RA265001
SYMPTOM
In cases where the country code has been changed to France (00), the following error is
displayed as soon as the quick dial key is selected:
"This destination is not available. Please check FAX number".
CAUSE
The communication switch 06 bit 4 mode is a carryover from the previous model and is not
used in the Russian-C1. However, the software activates the mode by changing the value
from 0 to 1 when the country code is changed to 00. For modes that are carried over but
not meant to be used, the software will normally not do this.
SOLUTION
After changing the country code to France (00) at installation, communication switch 06 bit
04 should be disabled by changing the value from 1 to 0.
As a permanent solution, a modified version (ver. 13.04) of the software has been
released.
Page 2
T
echnical
B
ulletin
PAGE: 1/4
Model:
Subject:
From:
Russian-C1
Service Manual Correciton
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
15-Feb-00
Prepared by:
No.:
RA265002
S. Tomoe
Action required
Service manual revision
Retrofit information
Please correct your service manuals as follows:
1. The optional 48 MB memory is not required when installing the optional finisher.
1.2.2 INSTALABLE OPTION TABLE (P 1-7)
- Incorrect -
No.OptionRussian-
C1A/C1B
111000-sheet Finisher (Option)
∆
Requires No. 10, 12 and either no.3 or 4
Note
- Correct -
No.OptionRussian-
C1A/C1B
111000-sheet Finisher (Option)
∆
Requires No. 10 and either no.3 or 4
Note
3.12. 1,000-SHEET FINISHER INSTALLATION (P 3-35)
Delete Note no.2: “If this finisher will be installed on the A265 or A267 copier, …”
2. SP 5-401-2 and –3 are only used in machines for the Japanese market.
Please correct the SP mode table as follows:
Mode No.
Class
1 and 2
5-4012User Code Mode
Class
3
(Fax)
3User Code Mode
(Fax)
This SP is for Japan only, Do not
change the value.
This SP is for Japan only, Do not
change the value.
FunctionSetting
0: No
1: Yes
0: No
1: Yes
Page 3
T
echnical
B
ulletin
PAGE: 2/4
Model:
3. The call-outs and installation steps for the optional tray heater should be corrected as
Russian-C1
follows (P 3-46).
[C]
Date:
[A]
15-Feb-00
[B]
No.:
RA265002
[D]
[E]
[D]
A2651505.WMF
5. Slide out the two paper trays from the optional paper tray unit.
6. Pass the connector [A] through the opening [B].
7. Install the tray heater assembly [C] (1 screw).
8. Clamp the cables [D], as shown.
A2651503.WMF
9. Join the connectors [E].
10. Reinstall the cable guide.
Page 4
T
echnical
B
ulletin
PAGE: 3/4
Model:
Russian-C1
Date:
15-Feb-00
4. The settings of the following SP modes should be corrected.
SP1-908-8, SP1-909-8, SP 1- 910- 8 , and SP1- 91 1- 8
Incorrectcorrect
0: None (Not used)
1: HLT/A5
2: A4
3: LT
4: DLT
5: A3
Note:
The “T” after A4 and LT refer to the lengthwise feeding direction.
The “T” after A4 and LT refer to the lengthwise feeding direction.
0: None (Not used)
1: HLT/A5
2: A4T
3: LG, LTT
4: DLT, LT
5: A3, A4
No.:
RA265002
5. Add the following SC code:
7.1.2 SC CODE DESCRIPTIONS
SC981: NVRAM Error
Definition: [B]
The NVRAM is defective
Possible Causes:
NVRAM defective
BICU defective
Page 5
T
echnical
B
ulletin
PAGE: 4/4
Model:
6. The PM table for the 1000-sheet finisher should be corrected (P 5-2).
7. The following part number should be corrected (P 4-83).
8. The following HDD error code for the printer should be corrected:
Russian-C1
Delete Punch Waste Hopper.
EM120K240K360KNote
1,000-SHEET FINISHER
Punch Waste HopperIIIIEmpty the hopper.
Wrong Parts
Number
A2679001A2679099NVRAM – Minus Counter1
6.2 ERROR CODES (Printer controller, P-6-2)
Correct Parts
Number
Date:
DescriptionQ’ty
15-Feb-00
No.:
RA265002
- Incorrect -
CodeDescriptionRequired Action
3002A damaged cluster was found on the
HDD.
- Correct -
CodeDescriptionRequired Action
3003 or
3004
A damaged cluster was found on the
HDD.
The damaged cluster is automatically marked
as “bad”.
If this error is frequent, format the HDD.
The damaged cluster is automatically marked
as “bad”.
If this error is frequent, format the HDD.
Page 6
RICOHTechnical
Bulletin
PAGE: 1/2
Model:
Subject:
From:
Russian-C1
ROM History
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
29-Feb-00
Prepared by:
Action required
Service manual revision
Retrofit information
This is to inform you of the BICU firmware history for the Russian-C1.
- USA Model -
A2675532VersionC. SUMProduction
B1.57C4BA1st Mass Prod.
C1.64A2BFOctober Prod. ‘99
- European Model -
A2675533VersionC. SUMProduction
No.:
S. Tomoe
RA265003
B1.5786E81st Mass Prod.
C1.64837FOctober Prod. ‘99
- Asia/Taiwan/China Models -
A2675534VersionC. SUMProduction
A1.64A2BF1st Mass Prod.
B1.710FE8March Prod. ‘00
Page 7
RICOHTechnical
Bulletin
PAGE: 2/2
Model:
The machine goes into Energy Saver Mode when the operator presses the
Energy Saver Mode key while a print job is in progress. However, when the
operator brings the machine out of the mode and returns to System Settings or
Copy Features (both inside user tools), a message is displayed asking the
operator to wait and the machine returns to the main copy screen. At this time,
the LED for the user tools key is lit, and all indicators except the LCD report that
the machine is st ill in User Tools.
If the operator enters System Settings or Copy Features (both inside user tools)
from Fax, Printer or Scanner mode while a duplex or staple copy job is in
progress, the “Copy in progress” screen is displayed.
The message is still displayed even if the operator presses the User Tools Key
to return to the main copy screen after the copy job finishes.
If a jam occurs while printing out a counter report, the jam indication is
displayed but soon disappears. The machine then returns to the counter display
screen. In addition, if the paper end condition occurs while the paper is being
fed, the machine returns to the counter display screen without properly
displaying “Set A4 (81/2 X 11) paper in tray”.
Russian-C1
Symptom CorrectedUSAEUAsia
Date:
29-Feb-00
No.:
RA265003
BB---
BB---
BB---
On machines with an optional LCT installed, SC507 can occur when the main
power switch is turned on under the following conditions: 1. The LCT end fence
is not in the HP
lower HP sensor.
However, these occurrence conditions are very rare.
“1/2” appears in the Key Operator Tools display (inside user tools – system
settings).
After the operator exits either of the following screens with the User Tools key
and starts a copy job, the first sheet is printed out as the counter list.
·
System Settings – Key Operator Tools – Counter List Printing
·
Copy Features– Key Operator Tools – Counter List Printing
Corrects Taiwanese translation error.------B
and
2. The bottom plate for the right tray is not detected by the
BB---
BB---
BB
Page 8
T
echnical
B
ulletin
PAGE: 1/2
Model:
Subject:
From:
Classification:
Printer firmware history for the Russian-C1
- For Other Models -
- Lanier -
Russian-C1
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
B3065283VersionC. SUMProduction
Date:
Prepared by:
Part information
Electrical
Transmit/receive
08-Mar-00
No.:
RA265004
S. Tomoe
Action required
Service manual revision
Retrofit information
A1.2.0FCB91st Mass Prod.
Page 9
T
echnical
B
ulletin
PAGE: 2/2
Model:
Firmware modified so that it can be used with printer controllers for China and Taiwan.
Firmware modified so that it will be compatible with the new HDD to be used in the
printer controller.
Note:
If a Postscript Driver job is canceled midway through, the image data for the next job is
not printed out correctly.
"Waiting..." is displayed when an error occurs, but the machine does not return to
normal operating mode (ready status). The next job is not printed out.
When two separate jobs of text data less than 256 bytes are sent from the network, the
two jobs are printed out simultaneously on the same page.
It is possible to print out the HDD Directory List when there is no HDD or PS option
installed.
Corrects Taiwanese translation error.B---
If data recovery (Raster image production) takes longer than usual when using
Formfeed, the Alarm LED remains lit until printing begins. To correct this, the LED can
now be turned off by pressing the ENTER key.
Russian-C1
Symptom Corrected
The new HDD is identical in function to the previous one.
Date:
08-Mar-00
No.:
Other
models
B--B---
B--B--B--B---
B---
RA265004
Lanier
Page 10
T
echnical
B
ulletin
PAGE: 1/1
Model:
Subject:
From:
Classification:
Russian-C1
Scanner Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Scanner firmware history for the Russian-C1
A8775810VersionC. SUMProduction
E3.0.160321st Mass Prod.
F4.0.02E79February Prod. ‘00
G4.0.35736March Prod. ‘00
Date:
Prepared by:
Part information
Electrical
Transmit/receive
10-Mar-00
No.:
RA265005
S. Tomoe
Action required
Service manual revision
Retrofit information
Symptom CorrectedSuffix
The firmware was modified so that it can be used with the scanner controller for Adonis-C1.
The machine sometimes scans part of the exposure glass scale and edge of the original. To
prevent this, a new scanner SP mode has been added (SP017, Scanner Margin Adjustment).
Note:
After installing the firmware, Scanner SP006 must be performed.
The machine stalls when the memory full condition is reached.F
When Scanner Auto Clear is enabled:
If an ADF jam occurs during a scanning job initiated before the Scanner Auto Clear timer expires,
the scanner settings are reset to the defaults.
F
F
G
Page 11
RICOH Technical
Bulletin
PAGE: 1/3
Model:
Subject:
Option)
From:
Russian-C1
Scale and edge of original is scanned (Scanner
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Date:
Prepared by:
Part information
Electrical
Transmit/receive
10-Mar-00
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265006
SYMPTOM
When using the scanner function, the machine sometimes scans part of the exposure
glass scale and the edge of the original. A black line appears on the scanned image.
CAUSE
Scanning starts from the upper-le ft hand corner o f the exposur e glass. Ther e for e, w hen
the original is curled or not lined up flush against this corner (platen mode) or when DF
feed is late (ADF mode), the machine scans part of the exposure glass scale and the edge
of the original.
SOLUTION
A new scanner SP mode has been added (SP017, “Trimming”) so that the scanning
margin can be adjusted. This SP mode was made available with the release of scanner
controller firmware version 4.0.0. After installing
to perform SP006 to reset the UP and SP settings related to the scanner.
