RIGOL DP821A, DP832A, DP811A, DP831A Users guide

RIGOL
User’s Guide
DP800A Series Programmable
Linear DC Power Sup ply
Jun. 2016
RIGOL

Guaranty and Declaration

Copyright
© 2012 RIGOL TECHNOLOGIES, INC. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC.
Publication Number
UGH03109-1110
Software Version
00.01.14 Software upgrade might change or add product features. Please acquire the latest version of the manual from RIGOL we bsite or contact RIGOL to upgrade the software.
Notices
RIGOL produ cts are cov ered by P.R.C. and f oreign pa tents, issue d and pendin g. RIGOL reserves the right to modify or change parts of or all the specifications
Information in this publication replaces all previously released materials. Information in this publication is subject to change without notice. RIGOL shall not be liable for either incidental or consequential losses in
Any part of this document is f orbi dden to be copie d, phot ocopie d, or rearranged
Product Certification
RIGOL guarantees that this product conforms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com
and pricing policies at the company’s s ole de cision .
connection with the furnishing, use, or performance of this manual, as well as any information contained.
without prior written approval of RIGOL.
DP800A User’s Guide I
RIGOL

Safety Requirement

General Safety Summary

Please review the following safety pre cautio ns ca refully before putting the instrument into operation so as to avoid any personal injury or damag e t o t he instrument and any product connected to it. To prevent potential hazards, please follow the instructions specified in this manual to use the instrument properly.
Use Proper Power Cord.
Only the exclusive power cord designed for the instrument and authorized for use within the local country could be used.
Ground the Instrument.
The instrument is grounded through the Protective Earth lead of the power cord. To avoid ele ctric shock, connect the earth terminal of the power cord to the Protective Earth terminal before connecting any input or output terminals.
Connect the Probe Correctly.
If a probe is used, do not connect the ground lead to high voltage since it has isobaric electric potential as the ground.
Observe All Terminal Ratings.
To avoid fire or shock hazard, observe all r atings an d markers on the instrume nt and check your manual for more information about ratings before connecting the instrument.
Use Proper Overvoltage Protection.
Ensure that no over voltage (su ch as that cause d by a bolt of lightni ng) can reach the product. Otherwise, the operator might be exposed to the danger of an electric shock.
Do Not Operate Without Covers.
Do not operate the instrument with covers or panels removed.
Do Not Insert Anything Into the Air Outlet.
Do not insert anything into the air outlet to avoid damage to the instrument.
Use Proper Fuse.
Please use the specified fuses.
Avoid Circuit or Wire Exposure.
Do not touch exposed j unctions and components when the unit is powered on.
II DP800A User’s Guide
RIGOL
Do Not Operate With Suspected Failures.
If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized personnel before further operations. An y maintenance, adjustment or replacement especially to circuits or accessories must be perfor med by RIGOL authorized personnel.
Provide Adequate Ventilation.
Inadequate ventilation may cause an increase of t emperatur e in the instrument, which would cause damage to the instrument. So please keep the instrument well ventilated and inspect the air outlet and the fan regularly.
Do Not Operate in Wet Conditions.
To avoid short circuit inside the instrument or electric shock, never operate the instrument in a humid environment.
Do Not Operate in an Explosive Atmosphere.
To avoid personal injuries or damage to the instrument, never operate t he instrument in an explo sive atmosphere.
Keep Instrument Surfaces Clean and Dry.
T o a void dust or moisture from af fecting the pe rformance of the inst rument, keep the surfaces of the instrument clean and dry.
Prevent Electrostatic Impact.
Operate the instrume nt i n an electrost atic discharge protective environ ment to a void damage induced by static discharges. Always ground both the internal and external conductors of cables to release static before making connections.
Use the Battery Properly.
Do not expose the battery (if available) to high temperature or fire. Keep it out of the reach of children. Improper change of a battery (lithium battery) may cause an explosion. Use the RIGOL specified battery only.
Handle with Caution.
Please handle with care during transportation to avoid damage t o keys, knobs, interfaces, and other parts on the panels.
Do Not Provide Power for the Active Load.
In order to avoid the anti-irrigation current which leads to the power control loop out of control and damages the powered device, this power supply can only provide power for the pure load without the current output function.
DP800A User’s Guide III
RIGOL
CAUTION WARNING
It calls attention to an operation, if not correctly performed, could
CAUTION
Hazardous
Safety
Protective
Chassis
Test

