High Efficiency Condensing Power Direct Vent gas water heaters are a perfect choice when indoor air quality is a concern
Efficiency
• 0.82 EF
®
• ENERGY STAR
rated
Performance
• FHR: Up to 93 gallons for natural and
LP gas
• Recovery: 43.6 to 48.5 GPH at a
90° F rise, depending on model
Self-Diagnostic System
• Integrated system control for easy
installation and service
• Diagnostic system
control can be replaced without draining the water heater
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Power direct vents are an ideal choice
when either indoor air quality or negative air pressure are concerns
• Two-pipe system: one pipe pulls in
outside air for combustion and the other exhausts combustion gases
• 120 VAC, 60Hz, induced draft blower
• New whisper quiet blower
Innovative Technology
• Proven center ue design with
submerged coil type condensing heat exchanger
• Heat exchanger is porcelain coated
inside and out for increased product life
Flammable Vapor Detection System
• FVIR compliant protective
• Control system that disables the
heater in the presence of ammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 60 feet
• Use 2 or 3 inch diameter PVC, ABS, or CPVC vent pipe options. (In Canada ULC S636 PVC and CPVC must be used.)
• Vertical or horizontal termination
• Concentric vent kit available
Longer Life
• Dual anode rods protect the tank from corrosion
High Altitude Compliant
Models are certied for applications up to 9,000 feet above sea level
Plus…
• Enhanced ow brass drain valve
• Temperature and pressure relief valve included
• Low lead compliant
• Durable silicon nitride igniter (HSI)
• Inlet tube with diffuser enhances heat transfer
• Front access to condensate trap and vent pipe
• Condensate neutralizer option
• Standard replacement parts
Warranty
6-Year limited tank and parts warranty*
* See Residential Warranty Certicate for
complete information
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efciency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efciency performance criteria.
Professional
38 and 48-Gallon Capacities
Prestige
High Efficiency
Condensing
Power Direct Vent
Up to 40,000 Btu/h
Natural and LP Gas
LEED Points = 2
See specifications chart on back.
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 03/15 WP FORM NO. RHE-101EF Rev. 2
T
INTEGRATED HOME COMFORT
Water
INTEGRATED HOME COMFORT
Residential Gas
Prestige
Professional
High Efficiency
Condensing Power Direct Vent Water Heaters
Professional
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT Y P GAL. MODEL E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP
Short 38 RHE40S 40 – 48.5 – 74 – 60-3/8 60-1/8 51-1/16 22-1/8 14-1/8 8 44-1/4 3/4 26-11/16 220 0.82 –
Short 38 RHE40SP – 36 – 43.6 – 74 60-3/8 60-1/8 51-1/16 22-1/8 14-1/8 8 44-1/4 3/4 26-11/16 220 – 0.82
Tall 48 RHE50 40 – 48.5 – 93 – 68-3/4 68-5/8 59-11/16 22-1/8 14-1/8 8 52-7/8 3/4 26-11/16 250 0.82 –
Tall 48 RHE50P – 36 – 43.6 – 93 68-3/4 68-5/8 59-11/16 22-1/8 14-1/8 8 52-7/8 3/4 26-11/16 250 – 0.82
Energy Factor based on D.O.E. (Department of Energy) test procedures.
Prestige
GAS INPUT IN RECOVERY IN FIRST HOUR
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
High Efficiency Condensing Power Direct Vent Specifications
TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP.
VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIzE BACK WT.
D
1/2"
COMBUSTION
AIR INLET
COMBUSTION
EXHAUST (VENT)
HOT WATER
CONNECTION
H
H COLD WATER CONNECTION
F
BA C G
I
E
ENERGY FACTOR
T&P FITTING
3/4" NPT
Air-Inlet and Venting Information
From Sea Level Through 5,999 ft. Above Sea Level
Vent & Combustion Minimum Allowed Maximum Allowed Vent
Air-Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion and Combustion Pipe Diameter Air-Inlet Lengths – Air-Inlet Lengths – Air-Inlet System
Model (Inches) Each Pipe Run (Ft.) Each Pipe Run (Ft.) Termination(s)
RHE40S 2 7 30 90° Elbows Concentric*
RHE40S 3 7 60 90° Elbows Concentric*
RHE50 2 7 30 90° Elbows Concentric*
RHE50 3 7 60 90° Elbows Concentric*
From 6,000 ft. Above Sea Level Through 8,999 ft. Above Sea Level
Vent & Combustion Minimum Allowed Maximum Allowed Vent
Air-Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion and Combustion Pipe Diameter Air-Inlet Lengths – Air-Inlet Lengths – Air-Inlet System
Model (Inches) Each Pipe Run (Ft.) Each Pipe Run (Ft.) Termination(s)
RHE40S 2 Not Allowed Not Allowed
RHE40S 3 7 45 90° Elbows Concentric*
RHE50 2 Not Allowed Not Allowed
RHE50 3 7 45 90° Elbows Concentric*
One 90° elbow is equivalent to 5 feet of straight pipe. One 45° elbow is equivalent to 2.5 feet of straight pipe. The vent and combustion air inlet terminations are not included in the equivalency calculations. * Use only Rheem 3 inch concentric termination kit SP20245.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 03/15 WP FORM NO. RHE-101EF Rev. 2
2
Loading...