35 Stk Fan Motor51-100998-1351-100998-1251-100998-28
36 Stk Fan Blade70-42484-0170-42484-0170-42484-01
37 Stk Capacitor - Fan Motor43-100496-1243-100496-1243-100496-11
Stk TXV - Sporlan61-102211-42 61-102211-42 61-102211-42
80Top Air StopAE-58933-02AE-58933-02AE-58933-02
81Top Coil SupportAE-58941-01AE-58941-01AE-58941-01
82FilterChannels (3) Center Is Two Channels Back To BackAE-58934-03AE-58934-03AE-58934-03
83IndoorCoil Drain Pan68-23559-0268-23559-0268-23559-02
Evaporator Coil - Coil Frame Assembly (includes Frame Sides, Angle, FrameBottom and Top Air
Stop)
MODEL
TECHNICALVARIATION
COOLING CAPACITY
ELECTRICAL DESIGNATION
COMPRESSOR GROUP
RKKN-
B
072
C
AS-104531-03 AS-104531-03 AS-104531-03
68-104248-03
(5)
RKKN-
B
072
C
RKKN-
B
072
D
68-104248-03
(5)
RKKN-
B
072
D
RKKN-
B
072
Y
68-104248-03
(5)
RKKN-
B
072
Y
Page 7 of 24
16-December-2014
92-42800-RKKN-B
Page 8
MODEL
No. Notes
45 Stk Main Limit - (Condenser Bulkhead) E - Electric47-23610-1947-23610-19
45 Stk Main Limit - (Condenser Bulkhead) X - NOX47-23610-1947-23610-19
46MainLimit ShieldAS-59152-01AS-59152-01
87 Stk Heat Exchanger - Includes Center PanelAS-59066-05AS-59066-04
MODEL
TECHNICALVARIATION
COOLING CAPACITY
HEATING CAPACITY
BURNER / MANIFOLD GROUP
RKKN-
B
072
10
AE-58922-01
(5)
47-22861-02
(2)
RKKN-
B
072
10
81-23593-01
(2)
See Orifice Selection Chart
RKKN-
B
072
13
AE-58922-01
(6)
47-22861-02
(2)
RKKN-
B
072
13
81-23593-01
(1)
Page 8 of 24
16-December-2014
92-42800-RKKN-B
Page 9
No. Notes
107 Stk Gas Valve - Natural Gas60-100394-02
107 Stk Gas Valve - LPSee Note 1
Stk Integrated Furnace Control Board (IFC)62-23599-03
Street Elbow81-17487-01
Nipple81-40683-02
Stk LP Conversion KitEP-85H
MODEL
GAS CODE
GAS CONTROLS
RKKN-
2G
Page 9 of 24
16-December-2014
92-42800-RKKN-B
Page 10
No. Notes
Louver Panel KitAXRX-AAD01B
Low Ambient Control KitRXRZ-A85
Compressor Time DelayRXMD-B04
Economizer - Single EnthalpyRXRD-MCCM3
Dual Enthalpy Upgrade KitRXRX-AV02
Carbon Dioxide SensorRXRX-AR02
Power Exhaust - "C" VoltageAXRX-BGF03C
Power Exhaust - "D" VoltageAXRX-BGF03D
Power Exhaust - "Y" VoltageAXRX-BGF03Y
Fresh Air Damper - ManualAXRF-FCA1
Fresh Air Damper - MotorizedAXRF-FCB1
Fresh Air Damper - Motorized (Smoke Detector Compatible)AXRF-JHB1
MODEL
TECHNICALVARIATION
COOLING CAPACITY
OPTIONS AND ACCESSORIES
RKKN-
B
072
Page 10 of 24
16-December-2014
92-42800-RKKN-B
Page 11
CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.)
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified
on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is based on a Natural Gas heating value of 1075 BTU/cu. ft and a pressure setting of 3.5 in. water column.
NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 2000 ft.
CAUTION: Selection of the correct LP Orifice requires the following information for the specific installation:
1) Furnace Input Rating (BTU/HR)
2) Number of Burners
2) Altitude (ft.)
For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-47 and the latest edition of the
National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1.
CAUTION:This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the
kit(s) specified on the product specification sheet for the unit.
NOTE:This Orifice sizing chart is developedusing the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and
CANB149.1.
NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on a heating value of 2500 BTU/cu. ft. and an elevation of 0 - 2000 ft.
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - NATURAL GAS
Number
of
Burners
PACKAGE EQUIPMENT - ORIFICE SELECTION CHART - LP
Number
of
Burners
0 - 2000
U.S.
0 - 2000
U.S.
2001 - 4000
U.S.
2001 - 4000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Elevation (ft.)
4001 - 6000
U.S.
Country
8000+
U.S.
Country
8000+
U.S.
0 - 2000
Canada
0 - 2000
Canada
2001 - 4500
Canada
2001 - 4500
Canada
16-December-2014
92-42800-RKKN-B
Page 11 of 24
Page 12
Exploded View 072
Page 12 of 24
16-December-2014
92-42800-RKKN-B
Page 13
Top Panel 072
Page 13 of 24
16-December-2014
92-42800-RKKN-B
Page 14
Side Panels 072
Page 14 of 24
16-December-2014
92-42800-RKKN-B
Page 15
Top Interior 072
Page 15 of 24
16-December-2014
92-42800-RKKN-B
Page 16
Blower Assembly - Belt Drive 072
Page 16 of 24
16-December-2014
92-42800-RKKN-B
Page 17
Control Box 072
Page 17 of 24
16-December-2014
92-42800-RKKN-B
Page 18
Blower Motor Mount Assembly - Belt Drive 072
Page 18 of 24
16-December-2014
92-42800-RKKN-B
Page 19
Plate Disconnect and Receptacle 072
Page 19 of 24
16-December-2014
92-42800-RKKN-B
Page 20
Evaporator Coil - Filter Channels 072
Heating Section 072
Page 20 of 24
16-December-2014
92-42800-RKKN-B
Page 21
Heat Exchanger Assembly 072
Burner Assembly 072
Page 21 of 24
16-December-2014
92-42800-RKKN-B
Page 22
Condenser and Coil Pads 072
Page 22 of 24
16-December-2014
92-42800-RKKN-B
Page 23
Compressor - Refrigeration Group 072
Page 23 of 24
16-December-2014
92-42800-RKKN-B
Page 24
NOTES
Stk It is recommended that stock be maintained for this part.
N/A Not Applicable
1 Order GasValve for Natural Gas along with LP Conversion Kit.
DISCLAIMER: This document is intended to provide general replacement parts information to aid qualified
service personnel in the repair of these models. The complete Model and Serial Number of the unit under repair
should be specified when selecting and ordering replacement parts. Specifications and illustrations are subject
to change without notice. Document 92-42800-RKKN-B supersedes all previous parts lists for these models. See
http://www.rheempartslists.net/92-42800-RKKN-B for the latest revision of this document. The manufacturer
assumes no obligation for errors or omissions. Service personnel must verify the proper and safe operation of
equipment after the replacement of any original components.