Safety Notices and Symbols

Safety Notice s in this Manu al:
WARNING
Indicates a potentially hazardous situation or practice which, if not avoided, will result in serious injury or death.
Indicates a potentially hazardous situation or practice which, if not avoided, could result in damage to the product or loss of important data.
Safety Terms on the Product:
DANGER It calls attention to an operation, if not correctly pe rformed, could
result in injury or hazard immediately. result in potential injury or hazard.
It calls attention to an operation, if not correctly pe rformed, could
result in product.
Safety Symbols on the Product:
damage to the product or other devices connected to the
Voltage
Warning
Earth Terminal
Ground
IV DP800A User’s Guide
Ground
RIGOL

Allgemeine Sicherheits Informationen

Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonenschädenoderSchäden am Gerätundan damit verbundenen weiteren Gerätenzu vermeiden. Zur Vermeidung vonGefahren, nutzen S ie bitte das Gerät nur so, wiein diesem Handbuchangegeben.
Um Feuer oder Verletzungen zu vermeiden, verwenden Sie ein ordnungsgemäßes Netzkabel.
Verwenden Sie für dieses Gerät nur das für ihr Land zugelassene und genehmigte Netzkabel.
Erden des Gerätes.
Das Gerät ist durch den Schutzleiter im Netzkabel geerdet. Um Gefahren durch elektrischen Schlag zu vermeiden , ist es unerlässlich, die Er dung durchzufüh ren. Erst dann dür fen weitere Ein- oder Aus gä nge verbunden werden .
Anschluss einesTastkopfes.
Die Erdungsklemmen der Sonden sindauf dem gleichen Spannungspegel des Instruments geerdet. SchließenSie die Erdungsklemmen an keine hohe Spannung an.
Beachten Sie alle Anschlüsse.
Zur Vermeidung von Feuer oder Stromschlag, beachten Sie alle Bemerkungen und Markierungen auf dem Instrument. Bef olgen Sie die Bedienun gsanleitung für weitere Informationen, bevor Sie weitere Anschlüsse an das Instrument legen.
Verwenden Sie einen geeigneten Überspannungsschutz.
Stellen Sie sicher, daß keinerlei Überspannung (wie z.B. durch Gewitter verursacht) das Gerät erreichen kann. Andernfallsbestehtfür den Anwender die GefahreinesStromschlages.
Nicht ohne Abdeckung einschalten.
Betreiben Sie das Gerät nicht mit entfernten Gehäuse-Abdeckungen.
Betreiben Sie das Gerät nicht geöffnet.
Der Betrieb mit offenen oder entfernten Gehäuseteilen ist nicht zulässig. Nichts in entsprechende Öffnungen stecken (Lüfter z.B.)
Passende Sicherung verwenden.
Setzen Sie nur die spezifikationsgemäßen Sicherungen ein.
Vermeiden Sie ungeschützte Verbindungen.
Berühren Sie keine unisolierten Verbindungen o der Baugrup pen, während das Gerät in Betrieb ist.
DP800A User’s Guide V
RIGOL
Betreiben Sie das Gerä t n ic h t i m Fehlerfall.
Wenn Sie am Gerät einen Defekt vermuten, sorgen Sie dafür, bevor Sie das Gerät wieder betreiben, dass eine Untersuchung durch RIGOL autorisiertem Personal durchgeführt wird. Jedwede Wartung, Einstellarbeit en oder Austausch v on Teilen am Gerät, sowie am Zubehör dürfen nur von RIGOL autorisiertem Personal durchgeführt werd en.
Belüftung sicherstellen.
Unzureichende Belüftung kann zu Temperaturanstiegen und somit zu thermischen Schäden am Gerät führen. Stellen Sie deswegen die Belüftung sicher und kontrollieren regelmäßig Lüfter und Belüftungsöffnungen.
Nicht in feuc h te r Um g ebung betreiben.
Zur Vermeidun g von Kurzschluß im Geräteinne ren und Stromschlag betreiben Sie das Gerät bitte niemals in feuchter Umgebung.
Nicht in explosiver Atmosphäre betreiben.
Zur Ve rm e idung von Personen- und Sachs chä den ist es unumgä ngli ch, das Ger ät ausschließlich fernab jedweder explosiven At mosphäre zu betreiben.
Geräteoberflächen sauber und trocken halten.
Um den Einfluß von Staub und Feuchtigkeit aus der Luft auszuschließen, halten Sie bitte die Geräteoberflächen sauber und trocken.
Schutz gegen elektrostatische Entladung (ESD).
Sorgen Sie für eine elektrostatisch geschützte Umgebung, um somit Schäden und Funktionsstörungen durch ESD zu vermeiden. Erden Sie vor dem Anschluß immer Innen- und Außenleiter der V erbindungsleitung, um st atische Aufladung zu entladen.
Die richtige Verwendung desAkku.
Wenneine Batterieverwendet wird, vermeiden Sie hohe Temperaturen bzw. Feuer ausgesetzt werden. Bewahren Sie es außerhalbder Reichweitevon Kindern auf. UnsachgemäßeÄnde ru ng derBatterie (Anmerkung: Lithium-Batterie) kann zu einer Explosion führen. VerwendenSie nur von RIGOL angegebenenAkkus.
Sicherer Transport.
Transportieren Sie das Gerät sorgfältig (Verpackung!), um Schäden an Bedienelementen, Anschlüssen und anderen Teilen zu vermeiden.
Vermeiden Sie das einprägen von Strom und Spannung an den Testklemmen.
Das DP800A Power Supply kan n h ierdurch zer stört werden, keine akive Last. Das DP800A kann nur Strom und Spannun gen leifern.
VI DP800A User’s Guide

