Rigol DS1104Z-S Plus, DS1074Z-S Plus, MSO1074Z, DS1104Z Plus, DS1074Z Plus User Manual

...
RIGOL
User’s Guide
MSO1000Z/DS1000Z Series
Digital Oscilloscope
Aug. 2015
RIGOL

Guaranty and Declaration

Copyright
© 2014 RIGOL Technologies, Inc. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL Technologies, Inc.
Publication Number
UGA19108-1110
Software Version
00.04.03.SP1 Software upgrade might change or add product features. Please acquire the latest version of the manual from RIGOL website or contact RIGOL to upgrade the software.
Notices
RIGOL products are cove red by P.R.C. and f oreign pa tents, issue d and pendin g. RIGOL reserves the right to modify or change parts of or all the specifications
and pricing policies at company’s sole decision.
Information in this publica tion re places all previ ously corresponding material. Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use or performance of this manual as well as a ny information contained.
Any part of this document is forbidden to be copi e d, photocopied or rearranged
without prior written approval of RIGOL.
Product Certification
RIGOL guar antees this pr oduct confo rms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certif ication is in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com
MSO1000Z/DS1000Z User’s Guide I
RIGOL

Safety Requirement

General Safety Summary

Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injury or damag e to the instrument and any product connecte d to it. To prevent potential haza rds, please us e the instrument only specified by this manual.
Use Proper Power Cord.
Only the power cord designed for the instrument and authorized for use within the local country could be used.
Ground the Instrument.
The instrument is grounded through the Protective Earth lead of the power cord. To avoid electric shock, it is e ssential t o connect the ea rth terminal of the power cord to the Protective Earth terminal before connecting any inputs or outputs.
Connect the Probe Correctly.
If a probe is used, do not connect the ground lead to high vol t age since it has isobaric electric potential as the ground.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all ratin gs and markers on the instrume nt and check your manual for more information about ratings before connecting the instrument.
Use Proper Overvoltage Protection.
Make sure that no overvoltage (such as that caused by a thunderstorm) can reach the product, or else the operator might be exposed to the danger of electrical shock .
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Anything Into the Holes of Fan.
Do not insert anything into the holes of the fan to avoid damaging the instrument.
Use Proper Fuse.
Please use the specified fuses.
Avoid Circuit or Wire Exposure.
Do not touch exposed junctions and components when the unit is powered.
II MSO1000Z/DS1000Z User’s Guide
RIGOL
Do Not Operate With Suspected Failures.
If you suspect damage occurs to the instrument, have it inspected by RIGOL authorized personnel before further oper at io ns. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
Keep Well Ventilation.
Inadequate ventilation may cause an increase of instrument temperature which would cause damage to the instrument. So please keep the instrument well ventilated and inspect the intake and fan regularly.
Do Not Operate in Wet Conditions.
In order to av oid short circuiting t o the interi or of the device or electric shock, please do not operate the instrument in a humid environment.
Do Not Operate in an Explosive Atmosphere.
In order to avoid damage to the device or personal injuries, it is important to o perate the device away fr om an expl osive atmosphere.
Keep Product Surfaces Clean and Dry.
To avoid the influence of dust and/or moisture in the air, please keep the surface of the device clean and dry.
Electrostatic Prevention.
Operate the instrument i n an ele ctrostatic discha rge protectiv e envi ronment to avoid damage induced by static discharges. Always ground both the internal and external conductors of cables to release static before making connections.
Proper Use of Battery.
If a battery is supplied, it must not be exposed to high temperature or in contact with fire. Keep it out of the reach of children. Improper change of battery (note: lithium battery) may cause explosion. Use RIGOL specified battery on l y.
Handling Safety.
Please handle with care during transportation to avoid damage to keys, knob interfaces and other parts on the panels.
MSO1000Z/DS1000Z User’s Guide III
RIGOL
WARNING
injury or loss of life.
CAUTION
damage to this product or other property.
DANGER
It calls attention to an operation, if not correctly pe rformed, could result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly pe rformed, could result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly pe rformed, could product.
Hazardous
Safety
Protective
Chassis
Test

Safety Terms and Symbols

Terms Used in this Manual. These terms may appear in this manual:
Warning statements indicate conditions or practices that could result in
Caution statements indicate conditions or practices that could result in
Terms Used on the Product. These terms may appear on the product:
result in damage to the product or other devices connected to the
Symbols Used on the Product. These symbols may appear on the product:
Voltage
Warning
Earth Terminal
Ground
Ground
IV MSO1000Z/DS1000Z User’s Guide
RIGOL

