RIDGID RD8000 Series, RD80011 Series Operator's Manual

OPERATOR’S MANUAL
Manuel de l’opérateur
Manual del operador
PORTABLE GENERATOR
Générateur portable
Generador portátil
RD8000 / RD80011
Series / Série / Serie
To register your RIDGID
product, please visit:
http://register.RIDGID.com
Pour enregistrer votre
produit de RIDGID,
s’il vous plaît la visite:
http://register.RIDGID.com
Para registrar su producto
de RIDGID, por favor visita:
http://register.RIDGID.com
NEUTRAL BONDED TO FRAME
(CONNECTEUR NEUTRE RELIÉ AU CADRE, PUNTO NEUTRO CONECTADO AL MARCO)
safety. When properly cared for, it will give you years of rugged, trouble-free performance.
WARNING: To reduce the risk of injury, the user must read and understand the operator’s manual before using this
product. If you do not understand the warnings and instructions in the operator’s manual, do not use this product.
SAVE THIS MANUAL FOR FUTURE REFERENCE
Ce générateur portable a été conçu et fabriqué conformément à nos strictes normes de fiabilité, simplicité d’emploi et sécurité d’utilisation. Correctement entretenu, cet outil vous donnera des années de fonctionnement robuste et sans problème.
AVERTISSEMENT :
Pour réduire les risques de blessures, l’utilisateur doit lire et veiller à bien comprendre le manuel d’utilisation avant d’employer ce produit. Si tous les avertissements et toutes les consignes de sécurités et instructions du manuel d’utilisation ne sont pas bien compris, ne pas utiliser ce produit.
Su generador portàtil diseñado y fabricado de conformidad con nuestras estrictas normas para brindar fiabilidad, facilidad de uso y seguridad para el operador. Con el debido cuidado, le brindará muchos años de sólido funcionamiento y sin problemas.
ADVERTENCIA:
Para reducir el riesgo de lesiones, el usuario debe leer y comprender el manual del operador antes de usar este producto. Guarde este manual del operador y estúdielo frecuentemente para lograr un funcionamiento seguro y continuo de este producto.
CONSERVER CE MANUEL POUR
FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL PARA
FUTURAS CONSULTAS
See this fold-out section for all of the figures referenced
in the operator’s manual.
Consulter l’encart à volets afin d’examiner toutes les
figures mentionnées dans le manuel d’utilisation.
Consulte esta sección desplegable para ver todas las
figuras a las que se hace referencia en el manual del
operador.
ii
ENGINE SWITCH
OFF
ENGINE SWITCH
CIRCUIT BREAKER
START
ON
OFF
Fig. 3
ENGINE SWITCH
OFF
CIRCUIT BREAKER
A - Recoil starter grip (poignée du démarreur à
rappel, mango del arrancador retráctil) B - Air filter (filtre à air, filtro de aire) C - Choke lever (levier d’étrangleur, palanca del
anegador) D - Removable control panel (panneau de
commande amovible, panel de control
desmontable ) E - Fuel cap (bouchon de carburant, tapa del
tanque) F - Engine switch with switch key (commutateur
du moteur avec clé de interrupteur, interruptor
del motor con llave del interruptor)
Fig. 2Fig. 1
A
b
G - GenSmart™ monitoring system (système
de surveillance GenSmart™, sistema de monitoreo GenSmart™)
H - 120 volt, AC GFCI 20 amp receptacles (prises
120 V, C.A. GFCI 20 A, 120 V de CA GFCI 20 A receptáculos)
I - 120/240 volt, AC 30 amp receptacle (prise
120/240 V, C.A. 30 A, 120/240 V de CA 30 A receptáculo)
J - Off switch (commutateur d’arrêt, interruptor
de apagado)
K - AC circuit breaker (disjoncteur de C.A.,
disyuntor de circuito de CA)
L - Handle (poignée, mango)
A - Reset button (bouton de réinitialisation,
botón de reajuste)
B - Test button (bouton de test, botón de
prueba)
M- Fuel tank (réservoir de carburant, tanque de
combustible)
N - AC circuit breaker model RD80011 (disjoncteur
de C.A. modèle RD80011, disyuntor de circuito de CA modelo RD80011)
O
- Ground terminal (borne de terre, terminal de conexión a tierra)
P
- Battery (pile. batería)
Q - Oil cap/dipstick (bouchon/jauge d’huile,
tapa de relleno de aceite/varilla medidora de aceite)
R - Oil drainage bolt (vis de vidange d’huile,
perno de drenaje de aceite)
S - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
T - Fuel valve (robinet de carburant, válvula de
combustible)
G
H
F
I
J
K
L
m
e
S
d
O
c
p
N
b
A
T
Q
R
iii
10
9
2
3
1
4
7
6
5
8
11
6
12
Fig. 4
1 - Axle (essieu, eje) 2 - Wheel (roue, rueda) 3 - Flat washer (rondelle plate, arandela plana) 4 - Hitch pin (axe de blocage, pasador del
enganche) 5 - Screw, 2 in. (vis, 2 po; tornillo, 2 pulg.) 6 - Flat washer (rondelle plate, arandela plana)
Fig. 5
A
Fig. 6
c
e
A
b
b
F
A - Screw, 2 in. (vis, 2 po; tornillo, 2 pulg.) B - Flat washer (rondelle plate, arandela plana) C - Lock nut (écrou de blocage, tuerca de
seguridad) D - Leg with rubber foot (pied avec patin en
caoutchouc, pata con pie de goma) E - Frame (cadre, armazón) F - Screw, 1 in. (vis, 1 po; tornillo, 1 pulg.) G - Frame crossbar (barre stabilisatrice du cadre
travesaño del bastidor)
c
7 - Leg with rubber foot (pied avec patin en
caoutchouc, pata con pie de goma) 8 - Nut (écrou, tuerca) 9 - Control panel cord, 25 ft. (cordon de
panneau de commande 25 pi, cordón de
panel de control 25 pies)
b
A - Socket wrench (clé à douille, llave de casquillo) B - Combination wrench (clé mixte, llave de combinación)
Fig. 7 Fig. 9
b
A
c
G
A - Axle (essieu, eje) B - Wheel (roue, rueda) C - Flat washer (rondelle plate, arandela plana) D - Mount bracket (support de montage, soporte
de montaje) E - Hitch pin (goupille de sûreté, pasador de
enganche)
Fig. 8
A - Black wire (–) [fil noir (–), cable negro (–)] B - Battery bracket (support de pile, soporte de
la batería) C - Red wire (+) [fil rouge (+), cable rojo (+)] D - Positive (+) terminal [borne positive (+), tapa
del terminal positiva (+)] E - Negative (–) terminal [borne négative (–),
terminal negativa (–)]
d
10 - Engine lubricant (lubrifiant de moteur,
lubricante para motor) 11 - Screw, 1 in. (vis, 1 po; tornillo, 1 pulg.) 12 - Key (clé, llave)
A
b
e
A - Latch (loquet, pestillo) B - Removable control panel (panneau de
commande amovible, panel de control en distintas)
A
b
c
e
d
iv
ENGINE SWITCH
4-1/4 in.