The details of this SP mode are as follows:
Scanner SP017
NoFunctionSettings
017Trimming
Adjusts the scanning margins for both the main and
sub scan directions.
The larger the value, the wider the margin.
Note:
This problem occurs only when the machine is set to scan the entire original, not when
scanning a selected area within the original. Therefore, this SP mode does not apply to
cases where the Preview function is used.
this
firmware version, please make sure
0 ~ 5
1 mm / step
0
Page 12
RICOH Technical
Bulletin
PAGE: 2/3
Model:
Examples:
1. When the machine scans an A4 sized original in Platen Mode and the value of SP017 is
5 (illustration 1 below):
Since the scanning start position is at “A”, margins will placed at 5 mm from the left and
right edges (main scan) as well as from the leading and trailing edges (sub -scan).
Any image within 5 mm of the four edges will be erased.
2. When scanning a selec ted area with the P r eview function in Platen Mode and the value
of SP017 is 5 (illustration 1):
Since scanning starts from point “B”, the 5 mm margin is not applied to the selected
area, and nothing in this area is erased along either scan direction.
3. When the machine scans an A4 sized original in ADF mode and t he value of SP017 is 5
(illustration 2):
Russian-C1
Date:
10-Mar-00
No.:
RA265006
In ADF mode, the original is centered along the main scan direction. Although the subscan direction margins are applied to the original (as in example 1), the main scan
margins will not appear (left/right edges). This is because the machine applies the 5 mm
main scan margin using reference point “C” (where scanning begins), and so the
centered A4 original is too narrow for the main scan margin to appear.
Page 13
RICOH Technical
g
g
Bulletin
PAGE: 3/3
Model:
Russian-C1
A
5 mm
B
Date:
Scannin
direction
10-Mar-00
5 mm
Original
5 mm
No.:
RA265006
5 mm
ADF
lass
Scan Line
1. Platen mode
C
A4 size original
5 mm
5 mm
5 mm
5 mm
2. ADF mode
Page 14
RICOH Technical
Reissued: 21-Mar-00
Bulletin
PAGE: 1/2
Model:
Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
BICU firmware history for the Russian-C1.
USA Model
ROM History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
A2675532VersionC. SUMProduction
B1.57C4BA1st Mass Prod.
C1.64A2BFOctober Prod. ‘99
D1.74C99DMarch Prod. ‘00
Part information
Electrical
Transmit/receive
29-Feb-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265003a
European Model
A2675533VersionC. SUMProduction
B1.5786E81st Mass Prod.
C1.64837FOctober Prod. ‘99
D1.740C26March Prod. ‘00
Asia/Taiwan Models
A2675534VersionC. SUMProduction
A1.64A2BF1st Mass Prod.
B1.710FE8
C1.740C26March Prod. ‘00
China Model
A2675536VersionC. SUMProduction
A1.747FBA1st Mass Prod.
April Prod. ‘00
Page 15
RICOH Technical
Reissued: 21-Mar-00
Bulletin
PAGE: 2/2
Model:
Chinese translation error.---------A
In Printer mode, dirty background may appear near the leading edge
of the first page printed out following a paper jam recovery.
When exiting to the 1-bin tray, a paper jam may occur caused by the
bouncing of the exit sensor actuator.
Russian-C1
Symptoms Corrected (See RTB 3 for older symptoms)USAEUAsiaCHN
Date:
29-Feb-00
DDCA
DDCA
No.:
RA265003a
Page 16
RICOH Technical
Reissued: 21-Mar-00
Bulletin
PAGE: 1/2
Model:
Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
Printer firmware history for the Russian-C1
Other Models
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
C1.3.4C923March Prod. ‘00
Part information
Electrical
Transmit/receive
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004a
Lanier Model
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
Page 17
RICOH Technical
Reissued: 21-Mar-00
Bulletin
PAGE: 2/2
Model:
Electrical sort mode (collation) will be disabled when special paper mode is
selected for tray 2.
If the bridge unit cover is opened during printing in electrical sort mode (second
set onward), the machine cannot recover from the resulting jam condition.
Even when the PJLK command “<Esc>&11H” is released instructing the
machine to feed the paper from tray 2, the paper is not fed from the tray.
Version 1.3.4 is being released in response to a special request from the Italian
Postal Service.
In addition to the cumulative total counter value (copier/fax/printer), the total
counter values for each function can be sent to PCs connected to the PAS
Server.
With Overlay printing, the text outside the fixed overlay pattern is printed out as
PCL commands (specifically, the ESC sequence).
Russian-C1
Symptom Corrected (see RTB 4 for earlier symptoms)
Date:
08-Mar-00
No.:
RA265004a
Other
models
CB
CB
CB
CB
CB
Lanier
Page 18
!"#$%T
echnicalBulletin
PAGE: 1/2
Model:
Subject:
From:
Russian-C (Printer Option)
Hard Disk Compatibility
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
29-Mar-00
Prepared by:
No.:
RA265007
K. Misugi
Action required
Service manual revision
Retrofit information
This RTB informs possible compatibility problems with the Printer Hard Disk Type 185
(model code: G690-06).
This hard disk unit can be used in the following models.
• Stinger-C (Stinger-C1L) printer option
• Russian-C printer option
• Russian-P
Background
The production of the current 1.6 GB hard disk unit will be discontinued in March ’00, and
the new 6.0 GB hard disk will be used from April.
When the new 6.0 GB hard disk unit is installed in the machine with a previous version of
the controller software, an error may occur.
Please note that the controller firmware has been modified from January ’00 production
(for all above models) so the machines are compatible with both the old 1.6 GB and the
new 6.0 GB hard disk unit.
Compatibility Table
Previous controller firmware
Version 1.2.9 or later
(modified from January ‘00
production)
Old 1.6 GB HDD
(G690-06)
CompatibleError may occur
CompatibleCompatible
New 6.0 GB HDD
(G690-07)
Symptom
The machine may not be able to detect the HDD at the power-on self-diagnostic test.
For Stinger-C/Russian-P with printer option: SC2001 3003 (HDD error) is displayed
For Russian-P: Error 5 (HDD error) is displayed
Solution
Turn the main switch off and on.
If the problem persists, try turning off and on again.
Page 19
!"#$%T
echnicalBulletin
PAGE: 2/2
Model:
Once the machine detects the HDD properly (no error message is displayed), there are no
problems with the performance of the machine.
For a permanent solution, please upgrade the controller software with version 1.2.9 or
later.
Russian-C (Printer Option)
Date:
29-Mar-00
No.:
RA265007
Page 20
!"#$%T
echnicalBulletin
PAGE: 1/1
Model:
Subject:
From:
Russian-C1 (Printer Option)
NIB NVRAM Backup and Restore
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
20-Apr-00
Prepared by:
No.:
RA265008
S. Tomoe
Action required
Service manual revision
Retrofit information
This RTB informs of possible problems when using the NIB NVRAM backup and restore
function.
Symptom
The machine may not start up after the NIB NVRAM backup procedure (Service Tool: NIB
read/write). This problem may occur after the NIB NVRAM data is backed up to the
controller (data copy direction: “NIB -> CTL”).
This is because the NVRAM is not big enough to store all the NIB data.
Note: The NIB NVRAM backup and restore procedure is required only when replacing the
NIB.
Solution
Do not use the NIB NVRAM backup (and restore) procedure.
If the machine does not start up after performing this function, you must download the
controller firmware using the error recovery firmware update procedure.
(This procedure will force the controller to boot from the IC card. Please refer to section
4.5.2 of the service manual for the detailed procedure.)
The controller firmware will be modified so this function will no longer be valid. It will not be
shown in the Service Tools.
The firmware is modified from the April ’00 production (version 1.3.6).
Currently there is no way to enable this function because the current NVRAM on the
controller board is not big enough to store all the NIB NVRAM data.
After replacing a NIB, please input the data manually.
Printer Controller Service Manual (B306) Correction
The printer controller manual should be corrected as follows.
1. Delete the column for the Service Tools – L (NIB Read/Write) on page 4-2.
2. Delete section 4.4.3 NIB NVRAM BACKUP AND RESTORE on page 4-7.
Page 21
!"#$%T
echnicalBulletin
PAGE: 1/4
Model:
Russian-C (Fax Option)
Date:
28-Apr-00
No.:
Number Correction, RTB Correction
The bulletin number has been corrected. (RA895001 → RA265009)
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
ROM History (Russian-C Fax Option)
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Firmware history for the Russian-C Fax Option
USA Model
File No.
A2685582(A268Uxxx)VersionC.SUMProduction
B00210.0348D41st Mass Prod.
C00313.03AE2EDecember Prod. ‘99
European Model
Prepared by:
Action required
Service manual revision
Retrofit information
M.Mano
RA265009
File No.
A2685584(A268Exxx)VersionC.SUMProduction
C10310.0325121st Mass Prod.
D10412.0135B2November Prod. ‘99
Symptom Corrected (for older corrections, see previous
RTBs)
When sending an original wider than the maximum paper
width of the receiving machine (Auto-Reduction OFF / JBIG
compression), the machine cuts the image to the smaller
size but sends the left most area of the image instead of the
central area.
The symptom occurs only when the following software is
used:
European model:A2685584C (ver. 16.01)
European 2
European 3
Asian model:A2685587D (ver. 17.02)
Even though the following bit switch settings should disable
the File Retention function, the machine retains files for 24
hours:
User Parameter switch 24 (swusr_18):
(bit 1, bit 0) = (1, 0)
When bit 4 of Communication switch 07 is 1 (Fallback from
G4 to G3 when G4 communication fails on the ISDN Bchannel is enabled) and a G4 communication error occurs
on the ISDN B-channel (ADF mode), the machine falls back
to G3 and resumes transmission from the second page. This
is because the first page has already fed out from the ADF.
The PTT approval for Hungary has been passed.
The following country code will be added for Hungary:
22H (34)
The following Chinese characters have been corrected for
the KANTAI display language:
nd
language: A2685585C (ver. 16.01)
rd
language:A2685586C (ver. 16.01)
No.:
RA265009
USAEUEU2EU3Asia/
TWN
-
-
-
-
- ---
HDD D
HDD D
HDD C
HDD
-
C
>
>
When using the Create Margin Transmission function and
the rear side image needs to be rotated 180 degrees, the
margin for the rear side is placed on the right (instead of the
left).
A ghost image may appear on the left of the page in JBIG
direct transmission mode during dual operation.
(The page width data is occasionally not received before
making the page.)
