Rice Lake Weighing Systems is an ISO 9001 registered company. Software revision 11439
September 2014 Rev B
i
Technical training seminars are available through Rice Lake Weighing Systems.
Course descriptions and dates can be viewed at www.ricelake.com/training
or obtained by calling 715-234-9171 and asking for the training department.
iiRice Lake Digital Physician Scale Technical Manual
1.0Introduction
The Rice Lake Digital Physician Scale is efficiently designed to provide accurate, reliable and repeatable weight
measurements. The Rice Lake Digital Physician Scale comes equipped with a built-in height rod, a handle and
two heavy-duty rear wheels for easy portability.
This manual can be viewed and downloaded from the Rice Lake Weighing Systems web site at
www.ricelakehealth.com. Technical information on these products and other medical products are
available on the Rice Lake Weighing Systems website.
Figure 1-1. Rice Lake Digital Physician Scale (RL150-10-5)
1
Rice Lake Digital Physician Scale Technical Manual
2.0Safety
Important
Caution
Warning
Warning
With the Rice Lake Digital Physician Scale there are certain precautions that should be taken to prevent personal
injury to the user and damage to your scale.
2.1Safety Signals
Safety Signal Definitions:
Indicates a potentially hazardous situation that, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous s
moderate injury.
Indicates information about procedures that, if not observed, could result in damage to
equipment
.
ituation that, if not avoided, may result in minor or
2.2Safety Precautions
Do not operate or work on this equipment unless you have read and understand
instructions in the manual. Failure to follow the instructions
result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement
manuals. Proper care is your responsibility.
Before attempting to operate this unit, make sure every individual who operates or works
with this unit has read and understands the following safety
these instructions carefully.
•Do not drop the scale or subject it to violent shocks.
•For accurate weighing, the scale must be placed on a flat, stable surface.
•Do not transport the scale while someone is standing on it.
•Weight exceeding the maximum capacity (55
•Operating at voltages and frequencies other tha
•If the
LO Bat indicator activates, for accurate weighing, replace the batteries or connect the scale to an AC
0 lb/250 kg) may damage your scale.
n specified could damage the equipment.
power source as soon as possible.
•To avoid cross contamination, the sca
le should be cleaned regularly.
•Avoid contact with excessive moisture.
•Do not allow minors (children) or inexpe
rienced persons to operate this scale.
•Do not jump up and down on the scale.
•Do not place fingers into slots or possible pinch points.
•Do not use in the presence of flammable materials.
•These scales are used to determine weight of people while standing.
•Do not make alterations or modifications
to the scale.
•People with disabilities, or who are physically frail, should alwa
using this scale.
•Do not use the scale on slippery surfaces, such as a wet floor.
•Do not use this scale when your body/feet
are wet, such as after taking a bath.
or heed the warnings could
information. Please follow
ys be assisted by another person when
2Rice Lake Digital Physician Scale Technical Manual
3.0Scale Assembly
Important
Important
3.1Unpacking Your Scale
Place the unopened box in an open area that has ample room for unpacking the scale.
Parts contained in the shipping box include:
•The scale which includes the sc
•Operation manual
•CD containing USB driver
•Height rod
•White box labeled
•Wheels (2)
•Wheel hinge (1)
•Pan head screws (8)
•AA batteries (6)
All component parts have been wrapped in plastic. Remove the plas
Parts Inside which contains the following:
3.2Repacking
If the Rice Lake Digital Physician Scale must be returned for modification, calibration or repair, it must be
properly packed with sufficient packing materials. Whenever possible, use the original carton when shipping the
scale back.
Damage caused by improper packaging is not covered by the warranty.
ale base and attached column
tic and set aside.
3.3Setting Up Your Scale
Use the following steps to set up the Rice Lake Digital Physician Scale.
Tools needed for setup include:
•Phillips head screwdriver
Use the following steps to set up the scale.
Move the scale into the area where the w
the most accurate weighments.
1. Locate the operator’s manual from inside the box and set aside as it will provide inst
proper scale removal and set up.
2. Carefully lift the scale out of the packaging material; lift
The scale base and scale column are connected by cable and require great care when
removing from the box so that the cabling does not get damaged.
eighing process will occur. Place the scale on a hard, level surface for
it out by the scale base.
ructions on the
Figure 3-1. Cabling Connecting the Scale Platform and Scale Column
Rice Lake Digital Physician Scale — Scale Assembly3
3. Gently thread loose cabling through the top of the scale column to eliminate any excess cable at the
bottom of the column. This will eliminate the chance of pinching the cable as the column is being
connected to the scale base.
4. Attach the scale column to the base as shown in Figure 3-2 making sure not to pinch the cable.
Figure 3-2. Attaching the Scale Column to the Scale Base
5. Using the enclosed screws, attach the column to the scale base as shown in Figure 3-3.
Figure 3-3. Attach with Screws
4Rice Lake Digital Physician Scale Technical Manual
Wheel Assembly
Plug connector into
upper column.
Note
Make sure that screw
holes are lined up.
Attach the wheel assembly to the scale prior to connecting the second column. To attach the wheels, use the
following steps.
1. Attach the two wheels to the wheel ass
Figure 3-4. Attach Wheel Assembly
embly rod, as shown in Figure 3-4.
2. Attach the wheel assembly to the scale using a Phillips head screw and tighten with a screwdriver.
Attach Second Column to First Column
Once the wheel assembly is attached, finish the scale assembly using the following steps.
Ensure that the cable is extending through the top of the lower column so that it can be plugged into the
second (upper) column.
Figure 3-5. Extend Cable Through Scale Column
3. Once the cable is connected, insert and slide the upper column onto the lower column as shown in
Figure 3-6, making sure that the screw holes are lined up and that the cable does not get pinched.
4. Insert two screws and tighten using a Phillips head screwdriver.
Figure 3-6. Insert Upper Column into Lower Column
Rice Lake Digital Physician Scale — Scale Assembly5
Height Rod Installation
Use the following steps to install the height rod assembly.
1. The height rod comes in two pieces. Connect the two pieces together.
2. Slide the assembled height rod from the top of the column in the slot loca
ted on the front of the scale as
shown in Figure 3-7.
Figure 3-7. Height Rod Assembly
3. To use the height rod, pull up on the height rod using the plastic cap located at the top of the height rod as
shown in Figure 3-7.
4. Swing the height adjustment lever into
a horizontal position according to the person to be measured. The
person being measured needs to stand straight with the height adjustment lever just touching the top of
the person’s head.
Inserting Batteries
The six AA batteries that come with the scale offer an average of 25 hours of continuous use.
To install the batteries,
1. Open the battery chamber cover by loosening the thumb scre
w.
2. Insert batteries as shown in Figure 3-8.
Figure 3-8. Batteries in Battery Chamber
3. Close the battery chamber cover.
6Rice Lake Digital Physician Scale Technical Manual
AC Power Connections
Connect the
optional AC
power adapter.
RS-232
Connection explained in
Section 7.0.
Use the optional 120 VAC adapter or 230 VAC adapter when power is available. The optional AC power adapter
plugs into the back of the indicator as shown in Figure 3-9.
Figure 3-9. Power Connection
Leveling the Scale
Use level bubble to check for level and adjust feet as needed.
Figure 3-10. Bubble Indicates Scale is Level
On a flat surface, adjust scale feet until the bubble indicates that the scale is level.
Rice Lake Digital Physician Scale — Scale Assembly7
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.