Rigol DP1308A, DP1116A, DP1000 Series Installation Manual

Page 1
RIGOL
Installation Guide
DP1000 Series Rack Mount Kit
RM-DP-1
RIGOL Technologies, Inc.
Page 2
RIGOL
Guaranty and Declaration
Copyright
© 2011 RIGOL Technologies, Inc. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL Technologies, Inc.
Publication Number
RKI06101-1110
Notices
RIGOL products are protected by patent law in and outside of P.R.C. RIGOL reserves the right to modify or change parts of or all the specifications and pricing
policies at company’s sole decision.
Information in this publication replaces all previously corresponding materials. RIGOL shall not be liable for losses caused by either incidental or consequential in connection
with the furnishing, use or performance of this manual as well as any information contained.
Any part of this document is forbidden to be copied or photocopied or rearranged without prior
written approval of RIGOL.
Product Certification
RIGOL guarantees this product conforms to the national and industrial standards in China. International standard conformance certification is in progress.
Contact Us
If you have any problem or requirement when using our products, please contact RIGOL Technologies, Inc. or your local distributors, or visit: www.rigol.com.
Page 3
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 2
Safety Terms and Symbols
Terms in this Manual. The following terms may appear in this manual:
WARNING
Warning statements indicate the conditions or practices that could result in injuries or loss of life.
CAUTION
Caution statements indicate the conditions or practices that could result in damage to this product or loss of data.
Terms on the Product. The following terms may appear on the product:
DANGER indicates a hazard may immediately happen. WARNING indicates potential hazard may happen. CAUTION indicates damage to the instrument or other devices connected to the instrument may
happen.
Symbols on the Product. The following symbols may appear on the product:
High
Voltage
Refer to Manual
Protective
Earth
Terminal
Chassis Ground
Terminal
Test
Ground
Terminal
Page 4
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 3
Product Overview
This product is used to rack mount the DP1000 series (DP1308A or DP1116A) programmable linear DC power to a standard 19-inch cabinet. Note that this manual takes DP1308A as an example for demonstration.
Parts List
No.
Name
Qty.
Part Number
Description
1-1
Top Guard Strip
1
RM-DP-1-01
1-2
Bottom Guard Strip
1
RM-DP-1-02
1-3
Front Guard Board
1
RM-DP-1-03
1-4
Instrument Fixing Part
2
RM-DP-1-04
1-5
Instrument Interconnector
2
RM-DP-1-05
1-6
Side Beam
2
RM-DP-1-06
1-7
Side Beam Fixing Part
2
RM-DP-1-07
1-8
Rear Support Stand
1
RM-DP-1-08
2-1
M4 Screw
14
RM-SCREW-01
M4X6 Phil-Slot Pan Head Machine Screw Nail
2-2
M6 Screw
16
RM-SCREW-02
M6X16 Phil-Slot Pan Head Machine Screw Nail
2-3
M6 Nut
16
RM-SCREW-03
M6X5 Square Machine Female Screw Contain Lock Blade
2-4
M4 Countersunk Head Screw
8
RM-SCREW-04
M4X6 Cross Recessed Countersunk Head Machine Screw Nail
Page 5
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 4
Figure 1: Parts of the Rack Mount Kit
2-1 2-2 2-3 2-4
Figure 2: Screw Models
Page 6
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 5
Space Requirement
The following requirements must be fulfilled by the machine cabinet in which the instrument is mounted:
1. Dimension of the machine cabinet must be standard 19-inch.
2. At least 4U (177.8 mm) space should be provided by the machine cabinet.
3. The depth of the machine cabinet should not be less than 460mm.
Figure 3: Dimension of the Instrument on the Rack
Page 7
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 6
Installation Instruction
Installation Tool
A PH2 Phillips Screwdriver is recommended for installation.
CAUTION
Only authorized operators can execute the installation operation. The instrument may be damaged or installed in rack incorrectly if the installation is not proper.
Installation Procedures
1. Remove the front and rear rubber covers: tear the front rubber cover off from the instrument,
then take off the two M4 screws at the rear panel, and at last remove the tilt tabs and the rear rubber cover.
Figure 4: Remove the Front and Rear Rubber Covers
!
Page 8
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 7
2. Install the joint parts: align the convexes on the fixing part and interconnector of the instrument
with the grooves on both sides of the instrument and insert them into the grooves, then fix them with four M4 countersunk head screws.
Figure 5: Install the Joint Parts
3. Interconnect two Instruments: place two instruments side by side, align the holes on the
interconnectors of the two instruments and fix them with 4 M4 screws.
Figure 6: Interconnect two Instruments
Page 9
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 8
4. Install the rear support stand: align the four holes on the rear support stand with the four holes
on the rear panels of the two instruments and fix the rear support board with 4 M4 screws.
Figure 7: Install the Rear Support Stand
5. Install the Fixing Accessories on the Cabinet: use 1 top guard strip, 1 bottom guard strip, 2 side
beams and 2 side beam fixing accessories to form a frame used to fix the instrument by aligning them with the corresponding holes on the cabinet and then fix them using 12 M6 screws, 12 M6nuts and 4 M4 screws. The correct hole positions are as pointed out by the black arrows in the figure below.
Figure 8: Install the Fixing Accessories on the Cabinet
Page 10
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 9
6. Put into the Cabinet: put the fixed instruments into a standard 19-inch cabinet and use 4 M6
screws, 4 M6 square nuts and four M4 screws to fix them.
Figure 9 Put into the Cabinet
Page 11
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 10
Installation Notice
This rack mount kit can also be used to fix one instrument into the standard 19-inch cabinet.
1. Install the front guard board: place a front guard board at the place of the other instrument and
use 2 M4 screws to fix it with the instrument installed.
Figure 10: Install the Front Guard Board
2. Put into the cabinet: put the fixed instrument into the standard 19-inch cabinet and fix it using 4
M6 screws, 4 M6 square nuts and 4 M4 screws.
Figure 11: Put into the Cabinet
Page 12
RIGOL
RM-DP-1 Rack Mount Kit Installation Guide 11
The rack occupies a height of 4U. The holes pointed out by the arrows are the installation holes and note that they must be aligned while installing.
Figure 12: Installation Hole Positions on the Rack