Rheem RQKA, RQMA User Manual

FORM NO. P11-751 REV. 1
Supersedes Form No. P11-751
RQKA- STANDARD EFFICIENCY 10-SEER SERIES
NOMINAL SIZES 1.5-4 TONS [5-14.1 kW]
RQMA- HIGH EFFICIENCY 12-SEER SERIES
NOMINAL SIZES 1.5-3 TONS [5-10.6 kW]
SELF-CONTAINED HEAT PUMP PACKAGE UNITS
RQMA- MODELS ONLY
2
TABLE OF CONTENTS
Unit Features & Benefits ................................................................................3-4
Model Identification Options............................................................................5-6
General Data
RQKA- Series ............................................................................................7-9
RQMA- Series........................................................................................10-11
General Data Notes ........................................................................................12
Performance Data
RQKA- Series ........................................................................................13-15
RQMA- Series........................................................................................16-17
Airflow Performance
RQKA- Series ........................................................................................18-19
RQMA- Series ............................................................................................20
Electrical Data
RQKA- Series ............................................................................................21
RQMA- Series ............................................................................................22
Electric Heater Kits ....................................................................................23-26
Dimensional Data ..........................................................................................27
Typical Installations ........................................................................................28
Accessories ..............................................................................................29-36
Typical Wiring............................................................................................37-38
Limited Warranty ............................................................................................40
UNIT FEATURES & BENEFITS—RQKA/RQMA-
These quality features are included in the Rheem Outdoor Package Heat Pumps
4
5
3
4
UNIT FEATURES & BENEFITS—RQKA/RQMA- SERIES
1. All models feature Copeland®Scroll®compressors for maximum efficiency and quiet operation.
2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes.
3. One-piece top with a deep flange to help keep water out of the unit.
4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork.
5. Access panels have “weep holes” and channels to further help manage water run-off.
6. Side and down discharge options available on all models. (Shipped Downflow Standard).
7. Easily accessible blower section complete with slide­out blower. All units feature a system matched MultiFlex
®
coil with low static pressure drop and
excellent cooling capacities.
8. Refrigerant connections are conveniently located for easy service diagnostics.
9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency.
10. Supplemental electric heat strips up to 15 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring makes installation even easier.
11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap.
12. Integral gasketing on the base rails is standard on those units shipped from the factory in the down-flow configuration.
13. Easily accessible control box.
Features Below Correspond to Photos on Page 3
5
MODEL IDENTIFICATION—RQKA/RQMA- SERIES
RQKA—A036JK 010XXX
Future Option
Factory Installed Options (See Next Page)
Heating Capacity (Factory Installed)
000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 006 = 06 KW Resistance Heat (036-048) 010 = 10 KW Resistance Heat (024-048) 011 = 10 KW Resistance Heat (Canada)
(024-048) 015 = 15 KW Resistance Heat (036-048) 016 = 15 KW Resistance Heat (Canada)
(036-048)
Drive Package K = Direct Drive
Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH—60 Hz
Cooling Capacity (BTUH) [kW]
018 = 18,000 [5.28] 024 = 24,000 [7.03] 030 = 30,000 [8.79] 036 = 36,000 [10.55] 042 = 42,000 [12.31] 048 = 48,000 [14.07] 060 = 60,000 [17.59]
Future Technical Variations
Design Series A = 1st Design
Efficiency Designation K = 10 SEER Standard Efficiency M = 12 SEER High Efficiency
Product Classification Q= Package Heat Pump
Tra d eb ra nd R= Rheem
[ ] Designates Metric Conversions
6
OPTIONS—RQKA/RQMA- SERIES
FACTORY INSTALLED OPTION CODES
Example: RQKA-A036JK000XX (where XX is factory installed option) Example: No Options
RQKA-A036JK000
Example: Options with Sideflow
RQKA-A036JK000AKA
Note: Factory installed economizer is not available on these models.
Instructions for Factory Installed Option(s) Selection
Note: Two characters following the model number will be utilized to designate a factory-installed option or com-
bination of options. If no factory option(s) is required, nothing follows the model number.
Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY
INSTALLED OPTION SELECTION TABLE.