-GCC
-GCC
C
C
Page 24
!"#$%T
echnicalBulletin
PAGE: 4/4
Model:
A2685582A895-01
A2685584A895-02
A2685585A895-02
A2685586A895-02
Russian-C (Fax Option)
C
D
E
F
G
HTBA
A
B
C
DTBA
A
B
C
DTBA
H3491200001 ∼
H3491003837∼
H3491202306 ∼
H3491202306 ∼
H3400200728
H3491202306 ∼
H3491202306 ∼
H3400200728
H3491202306 ∼
H3491202306 ∼
H3400200728
∼∼∼∼
∼∼∼∼
∼∼∼∼
Date:
28-Apr-00
No.:
RA265009
A2685587A895-03
A
B
C
DTBA
H3491202496 ∼
H3400201122 ∼
H3400404851 ∼
Page 25
!"#$%T
echnicalBulletin
PAGE: 1/1
Model:
Subject:
From:
Classification:
Firmware history for the Russian-C SG3-V34 option.
Russian-C (Fax Option)
V34 Modem ROM History (Russian-C SG3 Option)
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
A8955590VersionC.SUMProduction
“ ”03316D4C1st Mass Prod.
A0334885EFebruary Prod. ‘00
Part information
Electrical
Transmit/receive
Date:
28-Apr-00
Prepared by:
Symptom Corrected
A communication error occurs when the modem data is erased by a
loader malfunction.
The malfunction is caused by a buildup of static electricity.
Note: * Panasonic modem only.
* The loader is a function normally contained in the
modem software that allows it to be overwritten to a newer
version.
No.:
RA265010
M.Mano
Action required
Service manual revision
Retrofit information
Version
A
To prevent this error, the manufacturer has removed the loader function
from ROM version 0334.
This function was also removed because the manufacturer does not
intend to release any versions after 0334, as it has judged that the need
will not arise in the field.
As a result, customers who use an SG3 option with ver.0334 will need a
technician to install a new SG3 board to update to the next version (if
released).
Page 26
!"#$%T
echnicalBulletin
PAGE: 1/3
Model:
Subject:
From:
Russian-C (Fax Option)
CTR21 Requirements
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
08-May-00
Prepared by:
No.:
RA265011
M.Mano
Action required
Service manual revision
Retrofit information
For European models, the following parameters should not be changed from their default
settings in the field.
REASON: The default values for these parameters have been approved by CTR21 and/or
EG201121. Therefore, a change in any one of these values would constitute a
violation of these requirements.
Bit Switches
ParametersDescriptions
Communication switch 10Memory transmission:
Maximum number of dialing attempts to the same destination.
Communication switch 12Memory transmission:
Interval between dialing attempts to the same destination.
Page 27
!"#$%T
echnicalBulletin
PAGE: 2/3
Model:
RAM Addresses for Standard G3
RAM Address: 680404PSTN dial tone frequency upper limit (high byte)
RAM Address: 680405PSTN dial tone frequency upper limit (low byte)
RAM Address: 680406PSTN dial tone frequency lower limit (high byte)
RAM Address: 680407PSTN dial tone frequency lower limit (low byte)
RAM Address: 680408PSTN dial tone detection time
RAM Address: 680409PSTN dial tone reset time (LOW)
RAM Address: 68040APSTN dial tone reset time (HIGH)
RAM Address: 68040BPSTN dial tone continuous tone time
RAM Address: 68040CPSTN dial tone permissible drop time
RAM Address: 68040DPSTN wait interval (LOW)
RAM Address: 68040EPSTN wait interval (HIGH)
RAM Address: 68044ATime between opening or closing the DO relay and opening
RAM Address: 68044BBreak time for pulse dialing
RAM Address: 68044CMake time for pulse dialing
RAM Address: 68044DTime between final OHDI relay closure and DO relay opening
RAM Address: 68044EMinimum pause between dialed digits (pulse dial mode)
RAM Address: 68044FTime waited when a pause is entered at the operation panel
RAM Address: 680450DTMF tone on time
RAM Address: 680451DTMF tone off time
RAM Address: 680452Tone attenuation level of DTMF signals while dialing
RAM Address: 680453Tone attenuation value difference between high frequency
RAM Address: 680472Acceptable ringing signal frequency: range1, upper limit
RAM Address: 680473Acceptable ringing signal frequency: range1, lower limit
RAM Address: 680474Acceptable ringing signal frequency: range2, upper limit
RAM Address: 680475Acceptable ringing signal frequency: range2, lower limit
RAM Address: 680476Number of rings until a call is detected
RAM Address: 680477Minimum required length of the first ring
RAM Address: 680478Minimum required length of the second and subsequent rings
RAM Address: 680479Ringing signal detection reset time (LOW)
RAM Address: 68047ARinging signal detection reset time (HIGH)
RAM Address: 6804B4PSTN: Tx level from the modem
RAM Address: 6804DAT.30 T1 timer
Russian-C (Fax Option)
ParametersDescriptions
the OHDI relay
or closing
tone and low frequency tone in DTMF signals
Date:
08-May-00
No.:
RA265011
Page 28
!"#$%T
echnicalBulletin
PAGE: 3/3
Model:
RAM Addresses for Optional G3
RAM Address: 680504PSTN dial tone frequency upper limit (high byte)
RAM Address: 680505PSTN dial tone frequency upper limit (low byte)
RAM Address: 680506PSTN dial tone frequency lower limit (high byte)
RAM Address: 680507PSTN dial tone frequency lower limit (low byte)
RAM Address: 680508PSTN dial tone detection time
RAM Address: 680509PSTN dial tone reset time (LOW)
RAM Address: 68050APSTN dial tone reset time (HIGH)
RAM Address: 68050BPSTN dial tone continuous tone time
RAM Address: 68050CPSTN dial tone permissible drop time
RAM Address: 68050DPSTN wait interval (LOW)
RAM Address: 68050EPSTN wait interval (HIGH)
RAM Address: 68054ATime between opening or closing the DO relay and opening
RAM Address: 68054BBreak time for pulse dialing
RAM Address: 68054CMake time for pulse dialing
RAM Address: 68054DTime between final OHDI relay closure and DO relay opening
RAM Address: 68054EMinimum pause between dialed digits (pulse dial mode)
RAM Address: 68054FTime waited when a pause is entered at the operation panel
RAM Address: 680550DTMF tone on time
RAM Address: 680551DTMF tone off time
RAM Address: 680552Tone attenuation level of DTMF signals while dialing
RAM Address: 680553Tone attenuation value difference between high frequency
RAM Address: 680572Acceptable ringing signal frequency: range1, upper limit
RAM Address: 680573Acceptable ringing signal frequency: range1, lower limit
RAM Address: 680574Acceptable ringing signal frequency: range2, upper limit
RAM Address: 680575Acceptable ringing signal frequency: range2, lower limit
RAM Address: 680576Number of rings until a call is detected
RAM Address: 680577Minimum required length of the first ring
RAM Address: 680578Minimum required length of the second and subsequent rings
RAM Address: 680579Ringing signal detection reset time (LOW)
RAM Address: 68057ARinging signal detection reset time (HIGH)
RAM Address: 6805B4PSTN: Tx level from the modem
RAM Address: 6805DAT.30 T1 timer
Russian-C (Fax Option)
ParametersDescriptions
the OHDI relay
or closing
tone and low frequency tone in DTMF signals
Date:
08-May-00
No.:
RA265011
Page 29
!"#$%&T
Reissued: 15-May-00
echnicalBulletin
PAGE: 1/3
Model:
Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
BICU firmware history for the Russian-C
USA Model
ROM History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
A2675532VersionC. SUMProduction
B1.57C4BA1st Mass Prod.
C1.64A2BFOctober Prod. ‘99
D1.74C99DMarch Prod. ‘00
Part information
Electrical
Transmit/receive
29-Feb-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265003b
E1.77B85FApril Prod. ‘00
European Model
A2675533VersionC. SUMProduction
B1.5786E81st Mass Prod.
C1.64837FOctober Prod. ‘99
D1.74141CMarch Prod. ‘00
E1.77043FApril Prod. ‘00
Asia/Taiwan Models
A2675534VersionC. SUMProduction
A1.64A2BF1st Mass Prod.
B1.710FE8April Prod. ‘00
C1.740C26March Prod. ‘00
D1.7769A8April Prod. ‘00
Page 30
!"#$%&T
Reissued: 15-May-00
echnicalBulletin
PAGE: 2/3
Model:
Russian-C1
Date:
29-Feb-00
China Model
A2675536VersionC. SUMProduction
A1.747FBA1st Mass Prod.
B1.778068April Prod. ‘00
Symptoms CorrectedUSAEUAsiaCHN
Specification change:
The default value of SP5-501-002 has been changed to “0”.
Under the following conditions, the stapling function cannot be used
after clearing a copy jam:
1. A4 sideways feed
2. The finisher front cover is opened while the last copy is being
exited to the finisher.
Under the following conditions, the PM alarm does not activate when
the PM counter reaches the value set in SP5-501-001 (PM Alarm
interval):
No.:
RA265003b
EEDB
EEDB
EEDB
1. SP5-816 (CSS function) = 0 (default setting)
2. SP5-501-002 (PM Alarm) = 1 (default setting)
Chinese translation error.---------A
In Printer mode, dirty background may appear near the leading edge of the
first page printed out following a paper jam recovery.
When exiting to the 1-bin tray, a paper jam may occur caused by the
bouncing of the exit sensor actuator.
The machine goes into Energy Saver Mode when the operator presses the
Energy Saver Mode key while a print job is in progress. However, when the
operator brings the machine out of the mode and returns to System
Settings or Copy Features (both user tools), a message is displayed asking
the operator to wait and the machine returns to the main copy screen. At
this time, the LED for the user tools key is lit, and all indicators except the
LCD report that the machine is still in User Tools.
If the operator enters System Settings or Copy Features (both user tools)
from Fax, Printer or Scanner mode while a duplex or staple copy job is in
progress, the “Copy in progress” screen is displayed.
The message is still displayed even if the operator presses the User Tools
Key to return to the main copy screen after the copy job finishes.
DDCA
DDCA
CC------
CC------
Page 31
!"#$%&T
Reissued: 15-May-00
echnicalBulletin
PAGE: 3/3
Model:
If a jam occurs while printing out a counter report, the jam indication is
displayed but soon disappears. The machine then returns to the counter
display screen. In addition, if the paper end condition occurs while the
paper is being fed, the machine returns to the counter display screen
without properly displaying “Set A4 (81/2 x 11) paper in tray”.
