Rheem RKMB User Manual

Page 1
RKMB
Parts List
25-November-2015
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RKMB.pdf for the current revision.
Package Gas-Electric - Commercial
Page 2
Model Explanation.. .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... Page 3
Parts Numbers
Panels - Miscellaneous 090-150 (1). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ..... Page 4
Panels - Miscellaneous 090-150 (2). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ..... Page 5
Panels - Miscellaneous 180-240 (1). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ..... Page 6
Panels - Miscellaneous 180-240 (2). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ..... Page 7
Electrical Group (1). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 8
Electrical Group (2). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 9
Electrical Group (3). ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... . Page 10
Fan Group.. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... ....... ... ... ... ... ... ...... Page11
Coil Parts 090-150. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 12
Coil Parts 180-240. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 13
Blower Group 090-150 (1) . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... .......... ... Page 14
Blower Group 090-150 (2) . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... .......... ... Page 15
Blower Group 180-240. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... . Page 16
Compressor Group .. ... .......... ... ... ... ... .......... ... ... ... ... ... ....... ... ... ... ... ... .......... ... ... ... Page 17
Heat Exchanger-Burner Group 090-150 15-25 .. ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .. Page 18
Heat Exchanger-Burner Group 180 25-35 ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 19
Heat Exchanger-Burner Group 240 30-40 ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... .. Page 20
Accessories .. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .... Page 21
Gas Controls .. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ... Page22
Orifice Selection Chart.. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... .......... ... ... ... Page 23
Drawings/Photographs
Exploded View 090-150.. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... .. Page 24
Exploded View 180 240. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... Page 25
Filter Rack Assembly 090-150 . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... ...... Page 26
Coil Assembly 090-150 .. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... .. Page 26
Control Board Assembly 090-150 .. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... ..... Page 27
Blower Assembly 090-150 .. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... .. Page 27
Heat Exchanger Assembly 090-150. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .... Page 28
Heat Exchanger Assembly 180 240 ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ..... Page 29
Control Board Assembly 180 240 . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... ... Page29
Coil Assembly 180 240 . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... .......... ... ... Page 29
Blower Assembly 180 240 . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... .......... ... Page 30
Evaporator Coil Assembly 090-120.. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .... Page 31
Evaporator Coil Assembly 0150.. .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... ....... Page 31
Evaporator Coil Assembly 180-240.. ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .... Page 32
Notes/Disclaimer . ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... ... ... ... .......... ... ... ... ... .......... ... ... . Page 33
Page 2 of 33
25-November-2015
92-42800-RKMB
Page 3
MODEL NUMBER EXPLANATION
R K M B - A 0 9 0 C L 1 5 E 1 2 3 4 5 6 7 8 9 10
1 TRADENAME 7 ELECTRICAL DESIGNATION C = 208-230/3/60 2 K - ROOFTOP COMMERCIAL D = 460/3/60 N = 380-415/3/50 3 EFFICIENCY DESIGNATION P = 200-220/3/50 K = Standard Efficiency (10 SEER) Y = 575/3/60 M = High Efficiency (12 SEER) 8 DRIVE PACKAGE 4 DESIGN SERIES L = Belt Drive M = Belt Drive - High Static 5 TECHNICAL VARIATIONS 9 HEATING CAPACITY - (MBH) 6 COOLING CAPACITY (BTU/HR) 12 = 120,000 29 = 290,000 090 = 90,000 180 = 180,000 15 = 150,000 30 = 300,000
102 = 102,000 240 = 240,000 18 = 180,000 33 = 330,000 120 = 120,000 21 = 210,000 35 = 350,000 150 = 150,000 22 = 225,000 40 = 400,000 25 = 252,000
10 IGNITION SYSTEM E = Electric
SERIAL NUMBER EXPLANATION
1 Z A 1 2 3 4 A A A F 2 6 9 9 9 9 9 9 9
1 2 3 4 5 6 7 8 9
1 GAS CODE 6 TECHNOLOGYVARIATIONS 2 COMPRESSOR IDENTIFICATION NO. 7 PRODUCTION LOCATION
F = Fort Smith, AR 3 IGNITION DEVICE 8 DATE CODE 4 INDUCER BLOWER 9 PRODUCTION NUMBER 5 HEAT EXCHANGER
Page 3 of 33
25-November-2015
92-42800-RKMB
Page 4
No. Notes
BASE RAILS: A Front AE-90575-03 AE-90575-03 B Right AE-90576-03 AE-90576-03 C Rear AE-90575-04 AE-90575-04 D Left AE-90576-04 AE-90576-04
BASE PANS: E Outdoor Coil Base Pan AS-90577-03 AS-90577-05 F Indoor Coil Base Pan AS-90577-02 AS-90577-02
INSIDE CABINET PANEL/PIECES: G Entry Plate AE-90614-02 AE-90614-02 H Entry Plate AE-90614-01 AE-90614-01 J Heat Compartment Side AE-90598-03 AE-90598-03 K Blower Deck AS-90592-02 AS-90592-02 L Wireway AE-90718-02 AE-90718-02 M Condenser Bulkhead AS-90609-03 AS-90609-06 N Tube Support Right Angle AE-90600-02 AE-90600-02 P Tube Support Left Angle AE-90600-01 AE-90600-01 R Limit Cover AS-59152-01 AS-59152-01
No. Notes
FRONT: 1 Control Box / Filter Access Panel AS-90678-02 AS-90678-02 2 Hinge 64-42546-03 64-42546-03 3 Hinge 64-42546-04 64-42546-04 4 Left - Front Panel AS-90620-07 AS-90620-07 5 Control Box Cover AE-90713-02 AE-90713-02 6 Control Mounting Plate AE-90712-02 AE-90712-02 7 Low VoltageShield AE-90742-02 AE-90742-02 8 Control Box Back AS-90601-02 AS-90601-02 9 Bracket AE-90779-02 AE-90779-02
10 Inlet Flue Hood (2) AE-90745-01 AE-90745-01
11 Flue Hood AS-90637-02 AS-90637-02 12a Gas Furnace Access Panel AS-90715-02 AS-90715-02 12b Hinge 64-42546-04 64-42546-04 12c Hinge 64-42546-03 64-42546-03
13 Gas Pipe Support Plate AS-90774-01 AS-90774-01
