Introduction
i
1.0Introduction
This manual is intended for use by service technicians responsible for installing and servicing the 882D Belt Scale Integrator.
Manuals are available from Rice Lake Weighing Systems at
www.ricelake.com/manuals
Warranty information is available at www.ricelake.com/warranties
1.1Overview
A belt conveyor scale continuously measures bulk material as it is moved along a conveyor. The system requires two general
parameters to operate:
• Weight of the material being moved along the conveyor belt
• Speed at which the material is moved along the conveyor belt
The weight of the material on the belt is determined by weighing a section of the conveyor belt loaded with material and
subtracting the average weight of the unloaded belt. The speed at which the material is moving is determined by measuring the
speed of an idler or wheel in contact with the conveyor belt. The weight and speed are combined by the 882D to give a running
total and a rate of flow for the material. Optimum operation of the scale system requires the components to be installed
correctly, periodically calibrated and properly maintained.
1.2Safety
Safety Definitions:
DANGER: Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. Includes
hazards that are exposed when guards are removed.
WARNING: Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Includes
hazards that are exposed when guards are removed.
CAUTION: Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury.
IMPORTANT: Indicates information about procedures that, if not observed, could result in damage to equipment or
corruption to and loss of data.
General Safety
Do not operate or work on this equipment unless this manual has been read and all instructions are understood.
Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake
Weighing Systems dealer for replacement manuals.
WARNING
Failure to heed could result in serious injury or death.
Some procedures described in this manual require work inside the enclosure. These procedures are to be performed by qualified
service personnel only.
Ensure the power cord is disconnected from the power source before opening the unit.
Do not allow minors (children) or inexperienced persons to operate this unit.
Do not operate without enclosure completely assembled.
Do not place fingers into slots or possible pinch points.
Do not use this product if any of the components are cracked.
Do not exceed the rated load limit of the unit.
Do not make alterations or modifications to the unit.
Do not use for any purpose other than as a belt scale integrator.
Do not remove or obscure warning labels.
Do not submerge.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Canada
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numériques de la Class A prescites dans le Règlement sur le brouillage radioélectrique edicté par le ministère des
Communications du Canada.
1.4Options
There are two option card slots, connectors J8 and J9, that can support Rice Lake option cards. Each option card kit includes
instructions for installing and set up.
1.4.1Available Option Cards
Single Analog Output – supports a single analog output
4-Channel Relay – supports 4 relay outputs
8-Channel Digital I/O (24V DC) – supports 8 digital inputs/outputs
24-Channel Digital I/O (TTL level) – supports 24 digital inputs/outputs
Fieldbus Carrier Board – only supported on slot 1 and supports the following modules:
• Ethernet/IP
• PROFINET
• DeviceNet
• PROFIBUS
• Modbus TCP/IP
• EtherCAT
NOTE: Refer to the Interface Option Cards Installation and Programming Manual (PN 190906) for Fieldbus command
specifications.
™
®
®
®
®
®
Option Card Power Limitations
Only two of the following can be used simultaneously due to power limitations:
• Single Analog Output option card
• 24-Channel Digital I/O option card
• Pulse encoder that draws > 50 mA
• 5V on the Digital I/O connector > 100 mA
10Visit our website www.RiceLake.com
Page 11
Installation
WARNING
AVERTISSEMENT
CAUTION
ATTENTION
9.93
8.10
.63
.68
8.94
6.50
4.14
4.31
4.00
6.25
1.06
2.50
.73
.27
1.93 4.50
.28
Top ViewBottom View
Front ViewBack ViewSide View
2.0Installation
This section describes procedures for connecting power, load cells, speed sensor, digital I/O and data communications cables
to the 882D. An assembly drawing and parts list are included for the service technician.
Risk of electrical shock.
Risque de choc.
Disconnect power before servicing.
Débranchez l’alimentation avant l’entretien.
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to state and
local regulations.
Risque d’explosion si la batterie est remplacée par un type incorrect. Mattre au rebus les batteries usagées
selon les règlements d'état et locaux.
• Use anti-static protection for grounding and to protect components from electrostatic discharge (ESD) when working inside the
882D enclosure.
• Procedures requiring work inside the 882D must be performed by qualified service personnel only.
• The power supply cord serves as the power disconnect for the 882D. The power receptacle to the 882Dmust be easily
accessible.
2.1Unpacking
Immediately after unpacking, visually inspect the 882D to ensure all components are included and undamaged. The 882D
enclosure comes assembled to the universal mount. The shipping carton should also contain the parts kit (Section 2.10 on
page 20) and the manuals. If any parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper
The 882D includes a universal mount. The universal mount can be mounted on a wall, tabletop or any flat surface.
NOTE:The universal mount comes attached to the 882D. Rice Lake Weighing Systems recommends removing the 882D
from the universal mount prior to mounting.
Figure 2-2. Mounting the 882D
1.Using the mount as a template, mark the screw locations.
2.Drill holes for the screws.
3.Secure the universal mount using the appropriate length 1/4'' or M6 hardware (not included).
4.Reattach the 882D to the universal mount.
2.3Backplate Removal
Remove the backplate of the 882D to connect cables for installed option cards and to gain access to the display board, CPU
board and power supply board.
WARNING: The 882D has no on/off switch. Before removing the backplate and opening the unit, ensure the power cord is
disconnected from the power receptacle.
1.Place the 882D face-down on an anti-static work mat.
2.Remove the M4 nuts holding the backplate to the enclosure with a 7 mm socket or wrench.
3.Lift the backplate away from the enclosure. Disconnect the ground wire from the backplate by removing the M4 nut
with a 7mm socket or wrench and set it aside.
Figure 2-3. Removing the Backplate
NOTE:882D ships with only four nuts securing the backplate. The remaining backplate nuts are included in the parts kit.
For reassembly torque backplate nuts to 15 in-lb (1.7 N-m).
12Visit our websitewww.RiceLake.com
Page 13
Installation
Silver
side out
Shield wire
Cut insulated jacket here
for foil shielded cables
Length of foil before
folding back on
cable insulation
2.4Cable Connections
The 882D has seven cord grips at the bottom of the enclosure, one is used for the power supply. The backplate must be
removed to make connections to the load cells, speed sensor, communications, digital inputs and digital outputs. Plugs must
remain in all unused cord grips to prevent moisture and dust from entering the enclosure. For recommended wire gauge and
cord grip specifications refer to Table 12-6 and Table 12-7 on page 97. Torque cord grip nuts to 33 in-lb (3.7 N-m).
IMPORTANT: Do not have open/bare wires outside of the enclosure. Make sure no stripped portion of cable is on the
outside of the cord grips.
WARNING: Power must be disconnected before servicing or installation. Failure to do so could result in electrical shock
and damage to the CPU board.
2.4.1Load Cells
To attach the cable from a load cell or junction box, route cable to the J1 connector (
cable is included in the parts kit. Wire the load cell cable from the load cell or junction box to connector as shown in
using a 6-wire load cell cable (with sense wires), remove jumpers JP5 and JP6(Figure 2-9 on page 18).
NOTE: For a 4-wire installation leave jumpers JP5 and JP6 in place and leave pins 3 and 4 empty on the connector.
ConnectorPinFunction
J11+SIG
2–SIG
3+SENSE
4–SENSE
5+EXC
6–EXC
For 6-wire load cell connections, remove
jumpers JP5 and JP6.
Table 2-1. J1 Pin Assignments
Figure 2-9 on page 18
). Connector for the
Table 2-1. If
2.4.2Cable Shield Grounding
Except for the power cord, all cables routed through the cord grips must be shield grounded against the enclosure.
Foil Shielded Cable
• Use hardware provided in the parts kit to install shielding clamps on the grounding studs at the bottom of the enclosure
• Install only the necessary amount of shielding clamps for the cord grips to be used; finger tighten nuts at this time
• Route cables through the cord grips and shielding clamps to determine the cable lengths required to reach the
appropriate cable connectors
• Mark the cables to remove the insulated jackets and shielding as described in the next two sections
Figure 2-4. Foil Shielded Cable
1.Strip the insulated jacket and foil 1/2'' (15 mm) past the shielding clamp.
2.Strip another 1/2'' of the insulated jacket, leaving the foil shielding exposed.
3.Fold the foil shielding back on the cable where the cable passes through the clamp.
4.Ensure the silver (conductive) side of the foil is turned outward.
5.Wrap the shield wire around the cable so it contacts the foil where the cable passes through the clamp.
6.Torque the shielding clamp nut to 10 in-lb (1.13 N-m) so the clamp is around the cable and contacting the shield wire.
1.Strip the insulated jacket and braided shielding from a point just past the shielding clamp.
2.Strip another 1/2'' (15 mm) of the insulated jacket, leaving the braid exposed where the cable passes through the clamp.
3.Tighten the shielding clamp nut.
2.4.3Power Cable Grounding
AC versions of the 882D are shipped with the AC power cable already installed and grounded to the enclosure. For DC
versions of the 882D, use the following steps to ground and connect the DC power cable.
1.Run DC power cable (not included) up through the cord grip (Figure 2-6).
NOTE: For the recommended wire gauge refer to Table 12-6 on page 97.
2.One wire will be terminated (grounded) at a stud near the cord grip using the proper grounding stack. The backplate
ground is already attached to a stud. Remove it so that the power cord ground can be on the bottom of the stack as
represented in Figure 2-6. Torque nuts to 10 in-lb (1.13 N-m).
3.Run the other two wires toward the back of the enclosure and connect them to the three pin plug (included in the parts
bag) that connects into the power supply board as shown in Figure 2-6 and Table 2-2.
A ferrite from the parts kit must be applied to
the DC power cable within 1'' of the cord grip.
Power
Supply
Power Cord Ground
Figure 2-6. Connect DC Wiring
PinACDC
1N+
2Chassis
GND
3L–
Table 2-2. Power Connection Pin Assignments
M4 Nut
Chassis
GND
Backplate
Ground
Lock
Washer
Grounding
Stud
14Visit our website www.RiceLake.com
Page 15
2.4.4Power Cables
AC versions of the 882D are shipped with the AC power cable already installed.
Figure 2-7. AC Power Cable
NOTE: The AC power cable is grounded to the threaded grounding hole on the back panel of the enclosure between the
cord grip and the power supply connections rather than using Pin 3. This is a UL requirement.
PinDescriptionWire ColorCable Part No.
1120 VAC (Line In)Brown or Black180842
2AC NeutralBlue or White
3GroundN/C or Green/Yellow–
4DC Out (-V)Black199514
5DC Out (+V)Red
Table 2-3. AC Power Supply Pin Assignments
NOTE: Colors may vary depending on manufacturer of AC power cable. Utilize testing procedures to ensure proper
installation.
Installation
2.4.5Speed Sensor
A belt conveyor scale must be equipped with an encoder (speed sensor) that accurately senses the belt speed and travel
distance when the belt is empty or loaded. The J13 connector provides the pulse input from the speed sensor to the 882D. To
attach the cable from the encoder, route the cable to the J13 connector (Figure 2-9 on page 18). The connector for the cable is
included in the parts kit. Wire the cable to connector as shown in Figure 2-4. Pins 4, 5 and 6 are the top level of the connector
and make up the primary pulse input channel (Input 1). Pins 1, 2 and 3 are the bottom level of the connector and make up the
secondary pulse input channel (Input 2).
ConnectorPinSignal
J131+12V, 100 mA max
2Ground
3Pulse Input #2
4+12V, 100 mA max
5Ground
6Pulse Input #1
The Digital I/O Port, J2 connector (Figure 2-9 on page 18) is intended to be connected to both digital inputs and outputs.
Digital inputs can be set to provide many functions, including most keypad functions except MENU. Digital inputs are active low
(0 VDC) and inactive high (5 VDC). Use the Digital I/O menu to configure the digital inputs.
Digital outputs are used to control relays that drive other equipment. Outputs are designed to sink, rather than source, switching
current. Each output is an open collector circuit, capable of sinking 20 mA when active. Digital outputs are active when low or at
0 VDC, with reference to the 5 VDC supply.
Use the Digital I/O menu to set the function of the Digital I/O pins to OUTPUT and then use the Setpoints menu to configure the
digital outputs. Table 2-5 shows the pin assignments for the J2 connector.
ConnectorPinSignal
J215VDC, 500 mA max
2GND
3DIO1
4DIO2
5DIO3
6DIO4
Table 2-5. J2 Pin Assignments (Digital I/O)
2.4.7Serial Communications – Port 1 (COM)
The J3 connector (Figure 2-9 on page 18) is intended to provide a connection point for the RS-232 or the two-wire
RS-485/RS-422 serial communications. Table 2-6 shows the pin assignments for the J3 connector.
PinRS-232RS-485/RS-422
1GNDGND
2RXB
3TXA
Table 2-6. J3 Pin Assignments (Port 1 Serial Communications)
NOTE: For RS-232, all four switches on SW3 (Figure 2-9 on page 18) must be in the OFF position.
For RS-485/RS-422, all four switches on SW3 must be in the ON position.
2.4.8USB Device Communications – Port 2 (USBCOM)
The USB Device Port, J4 micro USB connector (Figure 2-9 on page 18), is intended to be connected to a PC only. It appears as
a Virtual COM Port and is assigned a “COMx” designation. Applications communicate through the port like a standard RS-232
communications port.
A ferrite from the parts kit must be applied to the USB cable within 1'' of the cord grip.
The cable must be sent through the ferrite twice.
The driver must be installed on the PC before the USB Device Port can be used. With the PC and 882D powered on, connect a
USB cable from the PC to the micro USB connector (J4) on the 882D. The PC will recognize that a device has been connected,
and attempt to install the driver needed to make it work. The driver can also be downloaded from the Rice Lake website.
NOTE: If using Windows 7 or later and the PC is connected to the Internet, the operating system may be able to install the
drivers without any interaction.
When the individual drivers are installed, a new COM Port designation is assigned for each physical USB port the 882D is
connected to on the PC.
16Visit our website www.RiceLake.com
Page 17
Installation
For example, if the PC has two physical RS-232 COM Ports, they most likely are designated COM1 and COM2. When
connecting the 882D to a USB port on the PC, it is assigned the next available port designation, or in this case, COM3. When
plugging into the same physical USB port on the PC, the port designation is again COM3. If plugging into another physical USB
port on the PC, it is assigned the next available designation, in this case COM4.
After the drivers are installed, use Windows Device Manager to determine the COM Port designation that was assigned to the
®
USB port. Or open the application that is to be used with the 882D, such as Revolution
, to see which ports are available.
Configuration of the USB Device Port is done in the USBCOM sub-menu under PORTS in configuration mode.
The port can be configured as either a demand port for EDP commands and printing, or as a data streaming port. Other settings
include the termination character(s), echoes, responses, the end-of-line delay and whether or not the 882D displays a 'print'
message when a print format sends data out the port.
NOTE: If a computer application has an open communications connection through the USB Device Port and the physical
cable connection is interrupted, a soft reset must be performed on the 882D or the power must be cycled to the 882D; the
connection in the computer application must be disconnected and then reconnected before it will continue to communicate
with the 882D.
For the USB Device Port, it does not matter what the settings are for Baud, Data Bits, Parity and Stop Bits in the computer
software. The port communicates in the same way regardless of these settings.
This port is not a host port and is not intended to be connected to other devices such as keyboards, memory sticks or
printers.
2.5USB Host
The 882D will be capable of hosting a USB device through the J5, Type A USB connection, in a future release.
2.6Ethernet Communications
The 882D features Ethernet TCP/IP 10Base-T/100Base-TX communication using a standard RJ45 connector, J6 (Figure 2-9
on page 18). It can support two simultaneous connections, one as a server, the other as a client.
Through an Ethernet network, software applications can communicate with the 882D using the EDP command set (Section 7.0
on page 57), or data can be streamed continuously from the 882D, or printed on demand.
The Ethernet port supports both DHCP and manual configuration of settings such as the IP and netmask. In addition, the TCP
Port number, Primary and Secondary DNS, and the Default Gateway can be configured using the Ethernet sub-menu of the
Ports setup menu. For more information on configuring the Ethernet port see Section 4.6.3.2 on page 38.
Physical connection to the 882D Ethernet port can be made directly from a PC to the 882D (AdHoc Network), or through a
network router or switch. The port supports auto-sensing MDI/MDIX cable configuration, so either straight-through or crossover
cables can be used.
The RJ45 Ethernet jack on the 882D CPU board houses two LEDs to
indicate the status and speed of the connection.
Yellow LED (left) indicates the status of the connection:
• Off for no link
• On for a link
• Blinking if there is activity
Green LED (right) is:
• Off for a 10Base-T connection
• On for a 100Base-TX connection
Yellow LED
Figure 2-8. RJ45 Ethernet Jack
Green LED
IMPORTANT: The Ethernet port is not intended for use on Telecom Networks Circuits that are subject to lightning or power
faults. For information on using the Ethernet port see Section 9.1 on page 80.
The COMM 1 port supports RS-232 or two-wire RS-485/RS-422 communications; selectable with switch SW3. The port is
configured using the COM menu under Ports. See Section 4.6.3.1 on page 37.
• USB Micro Device (J4)
• USB Host (J5)
• Ethernet TCP/IP (J6)
• Power Board (J7)
• OPT#1 (J8) and OPT#2 (J9)
• Pulse Input (J13)
2.8Audit Trail
The 882D supports a Type 3 Audit Trail. The Audit Trail records all of the changes to Legal for Trade parameters.
During installation, determine if access will be allowed to the configuration and calibration functions through the front panel. The
position of the 3-pin Audit Trail jumper (JP4) on the CPU board controls if access is allowed or not.
• If the jumper is set to ON, the Setup Menu will be visible, making calibration and configuration accessible through the
front keypad.
• If set to OFF, the Setup Menu will not be visible, making calibration and configuration accessible only by pressing the
setup switch.
The audit trail event logger operates in either position of the audit jumper.
18Visit our website www.RiceLake.com
Page 19
Installation
12
8
6
5
7
3
4
2.9Backplate Attachment
Once cabling is complete, reattach the backplate ground wire to the backplate. Position the backplate over the enclosure and
install the eight backplate nuts. Use the torque pattern shown in Figure 2-10 to prevent distorting the backplate gasket.
Torque nuts to 15 in-lb (1.7 N-m).
Figure 2-10. Torque Pattern
2.9.1Sealing
In certain applications, it may be necessary to seal the 882D to restrict access from the setup switch.
882D Sealing
1.Remove the lower left and lower center nuts securing the backplate. Replace with two drilled hex standoffs found in
the parts kit.
2.Place the sealing wire through the drilled hex standoffs on the backplate, then through the fillister head screw at the
175214Overlay, 882D Membrane Switch with Numeric Keys
3
30375Seal Ring, PG9 Nylon
4
15626Cord Grip, PG9 Plastic
5
15627Lock Nut, PG9 Plastic
6
19538Post, Slotted Black Seal 1/4 x 1, Cord Grip - Post Only
7
68599Seal Ring, PG-11
8
68600Cord Grip, PG11
9
68601Nut, PG11 Black Nylon
10
195688Display Board Replacement
11
180821Standoff, M3 x 0.5 x 5 mm Hex Male-Fem SS
12
177306Adapter Plate, Power Supply 882D
13
199474Screw, M3 x 0.5 x 5 mm SEMS Phillips Head Zinc Finish Steel External Tooth Washer
175603Board Assy, 880/882 Power Supply 115-230 VAC 5.5 Inch Blue Color (AC & EURO Only)
14
175604Board Assy, 880/882 Power Supply 9-36 VDC 5.5 Inch Blue Color (DC Only)
15
180822Standoff, M3 x 0.5 x 31 mm Hex Male-Fem SS
16
180823Standoff, M3 x 0.5 x 40 mm Hex Fem-Fem SS
18
154762Cable Assy, 10 Pos CPU to Power Supply 880 Controller
The front panel consists of a large back-lit LCD display, six primary scale functions keys, numeric keys and four function keys.
Figure 3-1. 882D Front Panel
Item No.Description
1F4 key – does not have a pre-defined use but can be monitored by an iRite application
2F3 key – does not have a pre-defined use but can be monitored by an iRite application
3F2/Stop key – used for batching and calibration
4F1/Start key – used for batching and calibration
5Load – displays when arrow annunciator is illuminated
6Total – displays when arrow annunciator is illuminated
7Rate – displays when arrow annunciator is illuminated
8Speed – displays when arrow annunciator is illuminated
9Totalizer 1-2 – the corresponding totalizer displays when the 1 or 2 annunciator is illuminated; the master totalizer displays when neither the
1 or 2 annunciator is illuminated
10Units – metric units: metric tons, kilograms, meters; imperial units: short tons, pounds, feet; time units: hours, minutes, seconds
11Center-of-Zero – displays when the Rate is within the Zero Band; the Zero Band is defined as a percentage of the Max Capacity (Max Rate)
and is configurable in the configuration settings
12Numeric display – seven digit display using 7-segment digits, a dash, a period (dot) and comma
13Numeric keys – 0-9, used to enter a numeric value for a parameter or prompt
14Decimal point key – inserts a decimal point
15
Clear key – resets totalizer 1 or 2 when displayed in weigh mode; deletes the currently selected character when editing a parameter or prompt
16Menu key – accesses/exits the menu structure; also functions as a “cancel” key when editing a parameter value
17Mode key – switches the weigh mode numeric display area between load, totalizer 1, totalizer 2, totalizer master, rate and speed; also used
as the down key to navigate menus or to edit a value
18Enter key – accepts entry at a prompt or when editing value
19Print key – sends print data to a communications port when in weigh mode; also used as the right key to navigate menus or to edit a value
20Zero key – places 882D into dynamic zero calibration when in weigh mode; also used as the up key to navigate menus or to edit a value
21Setpoint key – navigates to top level setpoint menu at first defined setpoint; also used as the left key to navigate menus or to edit a value
22Messaging area – 121 x 24 dot-matrix display, has three lines of text with up to 20 characters per line
Table 3-1. Front Panel Keys and Annunciator Descriptions
The three modes of operation for the 882D are described in the following sections.