5/8 in.
1/4 in.
Fig. 13Fig. 10
READ AND UNDERST 0HRS
PRESS AND HOLD RE 100 HRS
0 HRS
ENGINE SWITCH
OFF
ENGINE SWITCH
CIRCUIT BREAKER
START
ON
OFF
A
b
A - Oil cap/dipstick (bouchon/ jauge d’huile,
tapa de relleno de aceite/varilla medidora de aceite)
B - Oil fill hole (orifice de remplissage d’huile,
agujero de llenado de aceite)
Fig. 14
b
Fig. 17
A
c
b
A
Fig. 11
Fig. 12
A
A - Control panel cord, RDEC25 (cordon de
panneau de commande RDEC25, cordón de
A - Fuel cap (bouchon de carburant, tapa del
tanque de combustible)
B - Fuel tank (réservoir de carburant, tanque de
combustible)
panel de control RDEC25)
B - Twist-lock plug (prise à verrouillage, enchufe
de bloqueo de giro)
C - Twist-lock receptacle (prise à verrouillage par
rotation, receptáculo de fijación por giro)
Fig. 15
b
c
d
e
c
A
F
b
A
A - Handle (poignée, mango) B - Handle release knob (relâchez le bouton de
poignée, perilla de afloje del mango)
C - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
A - Engine on/off switch
interrupteur marche/arrêt de moteur, interruptor encendido/apagado del motor)
B - GenSmart™ monitoring system (système
de surveillance GenSmart™, sistema de monitoreo GenSmart™)
C - 120 volt AC GFCI 20 amp receptacles (prises
120 V C.A. 20 A, 120 V de CA GFCI 20 A
receptáculos)
Fig. 16
v
D - 120/240 volt AC 30 amp receptacle (prise
120/240 V C.A. 30 A, 120/240 V de CA 30 A receptáculo)
E - Off switch (commutateur d’arrêt, interruptor
de apagado)
F - AC circuit breaker (disjoncteur de C.A.,
disyuntor de circuito de CA)
Fig. 18
Fig. 20
Fig. 19
b
Fig. 21
Fig. 22
b
d
b
c
e
c
A
A
A
A - Nut (écrou tuerca) B - Battery bracket (support de pile, placa de
batería) C - Screw (vis, tornillo) D - Negative (-) terminal [borne positive (+),
terminal negativa (-)] E - Positive (+) terminal [borne positive (+), tapa
del terminal positiva (+)]
A - Fuel valve (robinet de carburant, válvula de
combustible) B - Off (arret, apagado) C - On (marche, encendido)
A - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
B - Joined area (partie jointe, área acoplada)
vi
Fig. 23
OFF
A
Fig. 25
A
A - Oil drainage bolt (oil drainage bolt, oil drainage
bolt)
Fig. 28
d
e
A - Fuse (fusible, circuito)
Fig. 24
c
A
A - Screw (vis, tornillo) B - Air filter cover (couvercle du filtre à air, tapa del
filtro de aire)
C - Filter element (élément du filtre, elemento
de filtro)
D - Air filter unit (unité de filtre à air, unidad del
filtro de aire)
b
d
Fig. 26
A - Spark plug cap (capuchon de bougie, tapa de
la bujía)
B - Spark plug (bougie, bujía)
A
b
Fig. 27
A
b
A - Fuel line (conduite de carburant, conducto de
combustible) B - Petcock (robinet de carburant, llave de
purga) C - Fuel valve (robinet de carburant, válvula de
combustible) D - Off (arret, apagado) E - On (marche, encendido)
c
Fig. 29
A
A - Carburetor drain screw (vis de vidange
du carburateur, tornillo de drenaje del
carburador)
Fig. 30
b
A
A - Fuel line (conduites de carburant ,conducto
de combustible)
B - Fuel filter (filtre à carburant, filtro de
combustible)
vii
TABLE OF CONTENTS
Introduction ..................................................................................................................................................................... 2
Important Safety Instructions .......................................................................................................................................3-4
Specific Safety Rules ...................................................................................................................................................... 4
Symbols .......................................................................................................................................................................5-7
Electrical .......................................................................................................................................................................7-9
Features .....................................................................................................................................................................9-10
Assembly ..................................................................................................................................................................10-12
Operation ..................................................................................................................................................................12-15
Maintenance .............................................................................................................................................................16-18
Troubleshooting ............................................................................................................................................................. 19
Warranty ...................................................................................................................................................................20-22
Parts Ordering / Service ...................................................................................................................................Back Page
INTRODUCTION
This product has many features for making its use more pleasant and enjoyable. Safety, performance, and dependability have been given top priority in the design of this product, making it easy to maintain and operate.
DANGER:
GROUNDING THE GENERATOR
To reduce the risk of shock or electrocution, generator must be properly grounded. The nut and ground terminal on the frame must always be used to connect the generator to a suitable ground source. The ground path should be made with #8 size wire. Connect the terminal of the ground wire between the lock washer and the nut, and tighten the nut fully. Connect the other end of the wire securely to a suitable ground source.
The National Electric Code contains several practical ways in which to establish a good ground source. If a steel or iron rod is used, it should be at least 5/8 in. diameter, and if a nonferrous rod is used, it should be at least 1/2 in. diameter and be listed as material for grounding. Drive the rod or pipe to a depth of 8 ft. If a rock bottom is encountered less than 4 ft. down, bury the rod or pipe in a trench.
