mode
and w
ait for trigger
c
ondition
Enter
single sweep
/
measurement
mode and
w
ait for trigger
condition
Sweep again and wait
for
trigger condition
Wait for trigger
condition
and make
single
m
easurement again
N
N
N
Y
Y
Y
":INIT" command through the remote interface) should be executed before judging the trigger conditions.
Figure 2-3 Process of Single Sweep
RSA3000 User's Guide 2-21
RIGOL Chapter 2 Functions of the Front Panel of GPSA

Trigger

Selects the trigger source and sets trigger-related parameters.
Trigger Source
Sets "Free Run", "External 1", "External 2", or "Video" to be the trigger source.
1. Free Run
The trigger conditions are met at any time, that is, the analyzer generates trigger signals continuously.
2. External 1
In this mode, an external signal is input via the [TRIGGER IN] conne ctor on the rear panel. When the s ignal mee ts the s et trigger conditions, trigger signals are generated.
3. External 2
Press Input Output Ext Trigger2 to select "In". Then, an exte rnal si gnal is input via the [TRIGGER IN/OUT] connector on the rear panel. When the signal meets the set trigger c o nditions, trigger signals are generated.
Note: For the external tr igger interface, the input signal frequency shall not exceed 1 MHz.
4. Video
A trigger signal will be generated when the system detects a video signal whose voltage exceeds the specified vid eo trigger level.
Note: This trigger type is available in either of the following conditions:
1) in non-zero span mode
2) when "Average(RMS)" or "Average(V ol)" is selected for the detector type.
Slope
Sets the trigger polarity for External Trigger. It is set positive to trigger on a rising edge and negative to tr igger on a falling edge.
Trigger Delay Switch
Enables or disables the trigger delay function. After t he trigger delay function is enabled, you can set the trigger delay time.
2-22 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
1 μs
Range
0 μs to 500 ms
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Parameter
Remarks
Default
-25 dBm
Range
-140 dBm to +30 dBm
Unit
[1]
dBm
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10 dBm
Trig Delay
Sets the time interval during which the instrument waits to start t he sweep oper ation after the trigger signal that meets the trigger conditions is generated. You can use the numeric keys, the k nob, and the arrow keys on the front panel to modify this parameter; also you c an modify it on the touchscreen. For details, refer to descriptions in "Parameter Setting".
Table 2-18 Trigger Delay
trigg er delay/10 0, Min = 1 μs
Trigger Level
Sets the trigger level in video trigger. At this time, the trigger level line and the trigger level value are displayed on the screen.
Remarks:
When the video trigger signal is not within the display range, the trigger level
line is displayed at the top or bottom of the waveform display area.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also y ou can modify it on the touchscreen. F or details, refer to descriptions in "Parameter Setting".
Table 2-19 Trigger Level
[1]
Note
: It is related to the specified unit of Y-axis.
Trigger Holdoff Switch
Turns on or off the trigger holdoff function.
RSA3000 User's Guide 2-23
1 dBm
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
100 ms
Range
100 μs to 500 ms
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Parameter
Remarks
Default
100 ms
Range
1 ms to 100 s
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Trigger Holdoff
Sets the holdoff time between trigger signals. You can use the numeric keys, the knob, and the arr o w keys on the front panel to modify this parameter; also you can modify it on the tou chs c reen. For details, refer to descriptions in "Parameter Setting".
When the trigger conditio ns a re met, the trigge r o ccurs. T hen , the delay begin s, and the holdoff time begins. D uring the holdoff time, ne w tri gge r signals will be ignored. For a f ree-running tri gger, the holdoff value is the minimum time between two trigger signals.
Table 2-20 Trigger Holdoff Time
sync hold off time/100, Min = 1 μs
Auto Trig Switch
Enables or disables the auto trigger function.
Auto Trig
Sets the time that the instrument will w ait for the tri gger conditi ons to be met. Whe n the set waiting time times out, the instrument will not wait and start to initiate the sweep measurement.
Table 2-21 Auto Trigger Time
The relationship among the r elevant parameters concerning trigger is shown in the following figure.
2-24 RSA3000 User’s Guide
auto tr igger time/ 100, Min = 1 μs
Chapter 2 Functions of the Front Panel of GPSA RIGOL
trigger s ignal
triggers on the rising edge
trigger delay
trigger occurs
trig holdoff
au t o trig
… …
… …
trigger occurs
trigger delay
sweep
measurement1
sweep
measurement2
(turn off trigger dela y)
trigger occurs trigger occurs
Figure 2-4 Trigger Parameter Relationship
RSA3000 User's Guide 2-25
RIGOL Chapter 2 Functions of the Front Panel of GPSA

Trace

Displays the sweep signal on the screen. Press Trace to set parameters for trace.
Trace Selection
RSA3000 c an display at most 6 traces sync hronously. Each trace is indicated in different colors (T r a ce1-yellow, Trace2-dark blue, Trace3-green, Trace4-purple, Trace5-light blue, T r ace6-orange). For deta il s , re fer to the notes about "trace indicator" in "User Interface".
Select the corresponding trace to set the relevant parameters for the specified trace. By default, Trace1 is selected, and the trace type is "Clear Write".
Note: The trace currently displayed on the screen can be saved to the internal or external memory. If needed, you can recall it at any time. Press Save to save it according to descriptions in "Save".