Option
Code
AA No Option
AKA x
Side Flow
7
GENERAL DATA—RQKA- SERIES
NOMINAL SIZES 1.5-4 TONS [5-14.1 kW]
Model RQKA- Series A018JK A024JK A030JK A036CK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 18,600 [5.4] 24,000 [7] 31,200 [9.1] 37,200 [10.9] EER/SEER
2
10.15/10 9.5/10 9.1/10 9.5/10 Nominal CFM/ARI Rated CFM [L/s] 600/600 [283/283] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] ARI Net Cooling Capacity Btu [kW] 18,000 [5.3] 23,200 [6.8] 30,000 [8.8] 36,000 [10.5] Net Sensible Capacity Btu [kW] 13,200 [3.9] 17,200 [5] 21,400 [6.3] 25,200 [7.4]
Net System Power kW 1.8 2.4 3.3 3.8
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 18,000 [5.3] 23,600 [6.9] 29,600 [8.7] 36,000 [10.5] System Power KW/COP 1.7/3.18 2.1/3.24 2.8/3.08 3.4/3.12 Low Temp. Btuh [kW] Rating 9400 [2.8] 12,600 [3.7] 16,400 [4.8] 21,600 [6.3]
Net Weight lbs. [kg] 360 [163] 362 [164] 389 [176] 405 [184]
System Power KW/COP 1.5/1.8 1.9/1.9 2.5/1.9 3.2/2
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
HSPF (Btu/Watts-hr) 6.8 6.8 6.8 6.8
Compressor
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)
3
76 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Smooth Smooth Smooth Smooth Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 12.75 [1.18] 12.75 [1.18] 12.75 [1.18] 12.42 [1.15] Rows / FPI [FPcm] 1 / 18 [7] 1 / 20 [8] 1 / 18 [7] 2 / 18 [7]
Net Latent Capacity Btu [kW] 4800 [1.4] 6000 [1.8] 8600 [2.5] 10,800 [3.2]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] Face Area sq. ft. [sq. m] 7.6 [0.71] 7.6 [0.71] 10.13 [0.94] 10.13 [0.94] Rows / FPI [FPcm] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] Refrigerant Control Orifices Orifices Orifices TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [559] 1/22 [559] 1/22 [559] 1/22 [559] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 1800 [849] 1800 [849] 2730 [1288] 2600 [1227] No. Motors/HP 1 at 1/15 HP 1 at 1/15 HP 1 at 1/5 HP 1 at 1/5 HP Motor RPM 1075 1075 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/9x7 [228.6x177.8] 1/9x7 [228.6x177.8] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/1 No. Motors 1 1 1 1 Motor HP 1/4 1/4 1/2 1/3 Motor RPM 1075 1075 1075 1075 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x20x16 [25x508x406] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 65 [1843] 62 [1758] 70 [1984] 103 [2920] Weights
Ship Weight lbs. [kg] 400 [181] 402 [182] 429 [195] 445 [202]
CONTINUED
See Page 12 for Notes. [ ] Designates Metric Conversions
8
GENERAL DATA—RQKA- SERIES
Model RQKA- Series A036JK A042CK A042JK A048CK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 37,200 [10.9] 42,000 [12.3] 48,500 [14.2] 48,500 [14.2] EER/SEER
2
9.5/10 9.1/10 9.1/10 9/10 Nominal CFM/ARI Rated CFM [L/s] 1200/1200 [566/566] 1400/1400 [661/661] 1400/1400 [661/661] 1600/1500 [755/708] ARI Net Cooling Capacity Btu [kW] 36,000 [10.5] 40,500 [11.9] 40,500 [11.9] 46,500 [13.6] Net Sensible Capacity Btu [kW] 25,200 [7.4] 29,000 [8.5] 29,000 [8.5] 32,100 [9.4]
Net System Power kW 3.8 4.5 4.5 5.2
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 36,000 [10.5] 41,000 [12] 41,000 [12] 48,000 [14.1] System Power KW/COP 3.4/3.12 3.9/3.1 3.9/3.1 4.6/3.08 Low Temp. Btuh [kW] Rating 21,600 [6.3] 22,600 [6.6] 22,600 [6.6] 28,000 [8.2]
Net Weight lbs. [kg] 409 [186] 416 [189] 420 [191] 441 [200]
System Power KW/COP 3.2/2 3.4/1.96 3.4/1.96 4/2.06
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
HSPF (Btu/Watts-hr) 6.8 6.8 6.8 6.8
Compressor
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)
3
76 76 76 78
