RIGOL DM3058 QuickStart Guide

Quick Guide RIGOL
Publication number QGA03109-1110 Feb. 2014
DM3058/DM3058E Digital Multimeter
© 2008 RIGOL Technologi es, Inc. All Rights Reserved
RIGOL
ENGLISH
Copyright
© 2008 RIGOL Technologies, Inc. All Rights Reserved. RIGOL products are protected by patent laws in and outside of
the P.R. China.
Information in this publication replaces all previous
corresponding material.
RIGOL reserve s the right to modify or change part of or a l l th e
specif ications and pricing policies at company’s sole decision.
NOTE: RIGOL is regis t ered trade ma rk of RIGOL Technologies, Inc.
Quick Guide for DM3058/DM3058E
I
RIGOL
ENGLISH
Safety Notice
Review the following safety precautions carefully before operating the instrument to avoid any personal injuries or damages to the instrument and any products connected to it.
The instrument should be serviced by qualified personnel only. Avoid Fire or Personal Injury. Use Proper Power Cord. Use t he power cord designed for the
instrument as authorized in your country only. Ground the Instrument. The instrument is grounded through the grounding conductor of the power cord. To avoid electric shock the instrument grounding conductor(s) must be grounded properly before making connections to the input or output terminals of the instrument. Observe all Terminal Ratings. To avoid fire or shock hazard, observe all ratings and marks on the instrument. Follow the user’s guide for further ratings information before making connections to the instrument. Do not Operate Without Covers. Do not operate the instrument with covers or panels removed. Use Proper Fuse. Use the fuse of the type, voltage and current ratings as specified for the instrument. Avoid Circuit or Wire Exposure. Do not touch exposed connections and components when power is on. Do not Operate With Suspected Failures. If suspected damage occurs with the instrument, have it inspected by qualified service personnel before further operations.
Do not Operate in Wet/Damp Conditions. Do not Operate in an Explosive atmosphere. Keep Product Surfaces Clean and Dry.
The disturbance test of all th e mo d els meet the limit values of A in the standard of EN 61326: 1997+A1+A2+A3, but can’t meet th e limit value s of B.
Input Terminal Protection Limitation
Protection limitation is defined for the input terminal:
1 Main input (HI and LO) terminal
HI and LO terminals are used for Voltage, Resistance,
Capacitance, Continuity, Frequency and Diodes measurement. Two protection limitations are defined:
1) HI-LO protection limitation: 1000VDC or 750VAC. It is the maximum measurable voltage. The limitation can be
II
expressed as 1000Vpk.
Quick Guide for DM3058/DM3058E
RIGOL
ENGLISH
2) LO-ground protection limitation. LO terminal can safely “float” 500Vpk r el ati ve to the ground.
The maximum protection limitation of HI terminal relative to the ground is 1000Vpk. Therefore, the sum of the “float” voltage and the measured voltage cannot exceed 1000Vpk.
2 Sampling (HI Sense and LO Sense) terminal
HI Sense and LO Sense are used for 4-Wire Resistance
Measurement. Two protection limitations are defined:
1) HI Sense-LO Sense protection limitation: 200Vpk.
2) LO Sense-LO protection limitation: 2Vpk.
3 Current input (I) terminal
I and LO terminal are used for current measurement. The
maximum current which go through the I terminal is limited t o 10A by the fuse on the rear panel.
NOTE: Voltage on the current input terminal corresponds to voltage on LO terminal. To obtain favorable protection, specified fuse should be used.
IEC Measurement Category II Overv oltage Protection
To protect against the danger of electric shock, DM3058/DM3058E provides overvoltage protection for line-voltage mains connections meeting both of the following conditions: 1 The HI and LO input terminals are connected to the mains
under Measurement Category II conditi ons, defined below.
2 The mains are limited to a maximum line voltage of 600VAC. WARNING: IEC Measurement Category II includes electrical
devices connected to mains at an outlet on a branch circuit. Such devices include most small appliances, test equipment, and other devices that plug into a branch outlet or socket. DM3058/DM3058E may be used to make measurements with the HI and LO inputs connected to mains in such devices (up to 600VAC), or to the branch outlet itself. However, DM3058/DM3058E may not be used with its HI and LO inputs connected to mains in permanently installed electrical devices such as the main circuit-breaker panel, sub-panel disconnected boxes, or permanently wired motors. Such devices and circuits are subject to overvoltage that may exceed the protection limits of DM3058/DM3058E.
Voltag es above 600VAC may be measured only in circuits
NOTE
that are isol ate d fro m mai ns . H owe ve r, t rans ie nt ov ervo lta ge is also present on circuits that are isolated from mains. DM3058/DM3058E is designed to safely withstand occasional transient overvoltage up to 4000Vpk. Do not use this equipment to measure circuits where transient overvoltage could exceed this level.
Quick Guide for DM3058/DM3058E
III
RIGOL
ENGLISH
! ! !
Hazardous
Safety
Protective Test
Chassis
!
!
Safety Terms and Symbols
Terms in This Guide. These terms may appear in this manual:
WARNING: Warning statements indicate the conditions
or practices that could result in injury or loss of life.
CAUTION: Caution statements indicate the conditions or practices that could result in damage to this product or other property.
CAT I (1000V) IEC Measurement Category II. The highest measureable voltage is 1000Vpk in the HI-LO terminal.
CAT II (600V): IEC Measurement Category II. Inputs may be con n ect ed to mains (up to 600VAC) under Category II over vo ltage conditions.
Terms on the Product. These terms may appear on the product: DANGER indicates an injury or hazard that may immediately
happen. WARNING indicates an injury or hazard that may not immediately happen. CAUTION indicates that a potential damage to the instrument or other property might occur.
Symbols on the Product. These symbols may appear on the product:
Voltage
IV
Warning
Earth Terminal
Quick Guide for DM3058/DM3058E
Ground
Ground
ENGLISH
RIGOL
Contents
Contents ................................................................................ V
Necessary Inspection ............................................................... 1
Handle Adjustment .................................................................. 4
To Connect Power Cord ............................................................ 5
To Connect Test Le ad .............................................................. 7
To Connect USB, RS2 32, LAN and GPIB Ports ............................ 13
Troubleshooting ..................................................................... 14
Contact Us ............................................................................. 15
Quick Guide for DM3058/DM3058E
V
Loading...
+ 16 hidden pages