Action required
Service manual revision
Retrofit information
No.:
K. Miura
RG678001
Firmware history for Eland 99 (Network Interface Board).
The software versions listed below can be used for the NIBs of the following models:
Stinger-C1/ Stinger-C1L/ Russian-C1/ Russian-P/ Adonis-C/ Adonis- P/ FresaW IN/ PomeloWIN/
Color Controller RC-200
PCL text filter support has been added.
The “RICOH” brand name has been deleted from several
functions and reports.
An Italian wording for “Config Reference” used in the Web status
monitor has been changed to “Riferim. Config”.
A Spanish wording for “Default Gateway Address” used in the
Web status monitor has been changed to “Direcci. Gateway”.
A type of Cisco router caused a problem in browsing the NIB in
AppleTalk network. The cause of this was in the Cisco router, but
the NIB firmware has been modified to fix this.
When a printer error occurs, the printer information cannot be
accessed using Macintosh printer utilities such as the Apple
Printer Utility.
The IPP (Internet Printing Protocol) function has been added.
On the web status monitor, the wording in German was incorrect.
“FreierSpeicher” has been corrected to “Freier Speicher”.
The Web status monitor displays a “No Tray/No Paper” error
when a tray is not closed completely. The message in this case
has been changed to “Other error”.
J
J
H
H
H
G
G
F
F
RICOHTechnical
Bulletin
PAGE: 2/2
Model:
Eland 99 (Network Interface Board)
Date:
Symptom Corrected
Disabling (Down) or enabling (Up) AppleTalk protocol from the
operation panel sometimes did not take effect after the change.
To avoid this, the firmware has been changed to save a new
setting to the NVRAM immediately after a change.
One banner page data of NetWare was split into two pages when
using NetWare 3.12 pserver mode.
In the NetWare remote printer mode, the NIB consumed a server
connection license. To avoid this, the firmware has been
modified to disconnect the NCP connection immediately after the
remote printer has connected to the server.
Software modified so that it can also be used for the Stinger-C.
On the web status monitor, the incorrect icon was used for
“Paper Empty”.
When the NIB was receiving five communications (five print jobs)
from PCs at the same time, any additional print job (6th print job)
disappeared.
21-Mar-00
F
E
E
D
C
C
No.:
RG678001
!"#$%T
Reissued: 12-Jun-00
echnicalBulletin
PAGE: 1/2
Model:
Eland 99 (Network Interface Board)
Date:
25-Apr-00
No.:
RTB Correction
The items with a line drawn through them have been deleted.
Subject:
From:
Classification:
ROM History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Firmware history for Eland 99 (Network Interface Board).
The software versions listed below can be used for the NIBs of the following models:
Stinger-C1/ Stinger-C1L/ Russian-C1/ Russian-P/ Adonis-C/ Adonis-P/
Color Controller RC-200
HTTP access has been improved when multiple protocols are
used at the same time (e.g. telnet, IPP and HTTP)
PCL text filter support has been added.
The “RICOH” brand name has been deleted from several
functions and reports.
An Italian wording for “Config Reference” used in the Web status
monitor has been changed to “Riferim. Config”.
A Spanish wording for “Default Gateway Address” used in the
Web status monitor has been changed to “Direcci. Gateway”.
A type of CISCO router caused a problem when browsing the NIB
on an AppleTalk network. The cause of this was in the CISCO
router, but the NIB firmware has been modified to fix this.
When a printer error occurs, the printer information cannot be
accessed using Macintosh printer utilities such as the Apple
Printer Utility.
IPP (Internet Printing Protocol) has been added.
On the web status monitor, the wording in German was incorrect.
“FreierSpeicher” has been corrected to “Freier Speicher”.
The Web status monitor displays “No Tray/No Paper” error when
a tray is not closed completely. The message in this case has
been changed to “Other error”.
K
J
J
H
H
H
G
G
F
F
!"#$%T
Reissued: 12-Jun-00
echnicalBulletin
PAGE: 2/2
Model:
Eland 99 (Network Interface Board)
Date:
25-Apr-00
Symptom Corrected
Disabling (Down) or enabling (Up) AppleTalk protocol from the
operation panel sometimes did not take effect after the change.