Allgemeine Sicherheits Informationen

Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonenschädenoderSchäden am Gerätundan damit verbundenen weiteren Gerätenzu vermeiden. Zur Vermeidung vonGefahren, nut zen Sie bitte das Gerät nur so, wiein diesem Handbuchangegeben.
Um Feuer oder Verletzungen zu vermeiden, verwenden Sie ein ordnungsgemäßes Netzkabel.
Verwenden Sie für dieses Gerät nur das für ihr Land zugelassene und genehmigte Netzkabel.
Erden des Gerätes.
Das Gerät ist durch den Schutzleiter im Netzkabel geerdet. Um Gefahren durch elektrischen Schlag zu vermeiden , ist es unerlässlich, die Er dung durchzufüh ren. Erst dann dürfen weitere Ein- oder Ausgänge verbunden werden.
Anschluss einesTastkopfes.
Die Erdungsklemmen der Sonden sindauf dem gleichen Spannungspegel des Instruments geerdet. SchließenSie die Erdungsklemmen an keine hohe Spannung an.
Beachten Sie alle Anschlüsse.
Zur Vermeidung von Feuer oder Stromschlag, beachten Sie alle Bemerkungen und Markierungen auf dem Instrument. Bef olgen Sie die Bedienun gsanleitung für weitere Informationen, bevor Sie weitere Anschlüsse an das Instrument legen.
Verwenden Sie einen geeigneten Überspannungsschutz.
Stellen Sie sicher, daß keinerlei Überspannung (wie z.B. durch Gewitter verursacht) das Gerät erreichen kann. Andernfallsbestehtfür den Anwender die GefahreinesStromschlages.
Nicht ohne Abdeckung einschalten.
Betreiben Sie das Gerät nicht mit entfernten Gehäuse-Abdeckungen.
Betreiben Sie das Gerät nicht geöffnet.
Der Betrieb mit offenen oder entfernten Gehäuseteilen ist nicht zulässig. Nichts in entsprechende Öffnungen stecken (Lüfter z.B.)
Passende Sicherung verwenden.
Setzen Sie nur die spezifikationsgemäßen Sicherungen ein.
Vermeiden Sie ungeschützte Verbindungen.
Berühren Sie keine unisolierten Verbindungen oder Baugruppen, während das Gerät in Betrieb ist.
MSO1000Z/DS1000Z User’s Guide V
RIGOL
Betreiben Sie das Gerät nic h t i m Fehlerfall.
Wenn Sie am Gerät einen Defekt vermuten, sorgen Sie dafür, bevor Sie das Gerät wieder betreiben, dass eine Untersuchung durch RIGOL autorisiertem Personal durchgeführt wird. Jedwede W artun g, Einstellarbeit en oder Austausch v on Teilen am Gerät, sowie am Zubehör dürfen nur von RIGOL autorisiertem Pe rs onal durchgeführt werden.
Belüftung sicherstellen.
Unzureichende Belüftung kann zu Temperaturanstiegen und somit zu thermischen Schäden am Gerät führen. Stellen Sie deswegen die Belüftung sicher und kontrollieren regelmäßig Lüfter und Belüftungsöffnungen.
Nicht in feuc h te r Um g ebung betrei be n .
Zur Vermeidun g von Kurzschluß im Geräteinne ren und Stromschlag betreiben Sie das Gerät bitte niemals in feuchter Umgebung.
Nicht in explosiver Atmosphäre betreiben.
Zur Ve rm e idung von Pe rsonen- und Sachschäden ist es unumgänglich, das Gerät ausschließlich fernab jedweder explosiven At mosphäre zu betreiben.
Geräteoberflächen sauber und trocken halten.
Um den Einfluß von Staub und Feuchtigkeit aus der Luft auszuschließen, halten Sie bitte die Geräteoberflächen sauber und trocken.
Schutz gegen elektrostatische Entladung (ESD).
Sorgen Sie für eine elektrostatisch geschützte Umgebung, um somit Schäden und Funktionsstörungen durch ESD zu vermeiden. Erden Sie vor dem Anschluß immer Innen- und Außenleiter der V erbindungsleitung, um sta tische Aufladung zu entladen.
Die richtige Verwendung desAkku.
Wenneine Batterieverwendet wird, vermeiden Sie hohe Temperaturen bzw. Feuer ausgesetzt werden. Bewahren Sie es außerhalbder Reichweitevon Kindern auf. Unsachgemäße Änderung derBatt e rie (Anmerkung: Lithium-Batterie) kann zu einer Explosion führen. VerwendenSie nur von RIGOL angegebenenAkkus.
Sicherer Transport.
Transportieren Sie das Gerät sorgfältig (Verpackung!), um Schäden an Bedienelementen, Anschlüssen und anderen Teilen zu vermeiden.
VI MSO1000Z/DS1000Z User’s Guide
RIGOL
WARNING
Schäden oder den Tod von Personen zur Folge haben können.
CAUTION
Schäden am Gerät hervorrufen können.
DANGER
weist auf eine Verletzung ode r Gefäh r dun g hin, die s o fort geschehen kann.
WARNING
weist auf eine Verletzung oder Gefäh rdung hin, die möglicherweise nicht sofort geschehen.
CAUTION
weist auf eine Verletzun g ode r Gefährdung hin und bedeutet, dass Gegenstände auftreten kann.