Weigh Mode
In this mode, the 882D displays weight per conveyor belt distance, the amount of weight totalized, material flow rate, conveyor
belt speed and annunciators to indicate status.
Setup Mode
Most of the procedures described in this manual, including configuration and calibration, require the 882D to be in setup mode.
To enter setup mode, remove the fillister head screw from the bottom of the enclosure. Insert a non-conductive tool into the
access hole and press the setup switch once, allowing access to the Scale menu (Section 4.0 on page 27).
The 882D also has an Audit Trail that can track changes to configuration and calibration, allowing the setup switch to be
bypassed with Jumper J4 on the CPU board. If Audit Trail is enabled, configuration mode can then be accessed through the
user setup mode.
User Mode
User mode (accessed by pressing the Menu key) is used to:
• View/print the audit trail
• Enter setup mode (if audit trail is enabled)
• Clear the master totalizer
• Set the time and date
• View the current pulse input rate
3.2Weigh Mode Selection
Press to switch the numeric display area between load, totalizer 1, totalizer 2, master totalizer, rate and speed.
Load, totalizer, rate and speed values are up to 7 digits in length. Depending on the value and which units are configured
(METRIC or IMPERIAL), the units identifier will be lb, kg, tn, t, ft/min, lb/ft, m/s, kg/m.
Load – the amount of material present on a section of the belt, e.g. pounds per foot
Totalizer 1 & 2 – totalizers that hold accumulated value of material that has passed over the weigh frame since their last reset
Master Totalizer – is the accumulated value of material that has passed over the weigh frame since its last reset
Rate – the rate of flow of material, e.g. tons per hour
Speed – the speed at which the belt is moving, e.g. feet per second; the belt speed is the actual measured value using a speed
sensor or it can be a fixed value configured manually in the configuration settings
24Visit our website www.RiceLake.com
Page 25
3.3Audit Trail Information
MENU
MODE
PRINT
MODE
PRINT
ENTER
ENTER
MENU
882D
TOTALLOADRATESPEED
F1
START
F3
F2
STOP
a
b
MODE
ENTER
The audit trail report can be printed to a specified port through the Audit menu.
1.Press . Audit is displayed.
2.Press . LRV is displayed.
3.Press . Audit Print Port is displayed.
4.Press . The current Audit Print Port selection is displayed.
Operation
5.Press to scroll through port options to transmit the audit report. See
Table 4-2 on page 29
for available options.
6.Press to make selection. Print Audit Trail is displayed.
7.Press to print the Audit Trail report to the port specified.
8.Press to return to the weigh mode.
3.4Totalizers
The 882D maintains three totalizers:
• Totalizer 1
• Totalizer 2
• Master totalizer
NOTE: When a totalizer is displayed there is an arrow pointing to TOTAL (a) on the overlay with a number annunciator (b) in
the upper right hand side of the display. There is no number annunciator for the master total.
Figure 3-2. Totalizer Annunciators
3.4.1Totalizer 1 and 2
Two totalizers are provided so that different scenarios can be tracked.
Example: one could be a shift total and the other could be a daily total.
Clearing Totalizer 1 and 2
To clear totalizer 1 or 2 with the front panel, it must first be displayed in the weigh mode.
1.Press repeatedly until the desired totalizer is shown.
2.Press . Press Enter To Clear is displayed.
3.Press clears the totalizer. CLEAR briefly displays.
NOTE: Press any other key to cancel.
EDP commands RT1 and RT2 immediately clear the respective totalizer. See Section 7.2 on page 60.
Triggering a CLRTOT1 or CLRTOT2 digital input immediately clears the respective totalizer. See Section 4.6.6 on page 42.
The master totalizer is a total of all the material that has gone across the scale.
Master Totalizer Reset
The Master Total can be cleared through the Test menu. The ability to reset the master totalizer can be limited by a password
protecting the User menu. See Section 4.6.2.2 on page 36.
1.Press . Audit is displayed.
2.Press twice. Test is displayed.
3.Press . Pulse Input is displayed.
4.Press . Master Total Reset is displayed.
5.Press . NO is displayed.
6.Press . YES is displayed.
7.Press . RESET briefly displays.
8.Press to return to the weigh mode.
NOTE: The 882D clears all of the totalizers at power up if the non-volatile memory appears to be corrupt.
26Visit our websitewww.RiceLake.com
Page 27
Configuration
MENU
MENU
MENU
PRINT
MODE
MODE
MODE
PRINT
MENU
4.0Configuration
Several parameters can be accessed and set by pressing .
NOTE: All weight related parameters must be configured prior to calibrating the unit.
4.1Setup Switch Configuration Access
In order to configure the 882D, it must be placed in configuration mode with the setup switch or accessed through the User menu
(
Section 4.2
the access hole to press the setup switch.
). The setup switch is accessed through a small hole on the bottom of the enclosure. Insert a non-conductive tool into
IMPORTANT: Use caution when inserting the non-conductive tool into the enclosure. Insert the tool about 3/4 inch, until the
switch is engaged. Do not use excessive force which could damage the switch.
Setup Switch Access
.
Figure 4-1. Setup Switch Access
When the 882D is placed in configuration mode, the Setup menu is accessed andScale displays. See Section 4.6 on page 29
for a detailed description of this menu. Torque the setup switch screw to 15 in-lb (1.7 N-m) when reinserting.
4.2User Menu Configuration Access
The 882D supports an Audit Trail jumper. If the jumper is set to ON, the Setup Menu is visible, making calibration and
configuration accessible through the front keypad. If set to OFF, the Setup Menu is not visible, making calibration and
configuration accessible only by pressing the setup switch.
If the audit trail jumper (JP4) is set to ON, configuration mode may be accessed by pressing .
1.Press . Audit is displayed.
2.Press . Setup is displayed.
3.Press . Scale is displayed. See Section 4.6.1 on page 30 for the breakdown of the Scale menu.
4.Press . Configuration is displayed.
― Press again to access the Configuration parameters.
― Or press to move to the Calibration menu.
When configuration is complete, press to return to the weigh mode.
AuditDisplays the legally relevant (LR) firmware version, and allows access to view/print audit trail information; See Section 4.5
SetupUsed to enter setup mode if audit trail is enabled; See Section 4.6
TestView the pulse input, reset the master total; See Section 4.7 on page 45
Time & DateView and change time and date; See Section 4.8 on page 45
Table 4-1. User Menu Parameters
4.5Audit Menu
Figure 4-3. Audit Menu
Configuration
LRVLegally relevant firmware version
Audit Print PortSets the port that an audit report is transmitted on; Settings:
Print Audit TrailOutput print to the port specified by the Audit Print Port parameter
4.6Setup Menu
MenuDescription
ScaleSet configuration and calibration of the scale; See Figure 4-5 on page 30
FeaturesSet miscellaneous system attributes; See Figure 4-11 on page 35
PortsConfigure communication ports; See Figure 4-14 on page 37
Print FormatsSet print format 1-4 to be used; See Figure 4-17 on page 39
SetpointsConfigure setpoints and batching mode; See Figure 4-18 on page 40
Digital I/OAssign digital input/output functions; See Figure 4-19 on page 42
Analog OutConfigure the analog output module (if installed); See Figure 4-20 on page 43
VersionView the installed firmware version number or reset to factory settings; See Figure 4-21 on page 44
ParameterDescription
COM (default) – RS-232 and RS-485 Communications Port
USBCOM – USB Device Port
ETH-S – Ethernet Server Port
ETH-C – Ethernet Client Port
OFF – No printing port selected
ConfigurationFor Configuration menu see Figure 4-6 on page 31
CalibrationFor Calibration menu see Figure 4-7 on page 32
FormatFor Format menu see Figure 4-8 on page 33
Auto Zero Track Band Automatically zeros scale when within range specified, if Rate is within the Zero Range; Specify zero tracking band as a
percentage of Max Capacity (Rate); maximum legal value depends on local regulations; Enter value: 0.0-100.0, 0.0 (default)
Auto Zero Track MaxThis is the maximum amount as a percentage of Max Capacity (Rate) that can be auto zeroed;
Enter value: 0.0-100.0, 0.0 (default)
Zero BandThis is the range that is used to determine whether the weight is zero; Zero band represents a percentage of Max Capacity
(Rate); When weight is within the zero band, the center of zero annunciator will be displayed; Maximum legal value depends on
local regulations; Enter value: 0.0-100.0, 0.0 (default)
Zero RangeThis is the total amount that can be zeroed off - either manually or summed with Auto Zero; Zero range represents a percentage
of Max Capacity (Rate); A value of 0.0 prevents any zeroing; Maximum legal value depends on local regulations;
Enter value: 0.0-100.0, 0.0 (default)
Example: A value of 1.9 represents ±1.9% around the calibrated zero point, for a total range of 3.8%
Confirm ZeroPrompts to confirm a zero operation. Applies to front panel zero key or digital input; Settings: ON (default), OFF
Dead Band882D does not totalize the amount if the rate is within the dead band value; The flow rate is set to zero within the dead band;
Dead band represents a percentage of Max Capacity (Rate); Enter value: 0.0-100.0, 0.0 (default)
Display RateSpecifies the display update rate, number of 100-millisecond intervals between updates; Enter value: 1-80, 1 Hz (default)
Sample RateSelects measurement rate, in samples per second, of the analog-to-digital converter;
A/D FilterFor A/D Filter menu see Figure 4-9 on page 34
WarmupThe warmup timeout is started once speed is detected at power up; If speed drops to 0 or 882D enters setup mode, the warmup
timer stops; The warmup timer will restart once speed is above 0 and 882D is in weigh mode; The parameter for warmup
represents minutes, a setting of 0.0 will disable warmup; Enter value: 0.0-60.0, 0.0 (default)
If the Rate or Load is being displayed while warmup is active:
Message area will show “Warm Up”
No annunciators will be displayed
Dashes will fill numeric area
Modes other than Rate or Load will display normally while warmup is active.
Rate DampeningFor Rate Dampening menu see Figure 4-10 on page 34
Negative TotalizingSpecifies whether to allow values to be totalized when load value is negative, causing value to be subtracted from totalizers;
Settings: YES (default), NO
Table 4-4. Setup – Scale Menu Parameters
NOTE: The 882D goes directly to the Scale menu when the setup switch is pressed (Section 4.1 on page 27).
30Visit our website www.RiceLake.com
Page 31
4.6.1.1 Scale – Configuration Menu
Scale
Configuration
Weigh Frame
Total Loadcell
Build
Millivolt OutputRatioIdler Spacing
Number of
Idlers
Conveyor
Belt Length
Angle of
Incline
Test Distance
Speed Sensing
Fixed Speed
Distance per
Pulse
Pulse Input
Figure 4-6. Scale – Configuration Menu
ParameterSettingDescription
Speed Sensing--Settings related to the belt speed sensor
Pulse InputSpecifies the pulse input scheme used for speed determination and error detections; Settings:
SINGLE (default) – a single sensor going only to pulse input #1
DUAL – Two sensors each going to an individual pulse input
REDUNDANT – a single sensor going to both of the pulse inputs
Fixed Speed
Distance per PulseDistance represented by each pulse from a speed sensor (ft, m); Enter value: 0.0-99.0, 1.0 (default)
Weigh Frame--Settings related to the weigh frame
Total Loadcell BuildDefines the total capacity of the all load cells in system (lb, kg); Enter value: 1.0-99999.0, 500.0 (default)
Millivolt OutputAverage mv/v rating of all load cells in the system; This is used for the theoretical calibration; Value must be
RatioThe lever ratio for a pivoted weigh frame; The total loadcell build is multiplied by the configured ratio to
Idler SpacingSpacing between the idlers used to determine weighing surface of belt scale (in, m);
Number of IdlersNumber of idlers being used; Enter value: 1-4, 1 (default)
Conveyor--Settings related to the conveyor being used
Belt LengthThe total length of the conveyor belt (ft, m); Enter value: 1.0-99999.0, 500.0 (default)
Angle of InclineThe angle of the conveyor measured in degrees; used when 882D is used with weigh frames containing one
Specifies a fixed belt speed for the 882D (ft/min, m/s); If a non-zero value is entered the 882D will no longer
calculate belt speed using the speed sensor; When using fixed speed there must also be a digital I/O configured
and enabled as BELTRUNNING or the speed will be forced to 0; Enter value: 0.0-9999.0, 0.0 (default)
Example: if there are eight load cells and each has a rated capacity of 100, multiply 100 by 8;
800 would be the total capacity
greater than 0; Enter value: 0.1-4.5, 3.0 (default)
determine a working total loadcell build value; Enter value: 0.0-9.999, 1.0 (default)
Enter value: 0.01-9999.0, 48.0 (default)
or two load cells; Enter value: 0.0-89.0, 0.0 (default)
Belt speed is calculated from known parameters of the speed sensor; see Section 5.1.1 on page 46; Sub-parameters:
Pulse Per Revolution – Number of pulses output from the speed sensor per speed sensor revolution
Sensor Diameter – The diameter of the speed sensor (in/mm)
Calibrate – Initiates a calculated speed calibration
Belt speed is determined by measuring the number of complete revolutions; see Section 5.1.2 on page 47; Sub-parameters:
Test Revolutions – User provided number of revolutions that the belt made during a speed calibration
Calibrate – Initiates a revolutions speed calibration
Belt speed is determined by measuring the speed sensor output over a set distance; seeSection 5.1.3 on page 49; Sub-parameters:
Test Distance – User provided distance that the belt travels during a speed calibration (ft/m)
Calibrate – Initiates a distance speed calibration
Table 4-6. Scale – Calibration – Speed Sensor Menu Parameters
Weigh Frame Parameters
ParameterDescription
Static ZeroA dead load calibration with the belt not moving; see Section 5.2.1 on page 50
Dynamic
Span
Dynamic
Zero
Linearization
Point 1-5
32Visit our website www.RiceLake.com
There are three dynamic span calibration options; see Section 5.2.2 on page 50; Options:
Test Weight – Span calibration based on belt length defined by number of revolutions and static test weight;
see Section 5.2.2.1 on page 50; Sub-parameters:
Test Weight Value – The amount of test weight used
Calibrate – Initiates a test weight span calibration
Chain – Span calibration based on belt length defined by number of revolutions and static chain weight;
see Section 5.2.2.1 on page 50; Sub-parameters:
Chain Weight – The weight/length of a chain used (ex. A chain weight value of 100 equals 100 kg/meter, if in metric)
Calibrate – Initiates a chain span calibration
Material – Span calibration based on a known amount of material; Section 5.2.2.2 on page 51; Sub-parameters:
Material Weight – The known weight amount of the material
Calibrate – Initiates a material span calibration
A dead load calibration with the belt moving; see Section 5.2.3 on page 52; Sub-parameters:
Zero Counts – Raw count value zero (deadload); can be set manually or through calibration
Calibrate – Initiates a dynamic zero calibration
Allows up to five correction Factor ranges to be configured as a percent of Max Capacity; Section 5.2.4 on page 53; Sub-parameters:
Percent Capacity 1-5 – Percentage of Max Capacity; for which the correction Factor for this linear point will be applied;
Enter value: 0.0-100.0, 0.0 (default)
Correction Factor 1-5 – Correction Factor for the corresponding linear point; Enter value: 0.0-1000.0, 100.0 (default)
Table 4-7. Scale – Calibration – Weigh Frame Menu Parameters
Page 33
4.6.1.3 Scale – Format Menu
Scale
Format
Max Capacity
number
Units
METRIC
Totalizer
Resolution
Rate
Resolution
Amount
Per Pulse
Total Pulse
Pulse Width
number
Load
Resolution
IMPERIAL
IMPERIAL
0.2 LB
0.1 LB
0.5 LB
1 LB
2 LB
5 LB
0.01 TN
0.02 TN
0.05 TN
0.1 TN
0.2 TN
0.5 TN
1 TN
2 TN
5 TN
0.2 KG
0.1 KG
METRIC
0.5 KG
1 KG
2 KG
5 KG
0.01 T
0.02 T
0.05 T
0.1 T
0.2 T
0.5 T
1 T
2 T
5 T
0.01 T/H
1 KG/H
0.1 T/H
1 T/H
METRIC
0.01 TN/H
1 LB/H
0.1 TN/H
1 TN/H
IMPERIAL
0.2 LB
0.1 LB
0.5 LB
1 LB
2 LB
5 LB
0.01 TN
0.02 TN
0.05 TN
0.1 TN
0.2 TN
0.5 TN
1 TN
2 TN
5 TN
IMPERIAL
0.2 KG
0.1 KG
0.5 KG
1 KG
2 KG
5 KG
0.01 T
0.02 T
0.05 T
0.1 T
0.2 T
0.5 T
1 T
2 T
5 T
METRIC
0.02 KG/M
0.01 KG/M
0.05 KG/M
0.1 KG/M
0.2 KG/M
0.5 KG/M
1 KG/M
2 KG/M
5 KG/M
METRICIMPERIAL
0.02 LB/FT
0.01 LB/FT
0.05 LB/FT
0.1 LB/FT
0.2 LB/FT
0.5 LB/FT
1 LB/FT
2 LB/FT
5 LB/FT
Configuration
ParameterDescription
Max capacityMaximum rated capacity (maximum weight) that can pass along the belt scale per hour;
UnitsSelect unit of measure to be used in the weigh mode; Settings: METRIC, IMPERIAL
Load ResolutionResolution for the load value; Select value: See Figure 4-8
Totalizer ResolutionResolution for the totalizer value; Select value: See Figure 4-8
Rate ResolutionResolution for the rate value; Select value: See Figure 4-8
Total Pulse – Amount Per Pulse Defines the change in total that will activate the Total Pulse digital output (if configured);
Total Pulse – Pulse WidthDefines how long the tons per pulse output stays on, in milliseconds;
Figure 4-8. Scale – Format Menu
Enter value: 1.0-9999999.0, 500.0 (default)
Example: If 1 TN is set, for every 1 TN change in the total, the Digital Output will be activated for a
time defined by the Pulse Width parameter; Select value: See Figure 4-8
Digital Filter 1Digital Filter 2Digital Filter 3Filter SensitivityFilter ThresholdRattleTrap
Scale
SecondsSensitivityThreshold
Rate
Dampening
4.6.1.4 Scale – A/D Filter Menu
ParameterDescription
Digital Filter 1-3Select the digital filtering rate used to reduce the effects of mechanical vibration from the
Filter SensitivitySelect the number of consecutive readings that must fall outside the Filter Threshold parameter
Filter ThresholdSelect the Filter Threshold, in display divisions; when a specified number of consecutive scale
RattleTrapEffective at filtering repeating vibrations caused by mechanical noise from nearby machines, but
Figure 4-9. Scale – A/D Filter Menu
immediate area of the scale; selected setting indicates the number of A/D conversions per update
that are averaged to obtain the displayed reading; a higher number gives a more accurate display
by minimizing the effect of a noisy reading, but slows down the settling rate of the indicator;
before digital filtering is suspended; Select value: 2OUT (default), 4OUT, 8OUT, 16OUT,
32OUT, 64OUT, 128OUT
readings (Filter Sensitivity parameter) fall outside of the threshold, digital filtering is suspended;
the filter is always enabled if NONE is selected; Select value: NONE (default), 2D, 5D, 10D,
100D, 200D, 250D
may increase settling times over standard digital filter selections; Select value: OFF (default),
ON - enables RattleTrap
®
Table 4-9. Scale – A/D Filter Menu Parameters
4.6.1.5 Scale – Rate Dampening Menu
ParameterDescription
SecondsThe number of seconds to average rate values; the damped rate value is what is shown on the
weigh mode display and what is used for the analog output; a value of 0 turns off averaging;
Enter value: 0-600, 0 (default)
SensitivityThe rate dampening sensitivity specifies the number of consecutive rate value calculations that
must fall outside the rate dampening threshold before digital filtering is suspended; it is also the
number of consecutive rate value calculations that must fall inside the rate dampening threshold
before digital filtering is resumed; Enter value: 0-400, 50 (default)
ThresholdThe rate dampening threshold sets a value, in pounds, kilograms, tons or metric tons; the specific
unit is dependent on the Units parameter and the Rate Resolution parameter; when a specified
number of consecutive rate value calculations fall outside of this threshold, digital filtering is
suspended; a value of 0 turns off the filter override; Enter value: 0-1000, 200 (default)
Table 4-10. Scale – Rate Dampening Menu Parameters
Figure 4-10. Scale – Rate Dampening Menu
34Visit our websitewww.RiceLake.com
Page 35
Configuration
Features
Setup
RegionUnit ID
Consecutive
Number
PasswordKey Locks
CLR TOTAL 1
W/PRINT
CLR TOTAL 2
W/PRINT
Features
Region
Time FormatSet
Decimal
Format
TimeDate
Time
Separator
Date FormatSet
Date
Separator
4.6.2Setup – Features Menu
Figure 4-11. Setup – Features Menu
ParameterDescription
RegionSee Section 4.6.2.1 for parameters
Unit IDSpecifies the unit identification string; Settings: Enter string 1-16 characters, 1 (default)
Consecutive
Number
PasswordUser – Protect items in the top level menu; If the value is zero the password is turned off; Enter value: 0-999999, 0 (default)
Key LocksSee Section 4.6.2.4 on page 36 for keys that can be locked
CLR Total 1 w/PrintThe Totalizer 1 value is cleared when a print is performed; Settings: No (default), Yes
CLR Total 2 w/PrintThe Totalizer 2 value is cleared when a print is performed; Settings: No (default), Yes
Current Value – Allows sequential numbering for print operations; The consecutive number value is incremented following each
print operation that includes <CN> in the ticket format; Enter value: 0-999999, 0 (default)
Reset Value – Specifies the value used when the consecutive number is reset by sending the KCLRCN serial command or a
CLRCN digital input; Enter value: 0-999999, 0 (default)
Setup – Protect the setup menu; If the value is zero the password is turned off; Enter value: 0-999999, 0 (default)
Totalizer – Protect totalizer 1-2 from being reset; If the value is zero the password is turned off; Enter value: 0-999999, 0 (default)
Table 4-11. Setup – Features Menu Parameters
4.6.2.1 Features – Region Menu
Figure 4-12. Features – Region Menu
ParameterDescription
Decimal FormatSet decimal symbol to display and print; Settings: DOT (default), COMMA
TimeTime Format – specify time format; Settings: 12HOUR (default), 24HOUR
Time Separator – specify time separator; Settings: COLON (default), COMMA
Set – enter current time
The 882D supports a user password, a setup password, and a totalizer password. Passwords are numeric and will accept up to
six characters. A password can be enabled by setting a non-zero value. By default the passwords are disabled (value of zero).