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Smooth Smooth Smooth Smooth Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 12.42 [1.15] 12.42 [1.15] 12.42 [1.15] 12.42 [1.15] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7]
Net Latent Capacity Btu [kW] 10,800 [3.2] 11,500 [3.4] 11,500 [3.4] 14,400 [4.2]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] Face Area sq. ft. [sq. m] 10.13 [0.94] 10.13 [0.94] 10.13 [0.94] 10.13 [0.94] Rows / FPI [FPcm] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [559] 1/22 [559] 1/22 [559] 1/22 [559] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2600 [1227] 2600 [1227] 2600 [1227] 3000 [1416] No. Motors/HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/3 HP Motor RPM 1075 1075 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/1 Direct/2 Direct/2 Direct/3 No. Motors 1 1 1 1 Motor HP 1/3 1/2 1/2 3/4 Motor RPM 1075 1075 1075 1075 Motor Frame Size 48 48 48 56
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 103 [2920] 139 [3941] 139 [3941] 138 [3912] Weights
Ship Weight lbs. [kg] 449 [204] 456 [207] 460 [209] 481 [218]
CONTINUED
NOMINAL SIZES 1.5-4 TONS [5-14.1 kW]
See Page 12 for Notes. [ ] Designates Metric Conversions
9
GENERAL DATA—RQKA- SERIES
Model RQKA- Series A048JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 48,500 [14.2] EER/SEER
2
9/10 Nominal CFM/ARI Rated CFM [L/s] 1600/1500 [755/708] ARI Net Cooling Capacity Btu [kW] 46,500 [13.6] Net Sensible Capacity Btu [kW] 32,100 [9.4]
Net System Power kW 5.2
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 48,000 [14.1] System Power KW/COP 4.6/3.08 Low Temp. Btuh [kW] Rating 28,000 [8.2]
Net Weight lbs. [kg] 450 [204]
System Power KW/COP 4/2.06
Refrigerant Control TX Valves
HSPF (Btu/Watts-hr) 6.8
Compressor
No./Type 1/Copeland Scroll
Outdoor Sound Rating (dB)
3
78
Outdoor Coil—Fin Type Louvered
Tube Type Smooth Tube Size in. [mm] OD 0.375 [9.5] Face Area sq. ft. [sq. m] 12.42 [1.15] Rows / FPI [FPcm] 2 / 18 [7]
Net Latent Capacity Btu [kW] 14,400 [4.2]
Indoor Coil—Fin Type Louvered
Tube Type Rifled Tube Size in. [mm] 0.3125 [7.9] Face Area sq. ft. [sq. m] 10.13 [0.94] Rows / FPI [FPcm] 1 / 18 [7] Refrigerant Control TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05]
Outdoor Fan—Type Propeller
No. Used/Diameter in. [mm] 1/22 [559] Drive Type/No. Speeds Direct/1 CFM [L/s] 3000 [1416] No. Motors/HP 1 at 1/3 HP Motor RPM 1075
Indoor Fan—Type FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/1+B34 No. Motors 1 Motor HP 3/4 Motor RPM 1075 Motor Frame Size 48
Filter—Type Field Supplied
Furnished No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 138 [3912] Weights
Ship Weight lbs. [kg] 490 [222]
NOMINAL SIZES 1.5-4 TONS [5-14.1 kW]
See Page 12 for Notes. [ ] Designates Metric Conversions
10
GENERAL DATA—RQMA- SERIES
Model RQMA- Series A018JK A024JK A030JK A036CK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 19,600 [5.7] 25,000 [7.3] 30,200 [8.8] 36,600 [10.7] EER/SEER
2
10.5/12 10.6/12 10.2/12 10.5/12 Nominal CFM/ARI Rated CFM [L/s] 600/700 [283/330] 800/800 [378/378] 1000/1050 [472/495] 1200/1200 [566/566] ARI Net Cooling Capacity Btu [kW] 18,800 [5.5] 24,000 [7] 29,000 [8.5] 35,400 [10.4] Net Sensible Capacity Btu [kW] 14,000 [4.1] 17,000 [5] 21,400 [6.3] 25,300 [7.4]
Net System Power kW 1.8 2.3 2.8 3.4
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 18,800 [5.5] 24,000 [7] 29,000 [8.5] 35,800 [10.5] System Power KW/COP 1.7/3.1 2.2/3.2 2.7/3.1 3.2/3.3 Low Temp. Btuh [kW] Rating 10,400 [3] 13,500 [4] 16,000 [4.7] 20,200 [5.9]
Net Weight lbs. [kg] 383 [174] 395 [179] 405 [184] 405 [184]
System Power KW/COP 1.6/1.96 2/2 2.3/2 2.9/2.08
