R C (–) (–) –36** A U 17 A OPT
2
TABLE OF CONTENTS
Model Number.....................................................................2
Unit Specifications............................................................3,4
Coil Application ...........................................................5, 6, 7
I. Inspection............................................................................8
II. General Information ............................................................8
Codes/Regulations..............................................................8
Replacement Parts..............................................................8
III. Installation...........................................................................8
Vertical Upflow/Downflow....................................................8
Horizontal............................................................................8
Refrigerant Connections .....................................................9
Flowcheck Pistons ..............................................................9
Condensate Drain Tubing...................................................9
IV. Maintenance........................................................................9
Air Filter.............................................................................10
Indoor Coil ........................................................................10
V. Accessories.......................................................................10
Internal Coupler Accessory ..............................................10
Plenum Adapter Accessory...............................................10
Horizontal Drain Pan Kit....................................................10
VARIATION
BLANK = NONE
M = REVISED HORIZONTAL
J = REVISED HORIZONTAL W/INSULATION
VARIATION
BLANK = NONE
A = FILTER/FILTER RACK
B = ADAPTERS (78% FURNACE)
X = IF UNIT HAS INSULATION
COIL CASING
14 = 14" 21 = 21"
17 = 17
1
⁄2" 24 = 241⁄2"
CABINET WIDTH
14 = 14" 21 = 21"
17 = 17-1/2" 24 = 24-1/2"
AIRFLOW/REFRIGERANT CONNECTION
“A” CONNECTION U = UPFLOW, DOWNFLOW - LEFT (STD)
D = UPFLOW, DOWNFLOW - RIGHT
L = HORIZONTAL (LEFT) - TOP
R = HORIZONTAL (RIGHT) - TOP
S = UPFLOW/DOWNFLOW - LEFT OR RIGHT
“G” CONNECTION G = UPFLOW/DOWNFLOW/FRONT
H = HORIZONTAL - (LEFT)/FRONT
Z = HORIZONTAL - (RIGHT)/FRONT
CONNECTION (REFRIGERANT)
A = SIDE
G = FRONT
METERING DEVICE (CODE)
**
= TX VALVE OR FLOWCHECK SIZE
TX VALVE (e.g. A1)
FLOWCHECK (e.g. 99 FOR .099
PISTON SIZE)
NOMINAL CAPACITY
24 = 18,000 TO 24,000 BTUH
36/37 = 30,000 TO 36,000 BTUH
48 = 42,000 TO 48,000 BTUH
60 = 60,000 BTUH
(ACTUAL CAPACITY IS DEPENDENT UPON
METERING DEVICE AND SYSTEM
COMBINATION. SEE OUTDOOR UNIT
INSTRUCTIONS FOR SPECIFICATIONS.)
DESIGN SERIES
A = 1ST DESIGN
J = 14 SEER SYSTEM (1ST DESIGN)
DESIGN SERIES
A = SIDE CONNECTION
C = FRONT CONNECTION
TYPE OF COIL
B = FLOWCHECK (COOLING/HEAT PUMP)
G = EXPANSION VALVE (COOLING ONLY)
H = EXPANSION VALVE (HEAT PUMP ONLY)
COIL
TRADE NAME
TRADE NAME
ACCESSORY
BLOWER UNIT
COIL CASING
RXBC - INDOOR COIL CASING
RCBA - CASED OR UNCASED INDOOR COILS
R X B C –A14
*NOTE!! UNCASED COIL MODEL NUMBERS END AFTER 10TH POSITION (REF. ASTERISK)
RCGA COILS
COIL TXV TXV PISTON
SIZE CODE SIZE SIZE
24 A1 1 1/2 .099
24 A2 2 .120
37 A1 2 1/2 .140
36 A2 3 .157
48 A1 3 1/2 & 4 .157
60 A1 5 .172
RCHA COILS
24 A1 1 1/2 .099
24 A2 2 .120
36 A1 2 1/2 & 3 .157
48 A1 3 1/2 & 4 .157
60 A1 5 .172
RCGJ COILS
24 A1 1 1/2 .099
24 A2 2 .120
36 A1 2 1/2 .120
36 A2 3 .140
48 A1 3 1/2 .140
60 A1 4 & 5 .157
60 A2 5 .172
RCHJ COILS
24 A1 1-1/2 0.099
24 A2 2 0.120
36 A1 2-1/2 0.140
36 A2 3 0.140
48 A1 4 0.140
48 A2 4 .157
60 A1 5 .172
51 A1 COIL A = 3 0.120
COIL B = 1.5 0.086
61 A1 COIL A = 4 0.140
COIL B = 1.5 0.086
RCHL COILS
24 A2 1-1/2 & 2 0.099
36 A1 2 0.099
36 A2 3 0.120
48 A1 3 0.120
48 A2 3 0.120
60 A1 4 0.140