1. All models feature Copeland®Scroll®compressors for maximum efficiency and quiet operation.
2. Louvered condenser compartment for protecting the coil
against yard hazards and/or weather extremes.
3. One-piece top with a deep flange to help keep water out of
the unit.
4. Supply and return air openings feature a one-inch tall flange
to prevent water migration into the ductwork.
5. Access panels have “weep holes” and channels to further
help manage water run-off.
6. Side and down discharge options available on all models.
7. Easily accessible blower section complete with slide-out
blower. All units feature a system matched MultiFlex
®
coil
with low static pressure drop and excellent cooling capacities.
8. Refrigerant connections are conveniently located for easy
service diagnostics.
9. Condenser and evaporator coils feature enhanced fins for
better heat transfer and rifled copper tubing for greater
efficiency.
10. Inside the easily accessible furnace compartment is the draft
inducer motor. This motor is specially designed for quiet
reliable operation. In addition to the draft inducer motor, the
in-shot gas burners and manifold efficiently regulate the flow
of gas for combustion. These new gas/electric units also
feature direct-spark ignition and remote flame sensors for
added reliability and efficiency.
11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap.
12. Easily accessible control box.
13. Single point wiring makes installation even easier.
14. Our gas/electric package units feature a tubular heat
exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. The heat exchanger is backed by a 10 year limited
warranty.
No. Used/Diameter in. [mm]1/20 [508]1/20 [508]1/20 [508]1/20 [508]
Drive Type/No. SpeedsDirect/1Direct/1Direct/1Direct/1
CFM [L/s]2730 [1288]2730 [1288]2730 [1288]2730 [1288]
No. Motors/HP1 at 1/5 HP1 at 1/5 HP1 at 1/5 HP1 at 1/5 HP
Motor RPM1075107510751075
No. Used/Diameter in. [mm]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]
Drive Type/No. SpeedsDirect/3Direct/3Direct/3Direct/3
No. Motors1111
Motor HP1/21/21/21/2
Motor RPM1725172517251725
Motor Frame Size48484848
No. Used/Diameter in. [mm]1/20 [508]1/20 [508]1/20 [508]1/20 [508]
Drive Type/No. SpeedsDirect/1Direct/1Direct/1Direct/1
CFM [L/s]2675 [1262]2675 [1262]2675 [1262]2675 [1262]
No. Motors/HP1 at 1/5 HP1 at 1/5 HP1 at 1/5 HP1 at 1/5 HP
Motor RPM1075107510751075
No. Used/Diameter in. [mm]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]
Drive Type/No. SpeedsDirect/3Direct/3Direct/3Direct/3
No. Motors1111
Motor HP1/21/21/21/2
Motor RPM1725172517251725
Motor Frame Size48484848
No. Used/Diameter in. [mm]1/20 [508]1/20 [508]1/20 [508]1/20 [508]
Drive Type/No. SpeedsDirect/1Direct/1Direct/1Direct/1
CFM [L/s]3200 [1510]3200 [1510]3200 [1510]2900 [1369]
No. Motors/HP1 at 1/3 HP1 at 1/3 HP1 at 1/3 HP1 at 1/3 HP
Motor RPM1075107510751075
No. Used/Diameter in. [mm]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]1/10x9 [254x228.6]
Drive Type/No. SpeedsDirect/3Direct/3Direct/3Direct/3
No. Motors1111
Motor HP3/43/43/43/4
Motor RPM1725172517251725
Motor Frame Size56565656
See Page 10 for Notes.[ ] Designates Metric Conversions
Page 10
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does
not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable
for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment
certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions
using American National Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations
above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
4. AFUE is rated in accordance with DOE test procedures.
5. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
[ ] Designates Metric Conversions
10
GENERAL DATA—RRKA- SERIES
Page 11
11
SYSTEMS PERFORMANCE—RRKA- SERIES
GROSS SYSTEMS PERFORMANCE DATA—RRKA-A036
GROSS SYSTEMS PERFORMANCE DATA—RRKA-A042
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
NOTE: On 4 ton models, switch to medium speed for cooling if external static pressure is less than 0.4" W.C. at 230 volts or less than 0.3" W.C. at 208 volts.
WARNING: Observe airflow operating limits if operating in area of airflow table shown in bold.
DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE)
Nominal Cooling Capacity Tons [kW]1.5 [5.28]2.0 [7.03]2.5 [8.79] – 4.0 [14.07]5.0 [17.59]
Minimum Filter Size—Inches [mm]16 x 20 x 1 [406 x 508 x 25] 20 x 20 x 1 [508 x 508 x 25]24 x 24 x 1 [610 x 610 x 25]24 x 30 x 1 [610 x 762 x 1]
NOTE: On 4 ton models, switch to medium speed for cooling if external static pressure is less than 0.4" W.C. at 230 volts or less than 0.3" W.C. at 208 volts.
WARNING: Observe airflow operating limits if operating in area of airflow table shown in bold.
2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.
Page 16
[ ] Designates Metric Conversions
UNIT DIMENSIONS
GAS HEAT/ELECTRIC
COOLING PACKAGE
3-4 TON [10.6-14.07 kW] MODELS
5 TON [17.59 kW] MODEL
16
UNIT DIMENSIONS—RRKA- SERIES
Page 17
17
TYPICAL INSTALLATIONS
Page 18
COMMON SUPPLY/RETURN
CONCENTRIC AIR DIFFUSER
SUPPLY AIR/PERFORMANCE
NOTE: The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomfortable conditions.