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
HSPF (Btu/Watts-hr) 7.2 7.2 7.2 7.2
Compressor
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)
3
76 76 76 76
Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Smooth Smooth Smooth Smooth Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] Face Area sq. ft. [sq. m] 12.42 [1.15] 12.42 [1.15] 12.42 [1.15] 12.42 [1.15] Rows / FPI [FPcm] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7] 2 / 18 [7]
Net Latent Capacity Btu [kW] 4800 [1.4] 7000 [2.1] 7600 [2.2] 10,100 [3]
Indoor Coil—Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] 0.3125 [7.9] Face Area sq. ft. [sq. m] 10.13 [0.94] 10.13 [0.94] 10.13 [0.94] 10.13 [0.94] Rows / FPI [FPcm] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] 1 / 18 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05]
Outdoor Fan—Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [559] 1/22 [559] 1/22 [559] 1/22 [559] Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2600 [1227] 2600 [1227] 2600 [1227] 2600 [1227] No. Motors/HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP Motor RPM 1075 1075 1075 1075
Indoor Fan—Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/9x7 [228.6x177.8] 1/9x7 [228.6x177.8] 1/10x9 [254x228.6] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2+D33 Direct/1 No. Motors 1 1 1 1 Motor HP 1/4 1/4 1/2 1/3 Motor RPM 1075 1075 1075 1075 Motor Frame Size 48 48 48 48
Filter—Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No (No.) Size Recommended in. [mm] (1)1x20x16 [25x508x406] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 112 [3175] 112 [3175] 119 [3374] 106 [3005] Weights
Ship Weight lbs. [kg] 423 [192] 435 [197] 445 [202] 445 [202]
CONTINUED
NOMINAL SIZES 1.5-3 TONS [5-10.6 kW]
See Page 12 for Notes. [ ] Designates Metric Conversions
11
GENERAL DATA—RQMA- SERIES
Model RQMA- Series A036JK Cooling Performance
1
Gross Cooling Capacity Btu [kW] 36,600 [10.7] EER/SEER
2
10.5/12 Nominal CFM/ARI Rated CFM [L/s] 1200/1200 [566/566] ARI Net Cooling Capacity Btu [kW] 35,400 [10.4] Net Sensible Capacity Btu [kW] 25,300 [7.4]
Net System Power kW 3.4
Heating Performance (Heat Pumps)
Heating Input Btu [kW] Rating 35,800 [10.5] System Power KW/COP 3.2/3.3 Low Temp. Btuh [kW] Rating 20,200 [5.9]
Net Weight lbs. [kg] 405 [184]
System Power KW/COP 2.9/2.08
Refrigerant Control TX Valves
HSPF (Btu/Watts-hr) 7.2
Compressor
No./Type 1/Copeland Scroll
Outdoor Sound Rating (dB)
3
76
Outdoor Coil—Fin Type Louvered
Tube Type Smooth Tube Size in. [mm] OD 0.375 [9.5] Face Area sq. ft. [sq. m] 12.42 [1.15] Rows / FPI [FPcm] 2 / 18 [7]
Net Latent Capacity Btu [kW] 10,100 [3]
Indoor Coil—Fin Type Louvered
Tube Type Rifled Tube Size in. [mm] 0.3125 [7.9] Face Area sq. ft. [sq. m] 10.13 [0.94] Rows / FPI [FPcm] 1 / 18 [7] Refrigerant Control TX Valves Drain Connection No./Size in. [mm] 1/0.75 [19.05]
Outdoor Fan—Type Propeller
No. Used/Diameter in. [mm] 1/22 [559] Drive Type/No. Speeds Direct/1 CFM [L/s] 2600 [1227] No. Motors/HP 1 at 1/5 HP Motor RPM 1075
Indoor Fan—Type FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] Drive Type/No. Speeds Direct/1 No. Motors 1 Motor HP 1/3 Motor RPM 1075 Motor Frame Size 48
Filter—Type Field Supplied
Furnished No (No.) Size Recommended in. [mm] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 106 [3005] Weights
Ship Weight lbs. [kg] 445 [202]
NOMINAL SIZES 1.5-3 TONS [5-10.6 kW]
See Page 12 for Notes. [ ] Designates Metric Conversions
12
GENERAL DATA—RQKA/RQMA- SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
[ ] Designates Metric Conversions