Sicherheits Begriffe und Symbole

WARNING DANGER
weist auf eine Ve rletzung oder Gefäh rdung hin, die sofort gesc hehen
WARNING
CAUTION
weist auf eine Verletzung oder Gefährdung hin und bedeutet, dass
Begriffe in diesem Guide:
Die Kennzeichnung WARNING beschreibt Gefahren q ue llen die leibliche Schäden oder den Tod von Personen zur Folge haben können.
CAUTION
Die Kennzeichnung Caution (Vorsicht) beschreibt Gefahrenquellen die Schäden am Gerät hervorrufen können.
Begriffe auf dem Produkt:
kann.
weist auf eine Verletzung oder Gefährdung hin, die möglicherweise
nicht sofort geschehen. eine mögliche Beschädigung des Instruments oder anderer
Gegenstände auftreten kann.
Symbole auf dem Produkt:
RIGOL
Gefährliche Spannung
Sicherheits­Hinweis
Schutz-erde Gehäusemasse Erde
DP800A User’s Guide VII
RIGOL
CAUTION
WARNING

Care and Cleaning

Care
Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions.
1. Disconnect the instrument from all power sources.
2. Clean the external surfaces of the i ns trume nt with a soft cloth dampened with mild detergent or water. When cleaning the LCD, take care to avoid scarifying it.
To avoid damage to the instrument, do not expose it to caustic liquids.
To avoid short-circuit resulting from moisture or personal injuries, ensure that the instrument is completely dry before connecting it to the power supply.
VIII DP800A User’s Guide
RIGOL

Environmental Consideratio ns

The following symbol indicates that this product complies with the WEEE Directives 2002/96/EC.
Product End-of-Life Handling
The equipment may contain substances that could b e ha rmful to the envi ronm ent o r human health. To avoid the release of such substances into the environment and avoid harm to human health, we recommend you to recycle thi s product appropriately to ensure that most materials are reused or recycled properly. Please contact your local authorities for disposal or recycling information.
DP800A User’s Guide IX
RIGOL
X DP800A User’s Guide
RIGOL