Trace Type
Sets the type of the currently selected trace. The system calculates the sampled data by a specific operation method according to the selected trac e type. The results will not be displayed unless you set "Tra ce Update" and "Trace Display" to "On". Trace types include Clear Write, Average, Max Hold, and Min Hold.
1. Clear Write
Sets the trace data to a minimum value, and displays the real-time sweep data of each point on the trace.
2. Average
Displays an average trace, which is represented by averaging the data of eac h point on the trace. The type of the trace is displayed to be smooth.
3. Max Hold
Maintains and displays a max hold trace, which represents the maximum data value on a point -by-point basis. When a new maximum value is generated, data will be updated, and the newly updated maximum value prevails.
4. Min Hold
Maintains and displays a min hold trace, which represents the minimum data value on a point-by-point basis. When a new minimum value is generated, data will be updated, and the newly updated minimum value prevails.
2-26 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
=
×=
N
iRMS
v
N
V
1i
2
1
RMS
V
i
v
R
R
v
P
RMS
2
=
Detector Type
Sets the detector for the current measurement. The selected detector can be applied to the selected trace. The available trace detectors include Pos P eak, Neg Peak, Normal, Sam pl e , Average (RMS), and Average (Vol).
1. Pos Peak
For each tr a ce point , P ositi ve P eak detecto r dis plays t he maximum v alue o f data sampled within the corresponding time interval.
2. Neg Peak
For each trace point, Negative Peak detector displays the minimum value of data sampled within the corresponding time interval.
3. Normal
Normal detector (also called Rosenfell detector) displays the maximum value and the minimum value of the sample data segment in alternating sequence. That is, for an odd-numbered data point, the minimu m val ue of the sample data is displayed; for an even-numbered data point, the maximum value of the sample data is displayed. I n this way, the amplitude variation range of the signa l is clearly shown.
4. Sample
For each trace point, sample detector displays the transient level c or resp on ding to the central t ime poi nt of t he corresponding time interv al. This detector type is applicable to noise or noise-like signal.
5. Average (RMS)
For each data poi nt, perf o rm mea n s qua re root ope ration (see equation (2-8) of the sampled data within the corresponding time interval and display the result. In this type, noise c an be rejected and weak signals can be c learly observed.
(2-8)
Wherein, the number of sampled values for each point displayed;
the sampled value, expressed in V. Reference impedance calculate power based on the formula:
is the root mean square value of voltage, expressed in V ; N is
is the envelope of
can be used to
.
6. Average (Vol)
For each data point, perform arithmetic averages (see equation below) on all the sampled data within the corresponding time interval and display the result.
RSA3000 User's Guide 2-27
RIGOL Chapter 2 Functions of the Front Panel of GPSA
=
×=
N
i
AV
v
N
V
1i
1
AV
V
N
i
v
(2-9)
Wherein,
is the average of voltage in V;
values for each point displa yed; and
is the envelop of the s ampled value in V.
is the number of sampled
7. Quasi Peak (Option) Quasi-peak detection is a weighted form of peak detection. For each dat a poi nt, the detector detects the peak in the corresponding time interval, and uses quasi-peak detector circuit (containing specific charge and discharge structure) and the time constants specified in CISPR Publication 16 to make weighted calculation to display the weighted results. The quasi-peak detection is used for EMC test.
Note: The charge tim e fo r the quasi-detector is much shorter than the discharge time, which can not only reflects the amplitude of the signal, but also the time distribution of the signal.
Detector Auto
Enables or disables the Detector Auto fun ction. By def ault, Detector Auto is enabled. If you set the detector type manually, please disable the Detector Auto function.
Trace Update
Enables or disables trace update.
Trace Display
Enables or disables the trace display.
Remarks:
The trace state and the parameter settings for the corresponding state are as
follows:
Active: Trace Update and Tra ce Display are "On". Vi ew: Trace Update is "Off", and Trac e Display is "On". Clea r : Trace U pd ate a nd Trac e Disp l ay are "Off". Back-end: Trace Update is "On", and Trace Display is "Off ".
In most cases, the inactive trace data keep unchanged. However, the data may
be changed in the following conditions: Remotely write data into trace;
2-28 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
)1010log(10Trace
10)(Op210)(Op1
result
=
)10
10log(10Trace
10)
(Op210)
(Op1
result
+
=
OffsetOp1Trace
result
+=
Load the stored data to trace.Trace data are cleared by the trace clear function.
When inactive trace is displa yed, the tra ce will not be zoomed in or out base d on
the setting of X-axis, but will move up and down based on the changes of Y-axis values.
When the trace is shifted from inactive to active state, the trace is cleared, the
average timer is reset, and a new sweep is r esta r ted .
Math Function
Trace math functions perform mathematical operations between traces and, in some cases, use r -defined offsets.
1. Op1-Op2
Calculates the power diff eren ce betw een O per and 1 (O p1) a nd Ope ran d 2 (Op2 ), and saves it to the destination trace. D urin g t he sw eep, the following formula is executed for each point:
(2-10)
In the above formula, the parameter unit is dB. If a point in Op1 is a maximum trace value, the difference (the result of the subtraction) is also a maximum trace value; if the difference is less than or equal to 0, the resultant point is the minimum trace value.