All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be “Double Insulated.”
It is recommended to:
1. Use electrical devices with 3-prong grounded plugs.
2. Use an extension cord with a 3-pole receptacle and a 3-prong plug at opposite ends to ensure continuity of the ground protection from the generator to the appliance.
Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the generator is properly grounded.
2 — English
IMPORTANT SAFETY INSTRUCTIONS
Never start or run the engine inside a closed or partially
DANGER:
Carbon Monoxide. Using a generator indoors CAN
KILL YOU IN MINUTES. Generator exhaust contains high levels of carbon
monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.
Never use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air.
ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.
WARNING:
Read and understand all instructions. Failure to follow all instructions listed below may result in electrocution, fire, and/or carbon monoxide poisoning, which will cause death or serious injury.
WARNING:
National Electric Code requires generator to be grounded to an approved earth ground. Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
SAVE THESE INSTRUCTIONS
This manual contains important instructions for this product that should be followed during installation and maintenance of the generator and batteries.
Do not connect to a building’s electrical system unless
the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician.
Do not allow children or untrained individuals to use this
unit.
enclosed area. Breathing exhaust fumes will kill you.
Always wear eye protection with side shields marked to
comply with ANSI Z87.1 as well as hearing protection when operating this equipment.
Keep all bystanders, children, and pets at least 10 feet
away.
Wear sturdy and dry shoes or boots. Do not operate while
barefoot.
Do not operate generator when you are tired or under the
influence of drugs, alcohol, or medication.
Keep all parts of your body away from any moving parts
and all hot surfaces of the unit.
Do not touch bare wire or receptacles. Do not use generator with electrical cords which are worn,
frayed, bare, or otherwise damaged.
Before storing, allow the engine to cool and drain fuel
from the unit.
Do not operate or store the generator in rain, snow, or
wet weather.
Store the generator in a well-ventilated area with the
fuel tank empty. Fuel should not be stored near the generator.
Empty fuel tank, close fuel valve, and restrain the unit
from moving before transporting in a vehicle.
Allow engine to cool for five minutes before refueling. To reduce the risk of fire and burn injury, handle fuel with
care. It is highly flammable.
Do not smoke while handling fuel. Store fuel in a container approved for gasoline. Position the unit on level ground, stop engine, and allow
to cool before refueling.
Loosen fuel cap slowly to release pressure and to keep
fuel from escaping around the cap.
Tighten the fuel cap securely after refueling. Wipe spilled fuel from the unit. Never attempt to burn off spilled fuel under any circum-
stances.
Generators vibrate in normal use. During and after the
use of the generator, inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration. Have damaged items repaired or replaced as necessary. Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades.
For power outages, permanently installed stationary gen-
erators are better suited for providing back-up power to the home. Even a properly connected portable generator can become overloaded. This may result in overheating or stressing the generator components, possibly leading to generator failure.
3 — English
IMPORTANT SAFETY INSTRUCTIONS
Use only authorized replacement parts and accessories
and follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of shock or injury.
SPECIFIC SAFETY RULES
WARNING:
When this generator is used to supply a building wiring system: generator must be installed
by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code. The generator shall be connected through a transfer switch that switches all conductors other than the equipment grounding conductor. The frame of the generator shall be connected to an approved grounding electrode. Failure to isolate the generator from power utility can result in death or injury to electric utility workers.
Exhaust contains poisonous carbon monoxide, a color-
less, odorless gas. Breathing exhaust can cause loss of consciousness and can lead to death. If running in a confined or partially-enclosed area, the air may contain a dangerous amount of carbon monoxide. To keep exhaust fumes from building up, always provide adequate ventila­tion.
Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick, dizzy, or weak while using the generator, shut it off and get to fresh air immediately. See a doctor. You may have carbon monoxide poisoning.
Place the generator on a flat, stable surface with a slope
of no more than 4°.
Operate outdoors in a well-ventilated, well-lit area isolated
from working areas to avoid noise interference.
Operating the generator in wet conditions could result in
electrocution. Keep the unit dry.
Keep the generator a minimum of 3 feet away from all
types of combustible material.
Do not operate generator near hazardous material.
Do not operate generator at a gas or natural gas filling
station.
Do not touch the muffler or cylinder during or immediately
after use; they are HOT and will cause burn injury.
This generator has a neutral bonded condition. This
means the neutral conductor is electrically connected to the frame of the machine.
Maintain the unit per maintenance instructions in this
Operator’s Manual.
Inspect the unit before each use for loose fasteners, fuel
leaks, etc. Replace damaged parts.
Do not connect to a building’s electrical system unless a
transfer switch has been properly installed by a qualified electrician.
Do not allow the generator’s gas tank to overflow when
filling. Fill to 1 in. below the top neck of the gasoline tank to allow for fuel expansion. Do not cover the fuel tank cap when the engine is running. Covering the fuel tank cap during use may cause engine failure and/or damage to the tool.
Do not smoke when filling the generator with gasoline.
Shut down the engine and allow to cool completely before
adding gasoline or lubricant to the generator.
Do not remove the oil dipstick or the fuel tank cap when
the engine is running.
Pay close attention to all safety labels located on the
generator.
Keep children a minimum of 10 feet away from the gen-
erator at all times.
The unit operates best in temperatures between 23°F and
104°F with a relative humidity of 90% or less.
Specific modifications for high-altitude performance are
needed if the generator will always be operated at alti­tudes above 5,000 feet. Contact your nearest authorized service center for more information and to have these modifications performed.
Operating voltage and frequency requirement of all
electronic equipment should be checked prior to plug­ging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To reduce the risk of damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.
When battery pack is not in use, keep it away from
other metal objects like paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you loan someone this product, loan them these instructions also.
4 — English
SYMBOLS
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
WARNING:
CAUTION:
CAUTION:
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter­pretation of these symbols will allow you to operate the product better and safer.
Indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.
(Without Safety Alert Symbol) Indicates a situation that may result in property damage.
SYMBOL NAME DESIGNATION/EXPLANATION
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
To reduce the risk of injury, user must read and understand operator’s manual before using this product.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Electric Shock
Toxic Fumes
Fire/Explosion
Hot Surface
Lifting Hazard
Ground
Electrocution
Failure to use in dry conditions and to observe safe practices can result in electric shock.