DP800A Series Overview

DP800A series is high-performance pr ogrammable linear DC power supply. DP800A series which provides clear user interface, superb performance specifications, various analysis functions as well as various communication interfaces can fulfill versatile test requirements.
Main Features: User-friendly Design:
3.5 inch TFT display, can display multiple parameters and states at the same
time
Support Chinese/English interface and Chinese/English in put metho d Novel and exquisite industrial design and easy operation Provide waveform display function to provide real-time and dynamic di splay of
the output voltage/current waveform, clearly showing the output state and tendency of the instrument in together with the digital display of the voltage, current and power values
Provide dial display function, indicating the current output state using the dial
pointer by simulating the traditional power display mode
Provide on-line help system for easy acquisition of help information
Multiple Safety Protection:
Provide overvoltage/overcurrent protection function; users can set the
overvoltage and overcurrent parameters to realize effective protection of the load
Provide seco nd ary over-temperature protection function to realize double
over-temperature protection of the software and hardware
Provide intelligent fan speed control function; judge and control the fan speed
automatically according to the working condition to effectively reduce the fan noise
Provide fan failure check and alar m fu nction Provide keyboard lock function to avoid misoperation
Various Functions and Superb Performance:
Multi-channel output; up to 200W total output power; the output of each
channel can be controlled independently
Superb load regulation rate and linear regulatio n r ate Provide ultra-low output ripples an d noise Provide timing output function and support infinite and specified number of
cycles of output
Provide track function to track the channel voltage setting value and the output
on/off status
Provide Sense function to automatically compensate f or the voltage drop caused
by the leads between the power supply and the load
Provide delay on/off output function and sup port infinite or specified number of
DP800A User’s Guide XI
RIGOL
cycles of channel on/off toggle
Provide built-in digital trigger to realize digital trigger input and trigger output
functions
Provide built-in on-line analyzer to perform on-line analysis of various statistic
parameters
Provide built-in monitor to monitor the output according to the user-defined
monitor condition
Provide built-in recorder to perform ba ck ground recor ding of the output st ate
after power-on according to certain record period
Provide de di cat ed p res et key to pe rf o rm one -key reset and one-key recall of the
commonly used output voltage and current configurations
Support serial and parallel output functions Support on-line self-test and manual calibration functions Provide store and recall function Support voltage and current linear programmable functions
Complete Interface Configurations and Flexible Control Method:
Standard configuration interfaces: USB HOST, USB DEVICE, LAN, RS232, Digital
I/O, Rear Output Interface (DP811A)
Support to extend a GPIB interface via the USB-GPIB interface converter
(option)
Support USB storage device (FAT32 format, fla sh memory) storage Support SCPI remote comman d control Conform to LXI Core 2011 Device instrument standard Provide standard 9 pin RS232 interface with flow control function Provide 4-wire digital I/O interface which supports the trigger input/output
function
XII DP800A User’s Guide
RIGOL
Tip