Sicherheits Begriffe und Symbole

Begriffe in diesem Guide. Diese Begrif fe können in diesem Handbuch aufta uchen:
Die Kennzeichnung WARNING beschreibt Gefahrenquelle n die leibliche
Die Kennzeichnung Caution (Vorsicht) beschreibt Gefahrenquellen die
Begriffe auf dem Produkt. Diese Bedingungen können auf dem Produkt erscheinen:
eine mögliche Beschädigung des Instruments oder anderer
Symbole auf dem Produkt. Diese Symbole können auf dem Produkt erscheinen:
Gefährliche Spannung
Sicherheits­Hinweis
Schutz-erde Gehäusemasse Erde
MSO1000Z/DS1000Z User’s Guide VII
RIGOL
WARNING
measurement categories.

Measurement Category

Measurement Category
MSO1000Z/DS1000Z series digital oscilloscopes can mak e meas urements in Measurement Category I.
This oscilloscope can only be used for measurements within its specified
Measurement Category Definitions
Measuremen t c ategory I is for measurements performed on circuits not directly connected to MAINS. Examples a re m e a s urements on circu its not derived from MAINS, and specially protected (internal) MAINS derived circuits. In the latter case, transient stresses are variable. For that reason, the transient withstand capability of the equipment is made known to the user.
Measurement category II is for measurements performed on circuits directly connected to low voltage installations. Examples are measurements on household appliances , portable tools and similar equipment.
Measurement category III is for measurements performed in building installations. Examples are measurements on distribution boards, circuit-breakers, wiring (including cables, bus-bars, junction boxes, switches and socket-outlets) i n fix ed installations, equipment for industrial use and some othe r equip ment. For exam ple, stationary motors with permanent connection to a fixed installation.
Measurement category IV is for measurements performed at the source of a low-voltage installation. Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units.
VIII MSO1000Z/DS1000Z User’s Guide
RIGOL
WARNING
during operation and inspect the intake and fan regularly.

Ventilation Requirement

This oscilloscope uses fan to force cooling. Please make sure that the air intake and exhaust areas are free from obstructions and have free air. When using the oscilloscope in a bench-top or rack setting, provide at least 10 cm clearance beside, above and behind the instrument for adequate ventilation.
Inadequate ventilation may cause a temperature increase which can damage the instrument. So please keep the instrument well ventilated
MSO1000Z/DS1000Z User’s Guide IX
RIGOL
WARNING
not operate in humid environment.
WARNING
exposed to the danger of electric shock.

Working Environment

Temperature
Operating: 0 to +50 Non-operating: -40℃ to +70
Humidity
0 to +30: ≤95% relative humidity +30 to +40: ≤75% relative humidity +40 to +50: ≤45% relative humidity
To avoid short circuits inside the instrument or electric shocks, please do
Altitude
Operating: below 3 km Non-operating: below 15 km
Installation (Overvoltage) Category
This product is powered by mains conforming to installation (overvoltage) category II.
Installation (Overvoltage) Cate g o ry Definitio n s
Installation (overvoltage) category I refers to signal level which is applicable to equipment measurement terminals connected to the source circuit. In these terminals, precautions are done to limit the transient voltage to the corresponding low level. Installation (overvoltage) category II refers to the local power distribution level which is applicable to equipment connected to the AC line (AC power).
Pollution Degree
Degree 2
Pollution Degree Definitions
Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. For example, a clean room or air-conditioned office environment.
X MSO1000Z/DS1000Z User’s Guide
Make sure that no over volta ge (such as that produced by a thunderstorm) can reach the product, or else the operator might be
RIGOL
Pollution degree 2: Normally only dry, non-conductive pollution occurs. Occasionally a temporary conductivity caused by condensation may occur. For example, general indoor environment. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to condensation which is expected. For example, sheltered outdoor environment. Pollution degree 4: Pollution that generates persistent conductivity through conductive dust, rain, or snow. For ex amp le, outdoor locations.
Safety Class
Class 1 – Grounded Product
MSO1000Z/DS1000Z User’s Guide XI
RIGOL
CAUTION
WARNING
supply.

