Rheem Professional Classic Series Ultra Low NOx Specification

Water
INTEGRATED HOME COMFORT
T
INTEGRATED HOME COMFORT
Residential Gas
Professional Ultra Low NOx Water Heaters
Classic
Professional
Classic
Ultra Low NOx gas water heaters are SCAQMD rule 1121 compliant with 10 ng/J NOx emissions
Efficiency
• .60 - .63 EF
• More hot water at a low operating
cost
Performance
• FHR: 53 - 91 gallons for natural gas
• Recovery: 30.3 to 40.4 GPH at a
90° F rise, depending on model
Guardian System™ & Sensor
• Exclusive air/fuel shut-off device for
double protection
• Maintenance free – no lter to clean
• Protective control system that
disables the heater in the presence of ammable vapor accumulation
Low Emissions
• Ultra Low NOx radiant
burner design
• Stainless steel construction
• SCAQMD Rule 1121 compliant
• Meets 10 ng/J NOx requirements
Self-Cleaning
• EverKleen™ patented system ghts
sediment build-up
• Reduces fuel costs
• Provides more hot water
Easy to Light
• No matches required
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
High Altitude Compliant
• All models certied up to 5,999 ft. above sea level
• 38-Gallon short model certied up to 8,400 ft. above sea level
Plus…
• Enhanced ow brass drain valve
• Temperature and pressure relief valve included
• Low lead compliant
®
• Exclusive Rheemglas
lining
Warranty
• 6-Year limited tank and parts warranty*
With ProtectionPlus™ the 6-year limited
• tank warranty becomes 10-year
* See Residential Warranty Certicate for
complete information
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efciency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efciency performance criteria.
FLUE
H
HOT
WATER
CONNECTION
BA
1/2"
D
ANODE ROD
H
COLD
WATER
CONNECTION
F E
3/4" N.P.T.
RELIEF
VALVE
OPENING
C
G
Professional
Classic
Ultra Low NOx
28, 38, and
48-Gallon Capacities
Up to 40,000 Btu/h
Natural Gas
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO WATER HT. TO WATER Y GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK GAS VENT CONN. SIDE T&P CONN. SHIP. ENERGY P GAL. MODEL THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAM. CONN. SIZE CNTR. VALVE SIZE WT. FACTOR E CAP. NUMBER NAT. NAT. NAT. A B C D E F G H (LBS) NAT.
Tall 28 PROG28-30U RH63 30 30.3 53 58-7/8 56-1/8 16-1/2 17-1/2 3 or 4 8 50-1/8 3/4 108 0.63
Tall 38 PROG38-38U RH62 38 38.4 72 60-1/2 57-3/4 19 17-1/2 3 or 4 8 51-3/4 3/4 132 0.62
Tall 48 PROG48-40U RH60 40 40.4 91 60-5/8 57-7/8 20-1/2 17-1/2 3 or 4 8 51-3/4 3/4 139 0.60
Short 38 PROG38S-36U RH62 36 36.4 68 51-7/8 49-1/8 21 17-1/2 3 or 4 8 43 3/4 127 0.62
Energy Factor based on D.O.E. (Department of Energy) test procedures.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 02/15 WP FORM NO. PROG RHULN N