On machines with an optional LCT installed, SC507 can occur when the
main power switch is turned on under the following conditions: 1. The LCT
end fence is not in the HP and 2. The bottom plate for the right tray is not
detected by the lower HP sensor.
However, these occurrence conditions are very rare.
“1/2” appears in the Key Operator Tools display (user tools – system
settings).
After the operator exits either of the following screens with the User Tools
key and starts a copy job, the first sheet is printed out as the counter list.
• System Settings – Key Operator Tools – Counter List Printing
• Copy Features– Key Operator Tools – Counter List Printing
Corrects Taiwanese translation error.------B---
Russian-C1
Symptoms CorrectedUSAEUAsiaCHN
Date:
29-Feb-00
No.:
RA265003b
CC------
CC------
CC------
CCA---
Page 32
!"#$%T
Reissued: 09-Jun-00
echnicalBulletin
PAGE: 1/2
Model:
Russian-C1
Date:
15-May-00
No.:
RA265012a
RTB Correction
The illustration (Fig. 2) has changed as shown below.
Subject:
From:
Classification:
Original skew correction
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
S. Tomoe
SYMPTOM
Skewed image on the original cannot be corrected even if the ADF position is changed
(refer to figure 1).
CAUSE
The present shift range is not wide enough to completely correct the skew in some cases.
The shift range is limited to 0.5 mm because the hinge is stopped by the scanner rear
upper cover.
SOLUTION
To expand the shift range, the bottom of the hinge has been shortened by 1 mm and the
opening in the scanner rear upper cover has been expanded by 1.5 mm. See figure 2.
Modification information:
Right hinge:
Part number: A8581831B ! C (suffix has been changed)
Cut-in serial numbers:
A858-17: 2607301842~ (from January 2000 production)
A858-26: 4C28200001~ (from February 2000 production)
A858-55: L0580820001~ (from February 2000 production)
Scanner Rear Upper Cover:
Part number: A2671251F ! G (suffix has been changed)
No cut-in serial numbers
ACTION IN THE FIELD
If the skewing on the original cannot be corrected, replace the scanner rear upper cover
and/or the right hinge of the ADF.
Page 33
!"#$%T
Reissued: 09-Jun-00
echnicalBulletin
PAGE: 2/2
Model:
Russian-C1
Scanner rear upper cover
Figure 1
Date:
15-May-00
No.:
RA265012a
Right hinge
A: 58.5 mm 57.5 mm
69.5 mm
59.5 mm
61.0 mm
71.0 mm
A
Figure 2
Page 34
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
The drum does not turn
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
15-May-00
Prepared by:
No.:
RA265013
S. Tomoe
Action required
Service manual revision
Retrofit information
SYMPTOM
The drum does not turn, causing a paper jam at the drum.
CAUSE
The pin on the drum drive shaft is being pushed all the way into the shaft. As a result, the
drum drive coupler cannot rotate.
SOLUTION
After discovering a problem with the tool used in motor production, the factory changed
back to the old tool until an improved one could be manufactured. During this interval, the
motors produced up until the tool change were collected. Also, the motors in production
were checked for any misaligned pins and marked with a black or red spot next to the lot
number.
Even though the manufacturer collected the motors, there is a possibility that not all were
recalled. However, we believe that the occurrence rate in the field is low because there
was a very short interval between the tool change and the discovery of the problem/motor
collection.
The new tool was later completed and has been used in motor production since December
1999.
Page 35
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
Optional memory (Printer Option)
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other (Specification information)
Part information
Electrical
Transmit/receive
Date:
22-May-00
Prepared by:
No.:
RA265014
S. Tomoe
Action required
Service manual revision
Retrofit information
This bulletin is to clarify the memory requirements for the available printer functions. The
section for the printer controller in the Service Manual does not mention this information
clearly.
FunctionOptional memoryOptional HDD
Sort / Sort with StaplingO---
Rotate Sort---O
DuplexO---
Proof Print---O
O = required for this function --- = not required for this function
Page 36
echnicalBulletin
T
PAGE: 1/4
Model:
Subject:
From:
Russian-C1
PCU Problems
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
04-Jul-00
Prepared by:
No.:
RA265015
S. Tomoe
Action required
Service manual revision
Retrofit information
This RTB will explain troubleshooting procedures for the following PCU symptoms: fullpage dirty background, side-edge dirty background, broken gear.
1. Full-page Dirty Background Copy
Symptom:
Dirty background on copies.
Cause:
Some PCUs produced from August to October 1999 contain developer which does not
maintain the correct Q/M while the machine is used. This causes toner to scatter from
the development unit, leading to dirty background. The occurrence rate is 2 to 3 % of
the total number of units produced from August to October 1999. The lot numbers of
the affected PCUs are as follows:
The factory procedures for controlling developer characteristics have been changed so
that the developer will maintain the correct Q/M. These changes are effective as of
November 1999 production lots.
Page 37
echnical Bulletin
T
PAGE: 2/4
Model:
2. Gear Broken
Symptom:
Cause:
Countermeasure:
Russian-C1
PCU internal gear breaks.
The bushing for the toner supply coil shaft (PCU) partially melts from friction between
the shaft and bushing. This causes the shaft to lock and the gear inside the PCU to
break.
The material of the bushing has been changed. This modification has been applied
from the following cut-in serial numbers:
When either of the problems described above occurs in the field, please do the attached
procedure (next page) in order to confirm the actual cause. Then please forward the
data listed below to the dealer.
1. Machine Serial Number
2. PCU lot number. The lot number can be found on the top part of the PCU (11 digits).
3. SMC printout:
For dirty background, SMC printout before replacing the PCU.
For a broken gear, SMC printout after replacing the PCU.
4. Copy samples made with the defective PCU (Dirty background copy only)
5. Attached procedure.
Page 38
echnical Bulletin
T
PAGE: 3/4
Model:
Russian-C1
Symptom:
Dirty background
Does dirty background
occur at installation?
No
Action:
Perform the following procedure.
Enter copier SP2-220.
Input the data into table 1.
Note:
Vt 2.30/2.29 Vsp 3.66 ...........
| |
Vt Vref
Vsp <= 0.1, Vsg = 3.7~4.5,
Vt = 2.7~2.8, Vref = 2.7~2.8 ?
Yes
1. Make 20 ~ 50 copies of the OS-A3 Test Chart.
2. Turn the power off and on.
3. Enter SP2-220
4. Input the data into Table 2.
PCU Problem
Yes
No
Other components are causing the
problem.
Yes
Date:
04-Jul-00
Symptom:
1. Add Toner Indicator does not turn off.
2. Light copy image
3. Noise generated from the PCU
Action:
Perform the following procedure.
Enter copier SP2-220.
Input the data into table 3.
Note:
Vt 2.30/2.29 Vsp 3.66 ...........
| |
Vt Vref
No
1. Change the value of SP2-926 to 2.78.
2. Turn the power off and on.
3. Make 20 ~ 50 copies of the OS-A3 Test Chart.
4. Turn the power off and on.
5. Enter SP2-220
6. Input the data into Table 4.
Vsp <= 0.15?
Yes
No.:
RA265015
Vsp <= 0.1?
Yes
Replace the PCU.
Send the defective PCU, image samples, and
SMC print with this sheet to the appropriate Ricoh
subsidiary.
Table 1
VtVrefVsgVspVsdp
Table 2
VtVrefVsgVspVsdp
Table 3
VtVrefVsgVspVsdp
Table 4
VtVrefVsgVspVsdp
No
Problem is solved.
Country
Company
Date
Machine serial #
PCU Lot. #
Copy samples
SMC print
Does dirty
background occur?
No
Other components are causing the
problem.
Yes, No
Yes, No
No
Vsp <= 0.15?
Yes
Action:
Check whether or not the toner supply auger
rotates. Refer to the following procedure:
1. Remove the translucent cap on the center of
the PCU.
2. Turn the development roller using the coupler.
3. Check to see if the auger is rotating.
Is the auger rotating?
Cause:
The bushing of the toner supply auger has been
locked.
Replace the PCU.
Send the defective PCU, image samples, and
SMC print with this sheet to the appropriate Ricoh
subsidiary.
Page 39
echnical Bulletin
T
PAGE: 4/4
Model:
4. Side-edge Dirty Background
Symptom:
Cause:
Action required:
Russian-C1
Dirty background on the edges of paper.
When the toner concentration in the development unit rises, toner tends to scatter
onto the transfer roller. As a result, dirty background appears at the edges of the
paper as well as on the entire back side of the paper.
1. Check Vsp after turning the main switch on. Make 20 sky shot copies. After turning
the main switch off and on, check Vsp. If Vsp is higher than before, the developer is
not defective.
2. Change the value of SP2-929 (Vref upper Limit) from 280 (2.80V) to 320 (3.20V).
*Toner concentration will be lowered to 1.6%.
3. Change the value of SP9-920 (TD (V/wt%) Setting) from 40 to 10 with the following
procedure.
Enter SP9 and Press "Text key", "Auto Image Density key" and "# key" at the same
time, then enter 920.
*The sensitivity of the sensor is increased. Do not change the setting of other SP9xxx modes.
4. Clean the transfer unit, then make 20 copies.
Date:
04-Jul-00
No.:
RA265015
Page 40
!"#$%T
echnicalBulletin
PAGE: 1/1
Model:
Subject:
From:
Russian-C (Fax Option)
Manual Correction - LCT Paper Feed Selection
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
10-Jul-00
Prepared by:
No.:
RA265016
M. Mano
Action required
Service manual revision
Retrofit information
This RTB explains two Service Manual corrections and the solution to a related symptom.
! Please correct your Service Manuals as follows:
1. 6800CF(H) - User Parameter SW 15 (SWUSR_0F) bits 0, 1 and 2, page 4-87:
The setting option labeled as "1 0 1 LCT" was mistakenly included. This should be
deleted.
2. Printer Switch 02, page 4-37:
LCT Usage for fax printing (bit 4) was also a misprint. Bit 4 should be ‘Not used’ (the same
as bits 5 to 7). In addition, bit 2 should read as follows:
Old:
Bit NoFUNCTION
2
3rd paper feed station usage for fax printing
0: Enabled
1: Disabled
New:
Bit NoFUNCTION
23rd paper feed station usage for fax printing (includes
LCT)
0: Enabled
1: Disabled
These corrections are necessary because the option installed just under the mainframe
(LCT or Paper Feed Tray 1) is always recognized as Tray 3. Therefore, to enable or
disable fax printout with these switches, Tray 3 must be selected.
! Related symptom and solution:
Symptom:
Paper feed from the LCT is not possible with the fax application even if the LCT is selected
for fax printout with User Parameter SW 15 (SWUSR_0F), page 4-87.