• The user password protects access to certain areas of the top level menu - Test, Time & Date and Setpoints are
protected; Audit is not protected
• The setup password protects access to the setup menu; If the setup password is set with a non-zero value it must be
entered whether using the setup switch (audit jumper OFF) or the front panel (audit jumper ON) to enter configuration
• The totalizer password protects totalizers 1 & 2 from being cleared in weigh mode
4.6.2.3 Configuration Reset Password
The configuration reset password is 999999.
Entering the configuration reset password at a password prompt resets the 882D - all configuration is returned to defaults. If
either the user, setup or totalizer password has been forgotten, the configuration reset password can be entered to allow
access to the 882D. This does not clear the master totalizer.
The configuration reset password is also a valid password for a customer to configure. If the customer forgets this password
and calls Rice Lake (or looks it up in the manual) and is instructed to enter the configuration reset password, the configuration
reset password allows them access without performing a reset of configuration.
4.6.2.4 Features – Key Locks Menu
ParameterDescription
Zero
Setpoint
Print
Mode
Menu
Num
CLR
Dot
F1-4
Lock or unlock individual keys; Settings: UNLOCK (default), LOCK
NOTE: The Num parameter locks or unlocks all of the numeric keys. The numeric keys cannot be individually controlled.
Figure 4-13. Features – Key Locks Menu
Table 4-13. Key Locks Available
36Visit our websitewww.RiceLake.com
Page 37
4.6.3Setup – Ports Menu
COM
Setup
Ports
USBCOMEthernetFieldbus
COM
Ports
USBCOM
TriggerBaudBitsStop BitsTerminationEchoResponse
TypePrint MessageStream Format
End of Line
Delay
TriggerTerminationEchoResponsePrint MessageStream Format
End of Line
Delay
ParameterDescription
COMRS-232 and RS-485 Communications Port – see Figure 4-15
USBCOMUSB Device Port – see Figure 4-15
EthernetEthernet TCP/IP Port – see Figure 4-16 on page 38.
FieldbusFieldbus option card port when installed – see Figure 4-16 on page 38
Table 4-14. Setup – Ports Menu Parameters
4.6.3.1 Ports – COM and USBCOM Menus
Configuration
Figure 4-14. Setup – Ports Menu
Figure 4-15. Ports – COM and USBCOM Menus
NOTE: USBCOM refers to the communication with the micro USB connector.
ParameterDescription
TriggerCOMAND (default) – allows operation of EDP commands and printing
STRIND – stream Industrial data; data updated up to configured sample rate; allows operation of EDP commands and printing
STRLFT – stream Legal for Trade data; data updated at configured display update rate; allows operation of EDP commands and printing
PROGIN (Programmable input) – used with an iRite user program
NOTE: If Type is set to RS485, the port will not stream data. The 882D does not support local/remote operation. See Section 12.4.4 on page 95.
BaudPort baud rate (Not available in USBCOM); Settings: 1200-115200, 9600 (default)
BitsPort data bits and parity (Not available in USBCOM); Settings: 8NONE (default), 7EVEN, 7ODD
Stop BitsStop Bits – selects the number of stop bits transmitted and the number of stop bits expected to be received by the port
(Not available in USBCOM); Settings: 1 (default), 2
TerminationTermination – selects the termination character(s) for data sent from the port; Settings: CR/LF (default), CR
EchoSpecifies whether characters received by the port are echoed back to the sending unit; Settings: ON (default), OFF
ResponseSpecifies whether the port transmits replies to serial commands; Settings: ON (default), OFF
End of Line Delay Specifies, in 0.1 second intervals, the delay between transmitted lines of data; Settings: 0 (default), 0-255
TypeSpecifies the protocol for the COM port (Not available in USBCOM); Settings: 232 (default), 422, 485
Print MessageDisplays a message when a print is transmitted on this port; Settings: ON (default), OFF
Stream FormatSpecifies the stream format used for streaming output of scale data (Trigger=STRLFT or STRIND); <R><NL>(default)
DHCPDynamic Host Configuration Protocal; Settings: ON (default), OFF
If DHCP is ON, the five parameters below are configured and set automatically by the network’s DHCP server;
If DHCP is OFF, the five parameters below must be manually configured as needed
IP AddressIP address (000.000.000.000)
NetmaskNetmask (000.000.000.000)
Default GatewayIP address for the Default Gateway; (000.000.000.000)
DNS PrimaryIP address for the primary DNS server; (000.000.000.000)
DNS SecondaryIP address for the secondary DNS server; (000.000.000.000)
ServerSee sub-menu parameters below
ClientSee sub-menu parameters below
Mac AddressThe MAC address for this device; Read Only
Server/Client Sub-menu
Remote IP AddressClient only: the IP address of the remote server the 882D is connecting to (000.000.000.000)
Remote PortClient only: the TCP port number of the remote server the 882D is connecting to; Enter value: 1-65535, 1 (default)
PortServer only: The TCP port number of the 882D server; Enter value: 1-65535, 10001 (default)
TriggerSelect the operation of the port; Settings:
TerminationSelects the termination character(s) for data sent from the port; Settings: CR/LF (default), CR
End of Line DelaySpecifies the delay between transmitted lines of data, in 0.1 second intervals; Enter value: 0-255, 0 (default)
TimeoutConnection (client or server) is closed if there is no activity before the set time; 0 disables the inactivity disconnect;
38Visit our website www.RiceLake.com
COMAND (default) – allows operation of EDP commands and will print
STRIND – stream industrial scale data – data is transmitted up to the configured A/D sample rate; Will also accept EDP
commands and printing
STRLFT – stream legal for trade scale data – data is transmitted at the configured display update rate; Will also accept EDP
commands and printing
PROGIN – programmable input for use with an iRite user program
Enter value: 0-65535 (seconds), 0 (default)
Table 4-16. Ports – Ethernet Parameters
Page 39
Configuration
Print Format 1
Setup
FormatPort
COMUSBCOM
Print Format 2Print Format 3Print Format 4
Ethernet ServerEthernet Client
Print Formats
ParameterDescription
Stream FormatSpecifies the stream format used for streaming output of data (Trigger = STRLFT or STRIND); Alpha/numeric maximum length
200 characters; <R><NL> (default)
EchoSpecifies whether characters received by the port are echoed back to the sending unit; Settings: OFF (default), ON
ResponseSpecifies whether the port transmits replies to serial commands; Settings: ON (default), OFF
NOTE: If an external device (such as a printer), that may transmit unexpected data (such as a paper low message), is
connected to the 882D the response parameter should be set to OFF to prevent a reply from the 882D from confusing the
SwapSpecifies byte-swapping used for the fieldbus card. For DeviceNet cards, this parameter defaults to BYTE; for all other cards the
default value is None; Settings: NONE (default), BYTE, BOTH
DeviceNetSpecifies the DeviceNet address; Address – Enter value: 1-64, 63 (default)
ProfibusSpecifies the Profibus address; Address – Enter value: 1-126, 126 (default)
Table 4-17. Ports – Fieldbus Parameters
4.6.4Setup – Print Format Menu
Figure 4-17. Setup – Print Format Menu
ParameterDescription
FormatSet format needed to print tickets; see Section 8.0 on page 77
PortCommunications port the print data will be sent to:
COM – RS-232/422 port; J3
USBCOM – USB Device Port; J4
Ethernet Server – J6
Ethernet Client – J6
Ports can be configured as ON or OFF; COM is ON by default and the
others are OFF by default
When a Print Format is requested, it will be sent simultaneously out all of the
ports configured as ON
Setpoint Config 20 setpoint steps are supported; See Table 4-20 for the setpoint types and descriptions; Settings: Setpoint 1-20
BatchingSet to MANUAL to allow a batch sequence to run; MANUAL requires a BATSTR digital input or BATSTART serial command before
ParameterDescription
OFFSetpoint turned off/ignored (default)
RATERate setpoint: Performs functions based on the current rate;
% RATEPercent rate setpoint: Performs functions based on a specified percentage of the configured max capacity;
LOADLoad setpoint: Performs functions based on the current load;
SPEEDSpeed setpoint: Performs functions based on the belt speed;
TOTALTotalizer setpoint: Performs functions based on the totalizer value;
CELL MVLoad cell millivolt setpoint: Performs functions based on the current cell mV reading;
PAUSEPauses the batch sequence indefinitely; a BATSTRT signal must be initiated to continue the batch process;
DELAYDelays the batch sequence for a specified time; the length of the delay (in tenths of a second) is specified on the Value setting;
NOTE: Refer to Table 4-21 on page 41 for setpoint parameter settings and descriptions.
40Visit our websitewww.RiceLake.com
Figure 4-18. Setup – Setpoints Menu
the batch sequence can run; Settings: OFF (default), MANUAL
Table 4-19. Setup – Setpoints Menu Parameters
Settings: Value, Trip, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Value, Trip, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Value, Trip, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Value, Trip, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Value, Source, Trip, Preact, Preact Value, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Value, Trip, Batch Sequence, Push Print, Access, Name, Slot, Digital Output, Sense
Settings: Access, Name, Slot, Digital Output, Sense
Settings: Value, Push Print, Access, Name, Slot, Digital Output, Sense
Table 4-20. Setup – Setpoint Parameters
Page 41
Configuration
SettingDescription
ValueFor time-based setpoints: Specifies, in 0.1 second intervals, a time value; For all other setpoints: Specifies the target value;
Settings: 0.000000 (default)
0.0-65535 ― for the DELAY setpoint
0.0-999999 ― for the RATE, %RATE, LOAD, SPEED, TOTAL and CELLMV setpoints
SourceThe source for a TOTAL setpoint type; Settings: TOTALIZER 1 (default), TOTALIZER 2, MASTER
TripSpecifies whether the setpoint is satisfied when the weight is higher or lower than the setpoint value;
Settings if using batch setpoints:
HIGHER (default) ― the associated digital output is active until the setpoint value is reached or exceeded
LOWER ― the associated digital output is active until the current value goes below the setpoint value
Settings if using continuous setpoints:
HIGHER (default) ― the associated digital output is active when the associated value is greater (higher) than the setpoint value
LOWER ― the associated digital output is active when the associated value is less (lower) than the setpoint value
PreactAllows the digital output associated with a setpoint to shut off before the setpoint is satisfied to allow for material in suspension;
Settings:
OFF (default) ― disables the preact
ON ― adjusts the setpoint trip value up or down (depending on the TRIP parameter setting) from the setpoint value using a fixed
value specified on the Preact Value parameter; Weight based example - a value of 2 = turn off 2 tons early
LEARN ― monitors the load amount on the specified distance of belt and adjusts the setpoint trip value up or down (depending
on the TRIP parameter setting); For example - a value of 15 ft (and a current load of 20 lb/ft) will turn off 0.08 tons early,
20 lb x 15 ft = 300 lb = 0.08 tons
Preact ValueSpecifies the preact value for setpoints with Preact set to ON or LEARN; Depending on the trip setting specified for the setpoint, the
setpoint trip value is adjusted up or down by the Preact Value; Enter value: 0.0-999999.0, 0.0 (default)
Batch
Sequence
Push PrintSpecifies which print format to transmit; Settings: NONE (default), PRINT FORMAT 1, PRINT FORMAT 2, PRINT FORMAT 3,
AccessSpecifies the access allowed to setpoint parameters through the setpoint key;
NameSetpoint name string; Settings: (six characters)
SlotDigital output slot; Lists all digital I/O slots that have at least one bit configured as an output; This parameter specifies the slot
Digital OutputLists all digital output bits available for the specified Slot; This parameter is used to specify the digital output bit associated with this
SenseDigital output sense; Specifies whether the value of the digital output associated with this setpoint is inverted when the setpoint is
Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint; Settings: OFF (default), ON
PRINT FORMAT 4
Settings:
ON (default) ― values can be displayed and changed
OFF ― values can be displayed but not changed
number of the digital I/O card referenced by the Digital Output parameter;
Settings:
NONE (default) ― specifies no digital output being used by the setpoint
SLOT0 ― the onboard digital outputs; only shown if at least one output is configured
SLOT1 ― the digital I/O option card; only shown if the card is installed and if at least one output is configured
SLOT2 ― the digital I/O option card; only shown if the card is installed and if at least one output is configured
Refer to Section 4.6.6 on page 42 to activate setting.
setpoint; Use the Digital I/O menu to assign bit function to output; For continuous setpoints, the digital output becomes active (low)
when the condition is met; for batch setpoints, the digital output is active until the setpoint condition is met;
Settings: NONE (default), BIT1-24 (refer to Section 4.6.6 on page 42 to activate setting)
NOTE: When using a fixed speed, make sure to set the Digital I/O to BELTRUNNING and use the J2 connector to wire that
Digital I/O to ground. The Digital I/O must be held low (grounded) to see the fixed speed. Not grounding the Digital I/O could
cause calibration issues.
ParameterDescription
Slot 0Select the bit to set the function; Settings: Bit 1 - 4
Slot 1
Slot 2
Slot 0-2 submenu
Bit nSpecifies the function activated by Bits n;
Settings: Bit 1 - 24
Settings:
OFF (default) ―turned off
PRINT, ZERO, CLEAR, MODE ― provide the same functions as the front panel keys
CLRCN ― resets the consecutive number to the value specified on the Reset Value parameter
(Features menu, Table 4-11 on page 35)
BATRUN ― allows a batch routine to be started and run; With BATRUN active (low), the BATSTR input starts
the batch; if BATRUN is inactive (high), BATSTR resets the batch
BATSTR ― starts or resets a batch routine, depending on the state of the BATRUN input
BATPAS ― pauses a batch routine while held active (low)
BATRST ― resets a batch to first batch setpoint
BATSTP ― stops a batch at the current step
KBDLOC ― locks the keyboard
OUTPUT ― defines a bit as an output to be used by a setpoint
INPUT ― assigns the bit as a digital input that can be read with the GetDigin iRite API
PROGIN ― assigns the bit as a digital input used to generate an iRite program event
BELTRUNNING ― an input to tell the 882D the belt is running; if not configured, the belt is always considered
running; must be configured if using Fixed Speed
CLRTOT1 ― clears Totalizer 1
CLRTOT2 ― clears Totalizer 2
TOTALIZERPULSE ― an output that pulses with each predefined amount of material that crosses the scale;
See Total Pulse parameters in Figure 4-8 on page 33 to configure the amount indicated by each pulse
Table 4-22. Setup – Digital I/O Menu Parameters
42Visit our websitewww.RiceLake.com
Page 43
4.6.7Setup – Analog Output Menu
Analog Out 1
Setup
Analog Output
SourceModeError Action
Analog Out 3
MinimumMaximum
Calibrate ZeroCalibrate Span
Output
Figure 4-20. Setup – Analog Output Menu
NOTE: Option slot 1 on the CPU board is Analog Out 1 and option slot 2 is Analog Out 3.
ParameterDescription
SourceSpecifies the source of the analog output control;
Settings:
SCALE (default) ― Indicates that the analog output will follow the configured mode based on scale data.
PROG ― Indicates that the analog output is under iRite program control
ModeSpecifies the data tracked by the analog output; Source must be configured for SCALE for the analog output to
follow any of these modes; Settings: RATE (default), SPEED, LOAD
OutputSpecifies the output type; This parameter must be set before calibrating the analog output;
Settings: 0–10 V (default), 0-20mA, 4-20mA
Error ActionSpecifies how the analog output responds to system error conditions;
Settings:
FULLSC (default) ― Set to full value (10 V or 20 mA, depending on output setting)
HOLD ― Hold current value
ZEROSC ― Set to zero value (0 V, 0mA or 4 mA, depending on output setting)
MinimumSpecifies the minimum value tracked; Enter value: 0–999999, 0.0 (default)
MaximumSpecifies the maximum value tracked; Enter value: 0–999999, 10000.0 (default)
Calibrate ZeroAdjust the analog output zero calibration; See Section 12.5 on page 96
Edit the value to match reading on multimeter to perform calibration
Calibrate SpanAdjust the analog output span calibration; See Section 12.5 on page 96
Edit the value to match reading on multimeter to perform calibration
SoftwareDisplays firmware version number (read only); VX.XX.XX 882D CCCC
NOTE: The CCCC is the 4-digit firmware checksum
RegulationDisplays the Legally Relevant firmware version number (read only); LRVX.XX
DefaultPerforms a reset of all the 882D parameters to factory default settings; Settings: NO, YES
Important: All configuration and calibration data will be lost
Table 4-24. Setup – Version Menu Parameters
4.6.8.1 Defaulting 882D
A complete default can be done to the 882D. This will clear the totalizers and the calibration settings. The 882D will be returned
to all default settings.
1.Press . Audit is displayed.
2.Press . Setup is displayed.
3.Press . Scale is displayed.
4.Press . Version is displayed.
5.Press . Software is displayed.
6.Press . Default is displayed.
7.Press . NO is displayed.
8.Press . YES is displayed.
9.Press . SAVED then RESET briefly display.
10. Press to return to the weigh mode.
44Visit our website www.RiceLake.com
Page 45
4.7Test Menu
Pulse Input
Test
Master Total
Reset
Input 1Input 2
Time
Time & Date
Date
Pulse InputDisplays the current PPS (pulses per second) from the speed sensor (read only);
Master Total ResetOption to reset the master total; Settings: NO (default), YES
The 882D Belt Scale Integrator must calibrate inputs from the speed sensor and weigh frame for the system to work.
NOTE: The speed sensor calibration must be done prior to the weigh frame calibration.
5.1Speed Sensor Calibration
A belt conveyor scale must be equipped with a belt speed sensor that accurately senses the belt speed when the belt is empty
or loaded.
The purpose of the calibration is to determine a belt speed in either m/s or ft/s (depending on the units setting).
There are three types of speed sensor calibrations supported:
• Calculated – the belt speed is calculated from known parameters of the speed sensor.
• Revolutions – the belt speed is determined by measuring the number of complete revolutions.
• Distance – the belt speed is determined by measuring the speed sensor output over a set distance.
NOTE: Only one of these methods should be performed.
Figure 5-1. Speed Sensor Calibration Menu
5.1.1Calculated
This section details speed sensor calibration via the Calculated method. The belt speed is determined by the diameter of the
sensor (which is needed to find its circumference) and its pulses per revolution.
Calculation
The sensor circumference is divided by the seconds per revolution and then multiplied by 60 to calculate the belt’s speed in feet
per minute.
The circumference of the sensor is determined with the equation:
C = π x d
Example: Assume the speed sensor outputs 120 pulses per second, is rated at 250 pulses per revolution and has
a diameter of 6 inches.
Circumference:
C = 3.14159 x 0.5 feet
C = 1.570795 feet per revolution
Pulses per revolution / Pulses per second:
250 / 120 = 2.08333 seconds per revolution
Distance per minute:
1.570795 / 2.08333 = 0.753983 feet per second
0.753983 x 60 seconds per minute = 45.23897 feet per minute
d = diameter of pulley
Figure 5-2. Measure of Pulley Diameter
46Visit our websitewww.RiceLake.com
Page 47
Calculated Speed Calibration
MODE
MODE
MODE
MODE
MODE
ENTER
MODE
ENTER
MODE
F1
START
MENU
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press . Pulse Input 1 displays.
4.Press . Speed Cal Type CALCULATED displays.
5.Press . Pulse Per Revolution displays.
6.Press . The current Pulse Per Revolution value displays.
7.Enter required value using the keypad.
8.Press . Sensor Diameter displays.
9.Press . The current Sensor Diameter value displays.
10. Enter required value using the keypad.
11. Press . Calibrate displays.
12. Press . Start To Begin displays.
Calibration
13. Press . Complete briefly flashes in the messaging area.
14. Press to return to the weigh mode.
5.1.2Revolutions
This section details speed sensor calibration via the number of belt revolutions. The distance per pulse is determined by how
many pulses are received for a number of belt revolutions. The Belt Length parameter must be configured before this
calibration is performed.