14 Blower Access Panel AS-90622-02 AS-90622-02
15 Right - Front Panel AS-90620-06 AS-90620-06
16 Heat Exchanger Mounting Frame AS-90754-01 AS-90754-01
17 Condenser Coil Access Panel-Front AE-90631-03 AE-90631-04
18 Front Corner Post AE-90701-02 AE-90701-02
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS, MISCELLANEOUS PARTS
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS - FRONT
RKMB
A
090/102
RKMB
A
090/102
RKMB
A
120/150
RKMB
A
120/150
Page 4 of 33
25-November-2015
92-42800-RKMB
Page 5
No. Notes
RIGHT: 19 Air Stop AE-90760-01 N/A AE-90760-01 N/A 20 Louvered Panel AS-90789-01 AS-90789-01 AS-90789-01 AS-90789-01
REAR: 21 Rear Corner Post AE-90702-03 AE-90702-03 AE-90702-03 AE-90702-03 22 Condenser Coil Access Panel - Rear AE-90631-03 AE-90631-03 AE-90631-03 AS-90683-04 23 Rear Panel AS-90618-02 AS-90618-02 AS-90618-02 AS-90618-02 24 Supply Cover AS-90626-02 AS-90626-02 AS-90626-02 AS-90626-02 25 Return Cover AS-90628-02 AS-90628-02 AS-90628-02 AS-90628-02
LEFT: 26 Upper Left Panel AS-90624-03 AS-90624-03 AS-90624-03 AS-90624-03 27 Lower Left Panel AS-90624-04 AS-90624-04 AS-90624-04 AS-90624-04 28 Left Corner Panel AS-90755-02 AS-90755-02 AS-90755-02 AS-90755-02 29 Receptacle Plate-Inside Panel AE-90756-02 AE-90756-02 AE-90756-02 AE-90756-02 30 Disconnect Plate-Install Panel AE-90756-03 AE-90756-03 AE-90756-03 AE-90756-03 31 Button Plug (2) 45-22980-06 45-22980-06 45-22980-06 45-22980-06 32 Button Plug 45-22980-05 45-22980-05 45-22980-05 45-22980-05
TOP: 33 Top Panel AS-90616-02 AS-90616-02 AS-90616-02 AS-90616-02 34 Condenser Top Panel AS-90703-02 AS-90703-02 AS-90703-02 AS-90703-02 35 Venturi (2) AE-90632-01 AE-90632-01 AE-90632-01 AE-90632-01 36 Wire Grille (2) 95-42507-01 95-42507-01 95-42507-01 95-42507-01
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS - RIGHT, REAR AND LEFT SIDES
RKMB
A
090
RKMB
A
102
RKMB
A
120
RKMB
A
150
Page 5 of 33
25-November-2015
92-42800-RKMB
Page 6
No. Notes
BASE RAILS:
A Front AS-90827-01 AS-90827-01 B Right AE-90576-03 AE-90576-03 C Rear AS-90827-01 AS-90827-01 D Left AE-90576-04 AE-90576-04
BASE PANS:
E Outdoor Base Pan AS-90577-06 AS-90577-06 F Indoor Coil Base Pan - Return Air AS-90578-04 AS-90578-04 G Indoor Coil Base Pan - SupplyAir AS-90578-03 AS-90578-03
INSIDE CABINET PANEL/ PIECES:
H Entry Plate (2) AE-90614-01 AE-90614-01 J Heat Compartment Side AE-90598-03 AE-90598-03 K Blower Deck AS-90592-05 AS-90592-05 L Wireway AE-90718-03 AE-90718-03 M Condenser Bulkhead AS-90609-08 AS-90609-08 N Tube Support Right Angle (2) AE-90600-02 AE-90600-02 R Limit Cover AS-59152-01 AS-59152-01 S Air Stop - Outdoor Coil-Front AE-90706-08 AE-90706-08 T Air Stop - Outdoor Coil- Rear AE-90706-07 AE-90706-07 U Coil Mounting Angle(2) AE-90706-05 AE-90706-05
W Outdoor Coil Divider Panel AE-90735-03 AE-90735-03
X Coil Support Brace AE-90706-01 AE-90706-01 Y Condenser Coil- Air Stop Rear AE-90753-04 AE-90753-04 Z Condenser Coil- Air Stop Front AE-90753-03 AE-90753-03
No. Notes
1 Control Box / Filter Access Panel AS-90678-03 AS-90678-03 2 Hinge 64-42546-03 64-42546-03 3 Hinge 64-42546-04 64-42546-04 4 Left - Front Panel AS-90620-11 AS-90620-11 5 Control Box Cover AE-90713-03 AE-90713-03 6 Control Mounting Plate AE-90712-03 AE-90712-03 7 Low VoltageShield AE-90742-04 AE-90742-04 8 Control Box Back AS-90601-03 AS-90601-03
9 Bracket AE-90779-02 AE-90779-02 10 Inlet Flue Hood (4) AE-90745-01 AE-90745-01 11 Flue Hood (2) AS-90637-02 AS-90637-02
12a Gas Furnace Access Panel 12b Hinge (2) 64-42546-03 64-42546-03 12c Hinge (2) 64-42546-04 64-42546-04
13 Gas Pipe Support Plate AS-90774-03 AS-90774-03 14 Blower Access Panel AS-90622-03 AS-90622-03 15 Right - Front Panel AS-90620-10 AS-90620-10 16 Heat Exchanger Mounting Frame AS-90754-03 AS-90754-03 17 Louvered Panel - Large AE-90726-06 AE-90726-06 18 Louvered Panel - Small AE-90726-07 AE-90726-07 19 Front/ Rear Post- Middle AE-90732-03 AE-90732-03 20 Condenser Access Panel AE-90734-05 AE-90734-05 21 Front/ Rear Corner Post AE-90701-03 AE-90701-03
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS, MISCELLANEOUS PARTS - BASE RAILS, INSIDE CABINET
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS, MISCELLANEOUS PARTS - FRONT AND RIGHT SIDES
RKMB
A
180
RKMB
A
180
RKMB
A
240
RKMB
A
240
Page 6 of 33
25-November-2015
92-42800-RKMB
Page 7
No. Notes
REAR: 17 Louvered Panel - Large AE-90726-06 AE-90726-06 18 Louvered Panel - Small AE-90726-07 AE-90726-07 19 Front/ Rear Post- Middle AE-90732-03 AE-90732-03 21 Front/ Rear Corner Post AE-90701-03 AE-90701-03 22 Right Rear Panel AS-90618-04 AS-90618-04 23 Left Rear Panel AS-90618-03 AS-90618-03 24 Supply Cover AS-90628-03 AS-90628-03 25 Return Cover AS-90628-03 AS-90628-03
LEFT: 26 Upper Left Panel AS-90624-06 AS-90624-06 27 Lower Left Panel AS-90624-04 AS-90624-04 28 Left Corner Panel AS-90755-03 AS-90755-03
Bracket (2) AE-90779-01 AE-90779-01
Gasket forreceptacle plate 68-42514-08 68-42514-08
Gasket fordisconnect plate 68-42514-09 68-42514-09 29 Plate - Install inside Panel -Receptacle AE-90756-02 AE-90756-02 30 Plate - Install inside Panel -Disconnect AE-90756-03 AE-90756-03
TOP: 31 Outdoor Top Front Panel AE-90633-06 AE-90633-06 32 Outdoor Top Rear Panel AE-90633-05 AE-90633-05 33 Outdoor Top Support AE-90704-04 AE-90704-04 34 Top Panel AS-90616-03 AS-90616-03 35 Venturi (4) AE-90632-01 AE-90632-01 36 Wire Grille (4) 95-42507-01 95-42507-01
MODEL TECHNICALVARIATIONS COOLING CAPACITY
PANELS -TOP, REAR AND LEFT SIDES
RKMB
A
180
RKMB
A
240
Page 7 of 33
25-November-2015
92-42800-RKMB
Page 8
MODEL
No. Notes
CONTROL BOX COMPONENTS:
6 Stk Control Box Mounting Panel AE-90712-02 AE-90712-02 AE-90712-02 56 Integrated Furnace Control (IFC) See Gas Controls 57 Stk Transformer (Before F2301) 46-42515-01 46-42515-01 46-42515-01 57 Stk Transformer (After F2301) 46-42515-01 46-42515-02 46-42515-01 58 Double Row Terminal Block 45-42548-02 45-42548-02 45-42548-02 59 Stk BlowerContactor 42-25103-02 42-25103-02 42-25103-02 60 Run Capacitor See FanGroup
Note: LowVoltageTerminal Block - 7 terminal block pieces are used in this application. The replacement45-40361-66 is a kit that includes 13 terminal block pieces and 1end piece. Order the amount of kits based on the replacement needed.