Running generator gives off carbon monoxide, an odorless, color­less, poison gas. Breathing carbon monoxide can cause nausea, fainting, or death.
Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
To reduce the risk of injury or damage, avoid contact with any hot surface.
To reduce the risk of serious injury, avoid attempting to lift the generator alone.
Consult with local electrician to determine grounding requirements before operation.
Failure to properly ground generator can result in electrocution, especially if the generator is equipped with a wheel kit.
5 — English
SYMBOLS
DANGER
DANGER
PELIGRO
L’utilisation d’une génératrice à l’intérieur PEUT VOUS TUER ENQUELQUES MINUTES.
Les génératrices produisent du monoxyde de carbone, un gaz mortel incolore et inodore.
NE JAMAIS utiliser à l’intérieur d’une maison ou d’un garage,MÊME SI les portes et les fenêtres sont ouvertes.
Utiliser uniquement À L’EXTÉRIEUR et loin des fenêtres, des portes et des évents.
Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS.
Los gases de escape del generador contienen monóxido de carbono. Es un veneno que no puede verse ni olerse.
NUNCA lo use dentro de su hogar o del garaje, INCLUSO con las puertas y las ventanas abiertas.
Sólo utilícelo AL AIRE LIBRE y lejos de ventanas, puertas y respiraderos.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
V Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watt Power hrs Hours Time gal Gallon Volume
qt Quart Volume
SAFETY LABELS
The information on this page can be found on the generator. For your safety, please study and understand all of the labels before starting the generator.
If any of the labels come off the unit or become hard to read, contact an authorized service center for replacement.
You WILL be KILLED or SERIOUSLY HURT if you do not follow the
Operator’s Manual instructions.
Risk of Fire. Do not add fuel while the product is operating. Generator is a potential source of electric shock. Do not expose to
moisture, rain, or snow. Do not operate with wet hands or feet.
Exhaust contains poisonous carbon monoxide gas that can cause
unconsciousness or DEATH. Operate in well-ventilated, outdoor areas away from open windows or doors.
Failure to properly ground generator can result in electrocution, espe-
cially if the generator is equipped with a wheel kit.
Do not expose to rain or use in damp locations. Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust
contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are
open.
Only use OUTSIDE and far away from windows, doors, and vents.
HOT SURFACE WARNING
Do not touch the muffler or alumi­num cylinder of the engine. They are very HOT and will cause severe burns. Don’t put any flammable or combustible materials in the direct path of the exhaust.
FUEL WARNING
No smoking when filling with gaso­line. Do not overfill. Full level is 1 in. below the top of the fuel neck. Stop the engine for five minutes before refueling to avoid the heat from the muffler igniting fuel vapors.
6 — English
SYMBOLS
ENGINE LUBRICANT WARNING
You must add lubricant before first operating the generator. The oil reservoir capacity is 1.1 qt. Always check the lubricant level before each operation. The lubricant level should always register between the hatched areas on the dipstick. The unit is equipped with a sensor which will automatically shut off the engine if the lubricant level falls below a safe limit.
GROUNDING WARNING
National Electric Code requires generator to be grounded to an approved earth ground.
ELECTRICAL
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load. Inadequate size cables can cause a voltage drop, which can damage the appliance and overheat the cord.
Current in
Amperes
2.5 300 600 1000 ft. 600 ft. 375 ft. 250 ft. 5 600 1200 500 ft. 300 ft. 200 ft. 125 ft.
7.5 900 1800 350 ft. 200 ft. 125 ft. 100 ft.
10 1200 2400 250 ft. 150 ft. 100 ft. 50 ft. 15 1800 3600 150 ft. 100 ft. 65 ft. 20 2400 4800 175 ft. 125 ft. 75 ft. 25 3000 6000 150 ft. 100 ft. 30 3600 7200 125 ft. 65 ft. 40 4800 9600 90 ft.
ELECTRIC MOTOR LOADS
It is characteristic of common electric motors in normal operation to draw up to six times their running current while start­ing. This table may be used to estimate the watts required to start “Code G” electric motors; however, if an electric motor fails to start or reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check the requirements of the tool or appliance being used compared to the rated output of the generator.
Load in Watts Maximum Allowable Cord Length
At 120V At 240V #8 Wire #10 Wire #12 Wire #14 Wire #16 Wire
Motor Size (H.P.) Running Watts
1/8 275 600 850 1200 1/6 275 600 850 2050 1/4 400 850 1050 2400
1/3 450 975 1350 2700 1/2 600 1300 1800 3600
3/4 850 1900 2600
1 1100 2500 3300
Watts Required to Start Motor
Repulsion Induction Capacitor Split Phase
7 — English
ELECTRICAL
CONTROL PANEL CORD
See Figure 1.
The 25-ft. control panel cord (Model RDEC25) has a 240 Volt, 20 Amp twist lock plug on one end and a 240 Volt, 20 Amp twist lock receptacle on the other end. It also has a 12 Volt DC engine control connector on each end. When using this cord, the removable control panel can provide power through the 2 x 120 Volt duplex GFCI outlets on the control box.
CAUTION:
Use only with RDEC25 control panel cord. Do not exceed separation length of 75 ft. or a combination of three RDEC25 control panel cords.
CAUTION:
Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.
GROUND FAULT CIRCUIT INTERRUPTER
See Figure 2.
The 20 amp, 120 volt receptacles on the generator are pro­tected by a Ground Fault Circuit Interrupter (GFCI), which guards against the hazards of ground fault currents. An example of ground fault current is the current that would flow through a person who is using an appliance with faulty insu­lation and, at the same time, is in contact with an electrical ground such as a plumbing fixture, wet floor, or earth.
GFCI receptacles do not protect against short circuits, over­loads, or shocks.
The GFCI receptacles can be tested with the TEST and RESET buttons.
To test:
Depress the TEST button. This should cause the Reset
button to pop out. To restore power, depress the RESET button. Perform this test monthly to ensure proper operation of the
GFCI. If the generator is stored outdoors, unprotected from the weather, test the GFCI receptacle before each use.