Calculation
The distance traveled during the calibration is divided by the calibration time in seconds and multiplied by 60 to calculate the
belt’s speed in feet per minute.
Example: Assume the belt is 100 feet and travels 3 revolutions in 240 seconds.
Total distance traveled:
100 x 3 = 300 feet traveled
Time conversion:
240 / 60 = 4 minutes
Distance per minute:
300 / 4 = 75 feet per minute
Revolutions Speed Calibration
1.Mark a reference point on the conveyor belt and conveyor frame. This allows for counting the number of revolutions the
belt travels during the speed calibration. The more revolutions in a test, the better the speed and distance accuracy.
NOTE: Time a belt revolution with a stop watch if the belt is not visible from the 882D. Use the reference marks on the belt
and conveyor frame to accurately time a complete revolution.
Be sure to configure the conveyor belt length before performing a Revolutions calibration.
2.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
8.Press . The current Test Revolutions value displays.
9.Enter expected value using the keypad.
10. Press . Calibrate displays.
11. Press . Press Start To Begin displays.
12. Press . This causes the 882D to display:
• Pulses: – displays the pulses counted
• Run Time: – displays the run time as minutes and seconds
• Press Stop To Finish – displays in the lower line of the messaging area
NOTE: If the pulses are not changing there is a problem with the speed sensor and can be a sign that the wiring or the
sensor is bad.
13. Press to stop the calibration once the belt has completed the desired number of revolutions.
14. The current value of Test Revolutions displays again.
15. Enter the number of revolutions just completed using the keypad.
16. Press . The 882D determines the pulses per unit of measure to be used for displaying the speed of the belt
and totalizing the weight during operation.
17. Press to return to the weigh mode.
The number of belt revolutions is stored. This value is used for dynamic span calibration (static weight or test chain span
calibration) when the 882D is calibrated to the load cell.
48Visit our website www.RiceLake.com
Page 49
Calibration
MODE
MODE
MODE
SETPOINT
MODE
MODE
ENTER
MODE
F1
START
F2
STOP
ENTER
MENU
5.1.3Distance
This section details speed sensor calibration via belt travel distance. The belt speed is determined by how many pulses are
received for a length of belt travel.
Calculation
The distance traveled during the calibration is divided by the calibration time in seconds and multiplied by 60 to calculate the
belt’s speed in feet per minute.
Example: Assume the belt travels a test distance of 100 feet in 40 seconds.
Distance per minute:
100 / 40 = 2.5 feet per second
2.5 x 60 seconds per minute = 150 feet per minute
Distance Speed Calibration
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press . Pulse Input 1 displays.
4.Press . Speed Cal Type CALCULATED displays.
5.Press to scroll to DISTANCE.
6.Press . Test Distance displays.
7.Press . The current Test Distance value displays.
8.Enter required value using the keypad.
NOTE: Two reference points must be marked on the conveyor belt and one reference point must be marked on the
conveyor frame. This gives the operator a reference for the distance that the belt travels during the speed calibration.
9.Press . Calibrate displays.
10. Press . Press Start To Begin displays.
11. Press . This causes the 882D to display:
• Pulses: – displays the pulses counted
• Run Time: – displays the run time as minutes and seconds
• Press Stop To Finish – displays in the lower line of the messaging area
NOTE: If the pulses are not changing there is a problem with the speed sensor and can be a sign that the wiring or the
sensor is bad.
12. Press to stop the calibration as close as possible to the specified test distance.
13. The current value of Test Distance displays again.
14. Enter the distance value just completed using the keypad.
15. Press . Calibrating... briefly displays. The 882D determines the pulses per unit of measure to be used for
displaying the speed of the belt and totalizing the weight during operation.
Zero calibration of the 882D while the belt is not in motion. The zero calibration is based on four seconds of A/D readings.
Static Zero Calibration
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press to scroll to Weigh Frame.
4.Press . Static Zero displays.
5.Press . Press Start to Begin displays.
6.Ensure that there is no material on the belt.
7.Press to initiate the calibration sequence. Calibrating... displays on the upper messaging line and a bar graph
on the bottom line displays the progress of the calibration.
NOTE: Once “Press Start to Begin” displays, pressing MENU is the only way to cancel.
8.After the calibration is complete Static Zero displays again. Press to return to the weigh mode.
5.2.2Dynamic Span
NOTE: See Section 5.2.3 on page 52 to run a dynamic zero calibration before proceeding with a span calibration. The
dynamic zero determines the span’s reference point.
5.2.2.1 Test Weight or Chain
Select Test Weight or Chain to calibrate the span using the number of revolutions as a reference for the calibration duration.
Span calibrations are based on belt length defined by number of revolutions and uses static test weights or chains.
Test Weight or Chain Span Calibration
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press to scroll to Weigh Frame.
4.Press . Static Zero displays.
50Visit our website www.RiceLake.com
Page 51
Calibration
PRINT
MODE
MODE
PRINT
MODE
MODE
ENTER
MODE
F1
START
ENTER
MENU
MODE
PRINT
MODE
PRINT
MODE
MODE
SETPOINT
MODE
5.Press to scroll to Dynamic.
6.Press . Span displays.
7.Press . Test Weight displays. If using chain, press to display Chain.
8.Press . Test Weight Value displays (Chain Weight, if using chain).
9.Press . The current Test Weight Value or Chain Weight displays.
10. Enter the amount of test weight being used or the chain weight with the keypad.
11. Load the scale with weights or chains, press . Calibrate displays.
12. Press . Press Start to Begin displays.
NOTE: Ensure the belt is running prior to pressing Start.
13. Press . Calibrating... displays.
• The 882D starts taking span averages
• During calibration the test totalizer displays in the numeric area, a progress bar graph displays in the messaging area
• The weight being totalized during calibration displays at x10 resolution
• Calibration runs for the Test Distance set in the Configuration menu (default 20 ft/m)
• The 882D displays the previous error, the current error and displays Enter Key To Accept on the bottom line of the
messaging area
14. Press . ACCEPTED displays, the error and the new span value is stored.
- OR Press to reject the calibration. REJECTED displays.
5.2.2.2 Material
Use this method to calibrate the scale with a known amount of material. The material must be pre weighed or post weighed.
Material Calibration
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press to scroll to Weigh Frame.
4.Press . Static Zero displays.
5.Press to scroll to Dynamic.
6.Press . Span displays.
7.Press . Test Weight displays.
8.Press to scroll to Material.
9.Press . Material Weight displays.
NOTE: The pre or post weighed material weight is entered in Step 14.
12. Press . The 882D starts recording span averages.
• Displays: Calibrating...
Run Time: XX:XX
• The weight being totalized during calibration displays in the numeric area at x10 resolution.
• Total annunciator is lit, but 1 and 2 are not.
13. Once the material is run across the belt scale, press to end the sequence.
14. The 882D prompts for the amount of material in tons with the previously entered value as a default starting point.
15. Press to accept the default value
- OR Use the keypad to enter a new value and press . The new value is saved to configuration.
NOTE: Pressing aborts the calibration.
16. The 882D displays the previous error, the current error and prompts to accept or reject the calibration. Enter Key To
Accept displays on the bottom line of the messaging area.
17. Press . ACCEPTED displays, the error and the new span value is stored.
- OR Press to reject the calibration. REJECTED displays.
5.2.3Dynamic Zero
Zero calibration of the 882D while the belt is in motion.
Dynamic Zero Calibration
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press to scroll to Weigh Frame.
4.Press . Static Zero displays.
5.Press to scroll to Dynamic.
6.Press . Span displays.
7.Press to scroll to Zero. Ensure there is no load on the belt and that the belt is moving.
8.Press . Zero Counts displays.
9.Press to scroll to Calibrate.
10. Press . Press Start to Begin displays.
52Visit our website www.RiceLake.com
Page 53
11. Press . If a Speed Sensor Calculation was performed, the unit prompts for a distance to calibrate.
F1
START
F2
STOP
ENTER
MENU
MODE
PRINT
MODE
SETPOINT
MODE
PRINT
MODE
MODE
ENTER
MODE
ENTER
MENU
• The 882D will start taking zero averages.
• During calibration the test totalizer displays in numeric area, a progress bar graph displays in messaging area
• The weight being totalized during calibration displays at x10 resolution
Calibration
NOTE:
Press to cancel the calibration, if needed. Canceled displays momentarily and the 882D exits the calibration.
12. Calibration runs for the calibrated distance (or the entered distance if using Calculated Speed). After the 882D has run
the zero calibration, the new zero error % and the previous zero error % display. Press Enter To Accept displays on the
bottom line of the messaging area.
13. Press to accept the calibration. Zero ACCEPTED flashes briefly, and the new zero error % is stored – the
test totalizer value is not adjusted.
- OR Press to reject the calibration. REJECTED displays.
5.2.4Linearization
Linearization allows up to five correction points to be configured as a percentage of Max Capacity. A separate Percent Capacity
and Correction Factor is maintained for each Point. A span calibration (
linearization points and populates Point 1 by setting Percent Capacity 1 to 100.0 and creating a value for Correction Factor 1.
Linearization Point Entry
1.Navigate to Calibration within the Setup menu (Section 4.6.1 on page 30).
2.Press . Speed Sensor displays.
3.Press to scroll to Weigh Frame.
Section 5.2.2 on page 50
) clears out any existing
4.Press . Static Zero displays.
5.Press to scroll to Linearization.
6.Press . Point 1 displays.
NOTE: A span calibration populates the Correction Factor 1 percentage value for Point 1. Repeat steps 7 through 14 for all
of the additional points that are needed.
7.Press to scroll to the desired point. Point X displays.
8.Press . Percent Capacity X displays.
9.Press . The current percent capacity for the point displays.
10. Enter a new percent capacity value for the point with the keypad, if necessary.
11. Press . Correction Factor X displays.
12. Press . The current correction Factor value for the point displays.
13. Enter a new correction Factor value for the point with the keypad, if necessary. (Section 5.2.4.1 on page 54)
14. Press . Percent Capacity X displays again.
15.
Repeat steps 7 through 14 for additional points as needed or press to return to the weigh mode.
The Correction Factor adjusts the span value to correct for dynamic loading at the weigh frame. After completing a zero and
span calibration, material tests as a percentage of Max Capacity can be run to calculate correction factor values for each
linearization point. It is recommended that at least three material tests must be ran for each linearization point and the
calculated correction Factor values from these tests can then be averaged and used. This value can be adjusted manually
NOTE: When exiting to weigh mode, the calibration points are reorganized from lowest to highest Percent Capacity value.
The changeover point for each range is at the Percent Capacity for that point.
When a dynamic span calibration (one point) is performed, its Correction Factor applies to the entire range.
Max Capacity is the Rate, whenever referring to Percent Capacity this is the current Rate in respect to Max Capacity.
Calculation Example
For this example assume the belt scale has a total load cell build of 100 lb with a millivolt output of 3.0 mV and a max capacity
of 180 tn/hr. Assume the belt is operating at a fixed speed of 60 ft/min and is fed by a hopper system that produces material at
a rate up to 150 tn/hr. The current Correction Factor 1 value created by the previously run Span Calibration is 99.010871.
Table 5-1 shows example values for three linearization points. The following two equations correspond with the provided
values:
• Calculated Correction Factor = (Actual Weight ÷ Registered Weight) x Current Correction Factor
Actual Weight = Real weight of material on the scale in tons
Registered Weight = The measured weight of material the 882D totalizer shows in tons
• New Correction Factor = (Calculated Correction Factor of Test 1 + Test 2 + Test 3) ÷ 3
For this example Correction Factor 1 is applied from 0.0 - 40.0%, Correction Factor 2 is applied from 40.1 - 70.0% and
Correction Factor 3 is applied over 70.1%.
Linearization
Point
Point 1
Point 2
Point 3
Percent
Capacity
Percent
Capacity 1
40.0
Percent
Capacity 2
70.0
Percent
Capacity 3
100.0
Material Test
Number
Test 19.39.599.01087196.926395
Test 28.58.699.01087197.859573
Test 39.89.799.010871100.031574
Test 114.714.399.010871101.780403
Test 215.214.899.010871101.686838
Test 312.813.099.01087197.487589
Test 121.421.199.010871100.418609
Test 220.820.699.01087199.972168
Test 323.123.599.01087199.010871
Actual
Weight (tn)
Registered
Weight (tn)
Current
Correction Factor
Calculated
Correction Factor
Table 5-1. Linearization Example
New Correction
Factor
Correction Factor 1
98.272514
Correction Factor 2
100.318277
Correction Factor 3
99.238795
54Visit our website www.RiceLake.com
Page 55
Using Revolution
6.0Using Revolution
The Revolution utility provides support for the 882D using a PC. Current support functions include saving and restoring
configuration files, as well as updating the operating firmware. Additional functions will be made available in future releases.
NOTE: For system requirements visit www.ricelake.com/revolution
6.1Connecting to the 882D
Communicating to the 882D can be accomplished three ways - using a serial connection to the serial (COM) port through J3;
using a USB connection and Virtual Comm Port to the USB Micro Device (USBCOM) port through J4; or using a TCP/IP
connection through the Ethernet Port (J6).
After making the physical connection to a PC, select Options in the Tools menu and configure the communications settings as
needed to match the communications method being used:
• RS-232 and RS-485 – select the COM port that it will be connected to. Settings can be configured manually to match the
current settings, or check the box for Auto Detect Settings to have Revolution automatically detect the settings.
• USB – select RS-232 as the communication mode. The USB connection appears as a standard COM port to Revolution.
The comm port for the USB connection only displays in the list of available ports if it is physically connected and powered
on. The settings for baud rate, data and stop bits, and parity do not apply for a USB connection, and do not need to be
set to any specific value.
• TCP/IP – requires the IP address and TCP Port of the 882D. Enter the IP address and port during the communications
connection.
To open the communication connection, click on Connect under the Communications menu, or the Connect button in the
Toolbar. Revolution will attempt to establish communications with the 882D.
NOTE: If Revolution does not detect the 882D, check:
* Physical connections
* Communications settings in Revolution
* Current settings of the communications port in the 882D
* 882D communications port Trigger parameter is set to Command
* If Revolution displays a Version Error, the 882D version of firmware does not match the module used in Revolution.
A connection can be forced, but some parameters may not be enabled if they were not originally supported in that
module.
6.2Saving and Restoring Configuration Files
6.2.1Uploading Configuration to Revolution
The Get Configuration from Device function in the Revolution Communications menu allows the existing configuration of a
connected indicator to be saved to a file on the PC. Once saved, the configuration file provides a backup that can be quickly
restored to the indicator if needed. Alternatively, the file can be edited within Revolution and sent back to the indicator.
NOTE: Uploading and downloading processes can take several minutes to complete.
6.2.2Downloading to the 882D
The Send Configuration to Device function in the Revolution Communications menu allows a Revolution configuration file
(with or without scale calibration data) or ticket formats to be sent/downloaded to a connected indicator in Setup mode.
The Send Section to Device function in the Revolution Communications menu allows download of only the currently displayed
section, such as the communications port configuration.
Because less data is transferred using Send Section to Device, it is typically faster than a full configuration download, but
there is an increased possibility that the download may fail due to dependencies on other objects. If the download fails, try
performing a complete download using the Send Configuration to Device function.
The firmware for the 882D CPU can be updated using a PC with a RS-232 serial port and the Revolution software package.
NOTE: ALL configuration data, including calibration, will be lost if updating the CPU firmware. Use Revolution to upload
and save a copy of the current configuration before continuing (Section 6.2 on page 55). After updating, use Revolution to
restore the configuration and calibration.
Firmware updates can only be done through the RS-232 port. Updates through the USB and Ethernet ports are not
supported.
1.Download the new CPU firmware from www.ricelake.com.
CPU firmware file – 882D_CPU_Firmware_176769_Vx_xx_xx.S19
NOTE: File names are subject to change, but always contain some designation of the device they are intended for.
2.Connect the RS-232 Port (J3) from the CPU board (Section 2.4.7 on page 16) to a PC.
3.Remove the JP2 jumper and set aside until firmware update is completed successfully (Section 12.7 on page 98).
IMPORTANT: Replace the JP2 jumper when update is complete. Normal operation of the 882D will be affected if the JP2
jumper is not put back in place.
4.Press and hold the SETUP switch (Section 4.1 on page 27) while applying power to put the 882D into BOOT mode.
The display is black for several seconds and then
5.Release the setup switch.
6.Start the Revolution software on the PC.
7.Select NEW under the File menu.
8.Select the 882D module applicable for the current version of firmware.
9.Select Options/Communications/AutoDetect under the Tools menu.
10. Select the Auto Detect Settings check box and click OK.
11. Select Connect under the Communications menu. Revolution establishes communications with the 882D.
. . . . . . . displays.
NOTE: Check the connections if communication with the 882D fails.
12. Once connected, select Update CPU Firmware in the main indicator information screen.
13. Select the file for the Firmware being updated.
The program proceeds to load new firmware. This may take several minutes. While in progress do not leave the Revolution
window or interrupt power to the 882D. The progress of the download is indicated on the 882D Information screen.
When the download is complete, the program indicates if it was successful or not.
NOTE: If it was not successful, turn off the power to the 882D, return to Step 4, and try the entire procedure again.
If problems persist, contact Rice Lake Weighing Systems for technical assistance.
56Visit our websitewww.RiceLake.com
Page 57
EDP Commands
7.0EDP Commands
The 882D can be controlled by a personal computer or terminal using EDP commands, which can access reporting and weigh
mode information, query or set the value of configuration parameters, and simulate front panel key presses.
When processing an EDP command, the 882D will either respond with the value requested, or in cases where no value was
requested, the message OK to verify that the command was received and executed. If the command is unrecognized or cannot
be executed, the 882D responds with
7.1Reporting Commands
Reporting commands are commands that report some data about the system. These commands can be used in both
configuration mode and weigh mode.
CommandFunction
AUDITJUMPERReturns the state of the audit jumper; see Section 7.1.1
BUILDReturns the date and time of the software build; see Section 7.1.2
DIN#sReturns a numeric value representing the state of all the DIO bits for slots 0-2 (s); see Section 7.1.3 on page 58
DISPLAYBUILD
DISPLAYVERSIONReturns the current display module firmware version; “NONE” is returned if no display is found
DUMPALLReturns a list of all parameter values
DUMPAUDITReturns a list of audit trail information; see Section 7.1.5 on page 58
DUMPCONFIGReturns a list of all parameter values except for setpoint data
DUMPETHReturns a list of all Ethernet parameter values
DUMPSCReturns a list of all the scale related parameter values
DUMPSPReturns a list of all setpoint parameter values
DUMPVERSIONSReturns the version information for CPU, display and option card(s)
FBTEST1Returns the status of the respective option card in slot 1; see Section 7.1.6 on page 58
FBTEST2Returns the status of the respective option card in slot 2; see Section 7.1.6 on page 58
HARDWAREReturns a value that indicates which option cards are installed in the option slots; see Section 7.1.7 on page 59
OPTVERSION#sReturns the firmware version for the attached option card in slot s; see Section 7.1.8 on page 59
PReturns the currently displayed value with units identifier based on the mode; see Section 7.1.9 on page 59
PnReturns the currently displayed text on the message area line 1-3 (n); see Section 7.1.10 on page 59
VERSIONReturns the 882D software version, model number, and 4-digit software checksum value
Returns the date and time of display module software build; “NONE” is returned if no display is found; see
??.
Section 7.1.4 on page 58
Table 7-1. Reporting Commands
7.1.1AUDITJUMPER
A response of OK indicates the jumper is in the ON position; A response of ?? indicates the jumper is in the OFF position.
Example: If bits 1 and 3 are active and all the rest are inactive, then the returned value would be 5.
7.1.4DISPLAYBUILD
Returns the date and time of the display module software build.
Response: DISPLAYBUILD=MMM DD YYYY HH:MM:SS
7.1.5DUMPAUDIT
Outputs an audit report. Example:
882D Audit Trail Report<CR><LF>
<current time and date><CR><LF>
Event 1 <time and date of event<CR><LF>
MAXCAPACITY=300.0<CR><LF>
Event 2 <time and date of event><CR><LF>
UID=stone<CR><LF>
MAXCAPACITY=400.0<CR><LF>
7.1.6FBTEST1-2
This Anybus module test command can be used to test for the presence and functionality of the fieldbus carrier board and a
connected Anybus module.
Command: FBTEST1 (Slot 1) or FBTEST2 (Slot 2)
Response: FBTEST1=<status> or FBTEST2=<status>
Where <status> =
NOTFOUND – fieldbus option card not found or not operational
NOMODULE – a fieldbus option card is installed but a fieldbus module was not found, is not a recognized module, or
is not operational; the ID reported by the module will also be included
Example: “NOMODULE – 0x000”
MODBUS – a fieldbus option card is installed and an operational Modbus module was found
PROFIBUS – a fieldbus option card is installed and an operational Profibus module was found
ETHERNET_IP – a fieldbus option card is installed and an operational Ethernet IP module was found
DEVICENET – a fieldbus option card is installed and an operational DeviceNet module was found
PROFINET – a fieldbus option card is installed and an operational ProfiNet module was found
ETHERCAT – a fieldbus option card is installed and an operational EtherCAT module was found
58Visit our website www.RiceLake.com
Page 59
EDP Commands
7.1.7HARDWARE
Returns codes representing the type of option card(s) installed. Response: HARDWARE=xxx,yyy,zzz – where xxx represents
the on-board USB option (currently always 000), yyy represents slot 1 and zzz represents slot 2.