General Care and Cleaning

General Care
Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions. To clean the exterior surface, perform the following steps:
1. Disconnect the instrument from all power sources.
2. Clean the loose dust on th e outs ide of the inst rumen t with a lint-free cloth (with a mild detergent or water). When cleaning the LCD, take care to av oid scari fying it.
To avoid damage to the instrument, do not expose it to caustic liquids.
To avoid short-circuit and personal injury resulting from moisture, make sure the instrument is completely dry before reconnecting it to power

Environmental Consideratio ns

The following symbol indicates that this product complies with the WEEE Directive 2002/96/EC.
Product End-of-Life Handling
The equipment may c ontain s ubstan ces that could b e ha rmful t o the envi ronm ent o r human health. In order to avoid release of such su bstances into the en vironment and harm to human health, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately. Please contact your local authorities for disposal or recycling information.
XII MSO1000Z/DS1000Z User’s Guide
RIGOL
MSO1000Z/DS1000Z User’s Guide XIII
RIGOL

MSO1000Z/DS1000Z Series Overview

MSO1000Z/DS1000Z series is a multifunctional and high-performance digital oscilloscope designed on t he basis of t he Ultra Vision t echnique developed by RIGOL. Featuring extremely high memo ry depth, wide dyn amic range, clear display, excellent waveform capture rate and comprehensive triggering functions, it is a useful commissioning instrument for various fields such as communication, aerospace, defense, embedded systems, computers, research and education. Wherein, the mixed signal digital oscilloscope aimed at the embedded design and test field s allows users to measure analog and digital signals at the same time. MSO1000Z/DS1000Z is the one with the most comprehensive functio ns and the most outstanding specifications among the 100 MHz bandwidth digital oscilloscopes.
Main feature s:
1 GSa/s real-time sample rate of the analog channels; up to 24 Mpts memory
depth (optional) and 12 Mpts standard memory depth
1 GSa/s real-time sample rate of the digital channels 100 MHz, 70 MHz and 50 MHz analog channel bandwidth 4 analog channels, 16 digital channels (for MSO1000Z and MSO upgradable for
DS1000Z Plus)
Dual-channel 25 MHz signal source (applicable to digital oscilloscopes with
source channels)
30 000 wfms/s (dots display) waveform capture rate Real-time hardware waveform recording and playback functions; up to 60 000
frames of waveform can be recorded
MSO field upgradable with MSO1000Z upgrade package (MSO upgrade option,
only for DS1000Z Plus)
Intensity graded color display Low base noise, 1 mV/div to 10 V/div ultra-wide vertical dynamic range 7.0 inch WVGA (800*480) TFT LCD, with ultra-wide screen , vivid picture, low
power consumption and long service life
Adjustable waveform brig htne ss Auto setting of waveform display (AUTO) Up to 15 kinds of trigger functions, including various protocol triggers Standard parallel decoding, supports multiple serial decoding options Auto measurement of 33 waveform parameters (with statistics) Fine delayed sweep function Built-in FFT function Multiple waveform math operation functions Pass/fail test function Standard interfaces: USB Device, U S B Host, LAN, Aux, GPIB (extend ed via the
USB Host interface)
Conform to LXI CORE 2011 DEVICE class instrument standards; enable quick,
economic and efficient creation and reconfiguration of test system
Supports remote command control
XIV MSO1000Z/DS1000Z User’s Guide
RIGOL
Built-in help to facilitate information acquisition Supports multiple languages and Chinese/English input Novel and delicate industrial design and easy operation
MSO1000Z/DS1000Z User’s Guide XV
RIGOL