61 Low Voltage Terminal Block 45-40361-66 45-40361-66 45-40361-66 62 Stk Compressor Contactor(2) 42-25103-01 42-25103-01 42-25103-01 63 Stk Step DownTransformer (2) (Before F2301) N/A 46-23585-01 46-23585-01 63 Stk Step DownTransformer (2) (After F2301) N/A N/A 46-23585-01
Induced Draft Relay(2) (After F2301) N/A 42-19736-04 N/A
No. Notes
56 Integrated Furnace Control Board - Label IFC See Gas Controls
62a Stk Compressor Contactor -Label CC 1 42-42139-08 42-42139-08 42-42139-08 62b Stk Compressor Contactor -Label CC 2 42-42139-08 42-42139-08 42-42139-08 62c Stk Compressor Contactor - Label CC3 42-42139-08 42-42139-08 42-42139-08 62d Stk Compressor Contactor -Label CC 4 42-42139-08 42-42139-08 42-42139-08 60a Run Capacitor - Label RC 1 See FanGroup 60b Run Capacitor - Label RC 2 See FanGroup 60c Run Capacitor - Label RC 3 See Fan Group 60d Run Capacitor - Label RC 4 See FanGroup
38 Terminal Block- Label TB 1 45-21134-04 45-21134-04 45-21134-04
Note: LowVoltageTerminal Block - 7 terminal block pieces are used in this application. The replacement45-40361-66 is a kit that includes 13 terminal block pieces and 1end piece. Order the amount of kits based on the replacement needed.
61 Low Voltage Terminal Block - LabelTB 2 45-40361-66 45-40361-66 45-40361-66
58a Double RowTerminal Block- Label TB 4 45-42548-02 45-42548-02 45-42548-02 58b Double RowTerminal Block- Label TB 5 45-42548-02 45-42548-02 45-42548-02
Note:The following date code changes are related to the change in the Induced Draft Blower Motor
57 Stk Transformer - Label CT 46-42515-04 46-42515-04 46-42515-04
63a Transformer - Label PT 1 N/A 46-23585-01 46-23585-01 63b Transformer - Label PT 2 N/A 46-23585-01 46-23585-01 63c Transformer - Label PT3 N/A 46-23585-01 46-23585-01 63d Transformer - Label PT 4 N/A 46-23585-01 46-23585-01
59 Stk BlowerContactor - Label BC 42-25103-02 42-22641-03 42-25103-02
57 Stk Transformer - label CT 46-42515-04 46-42515-05 46-42515-04
63a Transformer - Label PT 1 N/A N/A 46-23585-01 63b Transformer - Label PT 2 N/A N/A 46-23585-01 63c Transformer - Label PT3 N/A N/A 46-23585-01 63d Transformer - Label PT 4 N/A N/A 46-23585-01
Induced Draft Relay- Label IDR 1 N/A 42-19736-04 N/A Induced Draft Relay- Label IDR 2 N/A 42-19736-04 N/A Terminal Block -Label TB 3 N/A 45-42548-02 N/A
59 Stk BlowerContactor - Label BC 42-25103-02 42-25103-01 42-25103-02
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
Unit date code on or before F1901
Unit date code after F1901
RKMB
A
090-150
C/P
RKMB
A
180/240
C
RKMB
A
090-150
D/N
RKMB
A
180/240
D
RKMB
A
090-150
Y
RKMB
A
180/240
Y
Page 8 of 33
25-November-2015
92-42800-RKMB
Page 9
MODEL
No. Notes
Wiring Harness - 12 Pinfrom IFC (15E) 45-42522-23 45-42522-23 45-42522-23 45-42522-23 Wiring Harness - 12 Pinfrom IFC (22E, 25E) 45-42522-11 45-42522-11 45-42522-11 45-42522-11 Wiring Harness - Outdoor Fan 1 45-42522-12 45-42522-12 45-42522-12 45-42522-26 Wiring Harness - Outdoor Fan 2 45-42522-14 45-42522-14 45-42522-14 45-42522-28 Wiring Harness - DraftInducer 45-42522-19 45-42522-19 45-42522-19 45-42522-30 Wiring Harness - Economizer 45-42522-20 45-42522-20 45-42522-20 45-42522-20 Bypass Plug - Economizer (12 Pin) AS-61997-55 AS-61997-55 AS-61997-55 AS-61997-55 Wiring Harness - Compressor 1 45-42522-21 45-42522-21 45-42522-03 Call for availability Wiring Harness - Compressor 2 45-42522-22 45-42522-22 45-42522-15 Call for availability
No. Notes
Wiring Harness - 12 Pinfrom IFC (15E) 45-42522-23 45-42522-23 45-42522-23 45-42522-23 Wiring Harness - 12 Pinfrom IFC (22E, 25E) 45-42522-11 45-42522-11 45-42522-11 45-42522-11 Wiring Harness - Outdoor Fan 1 45-42522-12 45-42522-12 45-42522-12 45-42522-26 Wiring Harness - Outdoor Fan 2 45-42522-14 45-42522-14 45-42522-14 45-42522-28 Wiring Harness - DraftInducer 45-42522-19 45-42522-19 45-42522-19 45-42522-30 Wiring Harness - Economizer 45-42522-20 45-42522-20 45-42522-20 45-42522-20 Bypass Plug - Economizer (12 Pin) AS-61997-55 AS-61997-55 AS-61997-55 AS-61997-55 Wiring Harness - Compressor 1 45-42522-21 45-42522-21 45-42522-21 Call for availability Wiring Harness - Compressor 2 45-42522-22 45-42522-22 45-42522-22 Call for availability
No. Notes
Wiring Harness - 12 Pinfrom IFC (15E) 45-42522-23 45-42522-23 45-42522-23 45-42522-23 Wiring Harness - 12 Pinfrom IFC (22E, 25E) 45-42522-11 45-42522-11 45-42522-11 45-42522-11 Wiring Harness - Outdoor Fan 1 45-42522-12 45-42522-12 45-42522-12 45-42522-26 Wiring Harness - Outdoor Fan 2 45-42522-14 45-42522-14 45-42522-14 45-42522-28 Wiring Harness - DraftInducer 45-42522-19 45-42522-19 45-42522-19 45-42522-30 Wiring Harness - Economizer 45-42522-20 45-42522-20 45-42522-20 45-42522-20 Bypass Plug - Economizer (12 Pin) AS-61997-55 AS-61997-55 AS-61997-55 AS-61997-55 Wiring Harness - Compressor 1 45-42522-21 45-42522-21 45-42522-21 Call for availability Wiring Harness - Compressor 2 45-42522-22 45-42522-22 45-42522-22 Call for availability
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
RKMB
A 090 C/P
RKMB
A 090 D/N
RKMB
A 090
Y
RKMB
A 102 C/P
RKMB
A 102 D/N
RKMB
A 102
Y
RKMB
A 120 C/P
RKMB
A 120 D/N
RKMB
A 120
Y
RKMB
A 150 C/P
RKMB
A 150 D/N
RKMB
A 150
Y
Page 9 of 33
25-November-2015