Example response with a 4-channel relay card installed in slot 1 and an analog output card in slot 2:
HARDWARE = 000,085,153
7.1.8OPTVERSION#s
Returns the firmware version of the card in slot s. Returns NOCARD if no option card is installed. Returns UNSUPPORTED if
the firmware in the option card does not support the command.
7.1.9P
Returns the currently displayed value including the units.
Data Description
For this section:
wwwwwwwww – 9 character locations for weight including decimal and negative sign, leading spaces replace any unused
locations; Negative value denoted by a ‘-’ (hex 0x2d) placed immediately before the value
<sp> – space (hex 0x20)
uu – units label
<term> – configured terminator for the port
& – ampersand (hex 0x26)
: – colon (hex 0x3a)
<menu_heading> – the currently displayed menu header name
<parameter_value> – the currently displayed parameter value
<message> – a message displayed while in weigh mode
Weigh Mode
Response in weigh mode with nothing in message area: wwwwwwwww<sp>uu<term>
Value is right justified.
Response when there are characters in message area: <message><term>
Output message is left justified, no weight data output.
Example: Version<term>
Response if there is an overload: &&&&&&&<sp>uu<term>
Response if there is an underload:
Configuration Mode
Response when no parameter value is displayed: <menu_heading><term>
Menu heading output is left justified.
Response when a parameter value is displayed: <parameter_value><term>
Parameter value output is left justified, ignoring blinking cursor value.
:::::::<sp>uu<term>
7.1.10 Pn
Returns the requested line of currently displayed text from the message area.These commands work in all modes of operation.
P1 – Returns the text from line 1 of the message area (top)
P2 – Returns the text from line 2 of the message area (middle)
P1 – Returns the text from line 3 of the message area (bottom)
The response will always be verbatim with the text from the display and fixed at 20 characters, any unused locations are
padded with spaces.
The weigh mode commands transmit data to a data communications port on demand. All commands are valid in both weigh
and setup modes unless noted otherwise.
CommandFunction
CONSNUMSet or query the consecutive number
DISPLAYMODESet or query the current weigh mode display screen
UIDSet or query the unit ID; value is alphanumeric, up to 16 characters
SDSet or query the date; enter six-digit date using the year-month-day order specified for the DATEFMT parameter,
using only the last two digits of the year
STSet or query the time; enter the time using 24-hour format
SX
SX#n
EX
EX#n
RSReset system; this is a soft reset; used to reset the 882D without resetting the configuration to the factory defaults.
S
MT
T1
T2
LD
SPD
RATE
RT1Resets the totalizer 1 value
RT2Resets the totalizer 2 value
XEReturns a decimal representation of any error conditions
XEHReturns a hexadecimal representation of any error conditions
1 – The stream related commands are only valid for ports configured to stream data (EDP.TRIGGER#p = STRLFT or STRIND)
2 – These commands are only valid in weigh mode
3 – For these commands, add the suffix “_V ” to return the value without units (example: send RATE_V to return the rate without units)
4 – “n” represents the communications port (1=COM, 2=USBCOM, 3=Ethernet Server, 4=Ethernet Client)
Start serial port streaming on the connected port
Start serial port streaming on port n
Stop serial port streaming on the connected port
Stop serial port streaming on port n
Returns a single stream frame using the format configured for the connected port
Returns the master totalizer value
Returns the totalizer 1 value
Returns the totalizer 2 value
Returns the load value
Returns the speed value
Returns the rate value
23
23
23
124
124
23
23
23
Table 7-3. Weigh Mode Commands
12
12
2
7.2.1DISPLAYMODE Command
This command switches to the specified display mode weight screen.
DISPLAYMODE = x
Where x is one of the following:
Sending DISPLAYMODE without a value will return the current value.
60Visit our website www.RiceLake.com
Page 61
EDP Commands
7.2.2Totalizer Value Reporting
Returns the respective totalizer value MT, T1 and T2.
Response: wwwwwww<sp>uu<term>
Where:
wwwwwww – value, includes leading spaces
<sp> – space (hex 0x20)
uu – units label, as determined by Totalizer Resolution parameter, 2 characters, right justified, leading space if necessary
<term> – configured terminator for the port
7.2.3Load Value Reporting
Returns the current load value LD.
Response: wwwwwww<sp>uuuuu<term>
Where:
wwwwwww – value, includes leading spaces
<sp> – space (hex 0x20)
uuuuu –
units label (lb/ft or kg/m), as determined by Units parameter, 5 characters, right justified, leading space if necessary
<term> – configured terminator for the port
7.2.4Speed Value Reporting
Retruns the current speed value SPD.
Response: wwwwwww<sp>uuuu<term>
Where:
wwwwwww – value, includes leading spaces
<sp> – space (hex 0x20)
uuuu – units label (m/s or ft/m), as determined by Units parameter, 4 characters, right justified, leading space if necessary
<term> – configured terminator for the port
7.2.5Rate Value Reporting
Returns the current speed value RATE.
Response: wwwwwww<sp>uuu<term>
Where:
wwwwwww – value, includes leading spaces
<sp> – space (hex 0x20)
uuu – units label, as determined by rate resolution parameter, 3 characters, right justified, leading space if necessary
<term> – configured terminator for the port
7.2.6XE and XEH Error Code Output
The XE and XEH commands return a representation of any existing error conditions as described in Table 7-4. If more than one
error condition exists, the number returned is the sum of the values representing the error conditions. The XE command returns
the value as a decimal representation and the XEH command returns the value as a hexadecimal representation.
NOTE: TCPERR – TCP initialization was not completed in a timely manner (2.5 seconds). When this error is raised all TCP
functionality is disabled.
7.3Key Press Commands
Key press EDP commands simulate pressing the keys on the front panel of the 882D. These commands can be used in both
setup and weigh mode. Several of the commands serve as “pseudo” keys, providing functions that are not represented by a key
on the front panel.
CommandFunctionCommandFunction
KMENUPress the Menu keyKLOCKLock specified front panel key;
KZEROIn weighing mode, press the Zero key
KPRINT
KCLR
KCLRCNReset consecutive number (pseudo key)
KLEFTIn menu mode, move left in the menu
KRIGHTIn menu mode, move right in the menuKDATEDisplay date (pseudo key)
KUPIn menu mode, move up in the menuKTIMEDisplay time (pseudo key)
KDOWNIn menu mode, move down in the menuKESCAPEExits the selected parameter; Returns to
KSAVEIn setup mode, saves current configuration
KEXITIn setup mode, saves current configuration
K0–K9Press number 0 (zero) through 9KF1Press the F1 key
KDOTPress the decimal point (.) (key)KF2Press the F2 key
KENTERPress the Enter keyKF3Press the F3 key
In weighing mode, press the Print
Press the CLR
(pseudo key)
then exits to weigh mode (pseudo key)
(clear) key
key
KUNLOCKUnlock specified front panel key;
KSETPOINTPress the Setpoint key
KMODEPress the Mode key
KF4Press the F4 key
For example, to lock the Zero key, enter
KLOCK=KZERO (pseudo key)
For example, to unlock the Print key, enter
KUNLOCK=KPRINT (pseudo key)
weigh mode if a parameter is not selected
(functions identical to the Menu key in
menu mode) (pseudo key)
Table 7-5. Key Press Commands
62Visit our websitewww.RiceLake.com
Page 63
EDP Commands
7.4Batching Control Commands
CommandFunction
BATSTARTBatch start – If the BATRUN digital input is active (low) or not assigned, the BATSTART command can be used to start or
resume the batch program; If the BATRUN is inactive (high), the BATSART command resets the batch program to the
first batch step
BATSTOPBatch stop – Stops the batch program at the current batch step and turns off all associated digital outputs
BATPAUSEBatch pause – Stops the batch program at the current step; All digital outputs set on by the current step are set off;
The BATSTR digital input or BATSTART serial command can be used to restart the batch program at the current step
BATRESETBatch reset – Stops the batch program and resets it to the first batch step; Run the BATRESET command after making
weigh mode changes to the batch configuration
BATSTATUSBatch status – Returns XYYY, where X = S (stopped), P (paused) or R (running); YYY = setpoint number
Table 7-6. Batching Control Commands
7.5Calibration Commands
These commands are valid only in configuration mode.
7.5.1Speed
CommandFunction
SPEED.PERFORMSPEEDCAL#nPerforms the speed calibration calculations on pulse input n
SPEED.STARTSPEEDCAL#nStarts the speed calibration process on pulse input n
SPEED.STOPSPEEDCAL#nStops the speed calibration process on pulse input n
Table 7-7. Speed Calibration Commands
7.5.2Weigh Frame
CommandFunction
SC.APPLYDYNAMICCAL#nCalculates and applies a new correction Factor; the calibration weight is then
totalized using the new correction Factor
SC.CALCULATEDYNAMICCAL#nCalculates a new span error percent
SC.DYNAMICZERO#nPerforms the weigh frame dynamic zero calculations on scale n
SC.MULTICALPOINT#nSelect which dynamic span point is being calibrated; this must be sent before
performing the other steps (not needed when performing a zero calibration)
SC.REJECTDYNAMICCAL#nTotalizes the calibration weight using the existing correction Factor
SC.SPANCALDISTANCETRAVELED#nGet the distance traveled by the belt during the calibration on scale n
SC.STARTDYNAMICCAL#nPerforms the weigh frame dynamic span calculations on scale n
SC.STATICZERO#nPerforms the weigh frame static zero calculations on scale n
SC.TEMPERRORPERCENT#nGet the current calculated error
SC.TEMPTESTTOTALIZER#nGet test totalizer value from the just-completed dynamic calibration
Table 7-8. Weigh Frame Calibration Commands
NOTE: The 882D only supports one scale. “n” at the end of a command represents the scale number.
7.6RESETCONFIGURATION Command
The RESETCONFIGURATION command can be used in configuration mode to restore all configuration parameters to their
default values.
This command is equivalent to using the Default function under the Version menu in the Configuration mode.
NOTE: Totalizer 1 and 2 are reset and load cell calibration settings are lost when RESETCONFIGURATION command is run.
Parameter setting commands allow to query or change the current value for a particular configuration parameter.
Current configuration parameter settings can be queried in either configuration mode or weigh mode using the following syntax:
command<CR>
Most parameter values can be changed in configuration mode only; some setpoint parameters listed in Table 7-18 on page 69
can be changed when in normal weigh mode.
Use the following command syntax when changing parameter values:
command=value<CR>
where value is the new value to assign to the parameter. Use no spaces before or after the equal (=) sign. If an incorrect
command is typed in, the response is ??.
For example, to set the dead band parameter to 3, type:
SC.DEADBAND#1=3.0<CR>
For parameters with selectable values, enter the command and equal sign followed by a question mark:
command=?<CR>
to see a list of those values. The 882D must be in configuration mode to use this function.
7.7.1Scale Menu
MenuCommandDescription
Amount per PulseSC.AMOUNTPERPULSE#nThe amount of material represented by each pulse of the digital output configured as
Angle of InclineSC.ANGLEOFINCLINE#nThe angle of the conveyor measured in degrees (°); Enter value: 0.0 - 89.0, 0.0 (default)
Auto Zero Track Band
Auto Zero Track Max
Belt LengthSC.BELTLENGTH#nThe total length of the conveyor belt (ft or m); Enter value: 1.0 - 99999.0, 500.0 (default)
Chain WeightSC.MCAL.CWp#nThe weight/length of a chain used for a dynamic span calibration (lb/ft or kg/m); For example:
Confirm ZeroSC.CONFIRMZERO#nWhether to prompt to confirm a zero operation; Applies to front panel zero key or digital input;
Linearization Point
Calibration Factor
Linearization Point
Weight
Dead BandSC.DEADBAND#nThe 882D will not totalize the amount if the rate is within the dead band value; The rate must be
Digital Filter 1-3SC.DIGFLTR1#n
Filter SensitivitySC.DFSENS#nDigital filter cutout sensitivity; Specifies the number of consecutive readings that must fall
SC.AUTOZTRKBND#nThis is the band around which auto zeroing will occur; Auto Zero cannot start until a Warm Up
SC.AUTOZEROMAX#nThis is the maximum amount that can be auto zeroed; Percentage of max capacity;
SC.MCAL.CFp#nAdjusts the span value to correct for dynamic loading at the weigh frame; This value is
SC.MCAL.Vp#nThe weight which the correction Factor for the linearization point p applies (lb/ft or kg/m);
(if any) has been run; During the auto zero sampling and actual zero process, the zero
annunciator will flash; If the weight moves out of the band, any in-progress zero is stopped/
flushed; There will be verification that the “Auto Zero Track Maximum” has not been exceeded
before starting the Auto Zero process; Percentage of max capacity;
Enter value: 0.0 - 100.0, 0.0 (default)
Enter value: 0.0 - 100.0, 0.0 (default)
when configured for METRIC units and the Chain Weight value is 100 (100 kg/m)
Enter value: 0.0 - 9999.0, 0.0 (default)
Settings:
ON (default) = prompt for zero confirmation
OFF = do no prompt and automatically accept the zero
computed during calibration but can be adjusted manually; A value of 100 is equivalent to no
adjustment; Enter value: 0.0 - 1000.0, 100.0 (default)
Enter value: 0.0 - 999999.0, 0.0 (default)
above the specified percentage of the configured Max Capacity for totalization to occur; Also,
while within the dead band value the reported rate is forced to 0; % of configured Max Capacity;
Enter value: 0.0 - 100.0, 0.0 (default)
Selects the digital filtering rate used to reduce the effects of mechanical vibration from the
immediate area of the scale; Choices indicate the number of A/D conversions per update that
are averaged to obtain the displayed reading, a higher number gives a more accurate display
by minimizing the effect of a few noisy readings, but slows down the settling rate of the
indicator; Settings: 1, 2, 4 (default), 8, 16, 32, 64, 128, 256
outside the Filter Threshold parameter before digital filtering is suspended;
Filter ThresholdSC.DFTHRH#nDigital filter cutout threshold; Specifies the filter threshold, in display divisions; When a
Distance per PulseSPEED.DPP#xThis is the distance represented by each pulse from a speed sensor (ft or m);
Display RateSC.DSPRATE#nDisplay update rate; Specifies the display update rate, in the number of 100-millisecond
Dynamic Span Type
(no menu item)
Fixed SpeedSC.FIXEDSPEED#nSpecifies a fixed belt speed for the 882D; If a non-zero value is entered the 882D no longer
Idler SpacingSC.IDLERSPACING#nDefines the spacing between the idlers (in or m); It determines the weighing surface (e.g. max
Load ResolutionSC.LOADRESOLUTION#nThe resolution for the load value; Settings: 0.1 (default), 0.2, 0.5, 1, 2, 5, 0.01, 0.02, 0.05
Material WeightSC.MCAL.MWp#nThe actual amount of material used for a material based dynamic span calibration (tn or t);
Max CapacitySC.MAXCAPACITY#nDefines the maximum rated capacity for the belt scale (the maximum amount of weight) that
Millivolt OutputSC.MVV#nThe average mV/V rating of all the load cells in the system; Enter value: 0.0 - 4.5, 3.0 (default)
Negative TotalizingSC.NEGATIVETOTALIZE#nSpecifies whether to allow values to be totalized when load value is negative, causing value to
Number of IdlersSC.NUMBEROFIDLERS#nDefines the number of idlers in the weigh frame; Enter value: 1 - 4, 1 (default)
Pulse InputSC.PULSEINPUT#nSpecifies the pulse input scheme used for speed determination and error detections
Pulse Per Revolution SPEED.PPR#xThe number of pulses output from the speed sensor per revolution;
Pulse WidthSC.PULSEWIDTH#nDefines how long the TOTALIZERPULES digital output stays on (ms);
Rate Dampening
(seconds)
Rate Dampening
(sensitivity)
Rate Dampening
(threshold)
Rate ResolutionSC.RATERESOLUTION#nThe resolution for the rate value; Select value: see Figure 4-8 on page 33
RatioSC.RATIO#nThe lever ratio for a pivoted weigh frame; Enter value: 0.0 - 9999.0, 1.0 (default)
RattleTrapSC.RATLTRAP#nEnables or disables the RattleTrap filter setting; Settings: ON, OFF (default)
Sensor DiameterSPEED.DIAMETER#nThe diameter of the speed sensor (in or m); Enter value: 0.01 - 100.0, 3.81972 (default)
Sample RateSC.SMPRAT#nAnalog-to-digital converter sample rate; Selects measurement rate, in samples per second, of
Span Error PercentSC.MCAL.SEp#nThe difference between the user entered amount and the monitored amount is calculated as a
Speed Cal Type
(no menu item)
Test DistanceSPEED.TESTDISTANCE#xThe user provided distance the belt traveled during a speed calibration (ft or m);
Test RevolutionsSPEED.TESTREVOLUTIONS#x The user provided number of revolutions the belt made during a speed calibration;
SC.DYNAMICSPANTYPE#nThe type of dynamic span calibration to be performed;
SC.RATEDAMPSECONDS#nThe number of seconds to average rate values; A value of 0 turns off the averaging;
SC.RATEDAMPSENS#nThe number of consecutive rate value calculations that must fall in or out of the threshold value
SC.RATEDAMPTHRESH#nThe rate threshold used with sensitivity to set where rate filtering is suspended/resumed;
SPEED.SPEEDCALTYPE#xThe type of calibration used to calculate belt speed;
specified number of consecutive scale readings (Filter Sensitivity parameter) fall outside of this
threshold, digital filtering is suspended; If NONE is selected, the filter is always enabled;
intervals between updates; Enter value: 1 - 80, 1 (default)
Settings: MATERIAL (default), CHAIN, TESTWEIGHT
calculates belt speed using the speed sensor (ft/m or m/s);
Enter value: 0.0 - 9999.0, 0.0 (default)
lb/ft) of the belt scale; For example: with a total loadcell build of 500lbs and a 4ft idler spacing
the max lb/ft value is 125; Settings: 0.01 - 9999.0, 48.0 (default)
Enter value: 0.0 - 9999.0, 0.0 (default)
can pass along the belt scale per hour (tn/h, lb/h, t/h or kg/h);
Enter value: 0.1 - 99999.0, 500.0 (default)
be subtracted from totalizers; Settings: YES (default), NO
Settings:
SINGLE (default) – speed is determined from a single sensor connected to pulse input 1
REDUNDANT – a single sensor going to both of the pulse inputs
DUAL – two sensors each going to an individual pulse input
Enter value: 0.0 - 99999.0, 60.0 (default)
Enter value: 0 - 1000, 250 (default)
Enter value: 0 - 600, 0 (default)
before rate filtering is suspended/resumed; Enter value: 0 - 400, 50 (default)
Enter value: 0 - 1000, 200 (default)
the analog-to-digital converter; Settings: 30HZ (default), 60HZ, 120HZ, 7.5HZ, 15HZ
percentage of the user entered amount; When a dynamic span calibration is performed the
stored percentage and the new percentage are shown to the operator who can then decide
whether or not to accept the calibration; Enter value: -999.0 - 999.0, 0.0 (default)
Test WeightSC.MCAL.TWp#nThe amount of test weight used for a test weight based dynamic span calibration (lb or kg);
Totalizer ResolutionSC.TOTALIZERRESOLUTION#n The resolution for the totalizer value; Select value: see Figure 4-8 on page 33
Total Loadcell BuildSC.TOTALLOADCELLBUILD#nTotal load cell capacity for all the load cells in system; e.g. in a system with 8 load cells, each
UnitsSC.UNITS#nSpecifies general units group used – either Metric or Imperial;
Warmup SC.WARMUP#nThe Warmup timeout is started once speed is detected at power up; If speed drops to 0 or
Zero Error PercentSC.ZEROERRORPERCENT#nPercentage of the configured scale capacity that was run across the scale during a dynamic
Zero BandSC.ZEROBAND#nThis is the range that is used to determine whether the weight is zero; Zero band represents a
Zero CountsSC.ZEROCOUNTS#nThis is the Zero (deadload) raw count value; This can be set manually or through calibration;
Zero RangeSC.ZRANGE#nThis is the total amount that can be zeroed off, either manually or summed with Auto Zero;
Enter value: 0.0 - 99999.0, 0.0 (default)
having a capacity of 100, the total capacity would be 800 (lb or kg);
Enter value: 0.0 - 99999.0, 500.0 (default)
Settings: IMPERIAL (default), METRIC
882D enters setup mode, the warmup timer stops; The warmup timer restarts once the speed
is above 0 and the 882D is in weigh mode; The parameter for warmup represents minutes, a
setting of 0.0 disables warmup; If the Rate or Load is being displayed while warmup is active:
• Message area displays "Warm Up"
• No annunciators are displayed
• Dashes fill numeric area
Modes other than Rate or Load display normally while warmup is active;
Enter value: 0.0 - 60.0, 0.0 (default)
zero calibration; When a dynamic zero calibration is performed the stored percentage and the
new percentage are displayed to the operator who can then decide whether or not to accept
the calibration; Enter value: -999.0 - 999.0, 0.0 (default)
percentage of Max Capacity; When weight is within the Zero Band, the Center of Zero (->0<-)
annunciator will be displayed; Zero Band cannot be set above 2% in legal for trade
applications; Enter value: 0.0 - 100.0, 0.0 (default)
Enter value: -2147483646 - 2147483647, 0 (default)
A value of 0.0 prevents any zeroing; Enter value: 0.0 - 100.0, 0.0 (default)
Table 7-9. Scales Commands (Continued)
NOTE: “n” at the end of a command represents the scale number.
