RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC.
Publication Number
QGJ01100-1110
Notices
RIGOL products are covered by P.R.C. and foreign patents, issued and
pending.
RIGOL reserves the right to modify or change parts of or all the
specifications and pricing policies at the company’s sole decision.
Information in this publication replaces all previously released materials.
Information in this publication is subject to change without notice.
RIGOL shall not be liable for either incidental or consequential losses in
connection with the furnishing, use, or performance of this manual, as
well as any information contained.
Any part of this document is forbidden to be copied, photocopied, or
rearranged without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial
standards in China as well as the ISO9001:2008 standard and the
ISO14001:2004 standard. Other international standard conformance
certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this
manual, please contact RIGOL.
E-mail: service@rigol.com
Website: www.rigol.com
DL3000 Quick Guide 1
Page 4
RIGOL
English
1. Only the exclusive power
cord designed for the
instrument and authorized
for use within the local
country could be used.
2. Ensure that the instrument is
safely grounded.
3. Observe all terminal ratings.
4. Use proper overvoltage
protection.
5. Do not operate without
covers.
6. Do not insert objects into the
air outlet.
7. Use the proper fuse.
8. Avoid circuit or wire exposure.
9. Do not operate the instrument
with suspected failures.
10. Provide adequate ventilation.
11. Do not operate in wet conditions.
12. Do not operate in an explosive
atmosphere.
13. Keep instrument surfaces clean
and dry.
14. Prevent electrostatic impact.
15. Handle with caution.
WARNING
Indicates a potentially hazardous situation or practice which, if not
avoided, will result in serious injury or death.
CAUTION
Indicates a potentially hazardous situation or practice which, if not
avoided, could result in damage to the product or loss of
important data.
DANGER
It calls attention to an operation, if not correctly performed,
could result in injury or hazard immediately.
WARNING
It calls attention to an operation, if not correctly performed,
could result in potential injury or hazard.
CAUTION
It calls attention to an operation, if not correctly performed,
could result in damage to the product or other devices
connected to the product.
General Safety Summary
Safety Notices and Symbols
Safety Notices in this Manual:
Safety Terms on the Product:
2 DL3000 Quick Guide
Page 5
English
Safety Symbols on the Product:
Hazardous
Voltage
Safety
Warning
Protective Earth
Terminal
Chassis Ground
Test Ground
RIGOL
DL3000 Quick Guide 3
Page 6
RIGOL
English
CAUTION
To avoid damage to the instrument, do not expose it to caustic
liquids.
WARNING
To avoid short-circuit resulting from moisture or personal injuries,
ensure that the instrument is completely dry before connecting it
to the power supply.
Care and Cleaning
Care
Do not store or leave the instrument where it may be exposed to direct sunlight
for long periods of time.
Cleaning
Clean the instrument regularly according to its operating conditions.
1. Disconnect the instrument from all power sources.
2. Clean the external surfaces of the instrument with a soft cloth dampened
with mild detergent or water. When cleaning the LCD, take care to avoid
scarifying it.
4 DL3000 Quick Guide
Page 7
RIGOL
English
Tip
For the latest version of this manual, download it from RIGOL official
website (www.rigol.com).
Model
No. of Channels
Voltage
Current
Power
DL3021/
DL3021A
1
150 V
40 A
200 W
DL3031/
DL3031A
1
150 V
60 A
350 W
Document Overview
This manual introduces some basic information that you should know when you
use DL3000 for the first time. It contains the following contents: out-of-box
inspection method, product overview, turn-on checkout, and remote control
overview.
Format Conventions in this Manual
(1) The key on the front panel is denoted by the format of "Key Name (Bold)
+ Text Box" in the manual. For example, ON/OFF denotes the "ON/OFF"
key.
(2) Use the screen shot to indicate the key. For example, denotes the
Power key.
Content Conventions in this Manual
The number of channels and the rated values of input parameters for DL3000
are listed in the following table. Unless otherwise specified, this manual takes
DL3031A as an example to illustrate the functions and operation methods of the
DL3000 series.
DL3000 Quick Guide 5
Page 8
RIGOL
English
General Inspection
1. Inspect the packaging
If the packaging has been damaged, do not dispose the damaged
packaging or cushioning materials until the shipment has been checked
for completeness and has passed both electrical and mechanical tests.
The consigner or carrier shall be liable for the damage to the instrument
resulting from shipment. RIGOL would not be responsible for free
maintenance/rework or replacement of the instrument.
2. Inspect the instrument
In case of any mechanical damage, missing parts, or failure in passing the
electrical and mechanical tests, contact your RIGOL sales
representative.
3. Check the accessories
Please check the accessories according to the packing lists. If the
accessories are damaged or incomplete, please contact your RIGOL
sales representative.
6 DL3000 Quick Guide
Page 9
RIGOL
English
Control Keys
Channel
Terminals
Knob
Function Keys
USB Host
Power Key
LCD
Waveform Display Key
Input
Control Keys
Menu Keys
Application Key
System Function Keys
Product Overview
DL3000 is a cost-effective programmable DC electronic load with high
performance. With a user-friendly interface and superb performance
specifications, DL3000 provides various interfaces for remote communication to
meet your diversified test requirements. It can be widely used in various
industries, such as automotive electronics, aerospace, and fuel cells.
For descriptions of the front panel, refer to Figure 1; for descriptions of the rear
panel, refer to Figure 2; and for descriptions of the main interface (display
screen), refer to Figure 3.
