gas water heaters exceed ANSI standards for flammable vapor ignition resistance
Water
Residential Gas
Professional Classic Heavy Duty Water Heaters
Efficiency
• .53 - .57 EF
Performance
• FHR: Up to 141 gallons for natural gas, up to 109 gallons for LP gas
• Recovery: Up to 75.8 gallons for natural gas, up to 67.7 gallons for LP gas at a 90 degree rise
Guardian System™ & Sensor
• Exclusive air/fuel shut-off device
• Maintenance free – no lter to clean
• Disables the heater in the presence of ammable vapor accumulation
Flame Arrestor PlateCombustion Shut-off System
Self-Cleaning
• 60-gallon models only
• EverKleen
patented system ghts
sediment build-up
• Reduces fuel costs
• Fights sediment build-up
Easy to Light
• Piezo Ignitor – no matches required
Low Emissions
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements
Longer Life
• Rheem exclusive R-Tech (resistored) anode rod provides long-lasting tank protection
High Altitude Compliant
• All models are certied for applications up to 7,700 feet above sea level
Plus…
• Enhanced-ow brass drain valve
• Temperature and pressure relief valve included
• Low lead compliant
• Side water connections for space heating applications for 75-gallon models
• Standard replacement parts
Warranty
• 6-Year limited tank and parts warranty*
* See Residential Warranty Certicate for
complete information
H
HOT
WATER
FLUE
BA
1/2"
ANODE ROD
H
COLD
WATER
F E
3/4" N.P.T.
RELIEF
VALVE
OPENING
C
G
SIDE TAPS (48, 63, 75 & 98 GAL. MODELS ONLY)
Professional Classic
Heavy Duty
60 and 75-Gallon Capacities
Up to 75,100 Btu/h Natural and LP Gas
D
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO WATER HT. TO WATER Y P GAL. MODEL E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H (LBS) NAT.
Tall 60 PROG60S-50N CN56 50 50 50.5 50.5 107 107 62 58 23 13-1/4 4 8 48-1/2 3/4 180 0.56
Tall 60 PROG60S-50N CN57† 50 50 50.5 50.5 107 107 62 58 22-1/4 13-1/4 4 8 48-1/2 3/4 180 0.57
Tall 75 PROG75S-75N CN53 75.1 65 75.8 67.7 141 109 64 60 26-1/4 14-3/4 4 11 53-1/4 1 320 0.53
Specify LP gas when ordering. Add gas input and "P" to model number. Example: PROG60S-50P CN56
† Complies with BC construction requirements.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
GAS INPUT IN RECOVERY IN FIRST HOUR
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Brampton, Ontario L6Y 0P5 • www.rheem.com
HT. TO TANK GAS VENT CONN. SIDE T&P CONN. SHIP. ENERGY
VENT HT. DIAM. CONN. SIZE CNTR. VALVE SIZE WT. FACTOR
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 01/14 WP FORM NO. PROG RHHDCAN