Rank: A : Replace with new parts immediately. B : Replace with new parts at time of repair.C : Replace with new parts at time of overhaul.
Interchangeability:
(1) When old and new parts are not mutually interchangeable, use additional parts or an assembly part as indicated in "Parts needed for
replacement by new part" to install the new part.
(2) The mark to the left of the slash indicates whether the old part can be used in the new machine, and the mark to the right indicates whether
the new part can be used in the old machine. x = Not interchangeable o = Interchangeable
1 → 1
1 → 1
1 → 1
1 → 1
427
1227
2327
2427
Page 9
MODIFICATION BULLETIN NO. 4 PAGE 2 OF 4
ISSUED ON: August 31, ’95
Draw
No.
Incorrect
Parts No.
A0491704PCB Guide Bracket - Front
A0491705
A0491701
A0491703
A0491702PCB Guide Bracket - Rear
10050907Rail - 50 x 6040
10050785PCB Guide Rail
Correct
Parts No.
A1051702PCB Guide Bracket - Front
A1051701PCB Guide Bracket - Rear
DescriptionRank
PCB Guide Bracket - Front
Right
PCB Guide Bracket - Rear
Left
PCB Guide Bracket - Rear
Right
Q’ty Used
Old → New
1 → 0
1 → 0
0 → 1
1 → 0
1 → 0
1 → 0
0 → 1
2 → 0
n → n-2
Inter-
change-
ability
Part needed for replacement by new part
Part No.DescriptionNo.Page
Parts
Catalog
129
229
* 25
429
529
629
* 26
11029
11529
10050958PCB Guide Rail
03540060BScrew - M4 x 6
03530060BScrew - M3 x 6
A1051292Bracket - Rear Left Cover
A1095731IPU Cover Seal
A1095720Seal - 9.5 x 9.5 x 125
DescriptionRank
Philips Truss Head Screw
M4 x 6
Q’ty Used
Old→New
1 → 1
n → n+2
0 → 1
0 → 4
0 → 2
1 → 1
Date of
Modification
Inter-
change-
ability
X/O-17, -25, -271713
X/O-17, -25, -276921
Parts needed for replacement by new part
Part No.DescriptionNo.Page
-17, -25, -2710113
-17, -25, -274813
-25, -274913
-25, -275013
Serial
Number
Parts
Catalog
A092 1521A1051521
A049 1522A1051522Right Lower Bracket
A0921522A1051523Operation Panel Bracket
Rank: A : Replace with new parts immediately. B : Replace with new parts at time of repair.C : Replace with new parts at time of overhaul.
Interchangeability:
(1) When old and new parts are not mutually interchangeable, use additional parts or an assembly part as indicated in "Parts needed for
replacement by new part" to install the new part.
(2) The mark to the left of the slash indicates whether the old part can be used in the new machine, and the mark to the right indicates whether
the new part can be used in the old machine. x = Not interchangeable o = Interchangeable
Left Lower Bracket Operation Panel
2 → 2
1 → 1
3 → 3
X/O-17, -25, -276721
X/O-17, -25, -276821
X/O-17, -25, -276421
Page 13
MODIFICATION BULLETIN NO. 5 PAGE 2 OF 6
ISSUED ON: November 30, ’95
Draw
No.
Old Parts
No.
03540060B
A1055191A1055192IPU Relay Harness
A1055666A1055670Laser Unit Data Harness
A1055664A1055665Laser Unit Main Harness
To comply with the CE mark standards, th e following modifications have been made.
1. To improve grounding, two screws have been
added to secure the rear lef t cover. Also, the
IPU cover seal and seal 9.5x9 .5x125 have
been added.
2. To improve groundin g, six screws have
been added to secure the operation panel
lower cover to the main frame.
To improve grounding, three screws ha ve
been added to attach the operation pane l
assembly to its brackets.
IPU Cover Seal
Seal 9.5x9.5x125
Bracket Rear Left Cover
Operation Panel Bracket
Right Lower
Bracket
newly
added
3 screws added
OLD
Page 15
ISSUED ON: November 30, ’95ISSUED ON: November 30, ’95
MODIFICATION BULLETIN NO. 5 PAGE 4 OF 6
NEW
DETAILS OF MODIFICATION
3. To reduce electrical noise, ferrite cores
have been added to the IPU relay
harness, the laser unit main harn ess,
and the laser unit data harness.
A ferrite core (P/N 16070881) has
been added also to th e LED harness
inside the editor board.
OLD
Laser Unit Harness
OLD
OLD
NEW
IPU Relay Harness
NEW
Laser Unit Main Harness
Page 16
ISSUED ON: November 30, ’95
MODIFICATION BULLETIN NO. 5 PAGE 5 OF 6
Philips Screw with
Flat Washer M3x4
4. To reduce th e ele ctrica l noise, spacers made
of copper plate have been added around the
exposure glass.
The front scale spacer an d th e right scale
spacer are copper plates, and a similar
copper plate is attached to the rear edge of
the exposure glass.