GENERATOR CAPACITY
Make sure the generator can supply enough continuous (run­ning) and surge (starting) watts for the items you will power at the same time. Follow these simple steps.
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This is the amount of power the generator must produce to keep the items running. See the wattage reference chart at right.
3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Example:
Estimated*
Tool or Appliance
Quartz Halogen Work Light
Reciprocating Saw Electric Drill Circular Saw
Total Continuous (Running) Watts 3960 Plus Highest Additional Surge Watts + 2300
Equals Total Generator Output Required 6260
Continuous
(Running) Watts
1000 0
960 +960 600 +900
1400 +2300
3960 Total
Running Watts
Estimated*
Additional Surge
(Starting) Watts
+2300 Highest
Surge Watts
POWER MANAGEMENT
To prolong the life of the generator and attached devices, it is important to take care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting its engine. The correct and safe way to manage generator power is to sequentially add loads as follows:
1. With nothing connected to the generator, start the engine as described later in this manual.
2. Plug in and turn on the first load, preferably the largest load you have.
3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take special care to consider surge loads in generator capacity as previously described.
8 — English
ELECTRICAL
CAUTION:
Do not overload the generator’s capacity. Exceeding the generator’s wattage/amperage capacity can damage the generator and/or electrical devices connected to it.
FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .......................................... Subaru, EX40 OHC
Bore x Stroke .............................................89 mm x 65 mm
Cooling System ...................................................Forced Air
Compression Ratio ...................................................... 8:1:1
Starting System .........................................Recoil & Electric
Ignition System ........................................................... T.M.I.
Spark Plug .......................................................NGK BR6HS
Engine Lubricant Volume...........................................1.2 qt.
Fuel Volume ................................................................ 8 gal.
Estimated*
Tool or Appliance
DIY/Job Site Quartz Halogen Work Light 1000 0
Airless Sprayer − 1/3 HP 600 +1200 Reciprocating Saw 960 +960
Electric Drill − 1/2 HP 600 +900 Circular Saw − 7-1/4 in. 1400 +2300 Miter Saw − 10 in. 1800 +1800 Planer/Jointer − 6 in. 1800 +1800 Table Saw/Radial Arm Saw −
10 in. Air Compressor − 1 HP 1600 +4500
*Wattages listed are approximate. Check tool or equipment for actual wattage.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps .................................................. 66.7 A / 33.3A
Rated Output ..........................................................8,000 W
Maximum Output..................................................10,000 W
Rated Frequency ........................................................60 Hz
DIMENSIONS
Length ....................................................................... 31 in.
Width .......................................................................... 30 in.
Height ......................................................................... 27 in.
Weight .................................................................... 256 lbs.
Running
Watts
2000 +2000
Estimated*
Additional
Starting Watts
KNOW YOUR GENERATOR
See Figure 3.
The safe use of this product requires an understanding of the information on the product and in this operator’s manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all operating features and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator against electrical overload. The circuit breaker may be reset by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn into the unit during operation.
CHOKE LEVER
The choke lever is used when starting the engine.
ENGINE SWITCH WITH SWITCH KEY
The engine switch is used in combination with the recoil starter grip to start the generator. To turn the engine off, turn the engine switch key to “OFF”.
CONTROL PANEL CORD
The 25-ft. control panel cord (Model # RDEC25) has a 120/240 Volt, 20 Amp twist lock plug and a 12 Volt DC engine control connector on each end. When using this cord with the removable control panel, appropriate equipment can be powered through the 2 x 120 Volt duplex GFCI outlets on the removable control panel.
9 — English
FEATURES
FUEL TANK
The fuel tank has a capacity of 8 gallons.
FUEL VALVE
The flow of fuel through the generator is controlled by the position of the fuel valve.
GenSmart™ MONITORING SYSTEM
The GenSmart monitoring system tracks usage and load and alerts the operator when periodic engine maintenance is recommended.
NOTE: GenSmart™ load indicators monitor the load only for the 120 Volt, 20 Amp GFCI outlets on the removable control panel. It does not measure load on the 240 Volt, 30 Amp outlet.
GROUND TERMINAL
The ground terminal is used to assist in properly ground­ing the generator to help protect against electrical shock. Consult with a local electrician for grounding requirements in your area.
OFF SWITCH
To turn the engine off, press and hold the off switch until the engine stops or turn the ignition switch to the OFF position.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the generator when necessary.
OIL DRAINAGE BOLT
When changing the engine lubricant, the oil drainage bolt is loosened to allow old engine lubricant to be drained.
RECEPTACLES
The following single phase, 60 Hz outlets on the control panel can be used for operating appropriate equipment, electrical lighting, tools, and motor loads: 2 x 120 Volt duplex GFCI 20 Amp receptacles, and one 240 Volt AC, 30 Amp receptacle. A 240 Volt AC, 20 Amp receptacle plugged into the side of the removable control panel is available when the panel is detached.
RECOIL STARTER GRIP
The recoil starter is pulled to start the machine.
REMOVABLE CONTROL PANEL
The removable control panel can be wall-mounted for use with the control panel cord for operation in a variety of locations.
ASSEMBLY
UNPACKING
This product requires assembly. Carefully cut the box down the sides then remove the
machine and any accessories from the box. Make sure that all items listed in the packing list are included.
NOTE: This machine is heavy and requires a minimum of
two people to lift. To avoid back injury, lift with your legs and not your back.
WARNING:
Do not use this product if any parts on the Loose Parts List are already assembled to your product when you unpack it. Parts on this list are not assembled to the product by the manufacturer and require customer installation. Use of a product that may have been improperly assembled could result in serious personal injury.
Inspect the product carefully to make sure no damage
occurred during shipping.
Do not discard the packing material until you have carefully
inspected and satisfactorily operated the product.
If any parts are damaged or missing, please call
1-866-539-1710, for assistance.
WARNING:
If any parts are damaged or missing do not operate this product until the parts are replaced. Use of this product with damaged or missing parts could result in serious personal injury.
WARNING:
Do not attempt to modify this product or create accessories not recommended for use with this product. Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury.
WARNING:
Do not attempt to operate the generator until assembly is complete. Failure to comply could result in possible serious personal injury.
10 — English
ASSEMBLY
LOOSE PARTS LIST
See Figure 4.
