T
Reissued: 30-Apr- 99
echnical
B
ulletin
PAGE: 1/1
Model:
F401/411/421/C-Bird
Date:
15-Apr-99
No.:
RA175012a
RTB Correction
The items (cut-in serial number) in bold italics have been corrected.
Subject:
From:
Classification:
DJF Software Modification History
Technical Service Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
DJF modifications and history are as follows.
Main ROM(A6105820) modification history
Suffix Description Cut-in Serial Number
C This ROM was used from the first production run. A610-15: A16060001
D To prevent original ja ms:
In the limitless mode, if a new original is fed while the
paper trays are being switched, a j am will occur.
E This version is the same as that of “C”.
Notes
A software change will not prevent original jams in the
limitless mode if a new original is fed while the paper
trays are being switched.
Since the occurrence rate of this problem is extremely
low, this is being treated as a product limitation.
F Standardization with the Penguin series A610-15: 6A18030001
G To prevent the fo llowing problems when the 2 in 1 mode
is used:
z
The machine stops (but t he print key remains red) after
the job if the number of origi nals and the number
input on the main unit differ.
z
After an odd nu mber o f originals is used, the im age in
the next copy job is elongated or a paper jam
occurs.
H To prevent original non-feed out in European version
main frame ma ch ine s :
Due to the difference in the feed-in and feed-out timing
for the B6Y size paper, three or igi nals will be set on the
exposure glass at the same time as opposed to two.
Prepared by:
A610-17: A7146060001
A610-22: AB86060001
A610-26: J90660001
Not implemented
A610-15: 6A16120001
A610-17: A7146110001
A610-22: AB87010001
A610-26: 3J90170001
A610-17: A714803000
A610-22: AB88030001
A610-26: 3J90680001
A610-15: 6A18060001
A610-17: A7148060001
A610-22: AB88060001
A610-26: 3J90680001
A610-15: 6A18100001
A610-17: A7148100001
A610-22: AB88100001
A610-26: 3J91080001
F. Noguchi
Action required
Service manual revision
Retrofit information