2. Op1+Op2
Calculates the power sum between Operand 1 (O p1) a nd O perand 2 (Op2), an d saves it to the destination trace. During the sweep, the following formula is executed for each point:
(2-11)
In the above for mula, the parameter unit is dB. If a point in Op1 or Op2 is a maximum trace value, the sum (the result of addition) is also a maximum trace value.
3. Op1+Offset
Calculates the sum betwe en Opera nd 1 (Op1) a nd the offset, an d saves it to the destination trace. During the sweep, the following formula is executed for each point:
(2-12)
In the above formula, the parameter unit is dB.
4. Op1-Offset
Calculates the difference betwee n Operand 1 (O p1) and the offset (Offset), and saves it to the destination trace. During the sweep, the following formula is executed for each point:
RSA3000 User's Guide 2-29
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Offset
Op1Trace
result
=
ReferenceOp2Op1Trace
result
+= -
(2-13)
In the above formula, the parameter unit is dB.
5. Op1–Op2+Ref
Operand 1 (Op1) minus Operand 2 (Op2), and then plus the referenc e (Reference). Then, saves the result to the destination trace. During the sweep, the following formula is executed for each point:
(2-14)
In the formula, the unit for Op1, Op2, and Reference is dBm.
6. Off Disables the math function.
Note: The trace math functions are mutually exclusive. If you apply one math operation to a certain trace, the last selected math operation function should be disabled.
Op1
Selects Operand 1 to b e used for the trace math functions. Operand 2 can be conf igured with Trace1, Trace2, Trace3, Trace4, Trace5, or Trace6.
Op2
Selects Operand 2 to b e used for the trace math functions. Operand 2 can be conf igured with Trace1, Trace2, Trace3, Trace4, Trace5, or Trace6.
Note: The currently display trace does not involve in math operation.
Offset
Sets the log offset in the math operation function. The unit is dB. Note: This menu is only valid when you select "Op1+Offset" or "Op1-Offset" to be the math type.
2-30 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
0 dB
Range
-100 dB to 100 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10 dB
Parameter
Remarks
Default
0 dB
Range
-170 dB to 30 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dB
Table 2-22 Offset
1 dB
Reference
Sets the log reference d ifference in the math operatio n function. The unit is dBm. Note: This menu is only valid when you select the "Op1-Op2+Ref" operation
function. Table 2-23 Reference
1 dB
Preset All
T urns on Trace 1, and blanks all other tr aces. This operation does not affe ct the trace type, trace detector, and other states.
Clear All
Clears all traces. All the tra ce data will be set to the minimu m t race value (exc ept the case that the trace is in Min Hold state). When the trace is in Min Hold state, the trace data will be set to the maximum trace value. That is, even if you turn off the trace update, the trace data will be updated after you perform the "Clear All" operation.
RSA3000 User's Guide 2-31
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
-40 dBm
Range
-40 dBm to 0 dBm
Unit
dBm, -dBm, mV, uV
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10 dBm

Tracking Generator

Sets the parameter related to the tracking generator (TG). This function is only available for RSA3045-TG/RSA3030-TG.
Tracking Generator
Enables or disables the tracking generator. When the tracking generator is enabled, a signal with the same frequency as that of
the current sweep signal will be output from t he [GEN OUTPUT 50Ω] connector on the front panel. The power of the signal can be set through the menu.
Amplitude
Sets the output power of the tracking generator signal. You c an use the numeric keys, the knob, and the arrow keys on the front p anel to modify this param eter; also you can modify it on the touchscreen. For details, refer to descriptions in "Parameter Setting".
Table 2-24 Tracking Generator Output Signal Amplit ude
1 dBm
Amplitude Offset
Sets the offset of the output power of the tracking generator when gains or losses occur between the TG output and external device, so as to display the actual power value.
Remarks:
This parameter only chang es the readout of the t racking generator output power ,
rather than the actual output power.
The offset could be either a positive (gain in the external output) or a negative
(loss in the external output) value.
You c an use the numeric keys, the knob, and the arrow keys on the front panel
to modify this parameter; also you can modify it on the touchscreen. F or detail s, refer to descriptions in "Parameter Setting".
2-32 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
0 dB
Range
-200 dB to 200 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10 dB
Parameter
Remarks
Default
0 dB
Range
-200 dB to 200 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10 dB
Table 2-25 Tracking Generator Output Amplitude Offset
1 dB
Normalize
Before enabling the normalize function, connect the tracking generator output terminal [Gen Output 50Ω] to the RF input terminal [RF Input 50Ω]. Normalization can eliminate the er ror of tracking generator output amplitude.
Note: Only when Output under the TG menu is "On" and the current Y-axis scale is log, can the Normalize menu be enabled.
1. Normalize
Enables or disables the nor malize function. If no saving operation is performed on the reference tra ce before enabling the normalize fun ction, the next time you enable the function, the analyzer will save the reference trace automatica lly after it completes the current sweep. During saving the reference trace, a prompt message will be displayed. When the normalize functio n is enabled, the corresponding value of the reference trace will be subtracted from the trace data after every sweep.
2. Reference Level
After the normalize func tion is enabled, you can adjust the vertical position of the trace on the screen by adjusting the reference level. Differen t fro m t he Ref Level sub-menu under AMPT, the parameter
"Reference Level" under "Normalize" will not affect the referenc e level of the analyzer once it is modified.