Document Overview

Main Topics of this Manual:
Chapter 1 Quick Start
Introduce the preparations before using the oscilloscope and provide a basic introduction of the instrument.
Chapter 2 To Set the Vertical System
Introduce the vertical system functions of the oscilloscope.
Chapter 3 To Set the Horizontal System
Introduce the horizontal system functions of the oscilloscope.
Chapter 4 To Set the Sample System
Introduce the sample system functions of the oscilloscope.
Chapter 5 To Trigger the Oscilloscope
Introduce the trigger mode, trigger coupling, trigger holdoff, external trigger and various trigger types of the oscilloscope.
Chapter 6 MATH and Measurement
Introduce how to make math operation, auto measurement and cursor measurement.
Chapter 7 Digital Chann e l
Introduce how to use the digital channels of the mixed signal digital oscilloscope.
Chapter 8 Protocol Decoding
Introduce how to decode the input signal using those common protocols.
Chapter 9 Reference Waveform
Introduce how to compare the input waveform with the reference wav ef o rm.
Chapter 10 Pass/Fail Test
Introduce how to monitor the input signal using the Pass/Fail test.
Chapter 11 Waveform Record
Introduce how to analyze the input signal using w aveform re cord.
Chapter 12 Display Control
Introduce how to control the display of the oscilloscope.
Chapter 13 Signal Source
Introduce how to use the built-in signal source.
XVI MSO1000Z/DS1000Z User’s Guide
RIGOL
Chapter 14 Store and Recall
Introduce how to store and recall the measurement result and the setting of the oscilloscope.
Chapter 15 Accessibility Setting
Introduce how to set the remote interfaces and system-related functions.
Chapter 16 Remote Control
Introduce how to control the oscilloscope remotely.
Chapter 17 Troubleshooting
Introduce how to deal with the common failures of the oscilloscope.
Chapter 18 Specifications
Provide the specifications and general specifications of the oscilloscope.
Chapter 19 Appendix
Provide common information such as the options and accessories.
Format Conventions in this Manual:
1. Key
The front panel keys are denoted by the f ormat of "Key Name (Bold) + T ext Box". For example, Utility denotes the "Utility" key.
2. Menu
The menu items are denoted by the format of "Menu Word (Bold) + Character Shading". For example, System denotes the "System" menu item under
Utility.
3. Operation Step
The next step of ope ration is denote d b y an a rrow "". For example, Utility System denotes pressing Utility at the front panel and then pressi ng System.
4. Knob
Label Knob
HORIZONTAL SCALE HORIZONTAL POSITION VERTICAL SCALE VERTICAL POSITION TRIGGER LEVEL
Horizontal Scale Knob Horizontal Position Knob Vertical Scale Knob Vertical Position Knob Trigger Level Knob
MSO1000Z/DS1000Z User’s Guide XVII
RIGOL
Number of
Channels
Number of
Channels
Content Conventions in this Manual:
MSO1000Z/DS1000Z series includes the following models. Unless otherwise noted, this manual takes MSO1104Z-S for example to illustrate the functions and operation methods of MSO1000Z/DS1000Z series.
Model
MSO1104Z-S 100 MHz 4 2 16 MSO1074Z-S 70 MHz 4 2 16 MSO1104Z 100 MHz 4 -- 16 MSO1074Z 70 MHz 4 -- 16 DS1104Z-S Plus 100 MHz 4 2 16 DS1074Z-S Plus 70 MHz 4 2 16 DS1104Z Plus 100 MHz 4 -- 16 DS1074Z Plus 70 MHz 4 -- 16 DS1054Z 50 MHz 4 -- --
[1]
Note
: Need to be upgraded to MSO using the MSO upgrade option.
Analog Bandwidth
Analog
Number of Source Channels
Digital
[1]
[1]
[1]
[1]
Manuals of this Product:
The manuals of this product include the quick guide, user’s guide, programming guide, data sheet and etc. The latest versions of the manuals can be downloaded from RIGOL official website (
www.rigol.com).
XVIII MSO1000Z/DS1000Z User’s Guide
Contents RIGOL
Contents
Guaranty and Declaration ......................................................................... I
Safety Requirement ................................................................................ II
General Safety Summary ........................................................................... II
Safety Terms and Symbols ....................................................................... IV
Allgemeine Sicherheits Informationen ......................................................... V
Sicherheits Begriffe und Symbole ............................................................. VII
Measurement Category .......................................................................... VIII
Ventilation Requirement ........................................................................... IX
Working Enviro nment ............................................................................... X
General Care and Cleaning ...................................................................... XII
Environmental Considerations .................................................................. XII
MSO1000Z/DS1000Z Series Overview ................................................. XIV
Document Overview ............................................................................. XVI
Chapter 1 Qui ck Start ......................................................................... 1-1
General Inspection ................................................................................ 1-2
Appearance and Dim e nsions ................................................................... 1-3
To Prepare the Oscilloscope for Use ......................................................... 1-4
To Adjust the Supporting Legs .......................................................... 1-4
To Connect to Power Supply............................................................. 1-4
Power-on Inspection ....................................................................... 1-5
To Connect the Probe ...................................................................... 1-5
Function Inspection ......................................................................... 1-7
Probe Compensation ....................................................................... 1-8
Panel Overview ............................................................................. 1-9
Front
Rear Panel Overview ............................................................................. 1-10
Front Panel Function Overview............................................................... 1-12
VERTICAL ..................................................................................... 1-12
Logic Analyzer ............................................................................... 1-13
Signal Source ................................................................................ 1-13
HORIZONTAL ................................................................................ 1-14
TRIGGER ...................................................................................... 1-15
CLEAR .......................................................................................... 1-15
AUTO............................................................................................ 1-15
RUN/STOP .................................................................................... 1-16
SINGLE ......................................................................................... 1-16
Multifunction Knob ......................................................................... 1-16
Function Menus ............................................................................. 1-17
Print ............................................................................................. 1-18
User Interface ...................................................................................... 1-19
Parameter Setting Method ..................................................................... 1-24
To Use the Security Lock ....................................................................... 1-25
MSO1000Z/DS1000Z User’s Guide XIX
RIGOL Contents
To Use the Built-in Help System ............................................................. 1-26
Chapter 2 To Set the Vertical System ................................................. 2-1
To Enable the Analog Channel ................................................................. 2-2
Channel Coupling ................................................................................... 2-2
Bandwidth Limit ..................................................................................... 2-3
Probe Ratio ........................................................................................... 2-3
Waveform Invert .................................................................................... 2-4
Vertical Scale ......................................................................................... 2-4
Amplitude Unit ....................................................................................... 2-5