DL3000 Quick Guide 7
Figure 1 Front Panel
Page 10
RIGOL
English
Air Outlet
Digital I/O
LAN Interface
AC Selector
AC Power Cord
Connector
Fuse
Fuse Rating
RS232
Interface
Voltage
Monitoring
Output
Terminal
Current
Monitoring
Output
Terminal
USB DEVICE
Company Logo
System Status Icons
Function
State
Actual Input
Values
Menu Item
Figure 2 Rear Panel
Figure 3 Main Interface
8 DL3000 Quick Guide
Page 11
RIGOL
English
AC Input Power
AC Selector
± (10% of AC input + 115 Vac), 50 Hz to 60 Hz
115
± (10% of AC input + 230 Vac) (max: 250 Vac),
50 Hz to 60 Hz
230
WARNING
To avoid electric shock, ensure that the instrument is correctly
grounded.
Turn-on Checkout
To Connect to Power Supply
Two kinds of AC power inputs are supported by DL3000 series electronic load.
When the DL3000 series is connected to different power sources, the AC
selector setting on its rear panel is different, as shown in Table 1.
Table 1 AC Input Power Specification and AC Selector Setting
Please strictly follow the steps below to connect the DL3000 electronic load to
the power supply.
1. Check the input power
Ensure that the AC power to be connected to the load conforms to the AC
input power requirement specified in Table 1.
2. Check the AC selector
Ensure that the AC selector setting (115 or 230) on the rear panel of the
load matches the actual AC input power (For the match relationship, refer
to Table 1).
3. Check the fuse
When leaving the factory, the load has installed a fuse that conforms to
the destination country standard. Please refer to the "fuse rating" on the
rear panel of the load to ensure that the fuse matches the actual AC input
power.
4. Connect the AC power
Plug the specified power cord available in the accessories into the AC
power supply connector of the instrument, and then connect the
instrument to the properly grounded AC power.
DL3000 Quick Guide 9
Page 12
RIGOL
English
CAUTION
Ensure that the AC selector setting on the rear panel of the
instrument matches the actual AC input voltage, otherwise, the
electronic load will be burned out.
CAUTION
Please pay attention to the positive and negative polarities of the
electronic load to avoid wrong connection. Otherwise, the load
will be burned out.
Tip
After powering off the electronic load, please wait for at least 1 s before you
power it on again.
To Power on the instrument
After the instrument is connected to the power source, press the Power key
at the left bottom of the front panel to power on the instrument. When the
instrument is turned on, it will undergo a self-test. If the instrument passes the
self-test, the welcome interface is displayed; otherwise, self-test failure
information will be displayed. At this time, please contact RIGOL distributors.
10 DL3000 Quick Guide
Page 13
RIGOL
English
To Use the Built-in Help System
The built-in help system provides help information for any key on the front
panel (except parameter input area) and menu keys, which are convenient for
you to get the descriptions of the function keys or menus, as shown in Figure 4.
Figure 4 Help Information Interface
1. Get the built-in help information
Press Help, and then "Help" will be displayed at the top of the interface,
being highlighted. At this time, press the corresponding function key or
menu key to enter the corresponding help information interface.
2. Page up/down operation
If the help information is displayed in several pages, press Previous to go
to the previous page or press Next to go to the next page. You can also
use the arrow keys or the knob to page up/down the help information.
3. Exit the current help information interface
When the help information is displayed, press OK to exit the current help
information interface and return to the previous interface.
DL3000 Quick Guide 11
Page 14
RIGOL
English
Parameter Setting Method
Most parameters can be set by operating the keys on the front panel. The
common setting methods are listed below. The setting method for certain
parameters is different from the methods below, refer to the relevant chapters
of this manual for the further explanation.
Method 1: Use the numeric keys
1. In the main interface, press the specified menu key to switch the
parameter focus; in the guide interface, use the arrow keys to switch the
parameter focus.
2. Enter a value by using the numeric key. While entering a name, press
to delete the unwanted character if necessary.
3. When setting resistance, press the specified menu key and select "Ω" or
"kΩ" to be the unit.
When setting period/width, press the specified menu key and select "ms"
or "s" to be the unit.
When setting frequency, press the specified menu key and select "Hz" or
"kHz" to be the unit.
When setting other parameters, press OK to confirm the input.
Method 2: Use the knob or the arrow keys
1. In the main interface, press the specified menu key to switch the
parameter focus.
2. Press the Left/Right arrow key to move the cursor to a desired position.
3. Press the Up/Down arrow key or rotate the knob to modify the value.
12 DL3000 Quick Guide
Page 15
RIGOL
English
Remote Control
DL3000 electronic load can be connected to the PC via the USB, LAN, GPIB, or
RS232 interface to build communication and realize remote control. The remote
control can be realized by using SCPI (Standard Commands for Programmable
Instruments) commands. DL3000 electronic load supports two ways of remote
control: user-defined programming and PC software (e.g. RIGOL Ultra Sigma).
When the instrument is in remote control, the icon is displayed on the
interface. The keypads on the front panel are locked. At this time, you can press
Local to exit the remote mode.
More Product Information
1. Obtain the device information
Press Utility to enter the system utility function interface, and then press
System Info. Select the "system information" tab to obtain the device
information, including the manufacturer, device model, software and
hardware version number, FPGA version number, Boot version number,
and the number of boot times, calibration date, and product serial
number.
2. Check the option installation status
Press Utility to enter the system utility function interface. Then, press
Option to view the installation status of all the options.
For more information about this instrument, refer to the relevant manuals by
logging in to the official website of RIGOL (www.rigol.com) to download them.
DL3000 User's Guide
operation methods, remote control methods, possible failures and solutions in
using the instrument, the technical specifications, and order information;
DL3000 Programming Guide
and programming instances of the instrument.
DL3000 Datasheet
the instrument.
: introduces the functions of the instrument and the
: provides detailed descriptions of SCPI commands
: provides the main features and technical specifications of
DL3000 Quick Guide 13