92-42800-RKMB
Page 10
MODEL
No. Notes
4 Wiring Harness - 12Pin from IFC (See Note 4) 45-42522-44 45-42522-44 45-42522-44 Wiring Harness - Outdoor Fan1 45-42522-33 45-42522-33 45-42522-33 Wiring Harness - Outdoor Fan2 45-42522-34 45-42522-34 45-42522-34 Wiring Harness - Outdoor Fan3 45-42522-35 45-42522-35 45-42522-35 Wiring Harness - Outdoor Fan4 45-42522-36 45-42522-36 45-42522-36 Wiring Harness - Draft Inducer (30E, 35E) 45-42522-38 45-42522-38 45-42522-38 Bypass Plug - Economizer(12 Pin) AS-61997-55 AS-61997-55 AS-61997-55
No. Notes
4 Wiring Harness - 12Pin from IFC (See Note 4) 45-42522-44 45-42522-44 45-42522-44 Wiring Harness - Outdoor Fan1 45-42522-33 45-42522-33 45-42522-33 Wiring Harness - Outdoor Fan2 45-42522-34 45-42522-34 45-42522-34 Wiring Harness - Outdoor Fan3 45-42522-35 45-42522-35 45-42522-35 Wiring Harness - Outdoor Fan4 45-42522-36 45-42522-36 45-42522-36 Wiring Harness - Draft Inducer (30E) 45-42522-38 45-42522-38 45-42522-38 Bypass Plug - Economizer(12 Pin) AS-61997-55 AS-61997-55 AS-61997-55
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
ELECTRIC GROUP
RKMB
A
180
C
RKMB
A
240
C
RKMB
A
180
D
RKMB
A
240
D
RKMB
A
180
Y
RKMB
A
240
Y
Page 10 of 33
25-November-2015
92-42800-RKMB
Page 11
MODEL
No. Notes
52 Stk Motor (2) 51-42534-01 51-42534-02 51-42534-03 53 Stk Fan Blade (2) 70-42502-01 70-42502-01 70-42502-01 54 Stk Motor Fan Cap(2) 56-17070-01 56-17070-01 56-17070-01 55 Stk Motor Mount - Outdoor Fan (2) 70-42504-01 70-42504-01 70-42504-01
60a,b Stk Run Capacitor (2) 43-25134-04 43-25134-04 43-25134-04
No. Notes
52 Stk Motor (2) 51-42534-01 51-42534-02 51-42534-03 53 Stk Fan Blade (2) 70-42502-01 70-42502-01 70-42502-01 54 Stk Motor Fan Cap(2) 56-17070-01 56-17070-01 56-17070-01 55 Motor Mount - Outdoor Fan (2) 70-42504-01 70-42504-01 70-42504-01
60a,b Stk Run Capacitor (2) 43-25134-04 43-25134-04 43-25134-04
No. Notes
52 Stk Fan Motor (4) 51-42534-01 51-42534-02 51-42534-03 53 Stk Fan Blade (4) 70-42502-01 70-42502-01 70-42502-01 54 Stk Plastic Cap for Fan Motor (4) 56-17070-01 56-17070-01 56-17070-01 55 Stk Motor Mount - Outdoor Fan (4) 70-42504-01 70-42504-01 70-42504-01 60 Stk Capacitor - FanMotor (4) 43-25134-04 43-25134-04 43-25134-04
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
FANGROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
FANGROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
FANGROUP
RKMB
A
090/102
C/P
RKMB
A
120/150
C/P
RKMB
A
180/240
C/P
RKMB
A
090/102
D/N
RKMB
A
120/150
D/N
RKMB
A
180/240
D/N
RKMB
A
090/102
Y
RKMB
A
120/150
Y
RKMB
A
180/240
Y
Page 11 of 33
25-November-2015
92-42800-RKMB
Page 12
No. Notes
CONDENSER COIL: 37a Stk Condenser Coil - Outdoor AS-90656-21 AS-90656-20 AS-90656-25 AS-90656-42 37b Stk Condenser Coil - Outdoor N/A N/A AS-90656-25 AS-90656-42
38 Front Air Stop N/A N/A AE-90706-03 AE-90706-03 39 Rear Air Stop N/A N/A AE-90706-04 AE-90706-04
40 Bottom Retainer (2) N/A N/A AE-90700-02 AE-90700-02 41a Top Support Condenser Coil N/A N/A AE-90612-02 AE-90612-02 41b Top Support Condenser Bulkhead N/A N/A AE-90612-03 AE-90612-03
EVAPORATOR COIL:
42 Stk Complete Coil -Indoor AS-90656-29 AS-90656-41 AS-90656-32 AS-90656-43 42a Stk Distributor/Cap Tube - CKT 1 83-100632-01 83-100632-03 83-100632-18 N/A 42b Stk Distributor/Cap Tube - CKT 2 83-100632-01 83-100632-03 83-100632-18 N/A 42c Stk FlowcheckDistributor/Piston Assy (2) N/A N/A N/A 61-26112-09
43 Stk Drain Pan 68-42500-01 68-42500-01 68-42500-01 68-42500-01
FILTER PIECES:
44a,b Filter Frame (2) AE-90606-02 AE-90606-02 AE-90606-02 AE-90606-02
45 Air Stop Bottom AE-90605-03 AE-90605-03 AE-90605-03 AE-90605-03
46 Stop Air Stop AE-90605-07 AE-90605-07 AE-90605-07 AE-90605-07
47 Top Air Stop AS-90604-02 AS-90604-02 AS-90604-02 AS-90604-02
48a,b Filter Channel (2) AS-90607-02 AS-90607-02 AS-90607-02 AS-90607-02
49 Filter Channel (2) AE-90608-02 AE-90608-02 AE-90608-02 AE-90608-02
50 Filter (6) 54-42541-01 54-42541-01 54-42541-01 54-42541-01
51 Filter Slide (2) AE-90615-01 AE-90615-01 AE-90615-01 AE-90615-01
MODEL TECHNICALVARIATIONS COOLING CAPACITY
COIL GROUP
RKMB
A
090
RKMB
A
102
RKMB
A
120
RKMB
A
150
Page 12 of 33
25-November-2015
92-42800-RKMB
Page 13
No. Notes
40 Air Flow Panel AE-90828-01 AE-90828-01 41 Drain Pan MountingAngle AE-90799-01 AE-90799-01
EVAPORATOR COIL:
42 Stk Complete Coil - Indoor AS-90656-39 AS-90656-31 42a Distributor/Cap Tube - CKT 1, CKT2 83-100632-11 83-100632-21 42b Distributor/Cap Tube - CKT 3, CKT4 83-100632-12 83-100632-22
43 Stk Drain Pan 68-42500-01 68-42500-01
CONDENSER COIL: 37a Stk Condenser Coil - Front AS-90656-35 AS-90656-33 37b Stk Condenser Coil - Rear AS-90656-36 AS-90656-34
FILTER PIECES:
39 Filter Frame Assembly AS-90603-03 AS-90603-03 44a Filter Frame AE-90606-03 AE-90606-03 44b Filter Frame AE-90606-04 AE-90606-04
46 Air Stop - Side AE-90605-08 AE-90605-08
49 Filter Channel AS-90607-02 AS-90607-02
45 Air Stop Bottom AE-90605-03 AE-90605-03
47 Top Air Stop AS-90604-03 AS-90604-03
48a,b Filter Channel (2) AE-90608-02 AE-90608-02
50 Filter - 18"x18"x2" (2) 54-42541-01 54-42541-01
50 Filter - 18"x24"x2" (2) 54-42541-03 54-42541-03
51 Filter Slide (2) AE-90615-01 AE-90615-01
MODEL TECHNICALVARIATION COOLING CAPACITY