“p” within a command represents the calibration point number.
“x” at the end of a command represents the pulse input number.
7.7.2Time and Date Menu
MenuCommandDescription
Time FormatTIMEFMTSpecifies whether time is in 12-hour or 24-hour format; Settings: 12HOUR (default), 24HOUR
Time SeparatorTIMESEPSpecifies the time separator; Settings: COLON (default), COMMA
Date FormatDATEFMT
Date SeparatorDATESEPSpecifies the date separator; Settings: SLASH (default), DASH, SEMI
Specifies the date format; Settings: MMDDY4 (default), DDMMY4, Y4MMDD, Y4DDMM, MMDDY2,
DDMMY2, Y2MMDD, Y2DDMM
Table 7-10. Time and Date Commands
7.7.3Passwords Menu
MenuCommandDescription
UserPWD.USERUsed to protect items in the top level menu; If value is zero, password is turned off; Enter value: 0 - 999999, 0 (default)
SetupPWD.SETUPUsed to protect items in the setup menu; If value is zero, password is turned off; Enter value: 0 - 999999, 0 (default)
Totalizer PWD.TOTALIZER
NOTE: The EDP commands can be used to set the passwords but they will not return the current password setting.
66Visit our website www.RiceLake.com
Used to protect Totalizers 1 and 2 from being cleared from the weigh mode; If value is zero, password is turned off;
Enter value: 0 - 999999, 0 (default)
Table 7-11. Password Commands
Page 67
EDP Commands
7.7.4Features Menu
MenuCommandDescription
Consecutive Number
Current Value
Consecutive Number
Reset Value
Decimal FormatDECFMTSpecifies whether decimal numbers are displayed using a period (DOT) or comma as the decimal
Unit IDUIDSpecifies the unit identification string; Alphanumeric, Max Length: 16, 1 (default)
CLR TOTAL 1 W/
PRINT
CLR TOTAL 2 W/
PRINT
AUDIT PRINT PORT AUDITPRINTPORTThe port that an audit report is transmitted out of;
CONSNUM
CONSTUPSpecifies the value used when the consecutive number is reset by sending the KCLRCN serial
CLEARTOTAL1WITHPRINT If YES, then the Totalizer 1 value is cleared when a print is performed; If NO, then the Totalizer 1
CLEARTOTAL2WITHPRINT If YES, then the Totalizer 2 value is cleared when a print is performed; If NO, then the Totalizer 2
Query or set the current consecutive number value; The consecutive number value is incremented
following each print operation that includes <CN> in ticket format; Enter value: 0 - 999999, 0 (default)
command or a CLRCN digital input; Settings: 0 - 999999, 0 (default)
symbol; Settings: DOT (default), COMMA
value is not cleared when a print is performed; Settings: NO (default), YES
value is not cleared when a print is performed; Settings: NO (default), YES
Settings: COM (default), USBCOM, ETH-C, ETH-S, OFF
Table 7-12. Features Commands
7.7.5Ports – COM Menu
MenuCommandDescription
BaudEDP.BAUD#1Port baud rate; Settings: 9600 (default), 19200, 28800, 38400, 57600, 115200, 1200, 2400, 4800
BitsEDP.BITS#1Port data bits and parity; Settings: 8NONE (default), 7EVEN, 7ODD
EchoEDP.ECHO#1Specifies whether characters received by the port are echoed back to the sending unit;
Settings: ON (default), OFF
End of Line DelayEDP.EOLDLY#1Port end-of-line delay in 0.1 second intervals; Enter value: 0-255, 0 (default)
TypeEDP.TYPE#1Specifies RS-232, RS-485 or RS-422 communications; If 485 is selected then the ADDRES parameter
is shown in the menu; Settings: 232 (default), 485, 422
Note: When changing between RS-232 and RS-485/RS-422, switch SW3, on the CPU board, must
also be changed; See Section 2.4.7 on page 16
AddressEDP.ADDRESS#1Specifies decimal indicator address for RS-485 connections; RS-485 addresses must be 01-255;
Enter value: 0-255, 0 (default)
Print MessageEDP.PRNMSG#1Displays a message when a print is transmitted; Settings: ON (default), OFF
ResponseEDP.RESPONSE#1Specifies whether the port transmits replies to serial commands; If an external device (such as a
printer) that may transmit unexpected data (such as a paper low message) is connected to the 882D
the response parameter should be set to OFF to prevent a reply from the 882D from confusing the
external device; Settings: ON (default), OFF
Stream FormatEDP.SFMT#1Specifies the stream format used for streaming output of scale data or specifies the expected input for
a serial scale; Alphanumeric, Max Length: 200, <R><NL> (default); See Section 12.4.1 on page 94
Stop BitsEDP.STOPBITS#1Selects the number of stop bits transmitted and the number of stop bits expected to be received by the
port; Settings: 1 (default), 2
TerminationEDP.TERMIN#1Selects the termination character(s) for data sent from the port; Settings: CR/LF (default), CR
TriggerEDP.TRIGGER#1Selects the operation of the port;
Settings:
COMAND (default) – allows operation of EDP commands and will print
STRLFT – stream legal for trade scale data; weight data in the stream frame is updated at the
configured display update rate; will also accept EDP commands; the 882D will not stream if port
type is set for 485
STRIND – stream industrial scale data; weight data in the stream frame is updated at the
configured sample rate; will also accept EDP commands; the 882D will not stream if port type is
set for 485
PROGIN – programmable input; for use with an iRite user program
EchoEDP.ECHO#2Specifies whether characters received by the port are echoed back to the sending unit;
Settings: ON (default), OFF
End of Line DelayEDP.EOLDLY#2Port end-of-line delay, in 0.1 second intervals; Enter value: 0-255, 0 (default)
Print MessageEDP.PRNMSG#2Displays print message; Settings: ON (default), OFF
ResponseEDP.RESPONSE#2Specifies whether the port transmits replies to serial commands; If an external device (such as a
printer) that may transmit unexpected data (such as a paper low message) is connected to the 882D,
the response parameter should be set to OFF to prevent a reply from the 882D from confusing the
external device; Settings: ON (default), OFF
Stream FormatEDP.SFMT#2Specifies the stream format used for streaming output of scale data (TRIGGE = STRLFT or STRIND);
Alphanumeric, Max Length: 200, <R><NL> (default); See Section 12.4.1 on page 94
TerminationEDP.TERMIN#2Selects the termination character(s) for data sent from the port; Settings: CR/LF (default), CR
TriggerEDP.TRIGGER#2Selects the operation of the port; Settings:
COMAND (default) – allows operation of EDP commands and prints
STRLFT – stream legal for trade scale data; weight data in the stream frame is updated at the
configured display update rate; also accepts EDP commands
STRIND – stream industrial scale data; weight data in the stream frame is updated at the
configured sample rate; also accepts EDP commands
PROGIN – programmable input; for use with an iRite user program
Table 7-14. PORTS – USBCOM Commands
7.7.7Ports – Ethernet Menu
MenuCommandDescription
Default Gateway
DHCP
DNS Primary
DNS Secondary
IP Address
MAC
Netmask
Client | Echo
Server | Echo
Client | End of Line Delay
Server | End of Line Delay
Client | Response
Server | Response
Client | Remote IP Address
Client | Remote Port
Client | Stream Format
Server | Stream Format
Client | Termination
Server | Termination
Client | Timeout
Server | Timeout
ETH.DEFAULTGATEWAY
ETH.DHCP
ETH.DNSPRIMARYPrimary DNS server IP address; Valid IP address, 000.000.000.000 (default)
ETH.DNSSECONDARY
ETH.IPADDRESS
ETH.MACADDRESS
ETH.NETMASK
ETH.CLIENT.ECHO
ETH.SERVER.ECHO
ETH.CLIENT.EOLDLY
ETH.SERVER.EOLDLY
ETH.CLIENT.RESPONSE
ETH.SERVER.RESPONSE
ETH.CLIENT.REMOTESERVERIP
ETH.CLIENT.REMOTESERVERPORT
ETH.CLIENT.SFMT
ETH.SERVER.SFMT
ETH.CLIENT.TERMIN
ETH.SERVER.TERMIN
ETH.CLIENT.TIMEOUT
ETH.SERVER.TIMEOUT
Default gateway; Valid IP address, 000.000.000.000 (default)
Dynamic Host Configuration Protocol; Settings: ON (default), OFF
Secondary DNS server IP address; Valid IP address, 000.000.000.000 (default)
IP address for the device; If DHCP is enabled this IP address is automatically set;
Valid IP address, 192.168.000.001 (default)
MAC address (read only); Settings: n/a – read only
Specifies the netmask; Valid IP address, 000.000.000.000 (default)
Specifies whether characters received by the port are echoed back to the sending
unit; Applies to EDP command operation; Settings: OFF (default), ON
Port end-of-line delay, in 0.1 second intervals;
Enter value: 0-255, 0 (default)
Specifies whether the port transmits replies to serial commands; If an external
device (such as a printer) that may transmit unexpected data (such as a paper low
message) is connected to the 882D, the response parameter should be set to OFF
to prevent a reply from the 882D from confusing the external device;
Settings: ON (default), OFF
Remote IP address of the remote machine that the 882D will connect to;
Valid IP address, 000.000.000.000 (default)
Remote port number of the remote machine that the 882D will connect to;
Enter value: 1-65535, 1 (default)
Specifies the stream format used for streaming output of scale data
(TRIGGE=STRLFT or STRIND); Alphanumeric, Max Length: 200, <R><NL> (default);
See
Section 12.4.1 on page 94
Selects the termination character(s) for data sent from the port;
Settings: CR/LF (default), CR
Inactivity disconnect timeout; Connection is closed after a specified period
(in seconds) of inactivity; Setting the value to 0 disables the parameter;
Enter value: 0 - 65535, 0 (default)
Table 7-15. PORTS – Ethernet Commands
68Visit our websitewww.RiceLake.com
Page 69
EDP Commands
MenuCommandDescription
Client | Trigger
Server | Trigger
Server | Port
ETH.CLIENT.TRIGGER
ETH.SERVER.TRIGGER
ETH.SERVER.PORT
Selects the operation of the port; Settings:
COMAND (default) – allows operation of EDP commands and prints
STRLFT – stream legal for trade scale data; weight data in the stream frame is
updated at the configured display update rate; also accepts EDP commands
STRIND – stream industrial scale data; weight data in the stream frame is
updated at the configured sample rate; also accepts EDP commands
PROGIN – programmable input, for use with an iRite user program
Port that the 882D uses for its server; Enter value: 1 - 65535, 10001 (default)
Table 7-15. PORTS – Ethernet Commands (Continued)
7.7.8Ports – Fieldbus Menu
MenuCommandDescription
SwapFB.BYTESWAP#n
Address (DeviceNet)FB.DEVICENETADDRESS#nSpecifies the DeviceNet address; Enter value: 1 - 64, 63 (default)
Address (Profibus)FB.PROFIBUSADDRESS#nSpecifies the Profibus address; Enter value: 1 - 126, 126 (default)
SizeFB.SIZE#nSpecifies the data size, in bytes, that the BusCommand handler transfers; If this parameter
Table 7-16. PORTS – Fieldbus Commands
Specifies byte-swapping used for the fieldbus card; Settings: NONE (default), BYTE, BOTH
is set to a value other than the default (8 bytes), ensure that it matches the Scanner I/O
data size specified for the PLC; Enter value: 2 - 128, 8 (default)
7.7.9Keypad Lock Menu
MenuCommandDescription
CLRKEYLCK.CLRLocks or unlocks the Clear key; Settings UNLOCK (default), LOCK
DOTKEYLCK.DOTLocks or unlocks the Dot key; Settings UNLOCK (default), LOCK
F1KEYLCK.F1Locks or unlocks the F1 key; Settings UNLOCK (default), LOCK
F2KEYLCK.F2Locks or unlocks the F2 key; Settings UNLOCK (default), LOCK
F3KEYLCK.F3Locks or unlocks the F3 key; Settings UNLOCK (default), LOCK
F4KEYLCK.F4Locks or unlocks the F4 key; Settings UNLOCK (default), LOCK
MODEKEYLCK.MODELocks or unlocks the Mode key; Settings UNLOCK (default), LOCK
MENUKEYLCK.MENULocks or unlocks the Menu key; Settings UNLOCK (default), LOCK
NUMKEYLCK.NUMLocks or unlocks the Numeric keys; Settings UNLOCK (default), LOCK
PRINTKEYLCK.PRINTLocks or unlocks the Print key; Settings UNLOCK (default), LOCK
SETPOINTKEYLCK.SETPOINTLocks or unlocks the Setpoint key; Settings UNLOCK (default), LOCK
ZEROKEYLCK.ZEROLocks or unlocks the Zero key; Settings UNLOCK (default), LOCK
Table 7-17. Keypad Lock Commands
7.7.10 Setpoints Menu
MenuCommandDescription
AccessSP.ACCESS#nSpecifies the access allowed to setpoint parameters shown by navigating to the top level SETPT menu;
Settings:
OFF (default) – values can be displayed but not changed
ON – values can be displayed and changed
Batch SequenceSP.BATSEQ#n
Digital OutputSP.DIGOUT#nThis parameter is used to specify the digital output bit associated with this setpoint; Use the DIGIO menu to
Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint; Settings: OFF (default), ON
assign bit function to OUTPUT, only bits set as OUTPUT can be assigned to a setpoint; For continuous
setpoints, the digital output becomes active (low) when the condition is met; for batch setpoints, the digital output
is active until the setpoint condition is met; Settings: BIT1 (default), BIT2 - BIT24
Enable*SP.ENABLE#nEnables (ON) or disables (OFF) the setpoints; Settings: ON (default), OFF
NOTE: The Enable menu item is only available in the top level setpoint menu
Selection made
directly after
dropping down
from SETPT x
NameSP.NAME#nSetpoint name string; Alphanumeric, Max Length: 6, “blank” (default)
PreactSP.PREACT#nAllows the digital output associated with a setpoint to shut off before the setpoint is satisfied to allow for material
Preact ValueSP.PREVAL#nSpecifies preact value for setpoints with PREACT set to ON or LEARN; depending on the TRIP setting specified
Push PrintSP.PSHPRINT#nSpecifies which print format to transmit or none; Settings: NONE (default), PRINT FORMAT 1 - 4
SenseSP.SENSE#nSpecifies whether the value of the digital output associated with this setpoint is inverted when the setpoint is
SlotSP.DSLOT#nLists all available digital I/O slots; this parameter specifies the slot number of the digital I/O card referenced by
SourceSP.SOURCE#nThe source for a TOTAL setpoint type; Settings: TOTALIZER 1 (default), TOTALIZER 2, MASTER
TripSP.TRIP#nSpecifies whether the setpoint is satisfied when the weight is higher or lower than the setpoint value; Settings:
ValueSP.VALUE#nSetpoint value; for time-based setpoints: specifies, in 0.1 second intervals, a time value; for all other setpoints:
BatchingBATCHNGSet to MANUAL to allow a batch sequence to run; MANUAL requires a BATSTR digital input or BATSTART
SP.KIND#nSupported setpoint kinds; Settings:
OFF (default) – setpoint turned off/ignored
RATE – rate setpoint; performs functions based on the current rate
%RATE – percent rate setpoint; performs functions based on a specified percentage of configured
Max Capacity
LOAD – load setpoint; performs functions based on current load
SPEED – speed setpoint; performs functions based on current belt speed
TOTAL – totalizer setpoint; performs functions based on totalizer value
CELLMV – load cell millivolt setpoint; performs functions based on current cell mV reading
PAUSE –
DELAY – delays batch sequence for a specified time; the length of the delay (in tenths of a second) is
specified on the VALUE parameter
in suspension; Settings:
OFF (default) – disables the preact
ON – adjusts setpoint trip value up or down (depending on the TRIP parameter setting) from the setpoint
value using a fixed value specified on the PREVAL parameter; weight based,
e.g. a value of 2 = turn off 2 tons early
LEARN – monitors the load amount on the specified distance of belt and adjusts the setpoint trip value up
or down (depending on the TRIP parameter setting); for example a value of 15 ft (and a current load of
20 lb/ft) will turn off 0.08 tons early; 20 lb x 15 ft = 300 lb, 300 lb = 0.08 tons
for the setpoint, the setpoint trip value is adjusted up or down by the PREVAL value;
Enter value: 0-999999, 0 (default)
satisfied; Settings NORMAL (default), INVERTED
the DIGOUT parameter; Settings:
NONE (default) – specifies no digital output being used by the setpoint
SLOT0 –
SLOT1 –
SLOT2 –
HIGHER (default) – the associated digital output is active until the setpoint value is reached or exceeded
LOWER – the associated digital output is active until the current value goes below the setpoint value
NOTE: For continuous setpoints, the digital output logic above is just the opposite
specifies the target value; Enter value: 0 - 65535 (for the DELAY setpoint), 0 - 999999 (for the RATE, %RATE,
serial command before the batch sequence can run; Settings: OFF (default), MANUAL
pauses batch sequence indefinitely; a BATSTRT signal must be initiated to continue batch process
onboard digital outputs; only shown if card is installed and at least one bit is configured as OUTPUT
digital I/O option card; only shown if card is installed and at least one bit is configured as OUTPUT
digital I/O option card; only shown if card is installed and at least one bit is configured as OUTPUT
Table 7-18. Setpoints Commands (Continued)
NOTE: “n” represents the setpoint number (1-20) for setpoint commands.
Different setpoint parameters are available and accepted depending on KIND, TRIP, and PREACT. These restrictions are
listed below by the EDP command name but the same applies to access by menu.
70Visit our websitewww.RiceLake.com
Page 71
EDP Commands
RATE, %RATE, LOAD, SPEED, TOTAL, CELLMV type setpoints
SP.KIND#n=RATE, %RATE, LOAD, SPEED, TOTAL, CELLMV
SP.ACCESS#n
SP.BATSEQ#n
SP.DIGOUT#n
SP.ENABLE#n(EDP command is always available, menu item
is only available in the top level menu)
SP.NAME#n
SP.PREACT#n(if KIND is TOTAL)
SP.PREVAL#n(if PREACT is ON or LEARN only)
SP.PSHPRT#n
SP.SENSE#n
SP.SLOT#n
SP.SOURCE#n(if KIND is TOTAL)
SP.TRIP#n
SP.VALUE#n
PAUSE type setpoints
SP.KIND#n=PAUSE
SP.ACCESS#n
SP.DIGOUT#n
SP.ENABLE#n(EDP command is always available, menu item
is only available in the top level menu)
SP.NAME#n
SP.SENSE#n
SP.SLOT#n
DELAY type setpoints
SP.KIND#n=DELAY and AUTJOG
SP.ACCESS#n
SP.CLRACM#n
SP.CLRTAR#n
SP.DIGOUT#n
SP.ENABLE#n(EDP command is always available, menu item
is only available in the top level menu)
SP.NAME#n
SP.PSHPRT#n
SP.SENSE#n
SP.SLOT#n
SP.VALUE#n
7.7.11 Print Format Menu
The menu items are listed by the format and the sub-parameters.
• A press of Print (in run mode) prints Print Format 1. Entering a value and then pressing print will print the corresponding
print format (2 + Print = Print Format 2).
• A setpoint Push Print can be configured to print any of the listed formats.
MenuCommandDescription
Print Format x | FormatPFMTx.FMTAlphanumeric, Max Length: 1000; Default: TIME: <TI><NL>DATE: <DA><NL>
Print Format x | Port | COMPFMTx.PORT.COMSettings: ON (default), OFF
Print Format x | Port | USBCOM PFMTx.PORT.USBCOM Settings: OFF (default), ON
Print Format x | Port | ETH-SPFMTx.PORT.ETH-SSettings: OFF (default), ON
Print Format x | Port | ETH-CPFMTx.PORT.ETH-CSettings: OFF (default), ON
Table 7-19. Print Format Commands
NOTE: “x” represents the print format number (1-4).
See Section 8.0 on page 77 for detailed information on print formatting.
BIT xDIO.b#sOFF (default) – the digital I/O has no assigned function
BATRUN – allows a batch routine to be started and run; with BATRUN active (low), the BATSTRT input starts the batch;
if BATRUN is inactive (high), BATSTRT resets the batch
BATSTR – starts or resets a batch routine, depending on the state of the BATRUN input
BATPAS – pauses a batch routine
BATRST – stops the batch sequence and resets to the first batch step
BATSTP – stops a batch routine
CLEAR – provides the same function as the front panel key
CLRCN – resets the consecutive number to the value specified on the CONSTUP parameter
CLRTOT1 – clears the Totalizer 1 value
CLRTOT2 – clears the Totalizer 2 value
BELTRUNNING – indicates whether or not the belt is running and whether to enable or disable totalization; input low =
belt is running, enable the totalization; input high = belt is not running, disable the totalization; when this input indicates
that the belt is not running, force the speed reading to zero regardless of speed input; if no digital input is configured as
BELTRUNNING then the belt is determined to be moving or not moving based on whether or not pulses are being
received from the speed sensor; only one BELTRUNNING input will be recognized; e.g. if both bit 3 and bit 4 are
configured as BELTRUNNING then only the first one (bit 3) is used by the system
INPUT – assigns the bit as a digital input used for the iRite GetDigin API
KBDLOC – locks all the front panel keys while this input is held active
MODE – provides the same function as the front panel key
OUTPUT – assigns the bit as a digital output for setpoint or iRite program use
PRINT – provides the same function as the front panel key
PROGIN – assigns the bit as a digital input used to generate an iRite program event
TOTALIZERPULSE – an output that pulses to indicate total material weighed
ZERO – provides the same function as the front panel key
Table 7-20. Digital I/O Configuration Commands
NOTE: Digital I/O are specified by bit number (b) and slot number (s).