Document Overview

Chapter 1 Quick Start
Introduce the appearance and dimensi ons, front panel, rear panel as well as user interface of DP800A. In addition, it provides the detailed procedures of power connection, power-on inspection and f use replaceme nt as well as the meth od of rack mount installation of DP800A.
Chapter 2 Front Panel Ope r a tio n s
Introduce the function and operatio n method of each key at the front panel of DP800A in detail.
Chapter 3 Remote Control
Introduce how to realize the rem ote cont rol of the ins trument.
Chapter 4 Troubleshooting
Introduce the possible failures and their solutions when using DP800A.
Chapter 5 Specifications
List the specifications of DP800A.
Chapter 6 Appendix
Provide the accessories and options as well as warranty information of DP800A.
Index
Provide keyword se a rch to quickly locat e the desired information.
For the newest version of this manual, download it from RIGOL official website
www.rigol.com).
(
DP800A User’s Guide XIII
RIGOL
Model
Channel
Channel Output Voltage/Current
DP831A
3
8V/5A, 30V/2A, -30V/2A
Format Conventions in this Manual
1. Key
The function key at the front panel is denoted by the format of “Key Name (Bold) + Text Box” in the manual. For example, Utility denotes the “Utility” key.
2. Menu
The menu item is denoted in the following two modes in this manual. (1) The menu item can be denoted by the format of “Menu Word (Bold) +
Character Shading”. For example, System denotes the “System” item un der Utility.
(2) The menu item can be denoted by the screenshot of the menu key. For
example,
.
3. Operation Step
The next step of the operation is denoted by an arrow “” in the manual. For example, Utility System denotes pressing Utility at the front panel and then pressing System.
Content Conventions in this Manual
DP800A series programmable linear DC power supply includes the following models. In this manual, DP831A is taken as an example to illustrate the functions and operating methods of DP800A series.
DP832A 3 30V/3A, 30V/3A, 5V/3A DP821A 2 60V/1A, 8V/10A DP811A 1 Range 1 : 20V/10A; Range 2: 40V/5A
XIV DP800A User’s Guide
Contents RIGOL
Contents
Guaranty and Declaration ......................................................................... I
Safety Requirement ................................................................................ II
General Safety Summary ........................................................................... II
Safety Not ices and Symbol s ...................................................................... IV
Allgemeine Sicherheits Informationen ......................................................... V
Sicherheits Begriffe und Symbole ............................................................. VII
Care and Cleaning ................................................................................. VIII
Environmental Considerations ................................................................... IX
DP800A Series Overview ........................................................................ XI
Document Overview ............................................................................ XIII
Chapter 1 Quick Start ......................................................................... 1-1
General Inspection ................................................................................ 1-2
Appearance and Dime nsions ................................................................... 1-3
Front Panel ........................................................................................... 1-4
Rear Panel ........................................................................................... 1-13
To Connect to Power ............................................................................. 1-15
Power-on Inspection ............................................................................. 1-16
To Replace the Fuse ............................................................................. 1-16
User Interface ...................................................................................... 1-18
To Use the Built-in Help System ............................................................. 1-20
Chapter 2 Front Panel Operations ...................................................... 2-1
Constant Voltage Output ........................................................................ 2-2
Constant Current Output ........................................................................ 2-6
Power Supply Series and Parallel Connectio ns .......................................... 2-8
Power Supply Series Connection ....................................................... 2-8
Power Supply Parallel Connection ..................................................... 2-9
Track Function ..................................................................................... 2-10
To Enable the Track Function .......................................................... 2-10
To Track the On/Off Status of the Channel Output ............................. 2-13
Sense Working Mode ............................................................................ 2-14
Timer and Delayer ................................................................................ 2-16
To Set the Timer Parameters ........................................................... 2-17
To Enable the Timer ....................................................................... 2-26
To Set the Delay Parameters ........................................................... 2-27
To Enable the Delayer .................................................................... 2-31
Advanced Functions .............................................................................. 2-32
Recorder ....................................................................................... 2-33
Analyzer ........................................................................................ 2-34
Monitor ......................................................................................... 2-37
Trigger .......................................................................................... 2-38
DP800A User’s Guide XV
RIGOL Contents
Display Setting ..................................................................................... 2-42
Brightness .................................................................................... 2-42
Contrast ....................................................................................... 2-42
RGB Luminance ............................................................................. 2-42
Display Mo de ................................................................................ 2-42
User-defined Start-up Interface ....................................................... 2-44
Store and Recall ................................................................................... 2-46
Browser ........................................................................................ 2-47
File Type ....................................................................................... 2-47
Save ............................................................................................. 2-48
Read ............................................................................................ 2-50
Delete .......................................................................................... 2-50
Copy and Paste ............................................................................. 2-51
Utility .................................................................................................. 2-52
I/O Configuration .......................................................................... 2-53
System Setting .............................................................................. 2-58
System Informat i on ....................................................................... 2-60
System Language .......................................................................... 2-60
Test/Calibration ............................................................................. 2-60
Print ............................................................................................. 2-61
Preset Setting................................................................................ 2-62
Option .......................................................................................... 2-69
Key Locking ......................................................................................... 2-70
Chapter 3 Remote Control ................................................................. 3-1
Remote Control via USB .......................................................................... 3-2
Remote Control via LAN .......................................................................... 3-5
Remote Control via GPIB ......................................................................... 3-8
Remote Control via RS232 .................................................................... 3-10
Chapter 4 Troubleshooting ................................................................ 4-1
Chapter 5 Specifications .................................................................... 5-1
Chapter 6 Appendix ........................................................................... 6-1
Appendix A: Accessories and Options ....................................................... 6-1
Append i x B: Warranty ............................................................................. 6-2
Index ........................................................................................................ 1
XVI DP800A User’s Guide