You c an use the numeric keys, the knob, and the arrow keys on the front
panel to modify this parameter; also you can modify it on the touchscreen. For detail s , refer to descriptions in "Parameter Setting".
Table 2-26 Normalization Reference Level
RSA3000 User's Guide 2-33
1 dB
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
100%
Range
0% to 100%
Unit
%
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
10%
3. Reference Position
After the normalize func tion is enabled, you can adjust the vertical position of Reference Level on the screen by adjusting the referen ce position. The function of this menu is s imilar to that of Refe rence Level. W hen it is set
to 0%, Referenc e Level is displayed at the bottom of the graticule and at the top line of the graticule when it is set to 100%.
You c an use the numeric keys, the knob, and the arrow keys on the front
panel to modify this parameter; also you can modify it on the touchscreen. For details, refer to descriptions in "Parameter Setting".
Table 2-27 Tracking Generator Ref ere nce Position
1%
4. Reference Trace
Sets whether to display the reference trace. If you set "Refer ence Trace" to be "On", the reference trace saved ( Trace 6) wil l be shown .
5. Save Ref Trace
Saves the data of Trace1 to Trace6 as the reference value f or normalization. This operation should be done before you enab le the normalize function.
2-34 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL

Measurement Settings

Meas

Provides swept SA and VS WR, as wel l as mult iple ad v ance d measure ment f unc tions, including time-domain power, adjacent channel power, multi-channel power, occupied bandwidth, emission bandwidth, C/N ratio, harmonics, and TOI.
Swept SA
Measures with swept analysis (frequency-domain), FFT analysis (f requency-domain), or zero span analysis (time-domain). After you select Swept SA, the advanced measurement function (AMK) is off by default. Press Meas Setup to set the corresponding parameters for swept SA.
Advanced Measurement Function (AMK)
This function is an option for RSA3000, and the function is only available when the advanced measurement kit (AMK) is installed. When you enable the measur ement function, the screen is divided into two windows, with the upper wind o w (the basic measurement window) displaying the sweep trace and the lower window displaying the measurement results.
1. Meas Off
Disables the advance measurement function and returns to the swept SA interface in GPSA mode.
2. T-Power
The system enters the zero s pan mode an d calculate s the p ower within the tim e domain. The available power types include Peak, Average, and RMS. Select T-Power and then pr e ss Meas Setup to set the corresponding parameters.
3. ACP
Measures the power of the main channel, the power of adjacent channels, and the power difference between the main channel and each of the adjacent channels. When this function is enabled, the sp an and resolution bandwidth of the analyzer will be adjusted to smaller values automatically. Select ACP and then press Meas Setup to set the corresponding parameters.
4. Multichan Pwr
Measures the power and power density of multiple channels or that of the specif ied channel bandwidth. When this function is enabled, the span and
RSA3000 User's Guide 2-35
RIGOL Chapter 2 Functions of the Front Panel of GPSA
resolution bandwidth of the analyzer will be adjusted to smaller values automatically. Select Multichan Pwr and then press Meas Setup to set the correspondin g parameters.
5. Occupied BW
Integrates the power within the whole span and then calculates the bandwidth occupied by this power according to the specified power ratio. The OBW function also indicates the d ifference (namely "Transmit Freq Error") between the center frequency of the c hannel and the center frequency of the analyzer. Select Occupied BW and then press Meas Setup to set the corresponding parameters.
6. Emission BW
Measures the bandwidth between two points on the signal which a re X dB below the highest point within the span. Selects Emission BW and then press Meas Setup to set the correspondin g parameters.
7. C/N Ratio
Measures the power of the carrier and that of the noise with the specified bandwidth, as well as their power ratio. Select C/N Ratio and then press Meas Setup to set the correspondi ng parameters.
8. Harmo D ist
Measures the power of each order of harmonic and THD (total harmonic distortion) of the carrier. The highest or der of harmonics f or measu rement is 1 0. The fundamental harmoni c a mplitude of the carrier signal must be greater than
-50 dBm; otherwise the measurement will be invalid. Select Harmo Dist and then press Meas Setup to set the corresponding parameters.
9. TOI
Measures the third-order intercept (TOI) of a two-tone signal (with the same amplitude and similar frequency), including the frequencies and amplitudes of Lower Ton e , Upper Tone, Lo w e r 3rd TOI, and Upp er 3rd TOI, as we l l as the intercept points of both the Lower 3rd TOI and Upper 3rd TOI. Select TOI and then pres s Meas Setup to set the correspondin g parameters. Restart
2-36 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
VSWR
Enables or disables the VSWR measurement function. When the VSWR measurement function is enabled, the user interface is divided into tw o sections automatically (the lower section provides the measurement wizard). At this time, you c an perform the VSWR measurement accord ing to the wizard. Press Meas Setup to set the corresponding parameters.
Tip:
The VSWR bridg e and track ing gener ator are required in VSWR measurement. Therefore, this function is only available for RSA3045-TG/RSA3030-TG installed with VSWR bri dge. When the VSWR measurement is enabled, the tracking generator is enabled automatically, and the backlight of TG on the front panel turns on.