72Visit our websitewww.RiceLake.com
Page 73
EDP Commands
7.7.13 Database Commands
The commands listed in Table 7-21 can be used to create and maintain databases in the 882D. Except for the DB.DELALL
command, all of the database commands require an extension to identify the database number.
CommandDescription
DB.ALIAS.n#xGet or set database name
DB.CLEAR.n#xClear database contents
DB.DATA.n#xGet or set database contents
DB.SCHEMA.n#xGet or set database structure
DB.DELALLDelete all databases and database contents
• n represents the database number, x is 0
• Each command must be terminated with a carriage return
character (<CR>, ASCII 13)
• The 882D only supports onboard databases - slot 0
• Onboard database number 1 is reserved for future use on the
882D; database numbers 2-9 are available
Table 7-21. Database Commands
DB.ALIAS
The DB.ALIAS command is used to get or set the alias used by iRite programs to reference the specified database. Each
database alias must be unique among all databases and adhere to the following rules: 8 character maximum; must begin with
an alpha character or an underscore; can only contain A–Z, a–z, 0–9, or an underscore (_).
Example. The following command assigns an alias of TRUCKS_2 to the second database in the onboard memory:
DB.ALIAS.2#0=TRUCKS_2<CR>
Sending the DB.ALIAS command alone, without assigned data, returns the current database alias.
DB.CLEAR
To clear the contents of a database, send the following command:
DB.CLEAR.n#x<CR>
Where:
is the database number within the memory
n
x is the slot number 0
The 882D responds with OK<CR> if the command is successful,??<CR> if unsuccessful.
The DB.DATA command can be used to send data to or retrieve data from the 882D.
Data can be sent to the 882D using the following command:
DB.DATA.n#x = data{ | }<CR>
Where:
is the database number within the memory
n
x is the slot number 0
data represents a single cell of a row of data
{ | } is an ASCII pipe character (decimal 124), used to delimit cell data. If the data being sent is not the last cell of the row, append the
pipe character to the data to indicate that more data is coming for that particular row. If the data being sent is the last cell of the row, do
not append the pipe character.
If the command is accepted, the 882D responds with OK<CR>; if not, it responds with ??<CR>.Example: The following commands place the data shown in Table 7-22 into the second database in the onboard memory:
Sending the DB.DATA command alone, without assigned data, returns the database contents:
DB.DATA.n#x<CR>
The 882D responds with the entire contents of the database. Returned data is cell-delimited with the pipe character (decimal
124) and row-delimited with carriage returns (decimal 13).
For example, the following command could be used to return the contents of database 2 in the onboard memory:
DB.DATA.2#0<CR>
If the database contents are the records shown in Table 7-22, the 882D responds with the following data, using pipe characters
and carriage returns to delimit the database cells and rows, respectively:
this|is|a|test<CR>aaa|bbb|ccc|ddd<CR>
NOTE: There is not an end of database notification at the end of the DB.DATA command
out to determine command completion. The time-out value will vary based on baud rate.
transmission. Use a receive time-
Determine the number of records currently in the database both prior to and after sending the DB.DATA command to verify that
the correct number of records are received. The number of records can be determined with the DB.SCHEMA command.
NOTE: The 62K of onboard (slot 0) memory can be allocated to up to eight auxiliary databases; however, the size of any one
database may limit the size and number of other databases.
74Visit our websitewww.RiceLake.com
Page 75
EDP Commands
DB.SCHEMA
The DB.SCHEMA command is used to get or set the structure of a database.
DB.SCHEMA.n#x<CR>
The 882D responds to the command by returning the following:
<Max Records>,<Current Record Count>,
<Column Name>,<Data Type>,<Data Size>,...<CR>
The <Column Name>, <Data Type>, and <Data Size> elements repeat for each column in the database.
The <Column Name> follows the rules for alias names: 8 character maximum; must begin with an alpha character or an underscore;
can only contain A–Z, a–z, 0–9, or an underscore (_).
The <Data Type> is represented by a numeric field:
The <Data Size> value must match the data type. A range of data size values is allowed only for the string data types. The
maximum number of characters allowed for the string field are listed below.
SizeValue
Byte1
Short2
Long4
Single4
Double8
Fixed string1–255
Variable string1–255
Date and time8
Table 7-24. Data Size Field Codes
The DB.SCHEMA command can also be used to modify the schema, but only when the 882D is in setup mode and only if the
database does not contain any data.
SourceALG.SOURCE#sSpecifies the source of the analog output control; Settings:
SCALE (default) indicates that the analog output will follow the configured Mode based on
scale data
PROG indicates that the analog output is under iRite program control
ModeALG.MODE#sSpecifies the data tracked by the analog output; source must be configured for SCALE for the
analog output to follow any of these modes; Settings: RATE (default), SPEED, LOAD
OutputALG.OUTPUT#sSpecifies the output type; this parameter must be set before calibrating the analog output;
Settings: 0-10 V (default), 0-20 mA, 4-20 mA
Error ActionALG.ERRACT#sSpecifies how the analog output responds to system error conditions; Settings:
FULLSC (default) set to full value (10 V or 20 mA)
HOLD current value
ZEROSC set to zero value (0 V, 0 mA or 4 mA)
MinimumALG.MIN#s
MaximumALG.MAX#s
NOTE: “s” at the end of a command represents the slot number.
“n” at the end of the commands in the above table represent the channel for the analog output.
The 882D supports up to two single-channel analog output cards. An analog output card in slot 1 is referenced as analog output 1. An
analog output card in slot 2 is referenced as analog output 3.
Settings from either analog output 1 or 3 will be accepted whether or not an analog output option card is installed in either slot.
Specifies the minimum value tracked by the analog output; Enter value: 0 - 999999, 0 (default)
Specifies the maximum value tracked by the analog output; Enter value: 0 - 999999, 10000 (default)
Table 7-25. ALGOUT Commands
7.7.15 Digital Output Control Commands
CommandFunction
DON.b#sSet digital output on (active) at bit b, slot s
DOFF.b#sSet digital output off (inactive) at bit b, slot s
Table 7-26. Digital Output Control Commands
NOTE: Digital outputs are specified by bit number (b = 1-4 for slot 0, 1-24 for slots 1 and 2) and slot number (s = 0-2).
The DON/DOFF commands only control the state of a slot/bit that is defined as an OUTPUT in the configuration menu.
76Visit our websitewww.RiceLake.com
Page 77
Print Formatting
8.0Print Formatting
The 882D provides four print formats. A press of the Print key in run mode prints Print Format 1. Entering a value and then
pressing print, prints the corresponding print format (2 + Print = Print Format 2).
Each print format can be customized to include up to 1000 characters. Use the 882D front panel (PFORMT menu), EDP
commands, or the Revolution configuration utility to customize the print formats.
NOTE: The 882D only prints when not totalizing.
Each ticket printed includes a hard coded header that contains the Previous Zero Error Percent, the Current Error Percent,
and the Current Master Total.
8.1Print Formatting Tokens
Table 8-1 lists tokens that can be used to format the 882D print formats. Tokens included in the format strings must be enclosed
in < > delimiters. Any characters outside of the delimiters are printed as text. Text characters can include any ASCII character
that can be printed by the output device. See Section 12.3 on page 92.
TokenDescription
<R>The current rate with units included
<S>The current speed with units included
<L>The current load with units included
<MT>Master Totalizer value – without units
<T1>Totalizer 1 value – without units
<T2>Totalizer 2 value – without units
<TU>Totalizer units
<DT1>Date of the last Totalizer 1 clear
<TT1>Time of the last Totalizer 1 clear
<DT2>Date of the last Totalizer 2 clear
<TT2>Time of the last Totalizer 2 clear
<LPV1>The last printed Totalizer 1 value
<LPV2>The last printed Totalizer 2 value
<LPVM>The last printed Master Totalizer value
<DCL1>The difference between the current and the last printed Totalizer 1 value
<DCL2>The difference between the current and the last printed Totalizer 1 value
<DCLM>The difference between the current and the last printed Master Totalizer value
<SN>Setpoint number; Valid when printed from a setpoint Push Print
<SNA>Setpoint name; Valid when printed from a setpoint Push Print
<SPV>Setpoint preact value; Valid when printed from a setpoint Push Print
<STV>Setpoint target value; Valid when printed from a setpoint Push Print
<UID>Unit ID number; Unit ID field is 1-16 characters in length, as required
<CN>Consecutive number; Consecutive number (CN) field is 1-6 characters in length, as required
<TI>Time
<DA>Date
<TD>Time & Date
<PFMT1> -
<PFMT4>
<CR>Carriage return character – hexadecimal 0x0D
Allows a print format to be used from another print format
NOTE: A print format will ignore a token that would print itself
Example: PFMT1.FMT=<R><PFMT1><CR> would literally print
<PFMT1> when that token was encountered
<LF>Line feed character – hexadecimal 0x0A
<FF>Form feed character – hexadecimal 0x0C
<NLnn>New line (nn = number of termination (<CR/LF> or <CR>) characters); If nn is not specified, 1 is assumed;
Value must be in the range 1–99
<SPnn>Space (nn = number of spaces); If nn is not specified, 1 is assumed; Value must be in the range 1–99
<SU>Toggle weight data format (formatted/unformatted); After receiving an SU command, the 882D sends
unformatted data until the next SU command is received; Unformatted data omits decimal points, leading
and trailing characters
<WU>Toggle weight data format (formatted/unformatted); After receiving a WU command, the 882D sends data
without a units label until the next WU command is received; Unformatted data omits the units label
<USnn>Insert user print text string (from iRite user program, SetPrintText API)
<EVx>Invoke iRite user program print handler x (PrintFmtx); Range of x is 1-10
<nnn>ASCII character (nnn = decimal value of ASCII character); Used for inserting control characters (STX, for
example) in the print stream
Table 8-1. Print Tokens (Continued)
NOTE: Rate, speed, load, and totalizer values are 8 digits in length, including sign and decimal point, followed by a space
and a one- to five-digit units identifier. Total field length with units identifier is 10-14 characters. Depending on the value and
which units are configured (METRIC or IMPERIAL), the units identifier will be lb, kg, tn, t, lb/ft, m/s, etc.
8.2Default Print Formats
Table 8-2 shows the default print formats for the 882D.
FormatDefault Format String
Print Format 1-4TIME: <TI><NL>DATE: <DA><NL> MASTER TOTAL: <MT><NL>TOTAL: <T1><NL>RATE: <R><NL>
NOTE: If the COM port is set to TYPE = RS485, the port will not perform a demand print. See Section 12.4.4 on page 95.
Table 8-2. Default Print Formats
78Visit our websitewww.RiceLake.com
Page 79
Print Formatting
8.3Customizing Print Formats
The following sections describe procedures for customizing print formats using the EDP commands, the front panel (PFORMT
menu), and the Revolution configuration utility.
8.3.1Using the EDP Commands
The EDP command set can be used to customize the print format strings when a personal computer, terminal or remote
keyboard are attached to the 882D.
To view the current setting of a format string, type the name of the print format, followed by .FMT, and press
example, to check the current configuration of the PFMT1 format, type PFMT1.FMT and press
ENTER. The 882D responds by
sending the current configuration for the print format:
To change the format, put the 882D into setup mode and use the format EDP command followed by an equals sign (=) and the
modified print format string.
For example, to add the name and address of a company to the print format, send the following EDP command:
PFMT1.FMT=RICE LAKE WEIGHING SYSTEMS<NL>230 W COLEMAN ST<NL>RICE LAKE WI 54868<NL2><T1> TOTAL<NL>
A ticket printed using this format might look like the following:
RICE LAKE WEIGHING SYSTEMS
230 W COLEMAN ST
RICE LAKE WI 54868
ENTER. For
1345 T TOTAL
8.3.2Using the Front Panel
If there is no access to equipment for communication through the communication ports or when working at a site where such
equipment cannot be used, the Print Format menu (Section 4.6.4 on page 39) can be used to customize the print formats.
Using the Print Format menu, edit the print format strings by changing the decimal values of the ASCII characters in the format
string.
Edit the format using the Alphanumeric Entry Procedure. See Section 4.3 on page 28.
NOTE: Some special characters cannot be displayed on the 882D front panel and are displayed as blanks. See the ASCII
character chart on page 92. The 882D can send or receive any ASCII character; the character printed depends on the
particular ASCII character set implemented for the receiving device.
The 882D supports two simultaneous TCP connections, one as a server and the other as a client. This section details the
functions of the Server and Client connections, including some examples on how they may be used. Refer to Section 4.6.3 on
page 37 for configuration.
Ethernet Server
The Server features a configurable TCP Port number. It also has settings for echo, response, End-of-Line delay, trigger function,
timeout and stream data format.
A typical application may connect a PC Application (a terminal program such as Telnet, or Revolution) to the 882D.
The 882D listens for a connection request from an external client device.
Ethernet Client
The Client features the ability to open a TCP connection to a configurable Remote Server IP and TCP Port.
If a connection has not been made and the 882D attempts to send data through the client connection, it attempts to establish a
connection to the remote server. It continues trying indefinitely until a connection is made.
Typical applications for the Client include connecting to:
• Ethernet printer or Remote Display
• Remote TCP to Serial device server
• PC application that is listening for the connection
The Client also has settings for echo, response, End-of- Line delay, trigger function, timeout, and stream data format.
Only a single connection each to the Server and Client is allowed at one time. If a connection is already established, other
connection attempts fail.
• The Server and Client ports are independent of each other and both can have a connection at the same time. This
means it can be streaming out one port, while using a PC to poll data from the other. Data can be streamed out both
ports if desired. IMPORTANT: For best results, set the End-of-Line Delay on both ports to at least 2.
• Establishing connections - a client must establish a connection to a server. Therefore, the 882D cannot connect to a
Remote Client, and a Remote Server cannot connect to the 882D.
• Both the Server and Client connections have a Timeout parameter, allowing the 882D to terminate either connection
after the set number of seconds has passed with no activity (0 = no disconnect).
• When connecting to a DHCP network, it may take several seconds before the 882D is assigned an IP address. When a
new IP address is assigned through DHCP, it is stored in the 882D configuration and remains the IP address until
reconfigured manually; the indicator settings are reset to default; or a new address is assigned by DHCP.
9.1.1Direct Connection from a PC to the 882D Ethernet Server without a network (Ad-Hoc)
1.Use the computer’s network configuration tools to
2.The 882D must also be configured with a static IP address,
3.Enter the configuration mode using the setup switch on the
4.Navigate to the Ethernet sub-menu under the Ports menu
5.Set Dynamic Host Configuration Protocal (DHCP
80Visit our website www.RiceLake.com
configure the network adapter to have a static IP address
and appropriate Netmask. The PC must be configured with
a static IP address. For example: 192.168.0.100.
different from the computer’s, but in the same Netmask.
bottom of the 882D (Figure 4-1 on page 27).
(Section 4.6.3 on page 37).
) to OFF and then configure the IP address and Netmask. Also set
the Server Ethernet TCP Port number, if needed (default is 10001).
Figure 9-1. Direct Connection from
PC to 882D Ethernet
Page 81
6.Connect an Ethernet straight-through or crossover cable (the port is auto-sensing, so either will work) between the
PC Client
IP: 192.168.0.100
TCP Terminal Program
882D Server
IP: 192.168.0.110
Server Port: 10001
Network
Switch
882D and the Ethernet connector on the PC.
7.Open the PC application.
8.Enter the indicator’s IP address and Server TCP Port number (192.168.0.110 and 10001 in this example) to establish
the connection. The application now can communicate with the 882D using any of its EDP commands.
9.1.2PC Connection to the 882D Ethernet Server Through a Network Switch or Router
NOTE: In some cases, devices cannot be connected to an existing network without the network administrator’s approval.
Ensure there is permission to connect to the network and seek help from the network administrator as needed.
1.Ensure the PC is connected to the network, and either
assigned an IP address using DHCP, or have a static
address.
• If not, use the computer’s network configuration tools to
connect to the network.
• If it is not a DHCP network, make note of the PC’s IP
Address and Netmask.
2.Enter the configuration mode using the setup switch on the
bottom of the unit (Figure 4-1 on page 27).
3.Navigate to the Ethernet sub-menu under the Ports menu
(Section 4.6.3 on page 37).
4.Manually configure the 882D with a static IP address
(recommended) or obtain its IP address using a DHCP
(if supported on the network). Rice Lake Weighing Systems
does not recommended using a DHCP because the scale IP address can change and communication will be lost.
- Dynamic Host Configuration Protocal (DHCP): Set the DHCP Setting to ON. Set the Ethernet Server Port to the
desired Port number (default is 10001). The IP, Netmask, Primary and Secondary DNS, and Default Gateway will
be configured automatically when the 882D is connected to the DHCP-enabled network.
- Manual (static) IP Address: Set DHCP to OFF. Configure the IP Address and Netmask. Also set the Ethernet
Server Port number, if needed (default is 10001). Set the Primary and Secondary DNS, and Default Gateway, if
needed.
5.Connect the Ethernet connector on the 882D to an available connector on the network using a straight-through or
crossover cable (the port is auto-sensing, so either will work).
6.If connected to a DHCP-enabled network and DHCP is enabled, go back into the configuration mode and navigate to
the IP setting to get the IP address the network assigned to the 882D. Make note of the current IP address, being
careful not to change any of the numbers. Return to weigh mode.
7.Open the PC application to be used. To establish the connection, enter the indicator’s IP address and Server TCP Port
number (192.168.0.110 - or the DHCP-assigned IP address - and 10001 in this example). The application will now be
able to communicate to the 882D using any of its EDP commands.
9.1.3Connection to a Remote Server - Demand Print to an Ethernet Printer
1.Connect the 882D and printer directly to each other (each
with a Static IP on the same Netmask) or through a
network.
2.Configure the Client Remote Server IP and port to the IP
address and TCP port of the printer.
3.Configure the port destination of the Print Format(s) being
used to Ethernet Client (ETH-C).
4.Set the Ethernet Client Trigger to Command (COMAND)
mode.
5.The Client attempts to connect to the printer if the client
has not been connected and a demand print is called for.
This may take several seconds. The print data will be
sent to the printer once the connection is made.
6.The connection remains intact unless the 882D or the printer terminates the connection.
The 882D has a timeout setting for the Client connection.
• When set to 0, the connection is not terminated by the 882D.
• When set to a value other than zero, the connection is terminated after inactivity for the specified period of time, in
seconds.
The timeout feature is useful when several indicators want to print to the same printer.
Figure 9-3. Connection to Remote Host
9.1.4Connecting to a Remote Server - Stream weight data to an Ethernet Remote Display
1.Connect the 882D and Remote Display directly to each
other (each with a Static IP on the same Netmask) or
through a network.
2.Configure the Client Remote Server IP and port to the IP
address and TCP port of the remote display.
3.Configure the trigger setting for the Client to either Stream
Industrial (STRIND), or Stream Legal-for-Trade (STRLFT).
4.Rice Lake Weighing Systems recommends that the
Client’s End-of-Line Delay be set to 1 (10 frames per
second) or 2 (5 frames per second) or higher to
prevent data overrun on the receiving device (the 882D
streams data at up to 50 frames per second). This is also
a good way to help reduce network traffic if speed is not a
concern. If data at the remote display appears to lag, or get behind the data on the indicator, the End-of-Line Delay
may need to be increased even more.
5.The 882D starts to stream data to the Ethernet Client port shortly after returning to the weigh mode. The 882D then
attempts to make the connection and data is sent to the Remote Host once connected. This may take several
seconds.
Figure 9-4. Connection to Remote Host to Stream
82Visit our websitewww.RiceLake.com
Page 83
Ethernet
Ethernet to RS-232
Device Server
IP: 192.168.0.30
TCP Port: 10001
Serial Device
such as a Printer,
Remote Display,
or Serial Scale in
an Indicator
RS-232
9.1.5Connecting to a Remote Server, Stream/Demand Data to Remote Ethernet-to-RS-232 Device Server
1.Connect the 882D and device server
directly to each other (each with a
static IP on the same netmask) or
through a network.
2.Configure the Client Remote Server IP
and port to the IP address and TCP
port of the device server.
3.Configure the trigger setting for the
client to either command mode
(COMAND), stream industrial
(STRIND), or stream Legal-for-Trade
(STRLFT), depending on the
application.
4.Connect the serial output of the device
server to the serial device set to send or
receive data through the Ethernet connection.
NOTE: In this configuration, the 882D has to initiate the connection
Using Revolution with Ethernet
1.Use one of the methods shown in Section 6.1 on page 55 to connect the 882D to the PC with Revolution installed.
2.In Revolution, after opening the 882D module, select Tools, then Options.
3.Set the default communications to TCP/IP and click OK.
4.Under the Communications menu, select Connect.
5.Revolution requests the IP address and port number. Enter them and click OK.
6.Revolution attempts to establish communications with the indicator. If the connection is successful, Revolution is ready
for use to upload and download configuration settings.
NOTE: When using Revolution with Ethernet, the Timeout setting for the 882D Ethernet Server must be set to 0 to prevent
the 882D from terminating the connection.
Figure 9-5. Stream or Demand Data to a Remote Ethernet
to RS232 Device Server
If the connection was unsuccessful, re-check all network settings on the computer and in the 882D. Attempt to ping the IP
address of the 882D to verify the computer and 882D are both able to communicate on the network.
The 882D provides 20 configurable setpoints for control of both 882D and external equipment functions. Setpoints can be
configured to perform actions or functions based on specified parameter conditions. Parameters associated with various
setpoint kinds can, for example, be configured to perform functions (print and total), to change the state of a digital output to
control external equipment functions, or to make conditional decisions.
NOTE: See Section 4.6.5 on page 40 for setpoint menu layout.
10.1Batch and Continuous Setpoints
882D setpoints can be either continuous or batch setpoints.
Continuous setpoints are free-running; the 882D constantly monitors the condition of free-running setpoints at each A/D update.
The specified setpoint action or function is performed when the designated setpoint parameter conditions are met. A digital
output or function assigned to a free-running setpoint continuously changes state, becoming active or inactive, as defined by
the setpoint parameters.
Batch setpoints are active one at a time, in an ordered sequence. The 882D can use setpoints to control up to 20 separate
batch processing steps.
• A digital output associated with a batch setpoint is active until the setpoint condition is met, then latched in an inactive
state for the remainder of the batch sequence.
• To use batch setpoints, the Batching parameter in the Setpoints menu must be set to MANUAL. Batch sequences
require a Batch Start signal each time a batch is run. The BATSTR signal can be initiated by a digital input, serial
command, or the StartBatch function in an iRite program.
• For setpoint kinds that can be used as either continuous or batch setpoints, the Batch Sequence parameter must also be
set ON. (Setpoint kinds that can only be used as batch setpoints do not require the Batch Sequence parameter.) If
setpoint is defined but Batch Sequence parameter is OFF, the setpoint operates as a continuous setpoint, even during
batch sequences.
KindDescriptionBatch Continuous
OFFSetpoint turned off/ignored.XX
RATERate setpoint. Performs functions based on the current rate.XX
%RATE
LOADLoad setpoint. Performs functions based on the current load.XX
SPEEDSpeed setpoint. Performs functions based on the belt speed.XX
TOTALTotalizer setpoint. Performs functions based on the totalizer value.XX
CELLMVLoad cell millivolt setpoint. Performs functions based on the current cell mV reading.XX
PAUSE
DELAY
Percent rate setpoint. Performs functions based on a specified percentage of the configured Max
Capacity.
Pauses the batch sequence indefinitely. A BATSTRT signal must be initiated to continue the batch
process.
Delays the batch sequence for a specified time. The length of the delay (in tenths of a second) is
specified by the VALUE parameter.
Table 10-1. Setpoint Kinds
XX
X–
X–
84Visit our website www.RiceLake.com
Page 85
Setpoints
RED
WHITE
BLACK
RED
BLACK
A
B
O
R
T
S
T
A
R
T
3
4
1
2
NONCNC
NONO
+5VDC
GND
DIO1
DIO2
DIO3
DIO4
DIGITAL I/O
1 24563
CPU BOARD
3
4
1
2
3
4
10.2Batch Operations
Batches are controlled by digital inputs, EDP commands, the F1 (Start) and F2 (Stop) front panel switches, or iRite programs.
For iRite control, please see the iRite programming manual (PN 67888).
Batch Run (BATRUN digital input) – If a BATRUN digital input is configured, it must be active (low) for a batch to be started and
for it to continue to run. If a batch is running and the input becomes inactive (high), it stops the batch at the current batch
setpoint and turn off all associated digital outputs.
Batch Start (BATSTR digital input, BATSTART EDP command, or F1 (Start) key) – If the BATRUN digital input is active (low), or
is not assigned, batch start will start a batch, resume a paused batch or resume a stopped batch. If the BATRUN digital input is
inactive (high), batch start resets the current batch.
Batch Pause (BATPAS digital input or BATPAUSE EDP command) – The BATPAS digital input pauses an active batch, turning off
all associated digital outputs, while the input is active (low). As soon as the BATPAS digital input is made inactive (high), the
batch resumes. BATPAUSE EDP command works the same as the BATPAS digital input, except the batch does not resume
until a batch start signal is received.
Batch Stop (BATSTP digital input, BATSTOP EDP command, or F2 (Stop) key) – Stops an active batch at the current setpoint
and turns off all associated digital outputs.
Batch Reset (BATRST digital input or BATRESET EDP command) – Stops and resets an active batch to the beginning of the
process.
WARNING: Software-based interrupts must always be supplemented by emergency stop switches and other safety devices
necessary for the application to prevent personal injury and equipment damage.
Batching Switch
The batching switch option, PN 19369, comes as a complete unit in an FRP enclosure, with legend plate, locking stop switch
(mushroom button) and a run/start/abort 3-way switch.
Both switches are wired into the digital I/O terminal strip of the 882D as shown in Figure 10-1. Each switch uses a separate
digital input. Digital input #1 must be set to BATSTR and #2 must be set to BATRUN.
Ensure cables and switches are connected to the 882D and then use the setup switch to place the 882D in configuration mode.
Use the Digital I/O menu (Section 4.6.6 on page 42) to configure digital input and output functions.
ABORT/RUN/START SWITCH
EMERGENCY START/STOP SWITCH
Figure 10-1. Batching Switch and Wiring Diagram Example
Exit configuration mode when configuration is complete. Initialize the batch by turning the 3-way switch to ABORT, then unlock
the STOP button (the STOP button must be in the OUT position to allow the batch process to run). The batching switch is now
ready to use.
WARNING: Batching proceeds as if BATRUN were always on, if no digital input is assigned to BATRUN: the batch starts
when the 3-way switch is turned to RUN, but the STOP mushroom button will not function.
To begin a batch process, turn the 3-way switch to START momentarily. The process halts and the button locks in the IN
position if the STOP button is pushed during the batch process.
The START switch is ignored while the STOP button is locked in the IN position. The STOP button must be turned
counterclockwise to unlock it, then released to the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it left off:
1.Unlock STOP button (OUT position).
2.Turn 3-way switch to START.
To restart an interrupted batch from the first batch step:
1.Turn 3-way switch to ABORT.
2.Unlock STOP button (OUT position).
3.Turn 3-way switch to START.
NOTE: Use this procedure (or the BATRESET serial command) to initialize the new batch routine following any change to
the setpoint configuration.
10.3Batching Example
The Batching parameter within the Setpoints menu must be set to MANUAL.
NOTE: Digital I/O, Slot 0, Bit 1 = BATSTR
Digital I/O, Slot 0, Bit 2 = OUTPUT
The following example is used to dispense material into a processing zone to a quantity of 1000 tons.
Setpoint 1 ensures that the belt is receiving material greater than 100 tn/h.
Kind = RATE
Value = 100
Trip = HIGHER
Batch Sequence = ON
Setpoint 2 ensures that the belt is not overloaded with material and receiving less than 200 tn/h.
Kind = RATE
Value = 200
Trip = LOWER
Batch Sequence = ON
Setpoint 3 tracks the total weight moving across the belt. Once Totalizer 1 equals 1000 tons, the feeder suppling material to the
belt is stopped.
Kind = TOTAL
Value = 1000
Source = TOTALIZER 1
Trip = HIGHER
Batch Sequence = ON
Slot = SLOT0
Digital Output = BIT2
86Visit our website www.RiceLake.com
Page 87
Maintenance
11.0Maintenance
The maintenance information in this manual is designed to cover aspects of maintaining and troubleshooting the 882D. Contact
Rice Lake Weighing Systems if a problem requires technical assistance.
NOTE: Have the scale model number and serial number available when calling for assistance.
11.1Maintenance Checkpoints
The scale must be checked frequently to determine when a calibration is required. It is recommended a zero calibration be
checked every other day and a calibration checked every week for several months after installation. Observe the results and
lengthen the period between calibration checks, depending upon the accuracy desired.
NOTE: Establish a routine inspection procedure including the belt conveyor scale and the entire material handling system.
Note any changes in the scale function and report them to the individual or department responsible for the scales’
performance.
11.2Field Wiring
If a problem with the belt scale wiring is suspected, check the electrical portion of the scale.
• Check for proper interconnections between the components of the system. All the wiring must be as specified on the
installation drawings.
• Check all wiring and connections for continuity, shorts and grounds using an ohmmeter.
• Loose connections, poor solder joints, shorted or broken wires and unspecified grounds in wiring cause erratic readings
and shifts in weight readings.
• Check all cable shields to ensure grounding is made at only the locations specified in the installation drawings.
11.3Troubleshooting Tips
Table 11-1 lists general troubleshooting tips for hardware and software error conditions
SymptomPossible CauseRemedy
882D does not power upBad power supply
Battery backed corrupt error message at
startup
Divide by zero error message at startup User program errorRework the iRite user program to eliminate divide-by-zero situations
Dashes in weight display
Display reads 0.000000Scale not updating
Cannot enter setup modeBad switchTest switch
Serial port not respondingConfiguration errorEnsure port INPUT parameter is set to CMD for command input
A/D scale out of range
Option card failure
Dead battery
Over or under range scale
condition
Scale operation
Load cell connection
Bad load cell
Possible defective card
or slot
Table 11-1. Basic Troubleshooting
Check fuses and replace if necessary; If fuses are good, check all voltages on CPU
board; Power supply should output both +6 V and –6 V levels to the CPU board
Perform configuration reset then check for low battery warning on display;
If battery is low, replace battery, perform another configuration reset, then reload
files/configuration
Check scale; For out-of -range conditions in total scale display, check all scale
inputs for positive weight values
Make sure that all cables/wires are connected for the pulse input and/or load cell; A
power cycle might be necessary
Check source scale for proper mechanical operation
Check load cell and cable connection
Check 882D operation with load cell simulator
Disconnect power, install card in different slot, then apply power again
The 882D display shows low bat when battery voltage depletes to 2.9 VDC. Replace the battery when this warning is displayed
to prevent data loss in the event of a power failure. The battery life varies depending on use. It is recommended to replace the
battery every three years, or sooner, if left powered off for extended periods of time.
Use the Revolution configuration utility (Section 6.0 on page 55) or EDP commands (Section 7.0 on page 57) to store a copy of
the 882D configuration on a PC before attempting battery replacement. The 882D configuration can be restored from the PC if
data is lost.
WARNING: Risk of explosion if battery is replaced with an incorrect type. Dispose of used batteries according to state and
local regulations.
11.5Board Replacement
Display Board
CPU Mounting
Plate
Power Supply
Board
Standoff
CPU Board
Figure 11-1. Board Locations
1.Disconnect power to the 882D.
2.Remove the backplate from the enclosure. See Section 2.3 on page 12.
NOTE: Label connections for re-installation of board.
Keep this as a record of maintenance performed on the belt scale system.
Conveyor Number
Date
Scale Capacity (Tons per Hour)
Load Cell mV/V (Average)
Number of Load Cells (NLC)
Load Cell Capacity (LCC)
Total Load Cell Build = NLC x LCC
Number of Weigh Idlers
Idler Spacing
Conveyor Belt Length
Pulses per Revolution
Number of Test Revolutions
Zero Counts
Correction Factor
90Visit our websitewww.RiceLake.com
Page 91
Appendix
12.0Appendix
12.1Error Messages
The 882D provides a number of error messages. When an error occurs, the message is shown on the display. Error conditions
can also be checked remotely by using the XE EDP command as described in Section 7.2.6 on page 61.
12.1.1 Displayed Error Messages
The 882D provides a number of front panel error messages to assist in problem diagnosis.
Error MessageDescriptionSolution
¯ ¯ ¯ ¯ ¯ ¯
OVERFLOWWeigh string too large to be displayedIncrease the count by to decrease the size of the weigh string
CFGERR
ERRORInternal program errorCheck configuration
HWFERR
LOBATT
RANGE
NO ZERO
SPEED INPUT n
ERROR
Over range (upper dashes)
Under range (lower dashes)
A/D out of range (centered dashes)
Or if using local/remote (serial scale) - loss of serial scale data.
Configuration error on power up if there was an error loading
configuration
Hardware failure error
on failure to write to the EEPROM
any error (except for a battery error or an accumulation over
range error) when exiting the menu
The low battery error flashes every 30 seconds when the battery
is low.
A numeric value entered in configuration is out of the acceptable
range. The error is displayed momentarily – then parameter
being edited is displayed so the value can be corrected.
Zero is prevented (due to regulatory mode settings, motion on
the scale, zero range settings)
Pulse input error; n = 1 or 2; This error is displayed when there is
not pulse input detected by the pulse input circuit.
Re-enter a value that is in range for the parameter being edited
Check zero settings and for motion
Check that the belt is in motion and that the speed sensor and
wiring are working correctly
Table 12-1. 882D Error Messages
12.2Using the HARDWARE Command
The HARDWARE serial command can be used to verify that installed option cards are recognized by the system. The
HARDWARE command returns three 3-digit card codes, representing the cards installed. HARDWARE=000,yyy,zzz is the
returned format, where yyy is for slot 1 and zzz is for slot 2.
Table 12-2. HARDWARE Command Option Card Type Codes
The HARDWARE command returns code of 000 if an installed card is not recognized. Ensure card is seated properly. Reinstall
the card, if necessary, then cycle the power to read the configuration again. Try a different option card if the card is still not
recognized.
Use the decimal values for ASCII characters when specifying print format strings on the PFORMT menu. The actual character
printed depends on the character mapping used by the output device.
The indicator can send or receive any ASCII character value (decimal 0–255), but due to limitations of the indicator display,
some characters cannot be shown.
Sends the new line termination
configured for the port
12.4Data Formats
12.4.1 Stream Serial Data Format
If stream data transmission is configured for the communication ports (STRLFT or STRIND), by default the 882D sends data
using the serial data format shown in Figure 12-1. RS-422 is also available and uses the same serial data format.
Figure 12-1. Stream Serial Data Format
NOTE: If the COM port is set to TYPE = RS485, the port will not stream data.
12.4.2 Stream Tokens
TokenDescription
<R>The current rate with units included
<S>The current speed with units included
<L>The current load with units included
<MT>Master Totalizer value – without units
<T1>Totalizer 1 value – without units
<T2>Totalizer 2 value – without units
<TU>Totalizer units (kg, lb, t or tn); Defined by Totalizer Resolution Parameter
<DT1>Date of the last Totalizer 1 clear
<TT1>Time of the last Totalizer 1 clear
<DT2>Date of the last Totalizer 2 clear
<TT2>Time of the last Totalizer 2 clear
<CR>Carriage return, hex 0x0D
<LF>Line feed, hex 0x0A
<FF>Form feed, hex 0x0C
<USnn>Insert user print text string (from iRite user program, SetPrintText API); Defined by iRite user program
<SPnn>Space, nn = number of spaces; If nn is not specified, 1 is assumed; Value must be in the range 1-99
<NLnn>
<nnn>
New line, nn = number of termination (<CR/LF> or <CR>) characters; If nn is not specified, 1 is assumed;
Value must be in the range 1-99; Defined by TERMIN setting of the port
Note: when streaming data, a configured End-of-Line Delay is performed after each New Line
ASCII character (nnn = decimal value of ASCII character). Used for inserting control characters
(002 for an STX, for example) in the output.
Table 12-5. Stream Tokens
94Visit our websitewww.RiceLake.com
Page 95
Appendix
<STX> <ADDRESS> <COMMAND> <CR>
ASCII 02
decimal
EDP serial command
NOTE: Host must send <CR>, not
<CR><LF>. Failure to use <CR>
renders all indicators unable to
ASCII
13 decimal
The address of the recieving
indicator is a single ASCII
character with in the range of 0-255
where EOL = <CR> or <CR> <LF>
(set by TERMIN parameter on the
SERIAL menu)
ASCII 13
decimal
ASCII 03
decimal
12.4.3 Print Output Serial Data Format
The 882D uses a data string format for a basic ticket printout. The print format is configured in the setup menu for the demand
(print) port, and depends on the 882D configuration and mode. See Section 8.0 on page 77 for print formatting.
Use the EDP commands, Revolution or the front panel to fully customize the print to work with a wide variety of printers, and
other remote equipment.
12.4.4 RS-485 Data Formats
The 882D has a built-in RS-485 software protocol which is enabled when configuring a port’s TYPE as 485. On the 882D only
the COM port has hardware support for RS-485 communication.
All RS-485 communication with the 882D is via command and response. An external host must send a command and wait for a
response.
All remote commands are initiated using the data format in Figure 12-2:
respond to serial commands
Figure 12-2. RS-485 Send Data Format
If the initiating device address matches the port address of a 882D on the RS-485 network, that indicator responds. The
responding indicator uses the format in Figure 12-3:
Figure 12-3. RS-485 Respond Data Format
* Communication with an RS-485 882D is command / response only; An 882D configured for RS-485 cannot print a ticket or stream
continuous data
* Any valid EDP command can be sent to the 882D when in RS-485 mode
* If a command is unrecognized or cannot be executed, the 882D responds with ?? wrapped in the RS-485 protocol
For example: <STX><ADDRESS>??<ETX><CR>
* Depending on the command, the <RESPONSE> may include its own termination characters that are sent before the <ETX><CR>
* A multi-line response, e.g. from a DUMPALL command, is wrapped in the header and footer as a total but each individual line is not
EOL - <CR> or <CR><LF> (set by the TERMIN parameter for the port)
Example: To send the LD command from an ASCII terminal to an indicator at address 65 (decimal) on the RS-485 network, use
the format in Figure 12-2 on page 95.
• The keyboard equivalent for the start-of-text (STX) character is CONTROL-B (Section 12.3 on page 92)
• The indicator address (65) is represented by an upper case “A”
• The carriage return (CR) character is generated by pressing the
Enter key
Therefore, to send the LD command to the indicator at address 65, enter the following at the terminal:
<CONTROL-B>ALD<CR>
The indicator responds with <STX>A 1234.00 lb/ft<CR><LF><ETX><CR>. See Section 7.0 on page 57 for other commands
that can be used.
12.5Analog Output Calibration
See Section 4.6.7 on page 43, for Analog Output parameters.
The following calibration procedure requires a multimeter to measure voltage or current output from the analog output module.
If the option is not already installed, install it in according to the instructions included with the option.
NOTE:
The analog output must be calibrated after the
and calibrated (
Section 5.0 on page 46
).
1.Enter configuration mode and go to the Analog Output menu (Figure 4-20 on page 43):
• Set Source as desired to SCALE or PROG
• Set Mode as desired to RATE, SPEED or LOAD
• Set Output as desired for 0-10V, 0-20mA, or 4-20mA output
• Set Minimum to lowest value to be tracked by the analog output
• Set Maximum to highest value to be tracked by the analog output
2.Connect multimeter to connector J1 on the analog output board:
• For voltage output, connect voltmeter leads to pins 3 and 4 (-V, +V)
• For current output, connect ammeter leads to pins 1 and 2 (-mA, +mA)
3.Adjust zero calibration:
• Scroll to the Calibrate Zero parameter
882D
has been configured (
Section 4.0 on page 27
)
• Press , 0.000000 will display
• Check voltage or current reading on multimeter
• Set the parameter to match the reading from the multimeter
• Press or to select the digit
• Press or to increment or decrement the value
• Press to accept the displayed value
• CAL will be displayed while the calibration is being performed
96Visit our website www.RiceLake.com
Page 97
4.Adjust span calibration:
MODE
SETPOINT
PRINT
ZERO
MODE
ENTER
• Scroll to the Calibrate Span parameter
• Press , 0.000000 will display
• Set the parameter to match the reading from the multimeter
• Press or to select the digit
• Press or to increment or decrement the value
• Press to accept the displayed value
• CAL will be displayed while the calibration is being performed
5.Verify calibration:
• Return to the Calibrate Zero/Calibrate Span parameter and verify that the calibration has not drifted
• Repeat calibration if needed
6.Return to weigh mode.
12.6Cable Specifications
Appendix
ConnectorWire Gauge RangeWire Strip Length
J1 and J2 (PN 153873)16-28 AWG0.276'' (7 mm)
J3 (PN 153883)16-28 AWG0.276'' (7 mm)
J13 (PN 181694)16-24 AWG0.394'' (10 mm)
DC Power (PN 15888)12-24 AWG0.276'' (7 mm)
JP1Not used
JP2Watchdog jumper – Leave jumper shorted for normal operation
JP3Remote setup switch header
JP4Audit jumper
JP5Remote sense jumper
JP6Remote sense jumper
LED1Not used
LED2Not used
LED4882D heartbeat
LED5Digital I/O 3
LED6Digital I/O 4
LED7Digital I/O 1
LED8Digital I/O 2
LED9Transmit and receive for the serial port (2 LEDs)
LED10Not used
SW1Hardware reset switch
SW2Not used
SW3RS-232 / RS-485 / RS-422 switches (Section 2.4.7 on page 16)
SW4Not used
TP4Battery ground test point
TP34Pulse input 0 test point
TP42Pulse input 1 test point
TP43Pulse input ground test point
TP44Battery voltage + test point
TP45Battery voltage - test point
EN 60950-1:2006+A11:2009/A1:2010/A12:2011/A2:2013, EN 62368-1:2014
EN 50581:2012
EN 60079-0:2012+A11:2013, EN 60079-11:2012, EN 60079-7: 2015 +A1:2018, EN
60079-15: 2010, EN 60079-31:2014
Notified Body involved with module B: / Benannte Stelle, die an Modul B beteiligt ist: /
Organisme notifié impliqué dans les modules B:
UL International Demko A/S - 0539