ACCESSORY EQUIPMENT
Designed to convert a side by side or an over and under arrangement into a concentric distribution of air. The diffuser is flush
mounted, completely insulated, assembled, and internally baffled
to provide four way supply air distribution with a center return. To
make the assembly complete and ready to fit into a 2' [0.61 m] x
4' [1.22 m] suspended ceiling grid, the diffuser includes
adjustable supply louvers, hanging rings, anti-sweat gasket, and
round flanges for use with flexible ducts.
SUPPLY/RETURN DIFFUSER
AIRFLOW/PRESSURE DROP
INFORMATION (INCHES W.C. [kPa])
NOTE: The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomfortable conditions.
*If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft. [609.6 m] in Canada, the existing Natural Gas to LP Conversion Kits for the
subject models already contain the necessary orifices and instructions to de-rate the input for 2000-4500 ft. [609.6-1371.6 m] Canadian applications.
[ ] Designates Metric Conversions
18
ACCESSORIES
Accessory
Description
RoofcurbsRRKA
Supply & Return DiffusersRRKARXRN-BD15
Economizers (Downflow ONLY)RRKA
Fresh Air DamperRRKA
Rectangular to Round Transition (Downflow)RRKA
Filter KitRRKARXRY-B01
Low Ambient ControlRRKARXRZ-A18
High Pressure ControlRRKARXAB-A02
Low Pressure ControlRRKARXAC-A02
Sideflow Rectangular to Round TransitionRRKARXMC-BA01
LP Conversion KitsRRKA
Canadian High Altitude Kit (for Natural Gas only*)RRKARXRX-AH01
DUCT ADAPTERS
RECTANGULAR TO ROUND
TRANSITIONS (DOWNFLOW)
RXMC-CA03
RXMC-CA02
[ ] Designates Metric Conversions
19
ACCESSORIES
Page 20
[ ] Designates Metric Conversions
ECONOMIZERS
RXRE-CAA30 (3 Position) and
RXRD-CAM10 (Fully Modulating) for
RRKA- Series
RXRE-CAA30 (3 Position)
Provided with enthalpy control, and
mixed air sensor. Settings include
fully open, fully closed and adjustable
mid point.
RXRD-CAM10 (Fully Modulating)
Provided with enthalpy control, mixed
air sensor and minimum position potentiometer for proportioning (modulating)
the amount of fresh air.
NOTE: See economizer installation instructions for correct filter access door.
RXRF-FAA1 (Fixed - 0-35%)
The 0-35% manual outside Air Damper is designed to replace the
unit return air duct cover. No drilling or damper assembly is
required. The amount of outside air (0-35%) is controlled by simply adjusting the side damper.
RXRF-FAB1 (Motorized - 0-35%)
The 0-35% motorized outside Air Damper is designed to replace
the unit return air duct cover. No drilling or damper assembly is
required. The control motor opens the adjustable slide damper
when the unit blower motor is energized.
FRESH AIR DAMPER FOR USE ON
RRKA- SERIES
[ ] Designates Metric Conversions
20
ACCESSORIES
Page 21
FILTER KIT INSTALLATION
RXRY-B01
For use in either
vertical or horizontal
discharge.
DUCT ADAPTER SIDEFLOW
SQUARE TO ROUND TRANSITION
RXMC-BA01
Adapts the side rectangular supply and return openings to 14"
[356 mm] diameter round openings. Adapters provided with same
finish as unit and also provided with thermal insulation.
22
ACCESSORIES
Page 23
RXSG-AAA14
(14" [356 mm] High)
RXSG-AAA08
(8" [203 mm] High)
ROOFCURB (Full Perimeter)
RXSG-AAA08, RXSG-AAA14
and RXSG-AAA24 for
RRKA- Series
Hinged corners make for
fast, easy set-up.
NOT for use with
RQKA/RQLA/RQMA
Package Heat Pumps.
[ ] Designates Metric Conversions
23
ACCESSORIES
Page 24
ROOFCURB (Full Perimeter) (Cont.)
[ ] Designates Metric Conversions
RXSG-AAA24
(24" [610 mm] High)
24
ACCESSORIES
Page 25
[ ] Designates Metric Conversions
SELF CONTAINED AIR CONDITIONERS &
GAS/ELECTRIC PACKAGE UNITS
ROOFCURB INSTALLATION (Full Perimeter)
ROOFCURB ADAPTERS
Fabricated from galvanized steel to adapt the New cabinet to
the old style curb. All are furnished with a New gasket.
The lift kit is intended for temporary installation while the unit is
being lifted into position. Kit includes 4 lift brackets.
26
ACCESSORIES
Page 27
27
WIRING SCHEMATICS—RRKA- SERIES
Page 28
GENERAL TERMS OF LIMITED WARRANTY
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
RHEEM
AIR CONDITIONING
DIVISION
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A.4-06 DCFORM NO. R11-834 REV. 3
Supersedes Form No. R11-834 Rev. 2
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM
YOUR RETAILER.
Factory Standard Heat Exchanger..................Ten (10) Years
Factory Option Stainless Steel Heat Exchanger
Three Phase models installed in a
commercial application ........................Twenty (20) Years
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
*Condenser Coil and Evaporator Coil leaks
caused by factory defects ..........................Five (5) Years
*Compressor (3 Phase models) ......................Five (5) Years
*Any Other Part ..............................................One (1) Year
*All other parts and components carry a limited warranty of five years,
provided they are single-phase products installed in a residential
application.
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods
stated, in accordance with the terms of the limited warranty.