Channel Label ........................................................................................ 2-5
Delay Calibration of the Analog Channel ................................................... 2-7
Chapter 3 To Set the Horizontal System ............................................ 3-1
Delayed Sweep ...................................................................................... 3-2
Time Base Mode .................................................................................... 3-3
YT Mode ......................................................................................... 3-3
XY Mode ......................................................................................... 3-3
Roll Mode ....................................................................................... 3-5
Chapter 4 To Set the Sample System ................................................. 4-1
Acquisition Mode .................................................................................... 4-2
Normal ........................................................................................... 4-2
Peak Detect .................................................................................... 4-2
Average .......................................................................................... 4-2
High Resolution ............................................................................... 4-3
Sin(x)/x ................................................................................................. 4-4
Sample Rate .......................................................................................... 4-4
Memory Depth ....................................................................................... 4-6
Antialiasing ............................................................................................ 4-7
Chapter 5 To Trigger the Oscilloscope ................................................ 5-1
Trigger Source ....................................................................................... 5-2
Trigger Mode ......................................................................................... 5-3
Trigger Coupling..................................................................................... 5-4
Trigger Holdoff ....................................................................................... 5-5
Noise Rejection ...................................................................................... 5-5
Trigger Type .......................................................................................... 5-6
Edge Trigger ................................................................................... 5-7
Pulse Trigger ................................................................................... 5-8
Slope Trigger ................................................................................. 5-10
Video Trigger................................................................................. 5-13
Pattern Tr igg er .............................................................................. 5-15
Duration Trigger ............................................................................ 5-17
TimeOut Trigger (Optional) ............................................................. 5-19
Runt Trigger (Optional) .................................................................. 5-21
Window Trigger (Optional) .............................................................. 5-23
Delay Trigger (Optional) ................................................................. 5-25
XX MSO1000Z/DS1000Z User’s Guide
Contents RIGOL
Setup/Hold Trigger (Optional) ......................................................... 5-28
Nth Edge Trigger (Optional) ............................................................ 5-30
RS232 Trigger (Optional) ................................................................ 5-32
I2C Trigger (Optional) .................................................................... 5-34
SPI Trigger (Optional) .................................................................... 5-37
Trigger Output Connector ...................................................................... 5-39
Chapter 6 MATH and Measurement .................................................... 6-1
Math Operation ..................................................................................... 6-2
Addition ......................................................................................... 6-2
Subtraction .................................................................................... 6-3
Multiplication .................................................................................. 6-4
Division .......................................................................................... 6-4
FFT ............................................................................................... 6-6
"AND" Operation ............................................................................ 6-11
"OR" Operation .............................................................................. 6-12
"XOR" Operation ............................................................................ 6-13
"NOT" Operation ............................................................................ 6-14
Intg .............................................................................................. 6-15
Diff ............................................................................................... 6-16
Sqrt .............................................................................................. 6-17
Lg (Use 10 as the Base) ................................................................. 6-17
Ln ................................................................................................ 6-18
Exp .............................................................................................. 6-19
Abs .............................................................................................. 6-20
Filter............................................................................................. 6-21
Fx Operation ................................................................................. 6-22
Math Operation Label ..................................................................... 6-23
Auto Measurement ............................................................................... 6-24
Quick Measurement after AUTO....................................................... 6-24
One-key Measurement of 33 Parameters .......................................... 6-25
Frequency Counter Measurement .................................................... 6-30
Measuremen t Setting ..................................................................... 6-30
To Clear the Measurement .............................................................. 6-31
All Measurement ............................................................................ 6-33
Statistic Function ........................................................................... 6-33
Measurement History ..................................................................... 6-34
Measurement Result Display Type .................................................... 6-34
Cursor Measurement............................................................................. 6-35
Manual Mode ................................................................................. 6-35
Track Mode ................................................................................... 6-39
Auto Mode .................................................................................... 6-41
XY Mode ....................................................................................... 6-42
Chapter 7 Digital Channel ................................................................... 7-1
To Select the Digital Channel .................................................................. 7-2
To Turn on/off the Digital Channel ........................................................... 7-2
MSO1000Z/DS1000Z User’s Guide XXI
RIGOL Contents
Group Set .............................................................................................. 7-3
To Set the Waveform Display Size ............................................................ 7-4
Reorder Setting ...................................................................................... 7-4
Auto View.............................................................................................. 7-4
To Set the Threshold .............................................................................. 7-4
To Set the Label ..................................................................................... 7-5
Probe Calibration .................................................................................... 7-5