The following items are included with the generator:
Key No. Description Qty.
1 Axle ......................................................................2
2 Wheel ...................................................................2
3 Flat Washer (5/8 in.) .............................................2
4 Hitch Pin ..............................................................2
5 Screw (1/4-20 x 2 in., Hex Hd.) ...........................4
6 Flat Washer (1/4 in.) .............................................6
7 Left and Right Legs with Rubber Feet .................2
8 Nut (1/4-20 Self-Locking Nut) .............................6
9 Control Panel Cord, 25 ft. ....................................1
10 Engine Lubricant..................................................1
11 Screw (1/4-20 x 1 in., Hex Hd.) ...........................2
12 Key.......................................................................1
Operator’s Manual (not shown) ...........................1
TOOLS NEEDED
See Figure 5.
The following tools (not included or drawn to scale) are needed for assembly:
7/16 in. Socket Wrench 7/16 in. and 8 mm Combination Wrench
NOTE: Do not put fuel or lubricant in the generator before installing the legs and wheels.
INSTALLING LEGS
See Figure 6.
Locate the following items: Left and right legs with rubber feet 6 flat washers 6 lock nuts 4 screws (2 in.) 2 screws (1 in.) Raise the front end of the generator, where the engine is
located, high enough to gain access to the frame bottom; securely position props underneath to support.
Position a leg over the holes on each side of the frame
support. The tab on the leg should face the inside of the generator frame.
Insert each 2 in. screw through a flat washer and insert
the screws through the two holes in the frame and the leg.
Fasten the screws by installing a self-locking nut over
each screw on the inside of the frame. Tighten the nut securely.
Insert a 1 in. screw through a flat washer, the hole in the
frame crossbar, and then through the hole in the leg tab. Install a self-locking nut and tighten to secure.
Repeat with remaining leg.
INSTALLING THE WHEELS
See Figure 7.
Wheels are provided to assist in moving the generator to the desired location and should be installed on the side opposite the recoil starter.
Locate the following items: 2 axles 2 washers (5/8 in.) 2 hitch pins 2 wheels Raise the handle end of the generator
gain access to the frame bottom; securely position props underneath to support.

Insert an axle through the center of the wheel.

Place a washer on the axle, then slide the axle through the bracket on the frame.
Slide the hitch pin through the hole in the axle and make
sure it is secure.
Repeat the process on the other side to install second
wheel.
CONNECTING BATTERY
See Figure 8.
The battery cables must be connected before the electric start feature of the generator can be operated.
Connect the red wire to the positive (+) terminal first,
then connect the black wire to the negative (−) terminal
using the bolts, nuts, and washers provided. Make sure all connections are tight.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause sparks, damage to the battery or generator, or even burns or explosions.
Cover the terminals with the rubber covers. When removing the battery for replacement: remove the
nut and bolt first from the negative (black) post, then from the positive (red) post, being careful not to short across the terminals. Always abide by the safety warnings provided with the battery. Remove the battery and dispose of according to local and state regulations.
WARNING:
WARNING:
11 — English
high enough to
To reduce the risk of electrocution or explosion, do not short circuit the battery terminals or charge in a sealed container. Keep sparks and flame away.
Keep metal objects away from the battery terminals. Metal objects can make a connection from one terminal to another. Shorting the battery terminals together may cause sparks, burns, or a fire.
ASSEMBLY
REMOVABLE CONTROL PANEL
See Figure 9.
To detach the removable control panel from the generator:
Turn off the generator. Loosen the latch on the removable control panel and pull
the control panel forward.
Disconnect the twist-lock plug and the 12V engine control
connector on the back of the control panel.
OPERATION
INSTALLING A WALL MOUNT FOR THE REMOVABLE CONTROL PANEL
See Figure 10 - 11
The removable control panel can be removed from the generator and wall-mounted in another location before re­connecting it to the generator.
To wall-mount the removable control box:
Screws or nails for hanging the box should be spaced
4-1/4 in. from center to center.
Mark the 4-1/4 in. measurement on a wall stud or other
sturdy wood surface.
Drill holes and insert the screws; tighten the screws
securely into the wood. If using nails, the nail head should be large enough to hold the control panel securely.
NOTE: There should be at least 5/8 in. of the screw or nails
protruding from the wood piece for hanging the box.
Hang the box on the screws or nails, making certain it is
secure.
DANGER:
Carbon Monoxide. Using a generator indoors
WILL CAN YOU IN MINUTES. Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even if you cannot smell the exhaust, you could be breathing CO.
Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air.
ONLY use a generator outdoors and far away from open
windows, doors, and vents. These openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.
DANGER:
Failure to properly ground generator can result in electrocution, especially if the generator is equipped with a wheel kit. National Electric Code requires generator to be properly grounded to an approved earth ground. Call an electrician for local grounding requirements.
WARNING:
Do not allow familiarity with this product to make you careless. Remember that a careless fraction of a second is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not recommended by the manufacturer of this product. The use of attachments or accessories not recommended can result in serious personal injury.
12 — English
OPERATION
APPLICATIONS
This generator is designed to supply electrical power for operating compatible electrical lighting, appliances, tools, and motor loads.
BEFORE OPERATING THE UNIT
Only use OUTSIDE and far away from windows, doors,
and vents.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Always position the generator on a flat firm surface.
CAUTION:
Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure.
RAISING AND LOWERING THE HANDLE
See Figure 12.
To raise the handle (for moving the generator): pull the
handle up until the handle release knob snaps into lock­ing position and insert the handle lock pin to secure the handle in place.
To lower the handle (for storing or transporting the gen-
erator): remove the handle lock pin, then pull the handle release knob out and lower the handle to the down posi­tion.
Never use the handle to lift the generator. The handle should only be used for moving the unit by rolling it on its wheels.
CHECKING/ADDING LUBRICANT
See Figure 13.
Engine lubricant has a major influence on engine perfor­mance and service life. For general, all-temperature use, SAE 10W-30 is recommended. Always use a 4-stroke motor lubricant that meets or exceeds the requirements for API service classification SJ.
This engine comes with a feature that will shut off the engine when a specific oil level is not maintained. The engine will not restart until an appropriate oil level is reached.
NOTE: Non-detergent or 2-stroke engine lubricants will damage the engine and should not be used.