Solution:
As described above, select Tray 3 to enable fax printout from the LCT.
Page 41
Reissued: 09-Aug-00
echnicalBulletin
T
PAGE: 1/1
Model:
Russian-C1
Date:
RTB Correction
The items in bold Italics have been corrected or added.
Subject:
From:
Classification:
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Printer firmware history for the Russian-C1.
For Other Models
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004b
For Lanier
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
Symptoms Corrected
(for older symptoms, please refer to previous bulletins)
If a tray SC occurs during electrical sort (collation) printing, the error message
does not appear on the LCD.
The NIB NVRAM back-up and restore function (SP mode: Service Tools “L: NIB
read/write”) is no longer valid.
Note: Please refer to RTB No. RA265008 for details.
Other
models
DC
DC
Lanier
Page 42
RICOHTechnical BulletinPAGE: 1/4
Reissued: 25-Aug-00
Model:
Russian-C
Date:
28-Apr-00
No.:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
ROM History (Russian-C Fax Option)
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Oth e r ( )
Part information
Electrical
Transmit/receive
Firmware history for the Russian-C Fax Option
USA Model
File No.
A2685582(A268Uxxx)VersionC.SUMProduction
B00210.0348D41st Mass Prod.
C00313.03AE2EDecember Prod. ‘99
D00421.00FFEEAugust Prod. ‘00
European Model
Prepared by:
Action required
Service manual revision
Retrofit information
M.Mano
RA265009a
File No.
A2685584(A268Exxx)VersionC.SUMProduction
C10310.0325121st Mass Prod.
D10412.0135B2November Prod. ‘99
Symptom Corrected (new symptoms only - for older ones,
see the older bulletins)
The ICB-1 functions are available.
When the use of the PSTN-2 line is changed to Rx only, the
settings for PSTN-2 cannot be changed.
The machine displays the clock for 12:xx as 0:xx
When a value more than 20H is input for the incoming signal
detection level (RAM address 6804BD), the minimum signal
strength decreases.
* The maximum value for this address is 1FH.
Even though the following bit switch settings should disable
the File Retention function, the machine retains files for 24
hours:
User Parameter switch 24 (swusr_18):
(bit1, bit0) = (1, 0)
When using the Create Margin Transmission function and
the rear side image needs to be rotated 180 degrees, the
margin for the rear s id e is placed on the right (instead of th e
left).
A ghost image may appear on the left of the page in JBIG
direct transmission mode during dual operation.
(The page width data is occasionally not received before
making the page.)
When the use of the PSTN-2 line is changed to Rx only, the
setting of PSTN-2 cannot be changed.
When over 20H is input for the incoming signal detection
level (RAM address 6804BD), the minimum signal strength
decreases.
The maximum value for this address is 1FH.
The PTT approval for Hungary has been passed.
The following country code will be added for Hungary:
22H (34)
When over 20H is input for the incoming signal detection level (RAM
address 6805BD), the minimum signal strength decreases.
The maximum value for this address is 1FH.
No.:
RA265017
M. Mano
Action required
Service manual revision
Retrofit information
Version
B
B
Page 50
Reissued: 04-Oct-00
echnicalBulletin
T
PAGE: 1/2
Model:
Russian-C1
Date:
RTB Correction
The Items in bold italics have been corrected or added.
Subject:
From:
Classification:
ROM History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
BICU firmware history for the Russian-C1
USA Model
A2675532VersionC. SUMProduction
B1.57C4BA1st Mass Prod.
C1.64A2BFOctober Prod. ‘99
D1.74C99DMarch Prod. ‘00
E1.77B85FApril Prod. ‘00
29-Feb-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265003c
F1.8499B6September Prod. ‘00
European Model
A2675533VersionC. SUMProduction
B1.5786E81st Mass Prod.
C1.64837FOctober Prod. ‘99
D1.74141CMarch Prod. ‘00
E1.77043FApril Prod. ‘00
F1.84A504September Prod. ‘00
Asia/Taiwan Models
A2675534VersionC. SUMProduction
A1.64A2BF1st Mass Prod.
B1.710FE8April Prod. ‘00
C1.740C26March Prod. ‘00
D1.7769A8April Prod. ‘00
E1.841CE2September Prod. ‘00
Page 51
Reissued: 04-Oct-00
echnicalBulletin
T
PAGE: 2/2
Model:
Russian-C1
Date:
China Model
A2675536VersionC. SUMProduction
A1.747FBA1st Mass Prod.
B1.778068April Prod. ‘00
C1.84735ASeptember Prod. ‘00
Russia Model
A2675537VersionC. SUMProduction
1.8024041st Mass Prod.
A1.84F452September Prod. ‘00
Symptom Corrected (new ones only – see older bulletins for
other symptoms corrected)
To minimize dirty background on copies, TD sensor sensitivity:
S will change as follows, depending on the Vref value entered:
29-Feb-00
USAEUAsiaCHNRU
FFEC---
No.:
RA265003c
VrefSensitivity: S
1 ~ 2.7 0.4
2.8 ~ 3.00.2
3.1 ~ 3.20.1
If the main scan magnification (SP2-998) is set at 0.1 when using
the printer function or receiving a fax at 400dpi, the image will
be stretched along the main scan direction.
One of the selections for Output Tray Priority (UP mode –
System Settings) has been changed as follows:
[Shift Tray]
Although specifications prohibit it, the machine is able to make
copies under the following conditions:
1. Special size is selected for paper tray 2
2. Combine Mode is selected (several originals onto doublesided copies).
The following title descriptions for SP and Sales Modes have
been changed:
[Serviceman]
[Salesman]
!!!!
[Finisher Tray]
!!!!
[Service]
!!!!
[Sales]
FFEC---
FFECA
FFEC---
FFECA
The firmware version will be displayed when the main switch is
turned on.
------------A
Page 52
Reissued: 04-Oct-00
echnicalBulletin
T
PAGE: 1/2
Model:
Russian-C
Date:
RTB Correction
The Items in bold italics have been corrected or added.
Subject:
From:
Classification:
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Printer firmware history for the Russian-C1
Other Models
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004c
E1.4.00637September Prod. ‘00
Lanier Model
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
Page 53
Reissued: 04-Oct-00
echnicalBulletin
T
PAGE: 2/2
Model:
Symptom Corrected (new ones only – see older bulletins for other symptoms
The printed area is shifted slightly when “Unit of Measure” is defined
using the macro command.
With Raster images, sometimes part of the right edge of the printable
area comes out blank.
Italian and Spanish text characters overlap each other on the
configuration page error log.
The following title on the configuration page has been changed:
“Printer Name (NetWare)”
If the optional memory and PS option are not installed, A3-size images read by a
scanner cannot be printed out.
Russian-C
corrected)
!!!!
“Printer Name”.
Date:
08-Mar-00
No.:
Other
models
E---
E---
E---
E---
E---
RA265004c
Lanier
Page 54
Reissued: 26-Oct-00
echnicalBulletin
T
PAGE: 1/2
Model:
Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Printer firmware history for the Russian-C1.
Items in bold italics have been corrected or added.
Lanier
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004d
Others
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
E1.4.00637September Prod. ‘00
F1.4.41507November Prod. ‘00
Page 55
Reissued: 26-Oct-00
echnicalBulletin
T
PAGE: 2/2
Model:
Part of the image is missing for the first two pages when printing out with the
Unico2000 CAD application.
When printing out with the Microsoft Mini Driver for Windows NT Terminal
Server, the image created is sometimes out of specification.
When printing out a file made with certain CAD applications for DOS without
using a printer driver, thick lines on the original image appear thin on the
output.
** To activate this correction, it is necessary to set Bit SW3, bit 3 to 1
(0=Disabled, 1=Enabled).
Firmware modified to meet the functional specifications of the Tray Priority
function.
In some stapling modes, the printing image direction is not same as the
copier’s.
** To activate this correction, it is necessary to set Bit SW3, bit 7 to 1
(0=Disabled, 1=Enabled).
The print speed slows down during continuous printing of a 1-page job.
** To activate this correction, it is necessary to set Bit SW3, bit 2 to 1
(0=Disabled, 1=Enabled) and SET BIT SW3, bit 4 to 1 (DAZEL support function
disabled). The correction will not be effective if both of these switches are
enabled.
Firmware modified so that the controller can connect to and be used with the
DAZEL System. However, the Russian-C is not yet officially certified by DAZEL
Corp.
When you enable this function, it is necessary to do the following:
-Upgrade the NIB firmware to version 4.0.6 or later and the PS3 firmware to
version 1.2.4 or later.
-Set the NIC to bi-directional-mode (refer to the NIC manual).
-Do not set Bit SW3, bit 2 to 1 (as explained above, these two switches should
not be simultaneously enabled).
Russian-C1
Symptom Corrected
Date:
08-Mar-00
No.:
Other
models
F---
F---
F---
F---
F---
F---
F---
RA265004d
Lanier
To deactivate the DAZEL support function, set Bit SW3, bit 4 to 1 (0=Enabled,
1=Disabled).
Page 56
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
Firmware history for the Capture Box Type 270
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
27-Oct-00
Prepared by:
No.:
RA265018
K. Moriizumi
Action required
Service manual revision
Retrofit information
This is to inform you of the firmware release for the Russian-C Capture Box Option Type
270.
Note: Install the following firmware or later version in Russian-C mainframes that contain
the Capture Box Option Type 270.
BICU
USA Model
A2675540VersionC. SUMProduction
1.84NOA1NA0AC01st Mass Prod.
FCU
USA Model
A2685582VersionC. SUMProduction
D21.00FFEEAugust 2000 prod.
Important:
Install the BICU firmware (A2675540) in the Russian-C mainframes that contain the
Capture Box Option Type 270. If “User Select” is displayed among the application keys on
the Russian-C operation panel, the Capture Box Option Type 270 has been installed.
Install the standard BICU firmware (A2675532) in standard Russian-C mainframes that donot contain the Capture Box Option Type 270.
If the wrong BICU firmware is installed, an SC error will occur and/or the Capture Box
Option will not function.
Page 57
Reissued: 08-Dec-00
echnicalBulletin
T
PAGE: 1/2
Model:
Russian-C1
Date:
08-Mar-00
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Printer Firmware History
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
This is to inform you of the printer firmware history for the Russian-C1.
Items in bold italics have been corrected or added.