Digital Channel Delay Calibration ............................................................. 7-5
Chapter 8 Protocol Decoding ............................................................. 8-1
Parallel Decoding ................................................................................... 8-2
RS232 Decodi n g (Optional) ..................................................................... 8-7
I2C Decoding (Optional) ....................................................................... 8-12
SPI Decoding (Optional) ....................................................................... 8-15
Chapter 9 Reference Waveform ......................................................... 9-1
To Enable REF Function .......................................................................... 9-2
To Select REF Source .............................................................................. 9-2
To Adjust REF Waveform Display ............................................................. 9-2
To Save to Internal Memory .................................................................... 9-2
To Set the Color ..................................................................................... 9-3
To Reset the Reference Waveform ........................................................... 9-3
To Export to Internal or Ext e rn al Memory ................................................. 9-3
To Import from Internal or External Memor y ............................................. 9-3
Chapter 10 Pass/Fail T est ............................................................ 10-1
To Enable Pass/Fail Test ........................................................................ 10-2
To Select Source .................................................................................. 10-2
Mask Range ......................................................................................... 10-2
Test and Output ................................................................................... 10-3
To Save the Test Mask .......................................................................... 10-4
To Load the Test Mask .......................................................................... 10-4
Chapter 11 Waveform Record ...................................................... 11-1
Common Settings ................................................................................. 11-2
Playback Option ................................................................................... 11-3
Record Option ...................................................................................... 11-4
Chapter 12 Display Control .......................................................... 12-1
To Select the Display Type .................................................................... 12-2
To Set the Persistence Time .................................................................. 12-2
To Set the Waveform Intensity .............................................................. 12-3
To Set the Screen Grid .......................................................................... 12-3
To Set the Grid Brightness..................................................................... 12-3
Chapter 13 Signal Source ............................................................ 13-1
To Output Basic Waveform .................................................................... 13-2
To Output Sine .............................................................................. 13-2
To Output Square .......................................................................... 13-3
XXII MSO1000Z/DS1000Z User’s Guide
Contents RIGOL
To Output Ramp ............................................................................ 13-4
To Output Pulse ............................................................................. 13-5
To Output DC ................................................................................ 13-5
To Output Noise ............................................................................. 13-6
To Output Built-in Waveform .................................................................. 13-6
To Output Arbitrary Waveform ............................................................. 13-10
To Select Waveform ..................................................................... 13-11
To Create Waveform ..................................................................... 13-12
To Edit Waveform ........................................................................ 13-14
Modulation ........................................................................................ 13-15
AM ............................................................................................. 13-16
FM ............................................................................................. 13-17
Chapter 14 Store and Re call ......................................................... 14-1
Storage System .................................................................................... 14-2
Storage Type ....................................................................................... 14-2
Internal Storage and Recall ................................................................... 14-4
External Storage and Recall ................................................................... 14-5
Disk Management ................................................................................. 14-6
To Select File Type ......................................................................... 14-6
To Create a New File or Folder ........................................................ 14-7
To Delete a File or Folder .............................................................. 14-10
To Rename a File or Folder ........................................................... 14-10
To Clear the Local Memory ............................................................ 14-10
Factory .............................................................................................. 14-11
Chapter 15 Accessibil i ty Setting ................................................... 15-1
Remote Interface Configuration ............................................................. 15-2
LAN Configuration .......................................................................... 15-3
USB Device ................................................................................... 15-6
GPIB Address ................................................................................ 15-6
System-related ..................................................................................... 15-7
Sound ........................................................................................... 15-7
Language ...................................................................................... 15-7
System Informat i on ........................................................................ 15-7
Vertical Reference .......................................................................... 15-7
Power-off Recall ............................................................................. 15-8
Self-calibration ............................................................................... 15-8
Print Setting .................................................................................. 15-9
Aux Output ................................................................................. 15-11
Option Management ..................................................................... 15-12
Auto Options ............................................................................... 15-13
Key Lock ..................................................................................... 15-13
Chapter 16 Remote Control .......................................................... 16-1
Remote Control via USB ........................................................................ 16-2
Remote Control via LAN ........................................................................ 16-6
MSO1000Z/DS1000Z User’s Guide XXIII
RIGOL Contents
Remote Control via GPIB ....................................................................... 16-7
Chapter 17 Troubleshooting ........................................................ 17-1
Chapter 18 Specifications ............................................................ 18-1
Chapter 19 Appendix ................................................................... 19-1
Appendix A: Accessories and Options ..................................................... 19-1
Append i x B: Warranty ........................................................................... 19-2
Index ........................................................................................................ 1
XXIV MSO1000Z/DS1000Z User’s Guide
Chapter 1 Quick Start RIGOL