Unscrew the oil cap/dipstick and remove. Wipe dipstick clean and insert in hole. Do not rethread. Remove dipstick again and check lubricant level. Lubri-
cant level should fall between the hatched areas on the dipstick.
If level is low, add engine lubricant until the fluid level rises
to the upper portion of the dipstick.
Replace and secure the oil cap/dipstick.
CHECKING/ADDING FUEL
See Figure 14.
Remove the fuel cap. Fill the fuel tank to 1 in. below the top of the fuel neck. Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane rating of 86 or higher. Never use old, stale, or contaminated gasoline, and do not use an oil/gas mixture. Do not allow dirt or water into the fuel tank. Do not use E85 fuel.
USING FUEL STABILIZER
Fuel gets old, oxidizes, and breaks down over time. Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow fuel stabilizer manufacturer’s directions for correct ratio of stabilizer to fuel.
Add stabilizer to fuel tank, then fill with gasoline following
previous instructions.
NOTE: Fuel stabilizer and gasoline can be mixed prior
to filling the tank by using a gas can or other approved fuel container and shaking gently to combine.
Replace and secure the fuel tank cap. Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
DO NOT USE E85 FUEL. IT WILL VOID YOUR WAR­RANTY.
NOTE: Fuel system damage or performance problems
resulting from the use of an oxygenated fuel containing more than the percentages of oxygenates stated below are not
covered under warranty. Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) or 15% ethanol by volume (commonly referred to as E15) are acceptable. E85 is not.
CAUTION:
On a level surface with the engine off, check the lubricant level before each use of the generator.
REMOVABLE CONTROL PANEL
See Figure 15.
The removable control panel can be wall-mounted and con­nected to the generator with the 25-ft. control panel cord (Model # RDEC25) provided with the product.
The generator can be turned on or off from the removable control panel or using the off switch key on the unit.
NOTE: The off switch is an on/momentary off switch. You must push the switch and hold it in until the engine has fully stopped.
13 — English
OPERATION
The removable control panel has two 120V duplex GFCI power outlets with outlet covers. Each duplex outlet has a Test and a Reset push button.
NOTE: The GFCI outlets may be shown without their covers for clearer instruction of this feature’s operation.
Use only with RDEC25 control panel cord. Do not exceed separation length of 75 ft. or a combination of three RDEC25 control panel cords.
GENSMART™ DIGITAL DISPLAY
See Figure 16.
The GenSmart™ monitoring system has the following fea­tures:
Load Indicator
Measures the wattage output of the 2 x 120 Volt duplex GFCI outlets located on the removable control panel. GenSmart™ monitors the load only for the 120 Volt GFCI outlets on the removable control panel. It does not measure load on the 240 Volt, 30 Amp outlet. The GenSmart™ indicator measures up to 4,800 watts of the generator’s rated wattage.
NOTE: If the 240 Volt receptacle is in use, the load indicated on the display will not accurately reflect the exact percentage of load being drawn from the generator.
Hour Meter
The digital hour meter operates whenever the engine is run­ning and keeps track of how many hours the unit has been used. Use this meter along with the accompanying engine manual to determine when and what type of service on the unit is needed.
Maintenance Warning System
At every 100 hours of use, the GenSmart™ monitoring system will display a message informing the operator to service the engine’s air filter, spark plug, and engine oil. To reset this message, push and hold the reset button located underneath the GenSmart™ display for 5 seconds.
Reading GenSmart™ Monitoring System At startup, the unit will display a message instructing the operator to read and understand the operator’s manual before using this product.
While the generator is running, the panel will display a power bar, load percentage, and total hours the unit has been operated.
At every 100 hours of use, a message will scroll across the display telling the operator to service the air filter, engine oil and spark plugs, and to push and hold the reset button for 5 seconds to reset the display.
NOTE: Be careful to only press and hold the reset button when you want the maintenance panel to be reset.
GENERATOR CONTROL PANEL
The stationary control panel has a twist-lock 240 Volt, 30 Amp outlet and circuit breakers.
OPERATING THE GENERATOR USING THE WALL MOUNTED REMOVABLE CONTROL PANEL
See Figure 17.
If the panel has been installed in a remote location:
Turn off the generator. Connect the generator to the removable control panel
using the twist-lock plug and the 12 Volt DC engine control connector on the provided control panel cord.
ONLY use a generator outdoors and far away from open
windows, doors, and vents. These openings can pull in generator exhaust.
Connect up to two additional 25 ft. control panel cords
to the provided 25 ft. control panel cord. The total length of all connected cords should not exceed 75 ft. or three (3) RDEC25 control panel cords.
Connect the control panel cord to the generator. Start the engine as described in Starting the Engine. Add devices to the generator and monitor the load of
each added device using the GenSmart™ display panel.
MOVING THE GENERATOR
See Figures 18 - 19.
Turn the switch to the OFF position. Disconnect any
equipment that is plugged into the generator.
Turn the fuel valve to the OFF position. Allow 30 minutes of “cool down” time before storing the
machine.
For security, insert the handle lock pin to secure the
handle before moving.
NOTE: To help keep the handle lock pin securely in the
hole, push the joined area of the lanyard toward the inside of the generator frame.
With your foot on the rear of the frame, tilt the machine
toward you until it balances on the wheels, then roll the machine to the desired location.
LIFTING THE GENERATOR
See Figure 20.
Fold the handle to the down position. Never lift or carry
this product using the handle.
NOTE: This tool is heavy and requires several people to lift. To avoid back injury, keep your knees bent and lift with your legs, not your back, and get help when needed.
ELECTRIC START
See Figure 21.
This generator model is provided with both electric start and recoil start capabilities. Avoid prolonged cranking, as it can damage the engine.
14 — English
OPERATION
The battery provided is a nominal 12 volt sealed recharge­able lead-acid battery and can be operated in any position without leakage. It complies with non-spillable battery regulations. Its convenient size offers a 30% reduction over conventional batteries.
NOTE: New generators are shipped with the battery con­nections disconnected. The positive and negative terminals must be connected to the battery before the Electric Start feature will work.
For initial battery connection, see Connecting Battery.
CAUTION:
On a level surface with the engine off, check the lubricant level before each use of the generator.