For Other Models
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
No.:
S. Tomoe
RA265004e
For Lanier
B3065283VersionC. SUMProduction
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
E1.4.00637September Prod. ‘00
F1.4.41507November Prod. ‘00
G1.4.8DAFCDecember Prod. ‘00
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
Page 58
Reissued: 08-Dec-00
echnicalBulletin
T
PAGE: 2/2
Model:
Symptoms Corrected (New symptoms only – for older ones, see earlier RTBs)
When printing out from a certain DOS application, the right part of the
internal print pattern is missing.
When using a certain DOS CAD application, the paper size and/or paper
feed direction are not sent to the controller, and the machine uses the
defaults.
When printing out with a certain macro, the frame and lower area of the
image are missing.
When using the Dazel system, the job cannot be reset after the paper
feed tray reaches paper end.
Russian-C1
Date:
08-Mar-00
No.:
Other
models
RA265004e
Lanier
G
G
G
G
---
---
---
---
Page 59
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
Firmware history for the Capture Box Type270
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
14-Dec-00
Prepared by:
No.:
RA265019
K. Moriizumi
Action required
Service manual revision
Retrofit information
Firmware release for the Russian-C Capture Box Option Type 270.
Note: Install the following firmware or a later version in Russian-C mainframes that contain
the Capture Box Option Type 270.
BICU
For European Models
A2675541VersionC. SUMProduction
“ “1.85NOA1EU75D41st Mass Prod.
FCU
For European Models
A2685584VersionC. SUMProduction
K23.004775November 2000 prod.
For European 2nd Language
A2685585VersionC. SUM
F23.00E608
For European 3rd Language
A2685586VersionC. SUM
F23.00FAD9
Important: BICU Firmware
Install BICU firmware A2675541 in the Russian-C mainframes that contain the Capture Box
Option Type 270. If “User Select” is displayed among the application keys on the Russian-C
operation panel, the Capture Box Option Type 270 has been installed.
Install standard BICU firmware A2675533 in standard Russian-C mainframes that do not contain
the Capture Box Option Type 270.
If the wrong BICU firmware is installed, an SC error will occur and/or the Capture Box Option will
not function.
Page 60
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
Firmware history for the Capture Box Type270
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
14-Dec-00
Prepared by:
No.:
RA265020
K. Moriizumi
Action required
Service manual revision
Retrofit information
Firmware history for the Russian-C Capture Box Option Type270.
Note: Install the following firmware or a later version in Russian-C mainframes that contain
the Capture Box Option Type 270.
BICU
For USA Models
A2675540VersionC. SUMProduction
“ “1.84NOA1NA0AC01st Mass Prod.
A1.85NOA1NAD3CNovember 2000 Prod.
For Europe Models
A2675541VersionC. SUMProduction
“ “1.85NOA1EU75D41st Mass Prod.
Symptom Corrected
Sotware bugs:
1. Even if Printer or Fax has been set with the User Select function priority, “Copier” is
displayed at power up.
2. Even if Printer has been set with the User Select function priority, the LED for the
User Select key is lit.
USAEU
A-
Page 61
!"#$%T
Reissued: 23-Oct-00
echnicalBulletin
PAGE: 1/5
Model:
Russian-C
Date:
28-Apr-00
No.:
RTB Correction
The items in bold italics have been corrected.
Subject:
From:
Classification:
ROM History (Russian-C Fax Option)
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Firmware history for the Russian-C Fax Option
- USA Model -
File No.
A2685582(A268Uxxx)VersionC.SUMProduction
B00210.0348D41st Mass Prod.
C00313.03AE2EDecember Prod. ‘99
D00421.00FFEEAugust Prod. ‘00
- European Model -
Prepared by:
Action required
Service manual revision
Retrofit information
M. Mano
RA265009c
File No.
A2685584(A268Exxx)VersionC.SUMProduction
C10310.0325121st Mass Prod.
D10412.0135B2November Prod. ‘99
Nothing New – Only the Checksums etc on p 1 and p 2
were changed
ICB-1 function is available.
When the use of the PSTN-2 line is changed to Rx only, the
setting of PSTN-2 cannot be changed.
The machine displays the clock for 12:xx as 0:xx
When over 20H is input for the Incoming signal detection level
(RAM address 6804BD), the minimum signal strength decreases.
* Maximum value for this address is 1FH.
When sending an original wider than the maximum paper width of
the receiving machine (Auto-Reduction OFF / JBIG
compression), the machine cuts the image to the smaller size but
sends the left most area of the image instead of the central area.
The symptom occurs only when the following software is used:
European model:A2685584C (ver. 16.01)
European 2
European 3
Asian model:A2685587D (ver. 17.02)
Even though the following bit switch settings should disable the
File Retention function, the machine retains files for 24 hours:
User Parameter switch 24 (swusr_18):
(bit1, bit0) = (1, 0)
When bit 4 of Communiation switch07 is 1 (Fallback from G4 to
G3 when G4 communication fails on the ISDN B-channel is
enabled) and G4 communication error occurs on the ISDN Bchannel (ADF mode), the machine falls back to G3 and resumes
transmission from the second page. This is because the first
page has already exited from the ADF.
The PTT approbal for Hangary has been passed.
The following country code will be added for Hangary:
22H (34)
The following Chinese characters have been corrected for the
KANTAI display language:
nd
language:A2685585C (ver. 16.01)
rd
language:A2685586C (ver. 16.01)
No.:
RA265009c
USAEUEU2EU3Asia/
TWN
D --- -
DJEE-
D --- -
DJEE-
- HDD D
D HDD D
- HDD C
- HDD -
- --- C
>
>
When using the Create Margin Transmission function and the
rear side image needs to be rotated 180 degrees, the margin for
the rear side is placed on the right (instead of the left).
The ghost image may appear on the left of the page in JBIG
direct transmission mode during the dual operation.
(The page width data is rarely not received before making the
page.)
PC Fax Expander is not recognized ( only for Asia version).
DGCCC
DGCCC
- --- B
Page 64
!"#$%T
Reissued: 23-Oct-00
echnicalBulletin
PAGE: 4/5
Model:
Russian-C
Date:
28-Apr-00
Symptom Corrected
For CTR21 approval, the unique dialing requirement
(Communication SW06) are not used and their default setting
were changed from “Enabled” to “Disabled”. And G4 country
code in France has been changed from 00 to 02 (UK).
Quick Dial is not working when the country code is set to France.
If this problem occurs on old firmware, please change the COM
SW06 - bit4 from 1 to 0.
Conditions for printing (Scan Router):
It determines whether or not the machine will print out the
incomoing fax when transmission is made to the Scan Router
Professional Station.
User Parameter switch31 bit2
0: Document not printed1: Document will be printed
When the received CSI have only space data, it is ignored by this
version firmware.
Line Error Marks on received page:
A mark will be printed on the left edge of the page anywhere a
line error has occurred in the data if following bit is enabled.
System switch00 bit4
0: Disabled1: Enabled
In order to ensure that the NSF/DIS signals (from the machine
that is to receive the facsimile) will successfully be received by
the sender, the transmission duration of these signals can now be
extended as follows:
Symptom Corrected (new ones only; for old ones, see older
RTBs)
The machine transfers messages received by G4 polling
reception to the ICB-1.
The RTC detection conditions have been changed from 3 to
2 EOL signals.
ICB-1 function is available.
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Printer firmware history for the Russian-C1.
Items in bold italics have been corrected or added.
Other Models
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004f
Lanier
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
E1.4.00637September Prod. ‘00
F1.4.41507November Prod. ‘00
G1.4.8DAFCDecember Prod. ‘00
H1.4.98F64January Prod. ‘01
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
D1.4.9B6C9January Prod. ‘01
Page 71
Reissued: 22-Jan-01
echnicalBulletin
T
PAGE: 2/3
Model:
Symptom Corrected (new symptoms and changes only – for others, see older
Russian-C1
bulletins)
If Add Toner occurs during printing with staple mode, the machine does
Date:
08-Mar-00
No.:
Other
models
RA265004f
Lanier
H
not print out the remaining page even if the toner bottle is replaced.
After an A4 LEF print job is completed and the ON Line key is pressed, it
H
takes a relatively long time to enter OFF Line mode.
When printing an MS Word 97 or WordPad document using the PCL 6
H
driver with the following functions enabled, the front side is printed out
with Top Binding and the rear side is printed out with Side Binding:
Duplex-Side Binding and in Paper mode Different Paper for First Page
(First Page from 1 or 2 Tray and Other Pages from Tray 3 or 4;
Destination – Printer Default).
This problem doesn’t occur with the PCL5e driver.
The controller stalls when the test document (A4 LEF) for Corel Draw 9
H
is printed.
The “Paper Type” information is not listed in the configuration sheet
H
when the by-pass feed unit is installed.
When printing out from a certain DOS application, the right part of the internal
G
print pattern is missing.
When using a certain DOS (CAD) application, the paper size and/or paper
G
feed direction are not sent to the controller, and the machine uses the
defaults.
When printing out with a certain macro, the frame and lower area of the
G
image are missing.
When using the Dazel system, the job cannot be reset after the paper feed
G
tray reaches paper end.
Part of the image is missing for the first two pages when printing out with the
Unico2000 CAD application.
When printing out with the Microsoft Mini Driver for Windows NT Terminal Server, the
image created is sometimes out of specification.
When printing out a file made with certain CAD applications for DOS without using a
printer driver, thick lines on the original image appear thin on the output.
** To activate this correction, it is necessary to set Bit SW3, bit 3 to 1
(0=disabled, 1=Enabled).
Firmware modified to meet the functional specifications of the Tray Priority function.FD
FD
FD
FD
D
D
D
D
D
D
D
D
D
In some stapling modes, the printing image direction is not same as the copier’s.
** To activate this correction, it is necessary to set Bit SW3, bit 7 to 1 (0=disabled,
1=Enabled).
The print speed slows down during consecutive printing of 1-page jobs.
** To activate this correction, it is necessary to set Bit SW3, bit 2 to 1 (0=Disabled,
1=Enabled) and set BIT SW3, bit 4 to 1 (DAZEL support function disabled). The
correction will not be effective if both of these switches are enabled.
Firmware modified so that the controller can connect to and be used with the DAZEL
System. However, the Russian-C is not yet officially certified by DAZEL Corp.
When you enable this function, it is necessary to do the following:
-Upgrade the NIB firmware to version 4.0.6 or later and the PS3 firmware to version
1.2.4 or later.
-Set the NIC to bi-directional mode (refer to the NIC manual).
-Do not set Bit SW3, bit 2 to 1 (as explained above, these two SW should not be
simultaneously enabled).
To deactivate the DAZEL support function, set Bit SW3, bit 4 to 1 (0=Enabled,
FD
FD
FD
Page 72
Reissued: 22-Jan-01
echnicalBulletin
T
PAGE: 3/3
Model:
1=Disabled).