RSA3000 User's Guide 2-37
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
100
Range
1 to 10,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
k
NewdataOldAvg1)(k
NewAvg
+×
=
k
10101)(k
10log
NewAvg
10
Newdata
10
OldAvg
+×
=

Meas Setup

Open the parameter setting menu of the function selected in the Meas menu.
Swept SA
1. Avg Number
Specif ies the number of counts (N) for Average, Max Hold, and Min Hold. Fo r Average, the greater the value of N, the smoother the trace is displayed. In Average, Max Hold, and Min Hold modes, when p erforming the single measurement, the instrument stops sweeping after the sweep count has reached N.
Table 2-28 Swept SA Average Count
1
2. Avg Mode
The average modes include "Log", "RMS", and "Scalar". Log: In this mode, all filtering and averaging processes select the log unit
(dB). This average type is the most effective one for finding the low-level signal that is close to the noise amplitude. The formula is shown as follow:
(2-15)
In the above formula, the parameter unit is dB.
RMS: In this mode, all filtering and averaging proce sses work on the power
(the square of the amplitud e) of the signal. This average type is best for measuring the true time average power of complex signals. The formula is shown as follows:
(2-16)
In the above formula, the parameter unit is dB.
Scalar: In this mode, all filtering and averaging processes work on the
voltage envelope of the signal. This average type is the most appropriate one for observing the great enve lope fluctuations of AM or pulse-modulated signals such as radar and TDMA transm itters. The formula is shown as follows:
2-38 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
k
10101)(k
20log
NewAvg
20
Newdata
20
OldAvg
+×
=
(2-17)
In the above formula, the parameter unit is dB.
3. Avg State
Enables or disables the auto average function. When the auto average function is enabled, the instrument will select the best a vera ge type base d on the current settings. When you select one of the ave rage types manually , t he instrument will apply the selected ty pe, and the auto ave rage functi on is disabled a utomaticall y.
4. Limit
Sets the parameters of limit lines. After you press Preset, the limit line measurement function is disabled, but the data of the limit lines will be reserve d. The limit line data will only be deleted when the loading mode is Default. When you exit the measurement mode, the limit line data will not be deleted.
1) Test Limits
Selects whether the displayed traces are tested against the corresponding limit lines. For ea ch display ed trace, the corresponding limit li ne is turned o n, and a message will be displayed at the upper-left corner of the trace to indicate whether the test p asses or fails.
2) Select Limit
Selects the current limit line. By default, it is L imit1.
3) Limit State
Enables or disables the displa y of the limit line. When the limit line is on , the measurement interface dis plays t he l imit l ine, an d t he c orres ponding tra ces are tested based on the current limit lines. Each limit line is displayed in a different color.
4) Edit Limit
When "Display State" of the limit line is set to "On", this menu is valid. When you press this key to enter the editing menu, open the limit editing window. Then , the cu rrent limit line will be turne d o n. Close the peak ta ble, and open the trace that corresponds to the limit line.
Type: Selects the type of the current limit line to be "Upper" or
"Lower". If the trace amplitude is greater than the amplitude of the upper limit line and smaller than that of the lower limit line, then the test fails.
X To CF: When "Fixed" is selected, the frequency of the current editing
point will not be affec ted by the center frequency. When "Relative" is selected, the frequency of the current editing point is the difference between the frequency of the point and the current center frequency. At this time, if the center frequency changes, then the position of the
RSA3000 User's Guide 2-39
RIGOL Chapter 2 Functions of the Front Panel of GPSA
current editing point changes along with the center frequency.
Y To Ref: When "Fixed" is selected, the amplitude of the current
editing point will not be affected by the reference level. When "Relative" is selected, the amplitude of the current editing point is the difference between the amp litude of the point and that of the current reference level. At this time, if the reference level changes, then the position of the current editing point changes along with the reference level.
Margin State: Enables or disables the display of the margin. When
you enable the display of the margin, the measurement interface displays the margin lines; when you disable the display of the margin, the margin is invalid.
Margin: Sets the margin for the current limit line. Navigation: Selects the first line of the limit line table. Frequency: Edits the frequency of the current point. When R el F req is
selected, edit the frequency difference between the frequency of the current point and the center frequency.
Amplitude: Edits the a mplitude of t he current point. If the Rel Ampt is
enabled, edit the amplitude difference between the amplitude of the current point and the reference level.
Append Point: Inserts an edit point.Delete Point: Deletes the point that you are editing. Build From: Sets a trace for building the limit line. The range is from
Trace1 to Trace6.
Build: Builds the limit line according to the selected trace. Copy From: Copies the selected limit line into the current limit line.
The range is from Limit1 to Limit6.
Copy: Performs the limit line copy operation. X Offset: Se t s t he frequency offset of the current limit line. Y Offset: Sets the amplitude offset of the current limit line. Apply Offset: Adds th e X and Y offsets to each point of the current
limit line, then resets the X and Y offset values to 0.
Tip: You c an touch any point in the trace d isplay window on the screen to edit the current point to be the limit line data point. You can also drag the point to adjust the position of the current edit point, that is, to chang e the frequency/amplitude of the current point.
5) Test Trace
Sets the trace for the current limit line test.
6) Delete Limit
Deletes the currently selected limit line. The data of the current limit line will be cleared and they will be restored to factory defaults.
2-40 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
7) Deletes A l l L imits
Deletes all limit lines. After you press the menu , t he data of all the li mit lines will be cleared and they will be restored to factory defaults.