Chapter 1 Quick Start RIGOL

Chapter 1 Quick Start
The contents of this chapter are as follows:
General Inspection Appearance and Dime nsions Front Panel Rear Panel To Connect to Power Power-on Inspection To Replace the Fuse User Interface To Use the Built-in Help System
DP800A User’s Guide 1-1
RIGOL Chapter 1 Quick Start

General Inspection

1. Inspect the packaging
If the packagi ng has been damaged, do not dispos e the damage d packaging or cushioning materials u ntil the shipment has been checked for completeness and has passed both el ectrical a nd mechanical tests.
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
2. Inspect the instrument
In case of any mechanical damage, m issing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
3. Check the accessories
Please check the accessories according to the packi ng l is t s. If t he accessories are damaged or incomplete, please contact your RIGOL sales representative.
1-2 DP800A User’s Guide
Chapter 1 Quick Start RIGOL

Appearance and Dimensions

For DP800A series, the di mensions of all models a re same. But t he design of the front and rear panels are not exactly the same (about the differences, please refer to “Front Panel” and “Rear Panel”). In this section, DP831A is taken as an example to introduce the appearance and dimensions of DP800A series (as shown in Figure 1-1 and Figure 1-2).
Figure 1-1 Front View Unit: mm
Figure 1-2 Side View Unit: mm
DP800A User’s Guide 1-3
RIGOL Chapter 1 Quick Start