COIL GROUP
RKMB
A
180
RKMB
A
240
Page 13 of 33
25-November-2015
92-42800-RKMB
Page 14
MODEL
No. Notes
Stk Blower Assembly (Less Motor, Belt and Pulley) AS-90757-01 AS-90757-01 AS-90757-01 AS-90757-01 64 Scroll Side Can not beordered individually 64 Scroll Side Can not beordered individually 64 Scroll Wrap Can not be ordered individually 65 Stk BlowerWheel 70-42540-02 70-42540-02 70-42540-02 70-42540-02 66 Bearing Frame Tri-Arm (2) 70-42540-05 70-42540-05 70-42540-05 70-42540-05 67 Stk Bearing with Bearing Lock (2) 70-42540-06 70-42540-06 70-42540-06 70-42540-06 68 Stk BlowerShaft 70-42540-04 70-42540-04 70-42540-04 70-42540-04 69 Blower Mounting Angles (2) AE-90708-01 AE-90708-01 AE-90708-01 AE-90708-01 70 Motor Mount AE-90710-02 AE-90710-02 AE-90710-02 AE-90710-02
No. Notes
71 Stk BlowerMotor 51-42536-01 51-42536-01 51-42536-01 51-42537-01 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-42538-02 73 Stk Belt 71-40438-27 71-40438-27 71-40438-27 71-40438-23 74 Stk FixedSheave includes Bushing 71-26254-82 71-26254-82 71-26254-82 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
No. Notes
71 Stk BlowerMotor 51-42537-01 51-42537-01 51-42537-01 51-42498-07 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-40427-31 73 Stk Belt 71-40438-27 71-40438-27 71-40438-27 71-40438-23 74 Stk FixedSheave includes Bushing 71-26254-82 71-26254-82 71-26254-82 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
No. Notes
71 Stk BlowerMotor 51-42536-02 51-42536-02 51-42536-02 51-42536-02 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-42538-02 73 Stk Belt 71-40438-27 71-40438-27 71-40438-27 71-40438-23 74 Stk FixedSheave includes Bushing 71-26254-82 71-26254-82 71-26254-82 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
TECHNICALVARIATION COOLING CAPACITY DRIVE PACKAGE
BLOWER ASSEMBLY GROUP - BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
RKMB
A
090
L
RKMB
A 090 C/D
L
RKMB
A 090 N/P
L
RKMB
A 090
Y
L
RKMB
A
102
L
RKMB
A 102 C/D
L
RKMB
A 102 N/P
L
RKMB
A 102
Y
L
RKMB
A
120
L
RKMB
A 120 C/D
L
RKMB
A 120 N/P
L
RKMB
A 120
Y
L
RKMB
A
150
L
RKMB
A 150 C/D
L
RKMB
A 150 N/P
L
RKMB
A 150
Y
L
Page 14 of 33
25-November-2015
92-42800-RKMB
Page 15
MODEL
No. Notes
Stk Blower Assembly (Less Motor, Belt and Pulley) AS-90757-01 AS-90757-01 AS-90757-01 AS-90757-01 64 Scroll Side Can not beordered individually 64 Scroll Side Can not beordered individually 64 Scroll Wrap Can not be ordered individually 65 Stk BlowerWheel 70-42540-02 70-42540-02 70-42540-02 70-42540-02 66 Bearing Frame Tri-Arm (2) 70-42540-05 70-42540-05 70-42540-05 70-42540-05 67 Stk Bearing with Bearing Lock (2) 70-42540-06 70-42540-06 70-42540-06 70-42540-06 68 Stk BlowerShaft 70-42540-04 70-42540-04 70-42540-04 70-42540-04 69 Blower Mounting Angles (2) AE-90708-01 AE-90708-01 AE-90708-01 AE-90708-01 70 Motor Mount AE-90710-02 AE-90710-02 AE-90710-02 AE-90710-02
No. Notes
71 Stk BlowerMotor 51-42537-01 51-42537-01 51-42537-01 51-42498-07 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-42538-03 73 Stk Belt 71-40438-23 71-40438-23 71-40438-23 71-40438-25 74 Stk FixedSheave w/Bushing 71-26254-84 71-26254-84 71-26254-84 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
No. Notes
71 Stk BlowerMotor 51-42537-01 51-42537-01 51-42537-01 51-42498-07 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-42538-03 73 Stk Belt 71-40438-23 71-40438-23 71-40438-23 71-40438-25 74 Stk FixedSheave w/Bushing 71-26254-84 71-26254-84 71-26254-84 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
No. Notes
71 Stk BlowerMotor 51-42537-02 51-42537-02 51-42537-02 51-42574-01 72 Stk Variable Sheave 71-42538-02 71-42538-02 71-42538-02 71-42538-03 73 Stk Belt 71-40438-23 71-40438-23 71-40438-23 71-40438-25 74 Stk FixedSheave w/Bushing 71-26254-84 71-26254-84 71-26254-84 71-26254-84
Stk Bushing 71-26253-01 71-26253-01 71-26253-01 71-26253-01
TECHNICALVARIATION COOLING CAPACITY DRIVE PACKAGE
BLOWER ASSEMBLY GROUP - BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
RKMB
A
090
M
RKMB
A 090 C/D
M
RKMB
A 090 N/P
M
RKMB
A 090
Y
M
RKMB
A
102
M
RKMB
A 102 C/D
M
RKMB
A 102 N/P
M
RKMB
A 102
Y
M
RKMB
A
120
M
RKMB
A 120 C/D
M
RKMB
A 120 N/P
M
RKMB
A 120
Y
M
RKMB
A
150
M
RKMB
A 150 C/D
M
RKMB
A 150 N/P
M
RKMB
A 150
Y
M
Page 15 of 33
25-November-2015
92-42800-RKMB
Page 16
MODEL
No. Notes
64 Stk BlowerAssembly (2) AS-90757-03 AS-90757-03
Scroll Side Can not be ordered individually Scroll Side Can not be ordered individually
Scroll Wrap Can not be ordered individually 65 Stk BlowerWheel 70-42564-02 70-42564-02 66 Stk Bearing FrameTri-Arm (2) 70-42284-04 70-42284-04 67 Stk Bearing with Bearing Lock (4) 70-42540-06 70-42540-06 68 Stk BlowerShaft 70-42564-03 70-42564-03 69 Blower Mounting Angles (4) AE-90708-02 AE-90708-02 70 Motor Mount AE-90710-03 AE-90710-03 94 Blower Connector (3) AE-90798-01 AE-90798-01
No. Notes
71 Stk BlowerMotor 51-42537-01 51-42537-02 51-42498-07 51-42574-01 72 Stk Variable Sheave 71-40427-27 71-40427-27 71-40427-31 71-40427-31 73 Stk Belt 71-40438-33 71-40438-33 71-40438-32 71-40438-32 74 Stk FixedSheave including Bushing 71-26254-82 71-26254-82 71-26254-81 71-26254-81
Stk Bushing for Sheave 71-26253-01 71-26253-01 71-26253-01 71-26253-01
