Professional Classic Plus™ Power Direct Vent gas
water heaters are a perfect choice for tight
construction or when indoor air quality is a concern
Water
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
Efficiency
• 0 .62 - 0.67** EF
Performance
• FHR: Up to 139 gallons for natural
and LP gas
• Recovery: 40 to 75.8 at a
90 degree rise
Self-Diagnostic System
• Electronic gas control for
improved monitoring and
service
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Two pipe system: one pipe pulls in
outside air for combustion and the
other exhausts combustion gases
• 120 VAC powered blower
• New whisper quiet blower
Flammable Vapor
Detection System
• Protective control system that
disables the heater in the presence of
ammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 100 feet
• PVC or CPVC certied to ULC-S636
vent pipe options
• Vertical or horizontal termination
• Concentric vent kit available
Longer Life
• Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection
High Altitude Compliant
•
Models are certied for applications up
to 10,200 feet above sea level
Plus…
• Enhanced ow brass drain valve
• Temperature and pressure relief valve
included
• Low lead compliant
• Durable silicon nitride igniter (HSI)
• Side taps for space heating
applications on 50-65, 65 and
75-gallon models
• EverKleen™ patented system ghts
sediment build-up
• Standard replacement parts
Warranty
• 8-Year limited tank and parts
warranty*
• With ProtectionPlus™ the 8-year limited
tank warranty becomes 10-year
ProtectionPlus – order part number
SP20081 (6 pack only)
* See Residential Warranty Certicate for
complete information
COMBUSTION
AIR INLET
COMBUSTION
EXHAUST
(VENT)
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
Professional Classic Plus
Power Direct Vent
40 to 75-Gallon Capacities
Up to 75,100 Btu/h
Natural and LP Gas
LEED Point = 1
T&P FITTING
3/4" N.P.T.
I
C
B A
F
D
1/2"
E
G
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT AVG.
Y NATURAL GAS
P GAL. MODEL
E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP NAT
Tall 40 PRO+G40T-40N CN67 PDV** 40 38 40.4 38.4 73 73 68-1/2 69-1/4 60-1/4 19-3/4 14 8 53-3/4 3/4 29-1/2 180 0.67 0.67 $272
Tall 50 PRO+G50T-40N CN67 PDV** 40 40 40.4 40.4 93 93 67-5/8 67-7/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 205 0.67 0.67 $272
Tall 50 PRO+G50T-65N CN62 PDV 65 47 65.7 47.5 111 92 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.62 0.62 $294
Tall 65 PRO+G65T-65N CN62 PDV 65 56 65.7 56.6 120 113 71-1/4 72-1/4 61-3/4 23 14-5/8 11 54 3/4 34-1/4 285 0.62 0.62 $294
Tall 75 PRO+G75T-75N CN62 PDV 75.1 70 75.8 70.7 139 139 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 0.62 0.62 $495†
Specify LP gas when ordering. Add gas input and "P" to model number. Example: PRO+G40T-38P CN67 PDV
**ENERGY STAR® qualified models.
GAS INPUT IN RECOVERY IN FIRST HOUR
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP.
VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIZE BACK WT.
ENERGY
FACTOR
ANNUAL
OPER. COST
See venting chart on back.
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN

Residential Gas
Water
Professional Classic Plus
Power Direct Vent Water Heaters
Air-Inlet Venting Information for PRO+G40T-40N CN67 PDV and PRO+G50T-40N CN67PDV
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 30 90° Elbows Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 2 7 30 90° Elbows Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 90° Elbows –
PRO+G40T-40N CN67 PDV 2 7 30 – Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 2 7 15 – Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G40T-40N CN67 PDV 2 7 15 – Concentric*
PRO+G40T-40N CN67 PDV 3 7 60 90° Elbows –
PRO+G40T-40N CN67 PDV 3 7 50 – Concentric*
PRO+G50T-40N CN67PDV 3 7 60 90° Elbows –
PRO+G50T-40N CN67PDV 3 7 50 – Concentric*
From Sea Level Through 5,999 ft. Above Sea Level
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
Air-Inlet Venting Information for PRO+G50T-65N CN62 PDV, PRO+G65T-65N CN62 PDV and PRO+G75T-75N CN62 PDV
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 50 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 40 – Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 50 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 40 – Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows –
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 30 90° Elbows –
PRO+G65T-65N CN62 PDV 3 8 20 – Concentric*
PRO+G65T-65N CN62 PDV 4 8 100 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 25 90° Elbows –
PRO+G75T-75N CN62 PDV 3 8 20 – Concentric*
PRO+G75T-75N CN62 PDV 4 8 100 90° Elbows –
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 50 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 40 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
PRO+G65T-65N CN62 PDV 4 8 40 90° Elbows –
PRO+G75T-75N CN62 PDV 4 8 50 90° Elbows –
Vent & Combustion Air-Inlet Min. Allowed Equivalent Vent & Combustion Max. Allowed Equivalent Vent & Combustion Vent and Combustion
Model System Diameter (Inches) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet Lengths – Each Pipe Run (Ft.) Air-Inlet System Termination(s)
PRO+G50T-65N CN62 PDV 3 7 25 90° Elbows –
PRO+G50T-65N CN62 PDV 3 7 20 – Concentric*
PRO+G50T-65N CN62 PDV 4 7 100 90° Elbows –
• One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe.
* Use only Rheem 3 inch concentric termination.
From Sea Level Through 2,000 ft. Above Sea Level
From 2,001 ft. Above Sea Level Through 5,999 ft. Above Sea Level
From 6,000 ft. Above Sea Level Through 7,700 ft. Above Sea Level
From 7,701 ft. Above Sea Level Through 10,200 ft. Above Sea Level
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
2