5. Auto Couple
When you enable "Auto Couple" function, all the manual/auto settings in the current measurement mode will be set t o "Auto". This operation does not affect other measurement modes. In auto state, the auto c oupled parameters are changed with their coupled parameters. The auto cou pling oper ation will ensu re the optimal perfor mance of the instrument. After the o p eration, all the auto coupled parameters will immediately be automatically reset based on the coupled par amet ers.
6. Meas Preset
Restores all parameters of the current measurement mode to their factory default values.
RSA3000 User's Guide 2-41
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10
Range
1 to 1,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
Measurement Result Measurement Parameters
Start Line Stop Line
Time-domain Power (T-Power)
Measurement Interface:
Figure 2-5 T-Power Measurement Interface
Measurement Result: T-power, i.g. the power of the signal fr om the start line to
stop line. Measurement Parameters: average count, average mode, av er age auto, p ower
type, start line, and stop line.
1. Avg Number
Specif ies the number of times for averaging the measurement results. You can use the numeric keys, the knob, or arrow k eys to modify this para meter; you ca n also use the touch screen to modify the parameter.
Table 2-29 Average Count of T-Power Measurement
1
2-42 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
0 μs
Range
0 μs to (current value of stop line)
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
2. Avg Mode
Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is sel ected, t he result is the e x ponential a ver age of the
measurement results obtained in the past N times (N is specified in "Avg Number").
When "Repeat" is selected, the result is the arithmetic average of the
measurement results obtained in the past N times (N is specified in "Avg
Number").
3. Avg State
Selects whether to auto averaging the measurement results. By default , it is s et to "On".
4. TP Type
Peak
Displays the power of the signal (with the maximum amplitude) between the start line and stop line. The detector type is set to "Pos Peak" automatically.
Average
Displays the average power of signals between the start line and stop line. The detector type is set to "Voltage Avg" automatically.
RMS
Displays the root mean square value ( expressed in W) of the voltages of signals between the start line and stop line. The detector type is set to "RMS Avg" automatically.
5. Start Line
Sets the left margin (in time unit) of T-Power measurement. The calculation range for the data of T-Power measurement is from the start line to the stop line. You can use the numeric keys, the knob, or arrow k eys to modif y this par ameter; you can also use the touch screen to modify the parameter.
Table 2-30 Start Line for T-Power Measurement
6. Stop Line
Sets the right margin (in time unit) of T-Power measurement. The calculation range for the data of T-Power measurement is from t he start line to the sto p line.
RSA3000 User's Guide 2-43
sweep time/600, Min = 1 μs
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
1 ms
Range
current value of start line to current value of sweep time
Unit
s, ms, μs, ns, ps
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
You can use the numeric keys, the knob, or arrow k eys to modif y this par ameter; you can also use the touch screen to modify the parameter.
Table 2-31 Stop Line for T-Power Measurement
sweep time/600, Min = 1 μs
7. Auto Couple
When you enable "Auto Couple" function, all the manual/auto settings in the current measurement mode will be set to "Auto". In auto state, the auto c oupled parameters are changed with their coupled parameters. The auto cou pling oper ation will ensu re the optimal perfor mance of the instrument. After the o peration, all the auto coupled parameters will immediately be automatically reset based on the coupled parameters.
8. Meas Preset
Restores all parameters of the current measurement mode to their factory default values.
2-44 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Main Channel Bandwidth
Adjacent Channel
Channel Spacing
ACP
Measurement Interface:
Bandwidth
Figure 2-6 Adjacent Channel Power Measurement Interface
Measurement Results: main channel power, upper-adjacent channe l pow er, and lower-adjacent channel power. Main channel power: displays the p ower within the bandwidth of the main
channel.
Upper: displays the power of the upper channel and the power diff erence
between the upper channel and the main channel (in dBc).
Lower: displays the power of the lower channel and the power difference
between the lower channel and the main channel (in dBc).
Measurement Parameters: average cou nt, average mode, auto avera ge, main channel bandwidth, adjacent channel bandwidth, and channel spacing.
1. Avg Number
Specif ies the number of times for averaging the measurement results. You can use the numeric keys, the knob, or arrow k eys to modify this para meter; you ca n also use the touch screen to modify the parameter.
RSA3000 User's Guide 2-45
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10
Range
1 to 1,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
Parameter
Remarks
Default
2 MHz
Range
[1]
33 Hz to 1.5 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Table 2-32 Average Count of ACP Measurement
1
2. Avg Mode
Sets the average mode to "Exponential" or "Repeat". The default average type is "Exponential". When "Exponential" is sel ected, t he result is the e x ponential a ver age of the
measurement results obtained in the past N times (N is specified in "Avg Number").
When "Repeat" is selected, the result is the arithmetic average of the
measurement results obtained in the past N times (N is specified in "Avg
Number").
3. Avg State
Selects whether to averaging the measurement results. By default, it is set to "On".
4. Main Chan BW
Sets the bandwidth of the m ain channel, and the power of the main c hannel is the power integral within this bandwidth. You can use the numeric keys, the knob, or arrow k eys to modify this parameter; you can als o use the touch scree n to modify the parameter.
Table 2-33 Main Channel Bandwid th for ACP Measurement
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 3 Hz to 1.5 GHz.