No. Notes
71 Stk BlowerMotor 51-42498-07 51-42574-01 51-42498-09 51-42498-11 72 Stk Variable Sheave 71-42538-03 71-42538-03 71-42538-04 71-42538-04 73 Stk Belt 71-40438-37 71-40438-37 71-40438-38 71-40438-38 74 Stk FixedSheave w/Bushing 71-26254-83 71-26254-83 71-26254-81 71-26254-81
Stk Bushing for Sheave 71-26253-01 71-26253-01 71-26253-01 71-26253-01
TECHNICALVARIATION COOLING CAPACITY DRIVE PACKAGE
BLOWER ASSEMBLY GROUP - BELT DRIVE
The Assembly Does Not Include The Motor, Belt Or Pulley
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION DRIVE PACKAGE
MOTOR,BELT ANDVARIABLE PITCH SHEAVE FOR BLOWER ASSEMBLY BELT DRIVE
RKMB
A 180 L/M
RKMB
A 180 C/D
L
RKMB-
A 240 C/D
L
RKMB
A 240 L/M
RKMB
A 180
Y
L
RKMB
A 240
Y
L
RKMB
A 180 C/D
M
RKMB
A 240 C/D
M
RKMB
A
180
Y M
RKMB
A
240
Y M
Page 16 of 33
25-November-2015
92-42800-RKMB
Page 17
MODEL
No. Notes
Compressor ID: 6538 6657 6548 6722
75 Stk Compressor -Circuit One 55-23139-71S 55-23140-40S 55-23140-92S 55-23141-43S 75 Stk Compressor -Circuit Two 55-23139-71S 55-23140-40S 55-23139-30S 55-23141-73S
Stk Crankcase Heater 44-17402-45 44-17402-47 44-17402-47 44-17402-47
No. Notes
Compressor ID: 6539 6658 6549 6723
75 Stk Compressor -Circuit One 55-23139-72S 55-23140-41S 55-23140-93S 55-23141-44S 75 Stk Compressor -Circuit Two 55-23139-72S 55-23140-41S 55-23139-35S 55-23141-72S
Stk Crankcase Heater 44-17402-46 44-17402-48 44-17402-48 44-17402-11
No. Notes
Compressor ID: 6542 6659 6552 6724
75 Stk Compressor -Circuit One 55-23139-82S 55-23140-42S 55-23140-94 55-23141-45S 75 Stk Compressor -Circuit Two 55-23139-82S 55-23140-42S 55-23140-94 55-23141-88S
Stk Crankcase Heater N/A 44-17402-49 N/A 44-17402-12
No. Notes
Compressor ID: 6616 6621 6617 6622
75 Stk Compressor (4) 55-23139-71S 55-23139-30S 55-23139-72S 55-23139-31S
Stk Crankcase Heater 44-17402-45 44-17402-45 44-17402-48 44-17402-47
No. Notes
Compressor ID: 6618 6623
75 Stk Compressor (4) 55-23139-82S 55-23139-32S
Stk Crankcase Heater N/A N/A
TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
COMPRESSOR GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
COMPRESSOR GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
COMPRESSOR GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
COMPRESSOR GROUP
MODEL TECHNICALVARIATION COOLING CAPACITY ELECTRICAL DESIGNATION
COMPRESSOR GROUP
RKMB
A
090
C
RKMB
A
090
D
RKMB
A
090
Y
RKMB
A
180
C
RKMB
A
180
Y
RKMB
A
102
C
RKMB
A
102
D
RKMB
A
102
Y
RKMB
A
240
C
RKMB
A
240
Y
RKMB
A 120
C
RKMB
A 120
D
RKMB
A 120
Y
RKMB
A 180
D
RKMB
A
150
C
RKMB
A
150
D
RKMB
A
150
Y
RKMB
A
240
D
Page 17 of 33
25-November-2015
92-42800-RKMB
Page 18
MODEL
No. Notes
76 Stk Heat Exchanger AS-90645-01 AS-90645-03 AS-90645-03 77 Turbulators 78 Inducer Mounting Plate Gasket 68-42518-02 68-42518-02 68-42518-02
79 Inducer Mounting Plate AE-90675-03 AE-90675-02 AE-90675-04 80 Gasket - Induced Draft Blower
Note: Induced Draft Blower 70-23641-81 is 230 V, and 70-23641-82 is 460V.Verify original part before replacing.
81 Stk Induced DraftBlower w/Gasket - Voltages C/P/Y
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - Before F2301
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - After F2301
82 Stk Flue Duct
Gasket - Flue Duct
83 Stk Pressure Switch(2) 42-23649-02 42-23649-02 42-23649-02 84 Pressure Switch Mounting Bracket (2) -Before F1909 AE-90635-03 AE-90635-03 AE-90635-03 84 Pressure Switch Mounting Bracket (2) -After F1909 AE-90635-05 AE-90635-05 AE-90635-05 85 Stk Inside CabinetPanel/Pieces 47-25349-09 47-25349-02 47-25349-04 86 Stk Spark Ignitor 62-23556-08 62-23556-08 62-23556-08 87 Stk Flame Sensor 62-23543-02 62-23543-02 62-23543-02 88 Stk Overtemperature Limits(2) 47-22861-01 47-22861-01 47-22861-01 89 Burner Support AE-90643-01 AE-90643-01 AE-90643-01 90 Burner Support Brackets(2) AE-90642-02 AE-90642-02 AE-90642-02 91 Stk Burner Assembly AS-90772-01 AS-90772-02 AS-90772-02 92 Heat Shield AE-90644-02 AE-90644-02 AE-90644-02 93 Stk Manifold(w/o Orifices) 81-42509-03 81-42509-02 81-42509-02
94 Stk Square HeadPlug (Used to plug unused holes on Manifold) 95 Burner Orifices - Natural Gas See Orifice Selection Chart
95 Burner Orifices - LP See Orifice Selection Chart
Number of Orifices (6) (9) (9)
TECHNICALVARIATION COOLING CAPACITY HEATING CAPACITY
HEAT EXCHANGER, BURNER/MANIFOLD
RKMB
A
090-150
15
AE-58922-01
(6)
68-23643-02
(2)
70-23641-81
(2)
70-23641-81
(2)
70-23641-82
(2)
75-23678-01
(2)
68-23680-04
(4)
81-23593-01
(4)
RKMB
A
090-150
22
AE-58922-01
(9)
68-23643-02
(2)
70-23641-81
(2)
70-23641-81
(2)
70-23641-82
(2)
75-23678-01
(2)
68-23680-04
(4)
81-23593-01
(1)
RKMB
A
090-150
25
AE-58922-01
(9)
68-23643-02
(2)
70-23641-81
(2)
70-23641-81
(2)
70-23641-82
(2)
75-23678-01
(2)
68-23680-04
(4)
81-23593-01
(1)
Page 18 of 33
25-November-2015
92-42800-RKMB
Page 19
MODEL
No. Notes
12a Gas Furnace Access Panel AS-90715-04 AS-90715-05
76 Stk Heat Exchanger AS-90645-06 AS-90645-04 77 Turbulators 78 Inducer Mounting Plate Gasket 68-42518-03 68-42518-03
79 Inducer Mounting Plate AE-90675-08 AE-90675-06 80 Stk Gasket- Induced Draft Blower
Note: Induced Draft Blower 70-23641-81 is 230 V, and 70-23641-82 is 460V.Verify original part before replacing.