Chapter 1 Quick Start

This chapter introduces the preca utions when using t he oscilloscope for the first time, the front/rear panels of th e os cillosc ope , the user interface and the using method of the built-in help system.
The contents of this chapter:
General Inspection Appearance and Dimensions To Prepare the Oscilloscope for Use Front Rear Panel Overview Front Panel Function Overview User Interface Parameter Setting Method To Use the Security Lock To Use the Built-in Help System
Panel Overview
MSO1000Z/DS1000Z User’s Guide 1-1
RIGOL Chapter 1 Quick Start

General Inspection

1. Inspect the shipping container for damage
Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both ele ctrica l a nd mechanical tests.
The consigner or carrier shall be liable for the damage to instrument resulting from shipment. RIGOL woul d n ot be responsible f or free maintenance/rework or replacement of the unit.
2. Inspect the instrument
In case of any damage, or defect, or failure, notify your RIGOL sales representative.
3. Check the accessories
Please check the accessories according to the packi ng l is t s. If t he accessories are incomplete or damaged, pleas e contact your RIGOL sales representative.
1-2 MSO1000Z/DS1000Z User’s Guide
Chapter 1 Quick Start RIGOL

Appearance and Dimensions

Figure 1-1 Front View Unit: mm
Figure 1-2 Top View Unit: mm
MSO1000Z/DS1000Z User’s Guide 1-3
RIGOL Chapter 1 Quick Start
Power Socket

To Prepare the Oscilloscope for Use

To Adjust the Supporting Legs

Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement of the oscilloscope as well as better operation and observation.
Figure 1-3 To Adjust the Supporting Legs

To Connect to Power Supply

The power requirements of the oscilloscope are 100-240 V, 45-440 Hz. Please use the power cord supplied with the accessories to connect the oscilloscope to the AC power source as shown in the figure below.
1-4 MSO1000Z/DS1000Z User’s Guide
Figure 1-4 To Connect to Power Supply
Loading...
+ 242 hidden pages