5. Adj Chan BW
Sets the frequency width of the adjacent channels. The adjacent channel bandwidth is related to the main channel bandwidth,
and the settable rang e is from (main channel bandwidth/20) to (main channel bandwidth x 20).
You c an use the numeric keys, the knob, or arrow keys to modify this
2-46 RSA3000 User’s Guide
main channel bandwidth/100, Min = 1 Hz
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
2 MHz
Range
[1]
33 Hz to 1.5 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
adjacent channel bandwidth/100, Min = 1 Hz
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Parameter
Remarks
Default
2 MHz
Range
[1]
33 Hz to 1.5 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
parameter; you can also use the touch screen to modify the parameter.
Table 2-34 Adjacent Channel Bandwidth for ACP Measurement
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 3 Hz to 1.5 GHz.
6. Chan Spacing
Sets the spacing between the center f reque nc y of t he main channel and that of the adjacent channels. Adjusting this parameter will also adjust the distance between the
upper/lower channel and the main channel.
You c an use the numeric keys, the knob, or arrow keys to modify this
parameter; you can also use the touch screen to modify the parameter.
Table 2-35 Channel Spacing for ACP Measurement
channel spacing/100, Min = 1 Hz
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 3 Hz to 1.5 GHz.
For details about the Auto Couple and Meas Preset menus, refer to their descriptions on Page
RSA3000 User's Guide 2-47
2-44.
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10
Range
1 to 1,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
Channel Span
Span
Channel Span
Channel Span
Multichan Pwr
Measurement Interface:
Figure 2-7 Multi-channel Power Measurement Interface
Measurement Results: channel power and power sp ectral density
Channel Power: power within the channel span. Power Spectral Densit y: power (in dBm/Hz) normalized to 1 Hz within the
channel span.
Measurement Parameters: average count, average mode, auto average, channel frequency, and channel span.
1. Avg Number
Specif ies the number of times for averaging the measurement results. You can use the numeric keys, the knob, or arrow k eys to modify this para meter; you ca n also use the touch screen to modify the parameter.
Table 2-36 Average Count for Multi-channel Power Measurement
1
2-48 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
2. Avg Mode
Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is se lected, t he result is the e x ponential a ver a ge of the
measurement results obtained in the past N times (N is specified in "Avg Number").
When "Repeat" is selected, the result is the arithmetic average of the
measurement results obtained in the past N times (N is specified in "Avg
Number").
3. Avg State
Selects whether to averaging the measurement results. By default, it is set to "On".
4. Edit Channel
1) Channel Sheet
Opens or closes the channel editing table . When you select "On", the screen is split into two sections. The left section displays a channel editing table, and the right section displays the traces.
2) Navigations Selects the first line of the channel editing table. Note that when you selec t "Off" under Channel Sheet, this menu is invalid.
3) Channel Frequency
In the channel editing table, when a channel is selected, this menu
displays the center frequenc y of the selected channel. If you modify the frequency at this time, the center frequency of the corresponding selected channel will be updated at the same time.
When no channel is selected in the channel editing table, this menu
displays the center frequency of the last sele cted channel. At this time, you can set the center frequency of the channel according to your needs, and then press Add Channel to add a channel.
4) Channel Span
Sets the frequency width of the channel to be tested, and the power of the channel is the power integral within this bandwidth. You can use the numeric keys, the knob, or arrow keys to modify this parameter; you can also use the touch screen to modify the parameter. In the channel editing table, when a channel is selected, this menu
displays the channel span of the selected channel. If you modify the span at this time, the span of the corresponding selected channel will be updated at the same time.
When no channel is selected in the channel editing table, this menu
displays the span of the la st selected channe l. At this time, you can set
RSA3000 User's Guide 2-49
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
4.5 GHz
100 Hz to 2*Min[(channel
frequency)]
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
the span of the channel according to your needs, and then press Add Channel to add a channel.
Table 2-37 Channel Span
Range
[1]
frequency – start frequency), (stop frequen cy - channel
channel span/100, Min = 1 Hz
[1]
Note
: If option RSA3000-BW1 is installed, its minimum value can be set to 10 Hz.
5) Add Channel
If a channel is selected in t he ta ble editing table, pressing this key can
add a channel that is the same as the selected channel to the table.
When no channel is selected in the c hannel editing table, pressing this
key can add a channel whose center frequency is the same as the value under Channel Freq and whose span is the same as the value under
Channel Span. Note that when you select "Off" under Channel Sheet, this Add Channel menu is also valid.
6) Delete Channel
Press this key to delete the currently selected channel. Note that when you selec t "Off" under Channel Sheet or no channel is selected, this Delete Channel menu is invalid.
7) Deletes All Channels
Press Del All Channel to clear data in the channel editing table, i.g. deleting all the channels. Note that when you selec t "Off" under Channel Sheet, this Del All Channel menu is also valid.
For details about the Auto Couple and Meas Preset menus, refer to their descriptions on
Page 2-44.
2-50 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Occupied BW
Measurement Interface:
Figure 2-8 OBW Measurement Interface
Measurement Results: occupied bandwidth and transmit frequency error. OBW: Use the integral calculation method to calculate the power within the
whole span, and then calculate the bandwidth occupied by the power based on the specified power ratio.
Transmit Frequency Error: indicates the difference between the center
frequency of the channel and that of the spectrum analyzer.