81 Stk Induced DraftBlower w/Gasket - Voltages C/P/Y
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - Before F1901
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - After F1901
Transformer See Electric Group
82 Flue Duct
Gasket - Flue Duct
83a Stk Pressure Switch -Left NA 42-23649-03 83b Stk Pressure Switch -Middle Left 42-23649-03 42-23649-02 83c Stk Pressure Switch - Middle Right 42-23649-02 42-23649-03 83d Stk Pressure Switch -Right NA NA
84a Pressure Switch Mounting Bracket - (Single Mount) -Before F1909
84a Pressure Switch Mounting Bracket - (Single Mount) -After F1909 84b Pressure Switch Mounting Bracket (Dual Mount) AE-90635-04 AE-90635-04
Stk Limit Control 47-25349-10 47-25349-03
Burner Assembly: 87 Stk Spark Ignitor 62-23556-09 62-23556-09 85 Stk Flame Sensor 62-23543-02 62-23543-02 88 Stk Overtemperature Limits(4) 47-22861-01 47-22861-01 89 Burner Support AS-90830-01 AS-90830-01 90 Burner Support Brackets(2) AE-90642-02 AE-90642-02 91 Stk Burner Assembly AS-90772-05 AS-90772-03 92 Heat Shield AE-90644-03 AE-90644-03 93 Stk Manifold(w/o Orifices) 81-42509-07 81-42509-04
Square Head Plug (Used toplug unused holes on Manifold) 95 Burner Orifices - Natural Gas See Orifice Selection Chart
95 Burner Orifices - LP See Orifice Selection Chart
Number of Orifices (10) (14)
TECHNICALVARIATION COOLING CAPACITY HEATING CAPACITY
HEAT EXCHANGER, BURNER/ MANIFOLD
RKMB
A
180
25
AE-58922-02
(10)
68-23643-02
(2)
70-23641-81
(2)
70-23641-81
(2)
70-23641-82
(2)
75-23678-01
(3)
68-23680-04
(6)
AE-90635-03
(1)
AE-90635-05
(1)
81-23593-01
(3)
RKMB
A
180
35
AE-58922-02
(14)
68-23643-02
(3)
70-23641-81
(3)
70-23641-81
(3)
70-23641-82
(3)
75-23678-01
(3)
68-23680-04
(6)
AE-90635-03
(2)
AE-90635-05
(2)
81-23593-01
(1)
Page 19 of 33
25-November-2015
92-42800-RKMB
Page 20
MODEL
No. Notes
12a Gas Furnace Access Panel AS-90715-05 AS-90715-03
76 Stk Heat Exchanger AS-90645-05 AS-90645-04 77 Turbulators 78 Inducer Mounting Plate Gasket 68-42518-03 68-42518-03
79 Inducer Mounting Plate AE-90675-07 AE-90675-05 80 Gasket - Induced Draft Blower
Note: Induced Draft Blower 70-23641-81 is 230 V, and 70-23641-82 is 460V.Verify original part before replacing.
81 Stk Induced DraftBlower w/Gasket - Voltages C/P/Y
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - Before F1901
81 Stk Induced DraftBlower w/Gasket - Voltages D/N - After F1901
Transformer See Electric Group 82 Flue Duct
Gasket - Flue Duct
83a Stk Pressure Switch -Left 42-23649-03 42-23649-03 83b Stk Pressure Switch -Middle Left 42-23649-01 42-23649-02 83c Stk Pressure Switch - Middle Right 42-23649-03 42-23649-03 83d Stk Pressure Switch -Right N/A 42-23649-02
84a Pressure Switch Mounting Bracket - (Single Mount) -Before F1909
84a Pressure Switch Mounting Bracket - (Single Mount) -After F1909 84b Pressure Switch Mounting Bracket (Dual Mount) AE-90635-04 AE-90635-04
Stk Limit Control 47-25349-09 47-25349-03
Burner Assembly: 87 Stk Spark Ignitor 62-23556-09 62-23556-09 85 Stk Flame Sensor 62-23543-02 62-23543-02 88 Stk Overtemperature Limits(4) 47-22861-01 47-22861-01 89 Burner Support AS-90830-01 AS-90830-01 90 Burner Support Brackets(2) AE-90642-02 AE-90642-02 91 Stk Burner Assembly AS-90772-06 AS-90772-03 92 Stk Heat Shield AE-90644-03 AE-90644-03 93 Stk Manifold(w/o Orifices) 81-42509-07 81-42509-04
Square Head Plug (Used toplug unused holes on Manifold) 81-23593-01 81-23593-01 95 Burner Orifices - Natural Gas See Orifice Selection Chart 95 Burner Orifices - LP See Orifice Selection Chart
Number of Orifices (12) (14)
TECHNICALVARIATION COOLING CAPACITY HEATING CAPACITY
HEAT EXCHANGER, BURNER/MANIFOLD
RKMB
A
240
30
AE-58922-02
(12)
68-23643-02
(3)
70-23641-81
(3)
70-23641-81
(3)
70-23641-82
(3)
75-23678-01
(3)
68-23680-04
(6)
AE-90635-03
(2)
AE-90635-05
(2)
RKMB
A
240
40
AE-58922-02
(14)
68-23643-02
(4)
70-23641-81
(4)
70-23641-81
(4)
70-23641-82
(4)
75-23678-01
(4)
68-23680-04
(8)
AE-90635-03
(2)
AE-90635-05
(2)
Page 20 of 33
25-November-2015
92-42800-RKMB
Page 21
No. Notes
Louver Panel- Option RXRX-AAD01C
Time Delay Relay - Option RXMD-A04
High Pressure / LowPressure Control Factory Installed Option RXRX-AK01
Freeze Stat- Option RXRX-AM01
Convenience Outlet -Option RXRX-AN01
Disconnect Switch Kit - Option RXRX-AP01
Low Ambient Control -Option RXRZ-A90
No. Notes
Time Delay Relay RXMD-A05
Freeze Stat RXRX-AM01
Convenience Outlet RXRX-AN01
Disconnect Switch Kit RXRX-AP01
Low Ambient Control RXRZ-A90
Carbon Dioxide Sensor RXRX-AR01
Motorized Fresh Air RXRX-AT01
Manual FreshAir RXRF-GEA1
No. Notes
Outdoor Air Sensor Field Install RXRD-EDCM2
Single Enthalpy Field RXRD-EDCM3
Dual Enthalpy RXRD-EDCM4
No. Notes
Outdoor Air Sensor RXRD-EFCM2
Single Enthalpy RXRD-EFCM3
Dual Enthalpy RXRD-EFCM4
No. Notes
PowerExhaust - C Voltage RXRX-BFF02C
PowerExhaust - D Voltage RXRX-BFF02D
PowerExhaust - YVoltage RXRX-BFF02Y
MODEL TECHNICALVARIATION COOLING CAPACITY
FACTORY INSTALLED OPTIONS / FIELD INSTALL ACCESSORIES
MODEL TECHNICALVARIATION COOLING CAPACITY
FACTORY INSTALLED OPTIONS / FIELD INSTALL ACCESSORIES
MODEL TECHNICALVARIATION
ECONOMIZERS
MODEL COOLING CAPACITY
ECONOMIZERS
MODEL TECHNICALVARIATION COOLING CAPACITY
OPTIONS AND ACCESSORIES KITS
RKMB
A
090-150, 181
RKMB
A
180/240
RKMB
090-150, 181
RKMB
180/240
RKMB
A
090-240
Page 21 of 33
25-November-2015
92-42800-RKMB
Page 22
No. Notes
56 Stk IntegratedFurnace Control 62-42506-01 See Note 1 62-42506-01 62-42506-01 62-42506-02 96 Stk GasValve - Natural Gas (Before F0308) 60-42508-01 See Note 1 60-23490-09 60-42570-01 60-23490-13 96 Stk GasValve - Natural Gas (After F0308) 60-42508-01 See Note 1 60-23490-09 60-101778-01 60-23490-13 96 Stk,2 Gas Valve - LP See Note 2 See Note 1 See Note 2 See Note 3 See Note 2 97 Stk Street Elbow 81-17486-02 See Note 1 81-17486-01 81-40271-05 81-40271-04 98 Nipple - Black N/A See Note 1 N/A 81-40383-04 N/A 99 90 Deg Elbow Std N/A See Note 1 N/A 81-40394-24 N/A
Stk LP Conversion Kit EP-87W See Note 1 EP-86W FP-14 EP-86W
No. Notes
56 Stk IntegratedFurnace Control 62-42506-02 96 Stk GasValve - Natural Gas 60-102405-01 96 Stk,2 Gas Valve - LP See Note 2 97 Stk Street Elbow 81-40271-04
Stk LP Conversion Kit FP-24
MODEL TECHNICALVARIATION GAS CODE
MODEL TECHNICALVARIATION GAS CODE
RKMB
A
1Z
GAS CONTROLS
RKMB
A
2K
GAS CONTROLS
RKMB
A
2A
RKMB
A
2B
RKMB
A
2D
RKMB
A
2F
Page 22 of 33
25-November-2015
92-42800-RKMB
Page 23
CAUTION: Selection of the correct Natural Gas Orifice requires the following information forthe specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas andPropane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kitspecified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on a Natural Gas heatingvalue of 1075 BTU/cu. ft and a pressuresetting of 3.5 in. water column. NOTE: Factory installed orifices are calculatedand sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 2000ft.