Front Panel

In this section, DP831A (as shown in Figure 1-3) is taken as a n example t o intr oduce the front panel of DP800A series. The differences between different models are introduced separately.
1 2 3 4
11 10 9 8 7 6 5
Figure 1-3 DP831A Front Panel
Figure 1-4 DP811A F ront Panel
1-4 DP800A User’s Guide
Chapter 1 Quick Start RIGOL
Press this key to select CH1 and set the parameters of this channel,
Press this key and the prompt message asking whether to enable the
1. LCD
3.5 inches TFT display. It is used to display the system parameter setting, system output state, menu items, prompt messages, etc.
2. Channel (Range) Selection and Output Switch
For the multi-channel model, the function of this part is channel selection and output switch. For the single channel model (DP811A), the function of this part is range selection and output switch.
Multi-channel Model (take DP831A as the example):
such as voltage, current and overvoltage/overcurrent protection.
Press this key to select CH2 and set the parameters of this channel, such as voltage, current and overvoltage/overcurrent protection.
Press this key to select CH3 and set the parameters of this channel, such as voltage, current and overvoltage/overcurrent protection.
Press this key to enable or disable the output of the co rrespo ndi ng channel.
outputs of all the channels will be displayed. Press OK to enable the outputs of all the channels. Pressing this key again will disable the outputs of all the channels.
DP800A User’s Guide 1-5
RIGOL Chapter 1 Quick Start
Press this key to select the 40V/5A range. Users can set the parameters
Single Channel Model (DP811A):
Press this key to select the 20V/10A range. Users can set the parameters of the channel, such as voltage, current and overvoltage/overcurrent protect i on.
of the channel, such as voltage, current and overvoltage/overcurrent protection.
Press this key to enable or disable the output of the channel.
1-6 DP800A User’s Guide
Chapter 1 Quick Start RIGOL
3. Parameter In p ut Area
The parameter input area is as shown in the figure below. This area includes the direction keys (unit selection keys), numeric keyboard and knob.
(1) Direction keys and unit selection keys
Direction keys: move the cursor. When setting parameters, use the
up/down direction key to increase or reduce the value at the cursor.
Unit selection keys: whe n usi ng the nume ric ke yboa rd t o i nput par ameter s,
the keys are used to select the voltage units (V and mV) and the current
units (A and mA). (2) Numeric Keyboard
Ring-type numeric keyboard: include numbers 0-9 and the decimal point.
Press the corresponding key to directly input the number or decimal point. (3) Knob
When setting parameters, rotate the knob to increase or reduce the value at the cursor. When browsing the setting objects (timer parameters, delay parameters, filename input, etc.), rotate the knob to quickly move the cursor.
DP800A User’s Guide 1-7
RIGOL Chapter 1 Quick Start
keys.
Delete the character currently before the cursor.
4. Preset
Restore all the settings of the instrument to default values or recall the user-defined channel voltage/current configuration.
5. OK
Confirm the parameter setting. Press and hold this key to lock the front pane l keys; at this point,
6. Back
the front panel keys (except the output on/off key
of each channel) are not available. When the keyboard lock password is disabled, p ress an d h old t his k e y a gain t o u nlock the f ront panel keys. When the keyboard lock password is enabled, you need to input the correct password (2012) to unlock the front panel
When the instrument is in remote mode, p ress this k ey to return to local mode.
1-8 DP800A User’s Guide
Chapter 1 Quick Start RIGOL
(1)
(3)
7. Output Terminals
For DP800A series, the output terminals of different models are not exactly the same.
DP831A:
(1) (2)
DP821A:
DP811A:
(1) Channel output terminals: used to output the voltage and current of the
channel.
(2) Ground terminal: this terminal is connected to the instrument chassis and
ground wire (power cord ground terminal) and is in grounded state.
(3) Sense terminals: used to sense the actual voltage at the load to
compensate the voltage drop caused by the load leads.
DP800A User’s Guide 1-9
RIGOL Chapter 1 Quick Start
A
Connection methods of the output terminal:
B
Method 1: Connect the test lead to A of the output terminal.
Method 2: Rotate the outer nut of the output terminal counterclockwise and connect the test lead to B of the output terminal; then, rotate the outer nut of the output terminal clockwise. This connection method can eliminate the error caused by the resistance of the output terminal.
Note: Connect the posit ive terminal of the test lea d wi th the (+) terminal of the channel output and connect the negative terminal of the test lead with the (-) terminal of the channel output.
1-10 DP800A User’s Guide
Chapter 1 Quick Start RIGOL
Press this key to enter the display parameter setting interface.
Press this key to enter the advanced function setting interface.
Press this key to open the built-in help system and press the
8. Function Menu Area
Users can set the brightness, contrast, RGB luminance and display mode. Besides, you can also define the start-up interface.
Press this key to enter the file store and recall interface. You can save, read, delete, copy and paste files. The file types available for storage include state file, record file, timer file, delay file and bitmap file. The instrument supports internal and external storage and recall.
Press this key to enter the system utility function setting interface. Users can set the remote interface parameters, system parameters and print parameters. Besides, users can also calibrate the instrument, view system information and define the recall configuration of Preset.
Users can set the recorder, analyzer, monitor and trigger parameters.
Press this key to enter the timer and delayer interface. Users can set the timer and delayer parameters as well as turn on or off the timer and delayer.
desired key to get the corresponding help information. For the detailed introductions, refer to “
System”.
To Use the Built-in Help
DP800A User’s Guide 1-11
RIGOL Chapter 1 Quick Start
9. Display Mod e Switch/Return to the Main Interface
Switch between the current display mode and dial display mode. Besides, when the instrument is in a function interface (any
interface under Timer,
, Display, Store and Utility), press this key to exit the f unction interf ace and return to the main interface.
10. Menu Keys
The menu keys correspond to the menus above them. Pres s a n y menu key to selec t the corresponding menu.
11. Power Switch Key
Turn on or off the instrument.
1-12 DP800A User’s Guide
Loading...
+ 102 hidden pages