To avoid this, the firmware has been changed to save a new
setting to the NVRAM immediately after a change.
One banner page data of NetWare was split into two pages when
using NetWare 3.12 pserver mode.
In the NetWare remote printer mode, the NIB consumed a server
connection license. To avoid this, the firmware has been
modified to disconnect NCP connection immediately after the
remote printer has connected to the server.
Software modified so that it can also be used for the Stinger-C.
On the web status monitor, an incorrect icon was used for the
“Paper Empty”.
When the NIB was already receiving five communications (five
print jobs) from PCs at same time, the next print job (6th print
job) disappeared.
No.:
RG678002a
F
E
E
D
C
C
!"#$%T
echnicalBulletin
PAGE: 1/2
Model:
Subject:
From:
Eland 99 (Network Interface Board)
ROM History
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
13-Nov-00
Prepared by:
No.:
RG678003
H. Someya
Action required
Service manual revision
Retrofit information
Firmware history for Eland 99 (Network Interface Board).
The software versions listed below can be used for the NIBs of the following models:
Stinger-C1/ Stinger-C1L/ Russian-C1 (B307)/ Russian-P (G038)/ FresaWIN (G678-14)/
PomeloWIN (G678-13)/ Color Controller RC-200 (G528)
Bi-directional communication of "diprint" (using the 9100 port of
TCP/IP printing) is supported (required for the DAZEL system).
The "diprint direct [On/Off]" command using telnet has been
implemented for supporting bi-directional communication of
diprint (required for the DAZEL system). PortNavi and Multidirect
Print are not supported if bi-directional communication has been
selected.
The spelling of the command "retern" in the UNIX install shell has
been corrected to "return".
The DHCP of NetWare5 is supported.
The DHCP relay agent is supported. (This has been confirmed
only with the Windows NT 4.0 relay agent at this time.)
There may be some minor (character) display errors on the LCD
while the NIB firmware is being upgraded. The firmware has been
modified to prevent this.
HTTP access has been improved when multiple protocols are
used at the same time (e.g. telnet, IPP and HTTP)
PCL text filter support has been added.
L
L
L
L
L
L
K
J
!"#$%T
echnicalBulletin
PAGE: 2/2
Model:
Eland 99 (Network Interface Board)
Date:
Symptom Corrected
The “RICOH” brand name has been deleted from several
functions and reports.
An Italian wording for “Config Reference” used in the Web status
monitor has been changed to “Riferim. Config”.
A Spanish wording for “Default Gateway Address” used in the
Web status monitor has been changed to “Direcci. Gateway”.
A type of CISCO router caused a problem when browsing the
NIB in an AppleTalk network. The cause of this was in the
CISCO router, but the NIB firmware has been modified to fix this.
When a printer error occurs, the printer information cannot be
accessed using Macintosh printer utilities such as the Apple
Printer Utility.
IPP (Internet Printing Protocol) function has been added.
On the web status monitor, the wording in German was incorrect.
“FreierSpeicher” corrected to “Freier Speicher”.
The web status monitor displays a “No Tray/No Paper” error
when a tray is not closed completely. The message in this case
has been changed to “Other error”.
Disabling (Down) or enabling (Up) AppleTalk protocol from the
operation panel sometimes did not take effect after the change.
To avoid this, the firmware has been changed to save a new
setting to the NVRAM immediately after a change.
One banner page data of NetWare was split into two pages when
using NetWare 3.12 pserver mode.
In the NetWare remote printer mode, the NIB consumed a server
connection license. To avoid this, the firmware has been
modified to disconnect NCP connection immediately after the
remote printer has connected to the server.
Software modified so that it can also be used for the Stinger-C.
On the web status monitor, an improper icon was used for the
“Paper Empty”.
When the NIB was receiving five communications (five print jobs)
from PCs at same time, the additional print job (6th print job)
disappeared.
13-Nov-00
J
H
H
H
G
G
F
F
F
E
E
D
C
C
No.:
RG678003
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
General
ROM History (Eland 99: Network Interface Board)
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
13-Mar-01
Prepared by:
No.:
H. Someya
Action required
Service manual revision
Retrofit information
Firmware history for Eland 99 (Network Interface Board).
The software versions listed below can be used for the NIBs of the following models: