Rheem RRNA-B User Manual

RRNA-B
Parts List
07-April-2015
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RRNA-B.pdf for the current revision.
Package Gas-Electric
Model Explanation..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . .... . ..... ..... . ..... ..... ... Page 3
Parts Numbers
Panels - Miscellaneous 024-036 . . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . .... Page 4
Panels - Miscellaneous 042-060 . . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . .... Page 5
Electrical Group (1).. . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... Page6
Electrical Group (2).. . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... Page7
Fan Group... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .. Page 8
Blower Group... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... Page 9
Coil Parts .. . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ... Page 10
Compressor Group ... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ... Page 11
Heat Exchanger-Burner Group.... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... .. Page 12
Gas Controls ... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... .... Page 13
Accessories ... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... Page 13
Orifice Selection Chart.... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... Page14
Drawings/Photographs
Exploded View .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... . Page 15
Control Access Panel Detail .... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... .... Page16
Electrical Control Box.... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . Page 17
Blower Assembly . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ... Page 18
Evaporator Coil Assembly..... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . .... . ..... ..... . ..... ..... . Page 19
Condenser Coil.... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... . Page 20
Compressor and Refrigeration Components.... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... Page 21
Heat Exchanger Assembly.... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . Page 22
Burner Assembly (Inshot - Before Approx F3708)... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . . Page 23
Burner Assembly (One-piece - After Approx F3708) ... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... .... Page 24
Notes/Disclaimer . . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... ..... . ..... ..... . .... . ..... ..... . ..... ..... . Page 25
Page 2 of 25
07-April-2015
92-42800-RRNA-B
R R N A - B 0 3 6 J K 1 0 E A J A 1 2 3 4 5 6 7 8 9 10 11
(1) TRADENAME IDENTIFICATION (9) HEATING CAPACITY - (MBH) 04 = 40,000 (2) PRODUCT CLASSIFICATION 06 = 60,000 R = Rooftop 08 = 80,000 10 = 100,000 (3) EFFICIENCY DESIGNATION N = 13 SEER (10) IGNITION SYSTEM E = Electric (4) DESIGN SERIES X = Electric w/NOX A = FIRST DESIGN (11) OPTION CODES (5) TECHNICALVARIATION AJA = Stainless Steel Heat Exchanger AKA = Sideflow Option (6) COOLING CAPACITY (BTU/HR) BVA= Sideflow w/Stainless Steel Heat Exchanger 024 = 24,000 042 = 42,000 030 = 30,000 048 = 48,000 036 = 36,000 060 = 60,000
(7) ELECTRICAL DESIGNATION J = 208-230V/1/60 C = 208-230V/3/60 D = 460V/3/60
(8) DRIVE PACKAGE K = Direct Drive
1 R A 1 2 3 4 A D A A F 2 6 9 5 0 0 0 1 1 2 3 4 5 6 7 8 9 10 11
(1) GAS CODE (7) TECHNOLOGY VARIATIONS (2) BLOWER CONTROL BOARD (8) PLANT:
F = Fort Smith, AR (3) COMPRESSOR IDENTIFICATION NUMBER (9) WEEK (4) IGNITION DEVICE (10) YEAR (5) INDUCER BLOWER (11) PRODUCTION NUMBER (6) HEAT EXCHANGER
MODEL NUMBER EXPLANATION
SERIAL NUMBER EXPLANATION
Page 3 of 25
07-April-2015
92-42800-RRNA-B
No. Notes
1 Front Base Pan AS-58628-07 AS-58628-07 AS-58628-07 2 Base Rail (2) AE-58562-03 AE-58562-03 AE-58562-03 3 Base Rail (2) AE-58562-04 AE-58562-04 AE-58562-04 4 Back Base Pan AS-58607-64 AS-58607-64 AS-58607-64 5 Blower Shelf AS-58630-01 AS-58630-01 AS-58630-01 6 Blower ShelfTransition AS-58607-19 AS-58607-19 AS-58607-19 7 Divider Panel AS-58607-03 AS-58607-03 AS-58607-03 8 Bulkhead Assembly AS-58607-62 AS-58607-62 AS-58607-55
9 Exhaust Hood AS-58629-01 AS-58629-01 AS-58629-01 10 CombustionAir Inlet Hood AE-58599-01 AE-58599-01 AE-58599-01 11 Corner Post AS-58607-40 AS-58607-40 AS-58607-40 12 BlowerAccess Panel AS-58607-09 AS-58607-09 AS-58607-09 13 End Panel AS-58607-04 AS-58607-04 AS-58607-04 14 Supply Cover - Downflow AS-58607-06 AS-58607-06 AS-58607-06 14 Supply Cover - Side Option "AKA" AS-58607-35 AS-58607-35 AS-58607-35 15 Return Cover- Downflow AS-58607-05 AS-58607-05 AS-58607-05 15 Return Cover- Side Option "AKA" AS-58607-34 AS-58607-34 AS-58607-34 16 Top Panel AS-58607-60 AS-58607-60 AS-58607-58 17 Grille 95-100906-08 95-100906-08 95-100906-08 18 Filter Access Panel AS-58607-08 AS-58607-08 AS-58607-08 19 Condenser Louver Panel AS-58607-61 AS-58607-61 AS-58607-61 20 Center Post AE-58569-05 AE-58569-05 AE-58569-05 21 Control Access Panel AS-58607-20 AS-58607-20 AS-58607-20 22 Control Box - (w/o components) AE-58597-01 AE-58597-01 AE-58597-01 23 Control Box Cover AE-58598-01 AE-58598-01 AE-58598-01 24 Furnace Shelf AS-58607-11 AS-58607-11 AS-58607-11 25 Burner Floor AE-58594-01 AE-58594-01 AE-58594-01 26 ExhaustTransition AS-58607-36 AS-58607-36 AS-58607-36 27 BulkheadValve (2) 61-22369-04 61-22369-04 61-22369-04 28 BulkheadValve Locknut (2) 63-22368-01 63-22368-01 63-22368-01
Bulkhead Valve Cap (2) 83-100635-01 83-100635-01 83-100635-01 Heat Exchanger Tube Support AE-58590-01 AE-58590-01 AE-58590-01 Grommet - Gas Supply Piping 56-22114-01 56-22114-01 56-22114-01
MODEL TECHNICALVARIATION COOLING CAPACITY
PANELS, MISCELLANEOUS PARTS
RRNA
B
024
RRNA
B
030
RRNA
B
036
Page 4 of 25
07-April-2015
92-42800-RRNA-B
No. Notes
1 Front Base Pan AS-58628-07 AS-58628-07 AS-58628-07
2 Base Rail (2) AE-58562-03 AE-58562-03 AE-58562-03
3 Base Rail (2) AE-58562-04 AE-58562-04 AE-58562-04
4 Back Base Pan AS-58607-64 AS-58607-64 AS-58607-64
5 Blower Shelf AS-58630-01 AS-58630-01 AS-58630-01
6 Blower ShelfTransition AS-58607-19 AS-58607-19 AS-58607-19
7 Divider Panel AS-58607-03 AS-58607-03 AS-58607-03
8 Bulkhead Assembly AS-58607-57 AS-58607-57 AS-58607-57
9 Exhaust Hood AS-58629-01 AS-58629-01 AS-58629-01 10 CombustionAir Inlet Hood AE-58599-01 AE-58599-01 AE-58599-01 11 Corner Post AS-58607-46 AS-58607-46 AS-58607-46 12 BlowerAccess Panel AS-58607-47 AS-58607-47 AS-58607-47 13 End Panel AS-58607-48 AS-58607-48 AS-58607-48 14 Supply Cover - Downflow AS-58607-06 AS-58607-06 AS-58607-06 14 Supply Cover - Side Option "AKA" AS-58607-35 AS-58607-35 AS-58607-35 15 Return Cover- Downflow AS-58607-05 AS-58607-05 AS-58607-05 15 Return Civer- Side Option "AKA" AS-58607-34 AS-58607-34 AS-58607-34 16 Top Panel AS-58607-54 AS-58607-54 AS-58607-54 17 Grille 95-100906-08 95-100906-08 95-100906-08 18 Filter Access Panel AS-58607-49 AS-58607-49 AS-58607-49 19 Condenser Louver Panel AS-58607-56 AS-58607-56 AS-58607-56 20 Center Post AE-58569-07 AE-58569-07 AE-58569-07 21 Control Access Panel AS-58607-50 AS-58607-50 AS-58607-50 22 Control Box - (w/o components) AE-58597-01 AE-58597-01 AE-58597-01 23 Control Box Cover AE-58598-01 AE-58598-01 AE-58598-01 24 Furnace Shelf AS-58607-11 AS-58607-11 AS-58607-11 25 Burner Floor AE-58594-01 AE-58594-01 AE-58594-01 26 ExhaustTransition AS-58607-36 AS-58607-36 AS-58607-36 27 BulkheadValve (2) 61-22369-04 61-22369-04 61-22369-04 28 BulkheadValve Locknut (2) 63-22368-01 63-22368-01 63-22368-01
Bulkhead Valve Cap (2) 83-100635-01 83-100635-01 83-100635-01 Heat Exchanger Tube Support AE-58590-01 AE-58590-01 AE-58590-01 Grommet - Gas Supply Piping 56-22114-01 56-22114-01 56-22114-01
MODEL TECHNICALVARIATION COOLING CAPACITY
PANELS, MISCELLANEOUS PARTS
RRNA
B
042
RRNA
B
048
RRNA
B
060
Page 5 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
31 Stk Induced Draft Blowerw/Gasket 70-23641-01 70-23641-01 70-23641-01 70-23641-01 70-23641-01 70-23641-01
Gasket - Induced Draft Blower 68-23643-01 68-23643-01 68-23643-01 68-23643-01 68-23643-01 68-23643-01 33 Stk Contactor 42-42728-03 42-42728-03 42-42728-03 42-42728-03 42-42728-03 42-42728-03 34 Stk Pressure Switch 42-24335-20 42-24335-20 42-24335-20 42-24335-20 42-24335-20 42-24335-20 35 Stk Transformer 46-100836-02 46-100836-02 46-100836-02 46-18788-05 46-18788-05 46-18788-05 36 Ground Lug 45-19000-01 45-19000-01 45-19000-01 45-19000-01 45-19000-01 45-19000-01 39 Integrated Furnace Control Board (IFC) See Gas Controls 57 Stk Blower Relay N/A N/A N/A N/A N/A 42-101208-02 73 Capacitor - Compressor/Fan See Compressor Group
Capacitor - Blower Motor See Blower Group 84 Limit Control - Blower Shelf See Heat Exchanger-Burner Group 88 Limit Control - Roll Out See Heat Exchanger-Burner Group
Compressor Wiring Harness (Molded Plug) See Compressor Group
Wiring Harness - 9 pin to 9 insulated terminals AS-102393-02 AS-102393-02 AS-102393-02 AS-102393-02 AS-102393-02 AS-102393-02
Capacitor Adaptor Plate (2 in. round capacitor) AE-54609-01 AE-54609-01 AE-54609-01 AE-54609-01 AE-54609-01 AE-54609-01
No. Notes
31 Stk Induced Draft Blowerw/Gasket 70-23641-01 70-23641-01 70-23641-01 70-23641-01
Gasket - Induced Draft Blower 68-23643-01 68-23643-01 68-23643-01 68-23643-01 33 Stk Contactor 42-22464-01 42-22464-01 42-22464-01 42-22464-01 34 Stk Pressure Switch 42-24335-20 42-24335-20 42-24335-20 42-24335-20 35 Stk Transformer 46-18788-05 46-18788-05 46-18788-05 46-18788-05 36 Ground Lug 45-19000-01 45-19000-01 45-19000-01 45-19000-01 39 Integrated Furnace Control Board (IFC) See Gas Controls 57 Stk Blower Relay N/A N/A N/A 42-101208-02 73 Capacitor - Fan Motor See FanGroup
Capacitor - Blower Motor See Blower Group 84 Limit Control - Blower Shelf See Heat Exchanger-Burner Group 88 Limit Control - Roll Out See Heat Exchanger-Burner Group
Compressor Wiring Harness (Molded Plug) See Compressor Group
Wiring Harness - 9 pin to 9 insulated terminals AS-102393-02 AS-102393-02 AS-102393-02 AS-102393-02
Capacitor Adaptor Plate (2 in. round capacitor) AE-54609-01 AE-54609-01 AE-54609-01 AE-54609-01
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
Leadwire - from Flame Sensor to 9 pin Wiring Harness Plug ECM Wiring Harness - 16 pin to 5 terminals (2 insulated and 3 uninsulated) ECM Wiring Harness - 5 pin to 2 quick connect and 1 ring terminal.
Capacitor Adaptor Plate (2 in. X 1-1/4 in. oval capacitor)
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
Leadwire - from Flame Sensor to 9 pin Wiring Harness Plug ECM Wiring Harness - 16 pin to 5 terminals (2 insulated and 3 uninsulated) ECM Wiring Harness - 5 pin to 2 quick connect and 1 ring terminal.
Capacitor Adaptor Plate (2 in. X 1-1/4 in. oval capacitor)
RRNA
B
024
J
ELECTRICAL GROUP
45-25323-02 45-25323-02 45-25323-02 45-25323-02 45-25323-02 45-25323-02
N/A N/A N/A N/A N/A 45-24258-13
N/A N/A N/A N/A N/A 45-24258-12
AE-54609-02 AE-54609-02 AE-54609-02 AE-54609-02 AE-54609-02 AE-54609-02
RRNA
B
036
C
ELECTRICAL GROUP
45-25323-02 45-25323-02 45-25323-02 45-25323-02
N/A N/A N/A 45-24258-13
N/A N/A N/A 45-24258-12
AE-54609-02 AE-54609-02 AE-54609-02 AE-54609-02
RRNA
B
030
J
RRNA
B
042
C
RRNA
B
036
J
RRNA
B
048
C
RRNA
B
042
J
RRNA
B
060
C
RRNA
B
048
J
RRNA
B
060
J
Page 6 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
31 Stk Induced Draft Blowerw/Gasket 70-23641-02 70-23641-02 70-23641-02
Gasket - Induced Draft Blower 68-23643-01 68-23643-01 68-23643-01 33 Stk Contactor 42-22464-01 42-22464-01 42-22464-01 34 Stk Pressure Switch 42-24335-20 42-24335-20 42-24335-20 35 Stk Transformer 46-102027-01 46-102027-01 46-102027-01 36 Ground Lug 45-19000-01 45-19000-01 45-19000-01 39 Integrated Furnace Control Board (IFC) See Gas Controls 57 Stk Blower Relay 42-19736-05 42-19736-05 42-19736-05 73 Capacitor - Compressor/Fan See Compressor Group
Capacitor - Blower Motor See Blower Group 84 Limit Control - Blower Shelf See Heat Exchanger-Burner Group 88 Limit Control - Roll Out See Heat Exchanger-Burner Group
Compressor Wiring Harness (Molded Plug) See Compressor Group
Wiring Harness - 9 pin to 9 insulated terminals AS-102393-02 AS-102393-02 AS-102393-02
Capacitor Adaptor Plate (2 in. round capacitor) AE-54609-01 AE-54609-01 AE-54609-01
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
Leadwire - from Flame Sensor to 9 pin Wiring Harness Plug
Capacitor Adaptor Plate (2 in. X 1-1/4 in. oval capacitor)
RRNA
B
036
D
ELECTRICAL GROUP
45-25323-02 45-25323-02 45-25323-02
AE-54609-02 AE-54609-02 AE-54609-02
RRNA
B
048
D
RRNA
B
060
D
Page 7 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
Note: 024, 030, and 036 units produced before October 2006 may have been produced with a different motor, capacitor, and fan blade combination than shown below.If replacing any of these components on older units, all three components must be changed in accordance with those listed below. Failure to do so may affect motor reliability and increase fan noise.
37 Stk FanMotor 51-100998-24 51-100998-24 51-100998-24 51-100998-19 51-100998-19 51-100998-19 38 Stk FanBlade 70-101323-19 70-101323-19 70-101323-19 70-23594-02 70-23594-02 70-23594-02 73 Capacitor - Compressor/Fan See Compressor Group
No. Notes
Note: 024, 030, and 036 units produced before October 2006 may have been produced with a different motor, capacitor, and fan blade combination than shown below.If replacing any of these components on older units, all three components must be changed in accordance with those listed below. Failure to do so may affect motor reliability and increase fan noise.
37 Stk FanMotor 51-100998-24 51-100998-19 51-100998-19 51-100998-19 38 Stk FanBlade 70-101323-19 70-23594-02 70-23594-02 70-23594-02 73 Stk Capacitor - Fan Motor 43-100496-04 43-100496-12 43-100496-12 43-100496-12
No. Notes
37 Stk FanMotor 51-100998-26 51-100998-20 51-100998-20 38 Stk FanBlade 70-101323-19 70-23594-02 70-23594-02 73 Stk Capacitor - Fan Motor 43-100496-03 43-100496-11 43-100496-11
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
RRNA
B
024
J
FANGROUP
RRNA
B
036
C
FANGROUP
RRNA
B
036
D
FANGROUP
RRNA
B
030
J
RRNA
B
042
C
RRNA
B
048
D
RRNA
B
036
J
RRNA
B
048
C
RRNA
B
060
D
RRNA
B
042
J
RRNA
B
060
C
RRNA
B
048
J
RRNA
B
060
J
Page 8 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
Stk Blower Assembly (Includes items 51-56) AS-58662-01 AS-58662-05 AS-58662-05 AS-58662-05 AS-58662-06 AS-58662-14 51 Housing AS-58619-01 AS-58619-02 AS-58619-02 AS-58619-02 AS-58619-02 AS-58619-02 52 Stk BlowerWheel 70-20218-01 70-18625-03 70-18625-03 70-18625-03 70-18625-03 70-18625-03 53 Cut-Off AE-64401-10 AE-64401-06 AE-64401-06 AE-64401-06 AE-64401-06 AE-64401-06 54 Stk Motor 51-23608-02 51-23609-04 51-23609-04 51-23609-04 51-23650-01 51-24376-15
Motor Mounting Bracket Assembly (includes 55, 56) AS-53148-03 AS-53148-04 AS-53148-04 AS-53148-04 AS-53148-04 N/A 55 Motor Band 70-19927-01 70-19927-01 70-19927-01 70-19927-01 70-19927-01 70-19927-03 56 Motor Arm Assembly (3) 70-19929-02 70-19929-02 70-19929-02 70-19929-02 70-19929-02 70-19929-09 57 Blower Relay See Electrical Group
Stk Capacitor- Blower Motor 43-100496-04 43-100496-12 43-100496-12 43-100496-12 43-100496-45 N/A
No. Notes
Stk Blower Assembly (Includes items 51-56) AS-58662-05 AS-58662-05 AS-58662-06 AS-58662-14 51 Housing AS-58619-02 AS-58619-02 AS-58619-02 AS-58619-02 52 Stk BlowerWheel 70-18625-03 70-18625-03 70-18625-03 70-18625-03 53 Cut-Off AE-64401-06 AE-64401-06 AE-64401-06 AE-64401-06 54 Stk Motor 51-23609-04 51-23609-04 51-23650-01 51-24376-15
Motor Mounting Bracket Assembly (includes 55, 56) AS-53148-04 AS-53148-04 AS-53148-04 N/A 55 Motor Band 70-19927-01 70-19927-01 70-19927-01 70-19927-03 56 Motor Arm Assembly (3) 70-19929-02 70-19929-02 70-19929-02 70-19929-09 57 Blower Relay See Electrical Group
Stk Capacitor- Blower Motor 43-100496-12 43-100496-12 43-100496-45 N/A
No. Notes
Stk Blower Assembly (Includes items 51-56) AS-58662-19 AS-58662-18 AS-58662-18 51 Housing AS-58619-02 AS-58619-02 AS-58619-02 52 Stk BlowerWheel 70-18625-03 70-18625-03 70-18625-03 53 Cut-Off AE-64401-06 AE-64401-06 AE-64401-06 54 Stk Motor 51-102021-01 51-102021-02 51-102021-02
Motor Mounting Bracket Assembly (includes 55, 56) AS-53148-04 AS-53148-04 AS-53148-04 55 Motor Band 70-19927-01 70-19927-01 70-19927-01 56 Motor Arm Assembly (3) 70-19929-02 70-19929-02 70-19929-02 57 Blower Relay See Electrical Group