STARTING THE ENGINE
See Figure 22.
NOTE: If location of generator is not level, the unit may not start or may shut down during operation.
Unplug all loads from the generator. Turn the fuel valve to the ON position. Move the choke lever right to the START position.
NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever left to the RUN position.
Turn the engine switch key to “ON.”
Turn the engine switch key to “START” or pull the recoil
starting grip until the engine runs (a maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
NOTE: The battery is shipped in a low charge condition
and may require charging before the generator can be started using only the switch key. The generator can be started by pulling the recoil starter. Once the generator is started, the battery will charge as the unit runs.
Allow the engine to run for 30 seconds, then move the
choke lever left to the RUN position.
STOPPING THE ENGINE
See Figure 22.
To stop the engine under normal operating conditions:
Remove any load from the generator. Turn the switch key to “OFF”or press and hold the off
switch until the engine stops.
Turn the fuel valve to the OFF position. NOTE: If it is necessary to shut the engine off immediately,
either engine switch may be used if the removable control panel is connected to the unit. The off switch on the station­ary control panel can be used as the primary engine OFF
switch.
15 — English
MAINTENANCE
WARNING:
When servicing, use only identical RIDGID replacement parts. Use of any other parts may create a hazard or cause product damage.
Only the parts shown on the parts list are intended to be repaired or replaced by the customer. All other parts should be replaced at an authorized service center.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it is not exposed to dust, dirt, moisture, or corrosive vapors. Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water entering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
CHANGING FUSE
See Figure 23.
Remove screws from side cover. Lift up and remove side cover. Unscrew the fuse holder to reveal the fuse and spring. Insert new fuse into hole and retighten fuse holder se-
curely.
NOTE: If spring came out of fuse holder when it was
opened, it should also be replaced inside the fuse holder before securing.
Reinstall side cover. Reinstall screws and tighten securely.
CHECKING/CLEANING AIR FILTER
See Figure 24.
For proper performance and long life, keep air filter clean.
Remove screw. Lift air filter cover and set aside. Remove the filter element. If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
Apply a light coat of engine lubricant to the element, then
squeeze it out.
Replace the element in the air filter unit. Replace the air filter cover and latch to secure.
NOTE: Do not run the generator without the air filter. Rapid engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 25.
Remove the oil cap/dipstick. Place a container underneath the oil drainage bolt to
collect used lubricant as it drains.
Unscrew the oil drainage bolt and remove. Allow lubricant to drain completely. Reinstall the oil drainage bolt and tighten securely. Refill with lubricant following the instructions in the
Checking/Adding Lubricant section.
Reinstall the oil cap/dipstick. NOTE: Used lubricant should be disposed of at an ap-
proved disposal site. See your local oil retailer for more information.
SPARK PLUG MAINTENANCE
See Figure 26.
The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation. To check:
Remove the spark plug cap. Clean any dirt from around base of spark plug. Remove spark plug using wrench (not included). Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or chipped, spark plug should be replaced.
NOTE: If replacing, use the following recommended
spark plugs or equivalent: NGK BR6HS.
Measure plug gap. The correct gap is 0.028−0.031 in.
(0.7-0.8 mm). To widen gap, if necessary, carefully bend the ground (top) electrode. To lessen gap, gently tap ground electrode on a hard surface.
Seat spark plug in position; thread in by hand to prevent
cross-threading.
Tighten with wrench to compress washer. If spark plug
is new, use 1/2 turn to compress washer appropriate amount. If reusing old spark plug, use 1/8 to 1/4 turn for proper washer compression.
NOTE: An improperly tightened spark plug will become
very hot and could damage the engine.
16 — English
MAINTENANCE
CLEANING THE EXHAUST PORT AND MUFFLER
Depending on the type of fuel used, the type and amount of lubricant used, and/or your operating conditions, the exhaust port and muffler may become blocked with carbon deposits. If you notice a power loss with your gas-powered products, you may need to remove these deposits to restore perfor­mance. We highly recommend that only qualified service technicians perform this service.
SPARK ARRESTOR
See Figure 27.
Inspect the spark arrestor for breaks or holes. Replace
if necessary. To purchase a replacement spark arrestor contact RIDGID customer service at 1-866-539-1710.
Use a brush to remove carbon deposits from the spark
arrestor screen as needed.
DRAINING FUEL TANK/CARBURETOR
See Figures 28 - 29.
To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburetor before storing.
DRAINING THE FUEL TANK
Turn the engine switch key to “OFF”or press and hold the
off switch until the engine stops.
Turn the fuel valve to the OFF position. Remove the fuel line from the petcock by squeezing the
ends of the retaining clip and sliding the fuel line off.
Install one end of a drain line over the petcock, and place
the other end in a fuel container large enough to catch the fuel being drained from the tank.
Turn the fuel valve to the ON position. For better fuel drainage, please tilt the unit toward the
fuel petcock slightly (approximately 1 in.).
When the fuel has drained from the tank, close the fuel
valve and reinstall fuel line securely on petcock.
DRAINING THE CARBURETOR
Turn the engine switch key OFF or press and hold OFF
switch in the OFF position for three (3) seconds or until the engine stops.
Turn the fuel valve to the OFF position. Position a suitable container under the carburetor drain
screw to catch fuel; loosen the screw.
Allow fuel to drain completely into container. Retighten drain screw.
NOTE: Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel.
REPLACING FUEL FILTER
See Figure 30. Occasionally the fuel filter may become clogged and need
replacing. To purchase a replacement fuel filter contact Husky customer service at 1-866-539-1710.
NOTE: Fuel tank must be empty before replacing fuel filter. Run unit until tank is empty, if needed, or inspect filter prior to fill-up.
To replace:
Turn the fuel valve to the OFF position. Remove the fuel line from both sides of the filter by
squeezing the ends of the retaining clip with pliers.
Slide the fuel line off. Replace with new fuel filter. Reinstall fuel lines to new fuel filter. Turn the fuel valve to the ON position.
TRANSPORTING
Turn the engine switch OFF. Turn the fuel valve to the OFF position. Make sure engine and exhaust of unit is cool. Lower the handle. Keep unit level while transporting to prevent fuel spill-
age.
Do not drop or strike unit or place under heavy objects.
17 — English