Measurement Parameters: average count, average mode, a uto average, max hold, span, and power ratio.
1. Avg Number
Specif ies the number of times for averaging the measurement results. You can use the numeric keys, the knob, or arrow k eys to modify this parameter; you can also use the touch screen to modify the parameter.
RSA3000 User's Guide 2-51
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10
Range
1 to 1000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
Table 2-38 Average Count for OBW Measurem e n t
1
2. Avg Mode
Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is se lected, t he result is the e x ponential a ver a ge of the
measurement results obtained in the past N times (N is specified in "Avg Number").
When "Repeat" is selected, the result is the arithmetic average of the
measurement results obtained in the past N times (N is specified in "Avg
Number").
3. Avg State
Selects whether to averaging the measurement results. By default, it is set to "On".
4. Max Hold
Enables or disables max hold. By default, it is "Off". When Max Hold is enabled, each measurement result is c om pared with the
previous result, and then disp lay whichever is the maximum.
When Max Hold is disabled, the current measureme nt result is displayed. Max Hold and average measurement mode are mutually exclusive. When
Max Hold is enabled, the average measurement mode will be automatically disabled.
5. OBW Span
Sets the frequency range of integral cal culation. The span is c onsistent with that of the spectrum analyzer. It is the frequency range of sweep. After it is set, the span of the spectrum analyzer will also be changed. You can use the numeric keys, the knob, or arrow keys to modify this param eter; you can also use the touch screen to modify the parameter.
2-52 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
2 MHz
Range
[1]
100 Hz to 4.5 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
Parameter
Remarks
Default
99%
Range
1% to 99.99%
Unit
%
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1%
Table 2-39 Span for OBW Measurement
OBW span/ 100, Min = 1 Hz
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 10 Hz to 4.5 GHz.
6. Power Ratio
Sets the percentage the si gnal power tak es up in the whole s pan power. You can use the numeric keys, the knob, or arrow k eys to modify this para meter; you ca n also use the touch screen to modify the parameter.
Table 2-40 Power Ratio for OBW Measurement
0.01%
For details about the Auto Couple and Meas Preset menus, refer to their descriptions on Page
2-44.
RSA3000 User's Guide 2-53
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
10
Range
1 to 1,000
Unit
None
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1
Emission Bandwidth (EBW)
Measurement Interface:
Figure 2-9 EBW Measurement Interface
Measurement Results: EBW, i.g. the bandwidth between two points on the signal which are X dB below the highest point within the span. During the measurement, the analyzer f irst determines the frequency (f within the span, and then finds the two frequency points (f right side of f
at which the signal am plit ude is X dB below the maximum amplitude.
0
) of the maximum amp litude point
0
and f2) at the left and
1
The EBW equals to f2-f1. Measurement Parameters: average count, average mode, a uto average, max hold, span, and X dB.
1. Avg Number
Specif ies the number of times for averaging the measurement results. You can use the numeric keys, the knob or arrow keys to modify this parameter.
Table 2-41 Average Count for EBW Measurement
1
2-54 RSA3000 User’s Guide
Chapter 2 Functions of the Front Panel of GPSA RIGOL
Parameter
Remarks
Default
2 MHz
Range
[1]
100 Hz to 4.5 GHz
Unit
GHz, MHz, kHz, Hz
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
at 1-1.5-2-3-5-7.5 step
2. Avg Mode
Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is selected, the result is the e x ponential a ver a ge of the
measurement results obtained in the past N times (N is specified in "Avg Number").
When "Repeat" is selected, the result is the arithmetic average of the
measurement results obtained in the past N times (N is specified in "Avg
Number").
3. Avg State
Selects whether to averaging the measurement results. By default, it is set to "On".
4. Max Hold
Enables or disables max hold. By default, it is "Off". When Max Hold is enabled, each measurement result is c om pared with the
previous result, and then disp lay whichever is the maximum.
When Max Hold is disabled, the current measureme nt result is displayed. Max Ho ld and average measur ement mode are mut ually exclusive. When
Max Hold is enabled, the average measurement mode will be automatically disabled.
5. EBW Span
This span is consistent with the span of the spec trum analyzer. It refers to the frequency range of the sweep. After it is set, the span of the spectrum analyzer will be modified accordingly. You can use the numeric keys, the knob, or arrow keys to modify this parameter; you can also use the touch scr e e n to mod ify the parameter.
Table 2-42 Span for EBW Measurement
[1]
Note
: If option RSA3000-BW1 is installed, the available range is from 10 Hz to 4.5 GHz.
6. EBW X dB
Sets the value of X dB, which is used for EBW calculation. You can use the numeric keys, t h e k nob, or arrow keys to modify this parameter; you can also use the touch screen to modify t he paramete r.
RSA3000 User's Guide 2-55
EBW span /100, Min = 1 Hz
RIGOL Chapter 2 Functions of the Front Panel of GPSA
Parameter
Remarks
Default
-10 dB
Range
-100 dB to -0.1 dB
Unit
dB
Knob Step
Left/Right Arrow Key Step
Up/Down Arrow Key Step
1 dB
Table 2-43 X dB for EBW Measurement
0.1 dB
For details about the Auto Couple and Meas Preset menus, refer to their descriptions on Page
2-44.
2-56 RSA3000 User’s Guide