Stk Capacitor- Blower Motor 43-100496-12 43-100496-12 43-100496-12
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
RRNA
B
024
J
BLOWER GROUP
RRNA
B
036
C
BLOWER GROUP
RRNA
B
036
D
BLOWER GROUP
RRNA
B
030
J
RRNA
B
042
C
RRNA
B
048
D
RRNA
B
036
J
RRNA
B
048
C
RRNA
B
060
D
RRNA
B
042
J
RRNA
B
060
C
RRNA
B
048
J
RRNA
B
060
J
Page 9 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
CONDENSER COIL: 61 Stk Condenser Coil AS-101997-03 AS-101997-03 AS-101993-03 AS-101994-03 AS-101996-01 AS-101996-01
Distributor Assembly AS-101689-02 AS-101689-02 AS-101689-02 N/A AS-101689-01 AS-101689-01
Distributor - (Two way - 3/8 in. to 3/8 in.) 83-17467-02 83-17467-02 83-17467-02 N/A 83-17467-02 83-17467-02
Access Valve Body (2) 61-18542-01 61-18542-01 61-18542-01 61-18542-01 61-18542-01 61-18542-01
Access Valve Core (2) 61-18551-01 61-18551-01 61-18551-01 61-18551-01 61-18551-01 61-18551-01
EVAPORATOR COIL: 62 Stk Evaporator Coil w/Drain Pan AS-102660-04 AS-102660-04 AS-102660-03 AS-102660-02 AS-102660-01 AS-102660-01 63 Drain Pan Grommet 56-23601-01 56-23601-01 56-23601-01 56-23601-01 56-23601-01 56-23601-01 64 Stk Drain Pan - Before F4507 AS-58607-32 AS-58607-32 AS-58607-32 AS-58607-32 AS-58607-32 AS-58607-32 64 Stk Drain Pan - After F4507 68-23602-02 68-23602-02 68-23602-02 68-23602-02 68-23602-02 68-23602-02
64a Drain Trap (Attached to Drain Pan) 68-23603-01 68-23603-01 68-23603-01 68-23603-01 68-23603-01 68-23603-01
65 Auxiliary Drain Pipe AE-58611-01 AE-58611-01 AE-58611-01 AE-58611-01 AE-58611-01 AE-58611-01 66 Stk Flowcheck Distributor/Piston Assembly 61-102106-12 61-102106-12 61-102106-14 61-102108-14 61-102108-17 61-102108-17 67 Stk TXV 61-21922-113 61-21922-112 61-21922-111 61-21922-75 61-21922-75 61-21922-102 68 Condensate Shield AE-101751-01 AE-101751-01 AE-101751-01 AE-101751-02 AE-101751-02 AE-101751-02
68a Condensate Barrier AE-100544-01 AE-100544-01 AE-100544-01 AE-100544-02 AE-100544-02 AE-100544-02
No. Notes
CONDENSER COIL: 61 Stk Condenser Coil AS-101993-03 AS-101994-03 AS-101996-01 AS-101996-01
Distributor Assembly AS-101689-02 N/A AS-101689-01 AS-101689-01
Distributor - (Two way - 3/8 in. to 3/8 in.) 83-17467-02 83-17467-02 83-17467-02 83-17467-02
Access Valve Body (2) 61-18542-01 61-18542-01 61-18542-01 61-18542-01
Access Valve Core (2) 61-18551-01 61-18551-01 61-18551-01 61-18551-01
EVAPORATOR COIL: 62 Stk Evaporator Coil w/Drain Pan AS-102660-03 AS-102660-02 AS-102660-01 AS-102660-01 63 Drain Pan Grommet 56-23601-01 56-23601-01 56-23601-01 56-23601-01 64 Stk Drain Pan - Before F4507 AS-58607-32 AS-58607-32 AS-58607-32 AS-58607-32 64 Stk Drain Pan - After F4507 68-23602-02 68-23602-02 68-23602-02 68-23602-02
64a Drain Trap (Attached to Drain Pan) 68-23603-01 68-23603-01 68-23603-01 68-23603-01
65 Auxiliary Drain Pipe AE-58611-01 AE-58611-01 AE-58611-01 AE-58611-01 66 Stk Flowcheck Distributor/Piston Assembly 61-102106-14 61-102108-14 61-102108-17 61-102108-17 67 Stk TXV 61-21922-111 61-21922-75 61-21922-75 61-21922-102 68 Condensate Shield AE-101751-01 AE-101751-02 AE-101751-02 AE-101751-02
68a Condensate Barrier AE-100544-01 AE-100544-02 AE-100544-02 AE-100544-02
No. Notes
CONDENSER COIL: 61 Stk Condenser Coil AS-101993-03 AS-101996-01 AS-101996-01