The printed area is shifted slightly when “Unit of Measure” is defined using the macro
command.
With Raster images, sometimes part of the right edge of the printable area comes out
blank.
Italian and Spanish text characters overlap each other on the configuration page error
log.
The following title on the configuration page has been changed:
“Printer Name (NetWare)” ! “Printer Name”.
If the optional memory and PS option are not installed, A3-size images read by a
scanner cannot be printed out.
Russian-C1
Date:
08-Mar-00
No.:
ED
ED
ED
ED
ED
RA265004f
Page 73
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1 (Scanner Option Type 270)
Scanner controller does not connect to a hub
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
24-Jan-01
Prepared by:
No.:
RA265021
S. Tomoe
Action required
Service manual revision
Retrofit information
SYMPTOM
The scanner controller may not connect with some types of hubs at 10 Mbps, depending
on the particular hub and scanner NIB combination.
CAUSE
The OSC5 oscillator on the scanner controller does not match the particular hub.
SOLUTION
The OSC5 oscillator has been changed. The new controller is A8775311 (A8775310N).
Note: Initially, this was only a suffix change, however later we changed the part number to
A8775311.
Page 74
Reissued: 20-Feb-01
echnicalBulletin
T
PAGE: 1/3
Model:
Russian-C1
Date:
29-Feb-00
No.:
RA265003d
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
ROM History
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
S. Tomoe
This is to inform you of the BICU firmware history for the Russian-C1. Items in bold italics
have been corrected or added.
For N.A. Models
A2675532VersionC. SUMProduction
B1.57C4BA1st Mass Prod.
C1.64A2BFOctober Prod. ‘99
D1.74C99DMarch Prod. ‘00
E1.77B85FApril Prod. ‘00
F1.8499B6September Prod. ‘00
G1.874572February Prod. ‘01
For European Models
A2675533VersionC. SUMProduction
B1.5786E81st Mass Prod.
C1.64837FOctober Prod. ‘99
D1.74141CMarch Prod. ‘00
E1.77043FApril Prod. ‘00
F1.84A504September Prod. ‘00
G1.87F2FEFebruary Prod. ‘01
Page 75
Reissued: 20-Feb-01
echnicalBulletin
T
PAGE: 2/3
Model:
Russian-C1
For Asia/Taiwan Models
A2675534VersionC. SUMProduction
A1.64A2BF1st Mass Prod.
B1.710FE8April Prod. ‘00
C1.740C26March Prod. ‘00
D1.7769A8April Prod. ‘00
E1.841CE2September Prod. ‘00
F1.87CEE8February Prod. ‘01
For China Models
A2675536VersionC. SUMProduction
A1.747FBA1st Mass Prod.
B1.778068April Prod. ‘00
C1.84735ASeptember Prod. ‘00
Date:
29-Feb-00
No.:
RA265003d
D1.87847FFebruary Prod. ‘01
For Russia Models
A2675537VersionC. SUMProduction
A1.84F452September Prod. ‘00
B1.874417February Prod. ‘01
1.8024041st Mass Prod.
Page 76
Reissued: 20-Feb-01
echnicalBulletin
T
PAGE: 3/3
Model:
Occasionally, full page image data is reduced and printed on the
left side, and the right side is printed solid black in Fax and
Printer modes when the following 3 conditions exist:
1. SP2-998 (Main Scan Magnification) –1 (Engine) has a
2. The interleave function is enabled between copy and printer
3. Soon after the interleave job is finished, the machine prints
A new SP mode (SP2-993) has been added to prevent dirty
background on the rear side of the first copy. Please refer to
RTB# RA265022 for more details.
When the main power is turned on, the machine cannot detect
jammed paper remaining at the exit sensor if the interchange
unit is not installed.
Russian-C1
Symptom CorrectedUSAEUAsiaCHNRU
different value than –2 (Copy).
modes (both 600 dpi).
out an image at a resolution other than 600 dpi (e.g. fax
image, printer image at 300dpi).
Date:
29-Feb-00
GGF DB
GGF DB
GGF DB
No.:
RA265003d
Page 77
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
New SP mode
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
20-Feb-01
Prepared by:
No.:
RA265022
S. Tomoe
Action required
Service manual revision
Retrofit information
The following SP mode has been added from BICU firmware version 1.87. Please add
this SP mode description to your Service Manual.
Mode No.
Class
1 and 2
2-993*Transfer Current
Class 3
Timing
Selects the transfer current application
timing.
If “1” is selected, the machine applies the
transfer current 90 ms before the Normal
application time.
FunctionSetting
0: Normal
1: Early
Use this SP mode when dirty background
appears on the rear side of the first page.
Page 78
echnicalBulletin
T
PAGE: 1/2
Model:
Subject:
From:
Classification:
Russian-C1
Broken Black Stripes
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
SYMPTOM
Broken black stripes appear on copies (see below).
Date:
10-Apr-01
Prepared by:
No.:
RA265023
S. Tomoe
Action required
Service manual revision
Retrofit information
CAUSE
The Russian-C1 has toner recycling mechanisms. However, there are cases where broken
black stripes can appear on copies when paper dust in this recycled toner builds up on the
drum or charge roller surfaces. If the paper dust is on the charge roller surface, the stripe
intervals will be in the pitch of the roller. The cleaning mylar, which contacts the
registration roller, normally collects paper dust and prevents such copy problems.
However, when there is an abnormally large amount of paper dust present, the mylar is
not able to collect all of it, which can cause some to get into the PCU.
Page 79
echnical Bulletin
T
PAGE: 2/2
Model:
Russian-C1
Date:
10-Apr-01
No.:
RA265023
SOLUTION
Clean out the paper dust that has accumulated between the dust cleaning mylar and
registration roller:
1. Detach the support arm from the right cover, then remove the ID sensor connector and
right cover.
2. Being careful not to scratch the mylar, slide the vertical transport guide plate to one side
and remove it.
3. Remove the registration guide plate (2 screws).
4. Slide a piece of thick paper, or other material that will not scratch the roller, in between
the registration roller and mylar. Then, while sliding the paper back and forth, remove
the accumulated paper dust.
Note: Before doing this, be sure to place a piece of paper underneath the registration
roller to prevent paper dust from getting on the paper feed rollers.
In addition, we also recommend cleaning the charge roller.
Page 80
!"#$%T
Reissued: 31-May-01
echnicalBulletin
PAGE: 1/1
Model
: Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
Scanner Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Scanner firmware history for the Russian-C1.
A8775810VersionC. SUMProduction
E3.0.160321st Mass Prod.
F4.0.02E79February Prod. ‘00
G4.0.35736March Prod. ‘00
H4.0.45B8FNovember Prod. ‘00
10-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265005a
Symptom Corrected (for older corrections, see older RTBs)Suffix
Improvement:
An MTF filter is used in Text Mode to improve the quality of the scanned image.
H
Page 81
Reissued: 13-Jun-01
echnicalBulletin
T
PAGE: 1/1
Model:
Russian-C1
Date:
14-Dec-00
No.:
RA265020a
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Firmware history for the Capture Box Type270
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
K. Moriizumi
Firmware history for the Russian-C Capture Box Option Type 270.
Note: Install the following firmware or later version in Russian-C mainframes that contain
the Capture Box Option Type 270.
BICU
USA Model
A2675540VersionC. SUMProduction
“ “1.84NOA1NA0AC01st Mass Prod.
A1.85NOA1NAD3CNovember 2000 Prod.
B1.87NOA1NA4729February Prod. ‘01
Europe Model
A2675541VersionC. SUMProduction
“ “1.85NOA1EU75D41st Mass Prod.
A1.87NOA1EU0C8FFebruary Prod. ‘01
Symptoms Corrected (see earlier RTBs for earlier symptoms)
Occasionally, the full page image data is reduced and printed on the left side, and the
right side is printed solid black in fax and printer modes when the following 3 conditions
exist:
1. SP2-998 (Main Scan Magnification) –1 (Engine) has a different value than –2 (Copy).
2. The interleave function is enabled between copy and printer modes (both 600 dpi).
3. Soon after the interleave job is finished, the machine prints out an image at a
resolution other than 600 dpi (e.g. fax image, printer image at 300dpi).
USAEU
BA
A new SP mode (SP2-993) has been added to prevent dirty background on the rear side
of the first copy. Please refer to RTB# RA265022 for more details.
Just after the main power is turned on, the machine cannot detect jammed paper
remaining at the exit sensor if the interchange unit is not installed.
BA
BA
Page 82
Reissued: 09-Aug-01
echnicalBulletin
T
PAGE: 1/2
Model:
Subject:
From:
Russian-C1
Broken Black Stripes
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
10-Apr-01
Prepared by:
No.:
RA265023a
S. Tomoe
Action required
Service manual revision
Retrofit information
This RTB has been reissued to provide the countermeasure for the symptom described
below.
COUNTERMEASURE
To ensure proper charge roller cleaning, the roller cleaner has been changed from a
cleaning pad to a cleaning roller (brush type).
Broken black stripes appear on copies (see below).
Page 83
Reissued: 09-Aug-01
echnicalBulletin
T
PAGE: 2/2
Model:
Russian-C1
Date:
10-Apr-01
No.:
RA265023a
CAUSE
The Russian-C1 has toner recycling mechanisms. However there are cases where broken
black stripes (see below) can appear on copies when paper dust in this recycled toner
builds up on the drum or charge roller surfaces. If the paper dust is on the charge roller
surface, the stripe intervals will be at the pitch of the roller. The cleaning mylar, which
contacts the registration roller, normally collects paper dust and prevents such copy
problems. However, when there is an abnormally large amount of paper dust present, the
mylar is not able to collect all of it, which can cause some to get into the PCU.
SOLUTION
Clean out the paper dust that has accumulated between the dust cleaning mylar and
registration roller:
Page 84
Reissued: 09-Aug-01
echnicalBulletin
T
PAGE: 3/2
Model:
1. Detach the support arm from the right cover, remove the ID sensor connector and
remove the right cover.
2. Being careful not to scratch the mylar, slide the vertical transport guide plate to one side
and remove it.
3. Remove the registration guide plate (2 screws).
4. Slide a piece of thick paper, or other material that will not scratch the roller, in between
the registration roller and mylar. Then, while sliding the paper back and forth, remove
the accumulated paper dust.
Note: Before doing this, be sure to place a piece of paper underneath the registration
roller to prevent paper dust from getting on the paper feed rollers.