Furnace
Input
Rating (BTU/HR)
40,000 36,000 2 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 60,000 54,000 3 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 72,000 N/A 4 62-22175-15 62-22175-49 62-22175-50 62-22175-51 62-22175-15 N/A 80,000 72,000 4 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15
90,000 N/A 5 62-22175-15 62-22175-49 62-22175-50 62-22175-51 62-22175-15 N/A 100,000 90,000 5 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 120,000 108,000 6 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 62-22175-15 135,000 121,500 6 62-22175-44 62-22175-45 62-22175-47 62-22175-48 62-22175-44 62-22175-45 150,000 135,000 6 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 180,000 N/A 9 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 210,000 N/A 9 62-22175-43 62-22175-44 62-22175-45 62-22175-47 62-22175-43 N/A 210,000 N/A 10 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 225,000 202,500 9 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 250,000 225,000 10 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 252,000 225,000 9 62-22175-40 62-22175-42 62-22175-43 62-22175-44 62-22175-40 62-22175-42 252,000 N/A 12 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 290,000 N/A 14 62-22175-45 62-22175-47 62-22175-48 62-22175-49 62-22175-45 N/A 300,000 270,000 12 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 330,000 N/A 14 62-22175-43 62-22175-44 62-22175-45 62-22175-47 62-22175-43 N/A 350,000 315,000 14 62-22175-42 62-22175-43 62-22175-44 62-22175-45 62-22175-42 62-22175-44 400,000 360,000 14 62-22175-40 62-22175-42 62-22175-43 62-22175-44 62-22175-40 62-22175-42
CAUTION: Selection of the correct LP Orifice requires the following information for the specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.) For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas andPropane Installation Code, CAN B149.1. CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done usingthe kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is developed using the specifiedpressure setting of 10 in. water column insteadof the 11.0 in water column used bythe NFG and CANB149.1. NOTE: Orifices supplied inthe LP Conversion Kit are calculated andsized based on a heating value of2500 BTU/cu. ft. and an elevation of0 - 2000 ft.
Furnace
Input
Rating (BTU/HR)
40,000 36,000 2 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
60,000 54,000 3 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
72,000 N/A 4 62-22175-13 62-22175-57 62-22175-57 62-22175-59 62-22175-13 N/A
80,000 72,000 4 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13
90,000 N/A 5 62-22175-13 62-22175-57 62-22175-57 62-22175-59 62-22175-13 N/A 100,000 90,000 5 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13 120,000 108,000 6 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 62-22175-13 135,000 121,500 6 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-55 150,000 135,000 6 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 180,000 N/A 9 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 210,000 N/A 9 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 N/A 210,000 N/A 10 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 225,000 202,500 9 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 250,000 225,000 10 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 252,000 225,000 9 62-22175-53 62-22175-54 62-22175-54 62-22175-55 62-22175-53 62-22175-54 252,000 N/A 12 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 290,000 N/A 14 62-22175-55 62-22175-55 62-22175-56 62-22175-56 62-22175-55 N/A 300,000 270,000 12 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 330,000 N/A 14 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 N/A 350,000 315,000 14 62-22175-54 62-22175-55 62-22175-55 62-22175-56 62-22175-54 62-22175-54 400,000 360,000 14 62-22175-53 62-22175-54 62-22175-54 62-22175-55 62-22175-53 62-22175-54
Canadian High
Altitude Derated
Input
(BTU/HR)
Canadian High
Altitude Derated
Input
(BTU/HR)
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - NATURALGAS
Number
of
Burners
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - LP
Number
of
Burners
0 - 2000
U.S.
0 - 2000
U.S.
2001 - 4000
U.S.
2001 - 4000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Country
8000+
U.S.
Country
8000+
U.S.
0 - 2000
Canada
0 - 2000
Canada
2001 - 4500
Canada
2001 - 4500
Canada
25-November-2015
92-42800-RKMB
Page 23 of 33
Page 24
Exploded View 090-150
Page 24 of 33
25-November-2015
92-42800-RKMB
Page 25
Exploded View 180 240
Page 25 of 33
25-November-2015
92-42800-RKMB
Page 26
Filter Rack Assembly 090-150
Coil Assembly 090-150
Page 26 of 33
25-November-2015
92-42800-RKMB
Page 27
Control Board Assembly 090-150
Blower Assembly 090-150
Page 27 of 33
25-November-2015
92-42800-RKMB
Page 28
Heat Exchanger Assembly 090-150
Page 28 of 33
25-November-2015
92-42800-RKMB
Page 29
Heat Exchanger Assembly 180 240
Control Board Assembly 180 240
Coil Assembly 180 240
Page 29 of 33
25-November-2015
92-42800-RKMB
Page 30
Blower Assembly 180 240
Page 30 of 33
25-November-2015
92-42800-RKMB
Page 31
Evaporator Coil Assembly 090-120
Evaporator Coil Assembly 0150
Page 31 of 33
25-November-2015
92-42800-RKMB
Page 32
Evaporator Coil Assembly 180-240
Page 32 of 33
25-November-2015
92-42800-RKMB
Page 33
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 A small number of early production RKMB series were built with "2B" gas control components, but were labeled
with a " 2A" serial number.The units labeled with " 2A" have the " 2B" gas control parts. 2 Order the specified LP Conversion Kit 3 Order Gas Valve for Natural Gas along with LP ConversionKit 4 Harness as supplied is complete except for vacancy in pin positions 1 and 4 (orange wires for Limit Control). If
needed, these will have to be field fabricated or reused and inserted into harness plug.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject to change without notice. Document 92-42800-RKMB supersedes all previous parts lists for these models. See http://www.rheempartslists.net/92-42800-RKMB for the latest revision of this document. The manufacturer assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of equipment after the replacement of any original components.