Distributor Assembly AS-101689-02 AS-101689-01 AS-101689-01
Distributor - (Two way - 3/8 in. to 3/8 in.) 83-17467-02 83-17467-02 83-17467-02
Access Valve Body (2) 61-18542-01 61-18542-01 61-18542-01
Access Valve Core (2) 61-18551-01 61-18551-01 61-18551-01
EVAPORATOR COIL: 62 Stk Evaporator Coil w/Drain Pan AS-102660-03 AS-102660-01 AS-102660-01 63 Drain Pan Grommet 56-23601-01 56-23601-01 56-23601-01 64 Stk Drain Pan - Before F4507 AS-58607-32 AS-58607-32 AS-58607-32 64 Stk Drain Pan - After F4507 68-23602-02 68-23602-02 68-23602-02
64a Drain Trap (Attached to Drain Pan) 68-23603-01 68-23603-01 68-23603-01
65 Auxiliary Drain Pipe AE-58611-01 AE-58611-01 AE-58611-01 66 Stk Flowcheck Distributor/Piston Assembly 61-102106-14 61-102108-17 61-102108-17 67 Stk TXV 61-21922-111 61-21922-75 61-21922-102 68 Condensate Shield AE-101751-01 AE-101751-02 AE-101751-02
68a Condensate Barrier AE-100544-01 AE-100544-02 AE-100544-02
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
RRNA
B
024
J
COIL GROUP
RRNA
B
036
C
COIL GROUP
RRNA
B
036
D
COIL GROUP
RRNA
B
030
J
RRNA
B
042
C
RRNA
B
048
D
RRNA
B
036
J
RRNA
B
048
C
RRNA
B
060
D
RRNA
B
042
J
RRNA
B
060
C
RRNA
B
048
J
RRNA
B
060
J
Page 10 of 25
07-April-2015
92-42800-RRNA-B
MODEL
No. Notes
Compressor ID: 7284 7285 7287 7100 7102 7104 71 Stk Compressor 55-100835-07S 55-100835-08S 55-100835-25S 55-100835-15S 55-100835-11S 55-100835-06S 72 Grommet (4) 56-18518-04 56-18518-04 56-18518-04 56-18518-06 56-18518-06 56-18518-06
Stk CompressorWiring Harness (Molded Plug) 45-100834-80 45-100834-80 45-100834-80 45-100834-80 45-100834-80 45-100834-80 73 Stk Capacitor - Compressor/Fan 43-26271-44 43-26271-41 43-26261-16 43-26261-37 43-26271-45 43-26271-30
No. Notes
Compressor ID: 7286 7099 7101 7103 71 Stk Compressor 55-100835-34S 55-100835-21S 55-100835-29S 55-100835-19S 72 Grommet (4) 56-18518-04 56-18518-06 56-18518-06 56-18518-06
Stk CompressorWiring Harness (Molded Plug) 45-100834-80 45-100834-80 45-100834-80 45-100834-80
No. Notes
Compressor ID: 7378 7377 7376 71 Stk Compressor 55-100835-35S 55-100835-33S 55-100835-46S 72 Grommet (4) 56-18518-06 56-18518-06 56-18518-06
Stk CompressorWiring Harness (Molded Plug) 45-100834-80 45-100834-80 45-100834-80
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
RRNA
B
024
J
COMPRESSOR GROUP
RRNA
B
036
C
COMPRESSOR GROUP
RRNA
B
036
D
COMPRESSOR GROUP
RRNA
B
030
J
RRNA
B
042
C
RRNA
B
048
D
RRNA
B
036
J
RRNA
B
048
C
RRNA
B
060
D
RRNA
B
042
J
RRNA
B
060
C
RRNA
B
048
J
RRNA
B
060
J
Page 11 of 25
07-April-2015
92-42800-RRNA-B
No. Notes
81 Stk Heat Exchanger (Includes Center Panel andTurbulators) AS-58632-01 AS-58632-06 AS-58632-07 AS-58632-04 82 Turbulators
CollectorBox Gasket 68-23644-01 68-23644-01 68-23644-01 68-23644-01 83 Collector Box AE-58588-01 AE-58588-01 AE-58588-01 AE-58588-01
84 Stk Limit Control - Blower Shelf
84 Stk Limit Control - Blower Shelf
Rubber Water Protect Boot - Limit Switch
Rubber Water Protect Boot - Limit Switch
85 NOX Insert Assembly 86 Lower Burner Shield (NOX) AE-59148-01 AE-59148-01 AE-59148-01 AE-59148-01
87 Radiation Shield AE-58595-01 AE-58595-01 AE-58595-01 AE-58595-01 88 Stk,3
88 Stk,3
89 Stk,3
89 Stk,3
90 3
90 3
91 3
91 3 97 3 Bushing - After approximate Date Code F3708 (See Note 3) 45-42519-01 45-42519-01 45-42519-01 45-42519-01