5. Clean the charge roller if possible.
Russian-C1
Date:
10-Apr-01
No.:
RA265023a
Page 85
echnicalBulletin
T
PAGE: 1/1
Model:
Subject:
From:
Russian-C1
PCU Type 320 Information
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
09-Aug-01
Prepared by:
No.:
RA265024
S. Tomoe
Action required
Service manual revision
Retrofit information
The Russian-P2 was launched in December 2000, at which time the new Russian-P2 PCU
(type 320) was also adopted for the Russian-C1. Please note the following:
1. Differences between the type 270 PCU (Russian-C1) and type 320 PCU (Russian-P2):
Developer only. The developer was changed to maintain proper image quality with the
increased print speed of the Russian-P2.
2. Interchangeability:
The Russian-C1 can use both PCUs, while the Russian-P2 can only use the new
(type 320) PCU.
3. Model codes and lot numbers:
TypeModel CodeLot Number
Russian-C13E2ymmxxxxxBuilt-in PCU
Russian-P22E1ymmxxxxx
Supply PCU
B403-005E1ymmxxxxx
B403-01GE1ymmxxxxx
B403-02NE1ymmxxxxx
B403-03RE1ymmxxxxx
B403-04SE1ymmxxxxx
B403-05FE1ymmxxxxx
B403-06LE1ymmxxxxx
Page 86
echnical Bulletin
S
T
PAGE: 1/2
Model:
Subject:
From:
Russian-C1
Image problem history caused by PCU
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
09-Aug-01
Prepared by:
No.:
RA265025
S. Tomoe
Action required
Service manual revision
Retrofit information
This RTB summarizes the history of modifications made to the PCU for various image
quality symptoms.
1.
Light Copy / Toner End / Gear Broken
CauseCountermeasureAffected Part
The bushing for the
toner supply coil
shaft partially melts.
Material of the bushing changed. ! RTB #RA265015PCU
November
1999 ~
Developer leaks out
from the cleaning
and developer tanks
and gets stuck on
the gear.
1. Sponge attached so that developer from below the
roller will not get stuck on the gear. See fig 1
2. Strip of Mylar attached so that the developer will not
fall onto the gear and stick to it. See fig 2.
ponge
Mylar
Fig.1 Fig. 2
To improve upon the previous countermeasure, the
material of the idle gear has been changed to metal.
PCU
July 2000 ~
PCU
March 2001~
Page 87
echnical Bulletin
T
PAGE: 2/2
Model:
2.
Full-page Dirty Background
CauseCountermeasureAffected Part
Toner concentration
(in the development
unit) too high.
Russian-C1
Factory procedures for regulating developer properties
changed. ! RTB #RA265015
BICU firmware changed to enhance the range of TD
sensor sensitivity (“S”). ! RTB #RA265003
Date:
09-Aug-01
No.:
RA265025
PCU
November
1999 ~
BICU
firmware ver.
1.8.4 ~
Amount of developer inserted in the PCU at the factory
changed from 365g to 345g, in order to reduce developer
mixing torque.
PCU
September
2000 ~
Page 88
Reissued: 14-Sep-01
echnicalBulletin
T
PAGE: 1/2
Model:
Russian-C1
Date:
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Classification:
Printer Firmware History
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Printer firmware history for the Russian-C1.
Items in bold italics have been corrected or added.
For Models Other than Lanier
B3065280VersionC. SUMProduction
A1.2.0A8EA1st Mass Prod.
B1.2.9B908January Prod. ‘00
08-Mar-00
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
S. Tomoe
RA265004g
C1.3.4C923March Prod. ‘00
D1.3.6E26AApril prod. ‘00
E1.4.00637September Prod. ‘00
F1.4.41507November Prod. ‘00
G1.4.8DAFCDecember Prod. ‘00
H1.4.98F64January Prod. ‘01
J1.5.4CDBBSeptember Prod. ‘01
For the Lanier Model
B3065283VersionC. SUMProduction
A1.2.0FCB91st Mass Prod.
B1.3.4E967March Prod. ‘00
C1.3.6E38CApril Prod. ‘00
D1.4.9B6C9January Prod. ‘01
E1.5.4DF94September Prod. ‘01
Page 89
Reissued: 14-Sep-01
echnicalBulletin
T
PAGE: 2/2
Model:
For Dazel: When a stack job has been cancelled, a mismatch occurs
between the actual number of pages printed out and the number
reported to the server.
The OCR font does not download to the HDD.J
With the PS driver, the printer does not print out jobs when the
Separator function has been selected.
The Configuration Sheet does not print out.J
When a job has been sent with the PS driver but the tray has not been
specified (w/manual selection), the machine does not inform Aficio
Manager of this error.
When using the PS driver for a collation print job (bypass feed), only the
st
1
A buffer size error occurs during data communication over IEEE1284
ECP.
Russian-C1
Symptom Corrected
set is printed out.
Date:
08-Mar-00
No.:
Other
models
RA265004g
Lanier
J
J
J
J
J
E
E
E
E
E
E
E
Page 90
echnicalBulletin
T
PAGE: 1/2
Model:
Subject:
From:
Russian-C1
DF Jam
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Date:
03-Oct-01
Prepared by:
No.:
RA265026
S. Tomoe
Action required
Service manual revision
Retrofit information
SYMPTOM
An original jam occurs if the leading edge contacts the pull-out roller guide while the
second side is being scanned.
Pull out Roller
Guide
CAUSE
Some left covers were produced with a slight bulge in the pull-out roller guide (0.1 – 0.5
mm). The jam does not always occur, but has a greater tendency to occur if the original
leading edge is already curled.
Page 91
echnical Bulletin
T
PAGE: 2/2
Model:
Russian-C1
Date:
03-Oct-01
No.:
RA265026
SOLUTION
If this occurs in the field, attach mylar A8589900 as shown below, effectively extending the
roller guide. (Please be sure to observe dimensions A and B).
Please correct your Russian-C1 Point to Point Diagrams as follows:
1. IOB – CN343 (Key Counter)
Location: H2
Incorrect:Correct:
CN343-1Key Counter [!24]GND
CN343-2+ 24VKey Counter Set [!24]
CN343-3Key Counter Set [!24]+ 24V
RA265027
CN343-4GNDKey Counter [!24]
2. PSU – CN286
Location: B5
Incorrect:Correct:
+24V
+24V
GND
GND
GND
+5V
CN286
-5
+24V
-7
+24V
-4
GND
-6
GND
-7
GND
-3
+5V
CN286
-5
-7
-4
-6
CN285 -7
CN285 -3
Page 93
Reissued: 05-Nov-01
S
echnical Bulletin
T
PAGE: 1/3
Model:
Russian-C1
Date:
09-Aug-01
No.:
RA265025a
RTB Correction
The items in bold italics have been corrected or added.
Subject:
From:
Image problem history caused by the PCU
Technical Services Dept., GTS Division
Classification:
Troubleshooting
Mechanical
Paper path
Other ( )
Part information
Electrical
Transmit/receive
Prepared by:
Action required
Service manual revision
Retrofit information
S. Tomoe
This RTB summarizes the history of modifications made to the PCU for various image
quality symptoms.
1.
Light Copy / Toner End / Gear Broken
CauseCountermeasureAffected Part
The bushing for the
toner supply coil
shaft partially melts.
Material of the bushing changed. ! RTB #RA265015PCU
See table 1
Developer leaks out
from the cleaning
and developer tanks
and gets stuck on
the gear.
1. Sponge attached so that developer from below the
roller will not get stuck on the gear. See fig 1
2. Strip of Mylar attached so that the developer will not
fall onto the gear and stick to it. See fig 2.
ponge
Mylar
Fig.1 Fig. 2
To improve upon the previous countermeasure, the
material of the idle gear has been changed to metal.
PCU
See table 2
PCU
See table 4
Page 94
Reissued: 05-Nov-01
echnicalBulletin
T
PAGE: 2/3
Model:
2.
Full-page Dirty Background
CauseCountermeasureEffected Part
Toner concentration
(in the development
unit) too high.
Russian-C1
Factory procedures for regulating developer properties
changed. ! RTB #RA265015
BICU firmware changed to enhance the range of TD
sensor sensitivity (“S”). ! RTB #RA265003
Date:
09-Aug-01
No.:
RA265025a
PCU
See table 1
BICU
firmware ver.
1.8.4 ~
Amount of developer included in the PCU at the factory
changed from 365g to 345g, in order to reduce developer
mixing torque.
PCU
See table 3
Cut-in Lot Number:
Table 1
Model CodeDistributors Serial Number Note
For ConsumablesB310-00Ricoh1E091000001~ October ’99 production
B310-01GesGE091000001~ October ’99 production
B310-02NashuaNE091100001~ November ’99 production
B310-03RexRE091000001~ October ’99 production
B310-04SavinSE091000001~ October ’99 production
B310-05InfotecFE091100001~ November ’99 production
B310-06LanierLE091000001~ October ’99 production
For MachineOE091004486~ October ’99 production
Table 2
Model CodeDistributors Serial Number Note
For ConsumablesB310-00Ricoh1E000604156~’99 June 30 ~
B310-01GesGE000700001~ July ‘00 production
B310-02NashuaNE000700001~ July ‘00 production
B310-03RexRE000700001~ July ‘00 production
B310-04SavinSE000700001~ July ‘00 production
B310-05InfotecFE000700001~ July ‘00 production
B310-06LanierLE000700001~ July ‘00 production
For MachinesOE000700001~ July ‘00 production
Page 95
Reissued: 05-Nov-01
echnicalBulletin
T
PAGE: 3/3
Model:
Russian-C1
Date:
09-Aug-01
No.:
RA265025a
Table 3
Model CodeDistributors Serial Number Note
For ConsumablesB310-00Ricoh1E000900001~September ’00 production
B310-01GesGE000900001~ September ’00 production
B310-02NashuaNE000900001~ September ’00 production
B310-03RexRE000800911~ ’00 Aug. 31~
B310-04SavinSE000900001~ September ’00 production
B310-05InfotecFE000800120~ ’00 Aug. 30~
B310-06LanierLE000800235~ ’00 Aug. 30~
For MachinesOE000802601~ ’00 Aug. 22~
Table 4
Model CodeDistributors Serial Number Note
For ConsumablesB403-00Ricoh5E110500423~May ’01 production
B403-01GesGE110500642~ May ’01 production
B403-02NashuaNE110600001~ June ’01 production
B403-03No BrandRE110500001~ May ’01 production
B403-04SavinSE110500001~ May ’01 production
B403-05InfotecFE110500001~ May ’01 production
B403-06LanierLE110500001~ May ’01 production
For Machines2E110501210~May ’01 production
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.