Technical Bulletin No. RTB-007
SUBJECT: To reset original misfeeds in a single step DATE: 30 Sep.’91
PAGE: 1 of 1
PREPARED BY: S. Orita
CHECKED BY:
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
Due to software change for the Japanese version, the part number of the ROM on the DF
main board was changed from A4655160 to A4655180.(See MB No.18 for A465 issued
on March 31,1990.)
However, we found the following problem when P/N A4655180 is installed on the DF main
board.
When an original misfeeds, it is necessary to open and close the DF cover two times to
reset the original misfeed. (The original misfeed cannot be removed by opening and
closing the DF cover only once.)
NOTE: This problem occurs only when the P/N A4655180 is installed on the DF main
and the DF is installed on the M210.
Revision of service manual
Information only
Other
TO: Copier Technical Support Section
MODEL:
M210 ARDF
(A318 and A465)
To prevent this problem, the ROM on the DF main board has been changed.
The part number for the new ROM is A4655185.
Please refer to the MB No.3 for A318.
Technical Bulletin No. RTB-002
SUBJECT: APS Priority with ADF (Pigeon A only) DATE: Aug. 15, ’93
PAGE: 1 of 3
PREPARED BY: S. Orita
CHECKED BY:
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
[Phenomenon] The copier will not select APS automatically with ADF when the
original is set on the ADF, although the data of SP21 (APS priority for
ADF) is set to "0" (0: APS, 1: Manual).
Note: This problem occurs only on A110 copiers (Pigeon A)
[Cause] Software problem for SP21 and SP72. (Refer to the table below.)
[Solution] To solve this problem, the ROM has been changed from P/N
A1115107 to P/N A111 5107A.
The functions of SP21 and SP72 for each ROM are as follows:
SP Mode No. P/N A1115 107 P/N A11151 07A
Revision of service manual
Information only
Other
with ADF. It does not occur on A111 copiers (Pigeon B).
FROM: Copier Technical Support Section
MODEL:
Pigeon A ( A110)
20 APS Priority
(Copier)
21 APS Priority
(ADF)
72 For A110 copiers, the default
The default is "0". (0: APS, 1:
Manual)
When the main switch is
turned on, the data will
automatically change to "1"
although the data is set to "0".
When the main switch is
turned on, the data will
automatically change to "1"
although the data is set to "0".
(0: APS, 1: Manual)
is "1". (0: Normal, 1: APS
disabled)
The default is "0" and the
factory setting is "1".
The data does not change
although the main switch is
turned on.
The data does not change
although the main switch is
turned on.
Same as P/N A1115107.