Stk,2,3 One-piece Burner Retrofit Kit - See Note 2 AS-60993-82 AS-60993-83 AS-60993-84 AS-60993-85 92 Stk Manifold Assembly 81-101154-01 81-101154-01 81-101154-01 81-101154-01
94 Square Head Plug (Used on Manifold to plug extra holes) 93 Burner Orifice - Natural Gas See Orifice Selection Chart
93 Burner Orifice - LP See Orifice Selection Chart 93 Number of Orifices (2) (3) (4) (5) 95 Stk Flame Sensor 62-23543-02 62-23543-02 62-23543-02 62-23543-02 96 Stk Ignition Electrode/Cable Assembly 62-23556-01 62-23556-01 62-23556-01 62-23556-01
MODEL TECHNICALVARIATION HEATING CAPACITY
HEAT EXCHANGER, BURNER / MANIFOLD
Limit - Manual Reset (Burner Compartment) - Before approximate Date Code F3708 (See Note 3) Limit - Manual Reset (Burner Compartment) - After approximate Date Code F3708 (See Note 3) Burner Tube w/Shield (Inshot) - Beforeapproximate Date Code F3708 (See Note 3) Burner Assembly (One-piece) - After approximate Date Code F3708 (See Note 3) Burner Support Bracket (2) - Before approximate Date Code F3708 (See Note 3) Burner Support Bracket (2) - After approximate Date Code F3708 (See Note 3) Burner Support - (Holds Burners between Burner Support Brackets) ­Before approximateDate Code F3708 (See Note 3) Burner Support - (Holds Burners between Burner Support Brackets) ­After approximate Date Code F3708 (See Note 3)
RRNA
B
04
AE-58591-02
(2)
47-23610-11
(All)
56-42753-11
(024/030)
56-42753-11
(036/042)
75-23684-01
(2)
47-100241-01 47-100241-01 47-100241-01 47-100241-01
47-22861-02 47-22861-02 47-22861-02 47-22861-02 75-22840-02
(2)
AS-60993-02 AS-60993-03 AS-60993-04 AS-60993-05
AE-61588-01 AE-61588-01 AE-61588-01 AE-61588-01
AE-61588-02 AE-61588-02 AE-61588-02 AE-61588-02
AE-58592-02 AE-58592-02 AE-58592-02 AE-58592-02
AE-102438-01 AE-102438-01 AE-102438-01 AE-102438-01
81-23593-01
(3)
RRNA
B
06
AE-58591-02
(3)
47-23610-05
(024)
47-23610-03
(030-048)
56-42753-05
(024)
56-42753-03
(030-042)
75-23684-01
(3)
75-22840-02
(3)
81-23593-01
(2)
RRNA
B
08
AE-58591-02
(4)
47-23610-03
(All)
56-42753-03
(024-042)
56-42753-03
(048)
75-23684-01
(4)
75-22840-02
(4)
81-23593-01
(1)
RRNA
B
10
AE-58591-02
(5)
47-23610-03
(060)
47-23610-01
(030-048)
56-42753-01
(030-048)
56-42753-03
(060)
75-23684-01
(5)
75-22840-02
(5)
N/A
Page 12 of 25
07-April-2015
92-42800-RRNA-B
No. Notes
39 Stk Integrated Furnace Control Board (IFC) 62-23599-02 62-23599-02 62-23599-02 62-23599-02 62-23599-04
Stk GasValve- Natural Gas 60-105055-01 60-23490-03 60-23490-01 60-24290-01 60-105055-01
Stk,1 Gas Valve - LP See Note 1 See Note 1 See Note 1 See Note 1 See Note 1
Stk LPConversion Kit EP-85H EP-84W EP-84W EP-84W EP-85H
No. Notes
Economizer - Downflow, 3 Position RXRE-CAA30
Economizer - Downflow, Fully Modulating RXRD-CAM10
Fresh Air Damper - Fixed, 35% RXRF-FAA1
Fresh Air Damper - Motorized, 35% RXRF-FAB1
Filter Kit RXRY-B01
Low Ambient Control RXRZ-A18
High Pressure Control RXAB-A02
Low Pressure Control RXAC-A02
Canadian High Altitude Kit - Natural Gas Only RXRX-AH01
MODEL TECHNICALVARIATION GAS CODE
GAS CONTROLS
MODEL SIZE
OPTIONS AND ACCESSORIES
RRNA
B
1R
RRNA
ALL
RRNA
B
1S
RRNA
B
1X
RRNA
B
2A
RRNA
B
2G
Page 13 of 25
07-April-2015
92-42800-RRNA-B
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on a Natural Gas heating value of 1075 BTU/cu. ft and a pressure setting of 3.5 in. water column. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 2000 ft.
Furnace
Input
Rating (BTU/HR)
40,000 36,000 2 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 60,000 54,000 3 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 72,000 N/A 4 62-22175-15 62-22175-49 62-22175-50 62-22175-51 62-22175-15 N/A 80,000 72,000 4 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15
90,000 N/A 5 62-22175-15 62-22175-49 62-22175-50 62-22175-51 62-22175-15 N/A 100,000 90,000 5 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 120,000 108,000 6 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 135,000 121,500 6 62-22175-44 62-22175-45 62-22175-47 62-22175-48 62-22175-44 62-22175-45 150,000 135,000 6 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 180,000 N/A 9 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 210,000 N/A 9 62-22175-43 62-22175-44 62-22175-45 62-22175-47 62-22175-43 N/A 210,000 N/A 10 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 225,000 202,500 9 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 250,000 225,000 10 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 252,000 225,000 9 62-22175-40 62-22175-42 62-22175-43 62-22175-44 62-22175-40 62-22175-42 252,000 N/A 12 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 290,000 N/A 14 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 300,000 270,000 12 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 330,000 N/A 14 62-22175-43 62-22175-44 62-22175-45 62-22175-47 62-22175-43 N/A 350,000 315,000 14 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 400,000 360,000 14 62-22175-40 62-22175-42 62-22175-43 62-22175-44 62-22175-40 62-22175-42
CAUTION: Selection of the correct LP Orifice requires the following information for the specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and CANB149.1. NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on a heating value of 2500 BTU/cu. ft. and an elevation of 0 - 2000 ft.
Furnace
Input
Rating (BTU/HR)
40,000 36,000 2 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
60,000 54,000 3 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
72,000 N/A 4 62-22175-13 62-22175-57 62-22175-57 62-22175-59 62-22175-13 N/A
80,000 72,000 4 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
90,000 N/A 5 62-22175-13 62-22175-57 62-22175-57 62-22175-59 62-22175-13 N/A 100,000 90,000 5 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13 120,000 108,000 6 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13 135,000 121,500 6 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-55 150,000 135,000 6 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 180,000 N/A 9 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 210,000 N/A 9 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 N/A 210,000 N/A 10 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 225,000 202,500 9 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 250,000 225,000 10 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 252,000 225,000 9 62-22175-53 62-22175-54 62-22175-54 62-22175-55 62-22175-53 62-22175-54 252,000 N/A 12 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 290,000 N/A 14 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 300,000 270,000 12 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 330,000 N/A 14 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 N/A 350,000 315,000 14 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 400,000 360,000 14 62-22175-53 62-22175-54 62-22175-54 62-22175-55 62-22175-53 62-22175-54
Canadian High
Altitude Derated
Input
(BTU/HR)
Canadian High
Altitude Derated
Input
(BTU/HR)
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - NATURAL GAS
Number
of
Burners
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - LP
Number
of
Burners
0 - 2000
U.S.
0 - 2000
U.S.
2001 - 4000
U.S.
2001 - 4000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Country
8000+
U.S.
Country
8000+
U.S.
0 - 2000 Canada
0 - 2000 Canada
2001 - 4500
Canada
2001 - 4500
Canada
07-April-2015
92-42800-RRNA-B
Page 14 of 25
Exploded View
Page 15 of 25
07-April-2015
92-42800-RRNA-B
Control Access Panel Detail
Page 16 of 25
07-April-2015
92-42800-RRNA-B
Electrical Control Box
Page 17 of 25
07-April-2015
92-42800-RRNA-B
Blower Assembly
Page 18 of 25
07-April-2015
92-42800-RRNA-B
Evaporator Coil Assembly
Page 19 of 25
07-April-2015
92-42800-RRNA-B
Condenser Coil
Page 20 of 25
07-April-2015
92-42800-RRNA-B
Compressor and Refrigeration Components
Page 21 of 25
07-April-2015
92-42800-RRNA-B
Heat Exchanger Assembly
Page 22 of 25
07-April-2015
92-42800-RRNA-B
Burner Assembly (Inshot - Before Approx F3708)
Page 23 of 25
07-April-2015
92-42800-RRNA-B
Burner Assembly (One-piece - After Approx F3708)
Page 24 of 25
07-April-2015
92-42800-RRNA-B
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order GasValve for Natural Gas along with LP Conversion Kit. 2 This kit includes all necessary items to retrofit units using individual burner tubes with the later one-piece burner
design.
3 The date code shown is approximate. It should be confirmed by the servicing technician as to whether the unit was
manufactrured using the later one-piece burner design or the earlier inshot individual burner tubes. Components are NOT interchangeable.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document 92-42800-RRNA-B supersedes all previous parts lists for these models. See http://www.rheempartslists.net/92-42800-RRNA-B for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components.